• 제목/요약/키워드: wind farm

Search Result 536, Processing Time 0.031 seconds

Cause Analysis of Cone Roof Tank Collapse during Plant Construction (플랜트 공사 중 발생한 Cone Roof Tank 붕괴 사고 원인 분석)

  • Kim, Seung-Han;Kim, Byung-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.3
    • /
    • pp.71-80
    • /
    • 2016
  • This study is on safety improvement measures through analysis of accident cases during plant storage tank construction. Storage tank is a general term for artificial ground facility constructed to store oil, water, gas, and other chemicals. Some companies have clustered storage tanks (tank farm). The construction methods vary according to the component and types of fluids. Because most of the construction procedures include lifting heavy weight materials using heavy construction equipment and are carried out at high places, storage tank construction contains more risk factors than normal aerial construction. Recently, major accidents such as storage tank collapse have occurred often, and cost many lives due to the characteristics of the structure. In this study we would like to analyze the cause of these accidents and propose measures to improve safety.

Transmission Line Fault Location Algorithm Using Estimated Local Source Impedance (자기단 전원임피던스 추정을 이용한 송전선 고장점표정 알고리즘)

  • Kwon, Young-Jin;Kim, Su-Hwan;Kang, Sang-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.885-890
    • /
    • 2009
  • A fault location algorithm using estimated local source impedance after a fault is proposed in this paper. The method uses after fault data only at the local end. It uses the negative sequence current distribution factor for more accurate estimation. The proposed algorithm can keep up with the variation of the local source impedance. Therefore, the proposed algorithm especially is valid for a transmission line interconnected to a wind farm that the equivalent source impedance changes continuously. The performance of the proposed algorithm was verified under various fault conditions using the Simpowersystem of MATLAB Simulink. The proposed algorithm is largely insensitive to the variation in fault distance and fault resistance. The test results show a very high accurate performance.

A study on the Voltage analysis of Sung-san S/S MTr #1 Hang-won wind farm (제주 성산 S/S MTr #1 행원 풍력단지 전압해석)

  • Kim, Sang-Jun;Cho, Min-Ho;Yoon, Gi-Gab;Jang, Sang-Ok;Ahn, Jeong-Shik
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.345-347
    • /
    • 2003
  • 본 논문에서는 분산전원이 기존의 배전계통상에 도입되는 경우에 대하여 전압변동해석을 수행하기 위하여, 풍력발전단지가 도입된 제주 성산 변전소를 선정하여 MATLAB 프로그램을 이용하여 시뮬레이션을 수행하고 전압변동상황을 예측, 이에 따른 문제점과 그에 대한 대책을 제시하도록 할 것이다.

  • PDF

Development of 1MVA STATCOM for Wind Farm (풍력단지 적용을 위한 1MVA STATCOM 개발)

  • Jung, HongJu;Shin, HyunJin;Yeo, SangMin;Park, JungSoo;Lee, JeongMin;Suh, InYoung
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.288-289
    • /
    • 2010
  • 다양한 신재생에너지의 발전원 확보를 위해서는 발전원의 출력 안정화가 필수적으로 수반되어져야 한다. 본 논문은 다양한 신재생에너지 발전원의 안정화를 위한 핵심기기 중 하나인 STATCOM의 설계 및 제작에 관한 내용이다. 개발 진행 중인 1MVA STATCOM은 제주도 행원 풍력발전의 전력품질을 개선하기 위해 설치될 예정으로 3-Level 인버터로 구성된 Stack과 LC 필터 그리고 변압기와 수배전반으로 구성되어 있다.

  • PDF

Issues for Development of a Large-Sclae Offshore Wind Farm SCADA System (대규모 해상풍력 SCADA 개발을 위한 고려사항)

  • Kim, Dong-Wook;Jung, Nam-Joon;Lee, Jae-Kyung;Choi, Hyo-Yul
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.04a
    • /
    • pp.993-996
    • /
    • 2012
  • 전 세계적으로 신재생에너지에 대한 관심이 고조되고 있는 가운데, 국내에서도 대규모 해상 풍력발전단지 개발을 진행중에 있다. 현재 풍력발전단지 운영 기술인 SCADA 시스템의 국내 기술 수준은 매우 낮은 수준으로 현장 적용 가능한 SCADA 시스템 개발이 시급한 실정이다. 따라서 본 논문에서는 대규모 해상 풍력발전단지 SCADA 시스템 개발을 위해서 필요한 고려 사항을 분석하였다.

A Study on the Uplift Capacity of Cylindrical Concrete Foundations for Pipe-Framed Greenhouse (파이프 골조온실의 원주형 콘크리트 기초의 인발저항력에 관한 연구)

  • ;;;;Shino Kazuo
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.4
    • /
    • pp.109-119
    • /
    • 1998
  • Recently pipe-framed greenhouses are widely constructed on domestic farm area. These greenhouses are extremely light-weighted structures and so are easily damaged under strong wind due to the lack of uplift resistance of foundation piles. This experiment was carried out by laboratory soil tank to investigate the displacement be haviors of cylindrical pile foundations according to the uplift loads. Tested soils were sampled from two different greenhouse areas. The treatment for each soil type are consisted of 3 different soil moisture conditions, 2 different soil depths, and 3 different soil compaction ratios. Each test was designed to be repeated 2 times and additional tests were carried out when needed. The results are summarized as follows : 1. When the soil moisture content are low and/or pile foundations are buried relatively shallow, ultimate uplift capacity of foundation soil was generated just after begining of uplift displacement. But under the high moisture conditions and/or deeply buried depth, ultimate up-lift capacity of foundation soil was generated before the begining of uplift displacement. 2. For the case of soil S$_1$, the ultimate uplift capacity of piles depending on moisture contents was found to be highest in optimum moisture condition and in the order of air dryed and saturated moisture contents. But for the case of soil S$_2$, the ultimate uplift capacity was found to be highest in optimum moisture condition and in the order of saturated and air dryed moisture contents. 3. Ultimate uplift capacities are varied depending on the pile foundation soil moisture conditions. Under the conditions of optimum soil moisture contents with 60cm soil depth, the ultimate uplift capacity of pile foundation in compaction ratio of 80%, 85%, and 90% for soil 51 are 76kg, 115kg, and 155kg, respectively, and for soil S$_2$are 36kg, 60kg, and 92kg, respectively. But considering that typical greenhouse uplift failure be occurred under saturnted soil moisture content which prevails during high wind storm accompanying heavy rain, pile foundation is required to be designed under the soil condition of saturated moisture content. 4. Approximated safe wind velosities estimated for soil sample S$_1$and S$_2$are 32.92m/s and 26.58m/s respectively under the optimum soil condition of 90% compaction ratio and optimum moisture content. But considering the uplift failure pattern under saturated moisture contents which are typical situations of high wind accompanying heavy rain, the safe wind velosities for soil sample S$_1$and S$_2$are not any higher than 20.33m/s and 22.69m/s respectively.

  • PDF

A Study on the Feasibility Evaluation of Overseas Wind Power Projects with RETScreen Software (RETScreen를 활용한 풍력발전사업의 투자 적절성 평가 사례 연구)

  • Lee, Ju-Su;Choi, Bong Seok;Lee, Hwa-Su;Jeon, Eui Chan
    • Journal of Climate Change Research
    • /
    • v.4 no.2
    • /
    • pp.105-114
    • /
    • 2013
  • Recently, foreign direct investment of Korea has increased significantly. Foreign direct investment is motivated by various reasons and renewable energy investments in foreign countries can be performed by many causes. Korean companies can enjoy the export of products, related EPC contracts, acquisition of the knowledge of the project management technique, pre-occupying effect of the market and profit itself. Wind power projects have biggest share in the investment amounts among the renewable energy business. So, in this study, one wind farm project was selected and supposed to be invested in China, USA, Germany and UK at the same time and the effect of electricity price, corporate income tax, inflation rate and interest rate of debt were analyzed. The result showed that investing in Germany is most profitable because of the highest electricity price and electricity price and debt interest rate are the most sensitive factors for IRR. This approach would be helpful to make decisions in investing foreign wind power projects.

A Study on the Calculation of Optimal Compensation Capacity of Reactive Power for Grid Connection of Offshore Wind Farms (해상풍력단지 전력계통 연계를 위한 무효전력 최적 보상용량 계산에 관한 연구)

  • Seong-Min Han;Joo-Hyuk Park;Chang-Hyun Hwang;Chae-Joo Moon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.19 no.1
    • /
    • pp.65-76
    • /
    • 2024
  • With the recent activation of the offshore wind power industry, there has been a development of power plants with a scale exceeding 400MW, comparable to traditional thermal power plants. Renewable energy, characterized by intermittency depending on the energy source, is a prominent feature of modern renewable power generation facilities, which are structured based on controllable inverter technology. As the integration of renewable energy sources into the grid expands, the grid codes for power system connection are progressively becoming more defined, leading to active discussions and evaluations in this area. In this paper, we propose a method for selecting optimal reactive power compensation capacity when multiple offshore wind farms are integrated and connected through a shared interconnection facility to comply with grid codes. Based on the requirements of the grid code, we analyze the reactive power compensation and excessive stability of the 400MW wind power generation site under development in the southwest sea of Jeonbuk. This analysis involves constructing a generation site database using PSS/E (Power System Simulation for Engineering), incorporating turbine layouts and cable data. The study calculates reactive power due to charging current in internal and external network cables and determines the reactive power compensation capacity at the interconnection point. Additionally, static and dynamic stability assessments are conducted by integrating with the power system database.

Research trends in seabird and marine fish migration: Focusing on tracking methods and previous studies (바닷새 및 해양어류의 이동 연구 동향: 위치추적 기법과 연구 사례를 중심으로)

  • Jin-Hwan Choi;Seongho Yun;Mi-Jin Hong;Ki-Ho Kang;Who-Seung Lee
    • Korean Journal of Environmental Biology
    • /
    • v.40 no.1
    • /
    • pp.25-53
    • /
    • 2022
  • In this study, trends in research methods and topics of seabird and marine fish migration were examined. Based on the framework of existing animal migration studies, future research directions were proposed in relation to the migration of seabirds and fish. In terms of research methodology, with the development of science and technology, tracking techniques using radio telemetry, acoustic telemetry, RFID (radio-frequency identification), satellite tracking, and geolocators are widely used to study seabird and fish migration. Research is also conducted indirectly through a population survey and the analysis of substances in the body. Research contents are largely classified into extrinsic factors that affect migration(such as environmental variables and interspecific competition), intrinsic factors such as hormones, anthropogenic activities including fishery and offshore wind farm, and the effect of global climate change. In future studies, physiological factors that influence or cause migration and dispersal should be identified concerning intrinsic factors. For the analysis of migration ability, it is necessary to study effects of changes in the magnetic field on the migration ability of seabirds and fish, interspecific differences in spatiotemporal migration ability, and factors that influence the migration success rate. Regarding extrinsic factors, research studies on effects of anthropogenic disturbances such as fishery and offshore wind farm and global climate change on the migration and dispersal patterns of marine animals are needed. Finally, integrated studies on the migration of seabirds and fish directly or indirectly affecting each other in various ecological aspects are required.