• 제목/요약/키워드: width function

검색결과 1,018건 처리시간 0.031초

Effects of Stud Spacing, Sheathing Material and Aspect-ratio on Racking Resistance of Shear Walls

  • Jang, Sang Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • 제30권3호
    • /
    • pp.97-103
    • /
    • 2002
  • This study was carried out to obtain basic information on racking resistance of shear walls and the factors affecting racking resistance of shear walls. Shear walls constructed by larch lumber nominal 50 mm × 100 mm framing and various sheathing materials were tested by applying monotonic and cyclic load functions. Shear walls with various stud spacing such as 305 mm, 406 mm, and 610 mm were tested under both of monotonic and cyclic loads and shear walls with various aspect (height-width) ratios were tested under cyclic load functions. The effect of hold-down connectors in shear walls was also tested under cyclic load functions. Racking resistance of shear walls has very close linear relation with stud spacing and width of shear walls. The ultimate racking strength of shear walls was reached at around or before the displacement of 20 mm. It was proposed in this study that the minimum racking strength and minimum width for shear wall be 500 kgf and 900 mm, respectively. Load-displacement curves obtained by racking tests under monotonic load functions can be represented by three straight line segments. Under cyclic load functions, envelope curves can be divided into three sections that can be represented by straight lines and the third section showed almost constant or decreasing slope.

Double-Pass System (Optical Quality Analysis System) for Analysis of the Multifocal Function of a Diffractive Multifocal Intraocular Lens (Acrysof ReSTOR®) Compared to a Monofocal Intraocular Lens (Acrysof IQ®)

  • Hwang, Ho Sik;Shin, Hye Young;Joo, Choun-Ki
    • Journal of the Optical Society of Korea
    • /
    • 제18권2호
    • /
    • pp.110-117
    • /
    • 2014
  • In this study, we objectively determined whether the ReSTOR as a multifocal IOL (intraocular lens) has a multifocal function compared to the IQ as a monofocal IOL in vivo by OQAS (Optical Quality Analysis System). Eighteen patients who had cataract surgery with implantation of ReSTOR (27 eyes) and 15 patients with IQ (21 eyes), were included inthis study. Uncorrected distance visual acuity (UCDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UCNVA)and distance corrected near visual acuity (DCNVA) were measured. After setting the artificial pupil size to 3 mm, we performed 'Optical quality'. We inputted defocus diopters of (objective spherical refraction)(far), (objective spherical refraction-1.25 D)(intermediate),(objective spherical refraction-2.5 D)(near), and (objective spherical refraction-3.5 D)(very near) into 'selected spherical refraction' simulating the optical quality at far, intermediate, and near distance. We changed the pupil size to 5 mm and repeated the same measurements. The UCDVA and CDVA did not show significant differences between the 2 groups. But, the UCNVA and DCNVA of the ReSTOR group were better than those of the IQ group (p=0.000, p=0.000). For 3 mm pupil, at far distance, modulation transfer function (MTF) cut off and point spread function (PSF) width at 50% of ReSTOR were worse than those of IQ (p=0.039, p=0.020). At intermediate distance, MTF cut off, Strehl ratio and PSF width at 50% of ReSTOR were worse than those of IQ (p=0.001, p=0.001, p=0.000). At near distance, MTF cut off of ReSTOR was worse than that of IQ (p=0.033). At very near distance, MTF cut off and Strehl ratio of ReSTOR were worse than those of IQ (p=0.002, p=0.002), but PSF width at 50% of ReSTOR was better than that of IQ. For 5 mm pupil, most parameters at each distance, there was no significant difference between the 2 groups. Only PSF width at 50% of ReSTOR were worse than those of IQ at intermediate distance (p=0.013). It was impossible to show the multifocal function of ReSTOR compared to the IQ byOQAS.

수압과 균열폭 변화에 따른 콘크리트 투수계수의 실험적 연구 (Permeability of Cracked Concrete as a Function of Hydraulic Pressure and Crack Width)

  • 현태양;김진용;김진근
    • 콘크리트학회논문집
    • /
    • 제20권3호
    • /
    • pp.291-298
    • /
    • 2008
  • 높은 수압에서 균열이 있는 콘크리트의 투수계수에 대한 연구를 수행하였으며, 이를 위해 기존의 균열이 있는 콘크리트 투수실험의 균열 유발 방법과 압력 조절 방법을 개선하였다. 실험체를 쪼갠 후 다시 붙이는 방법으로 확실한 관통 균열을 유발하였으며, 압력계와 감압계를 사용하여 압력조절을 간소화하였다. 균열폭을 측정할 때 균열폭 분류를 정하여 범위에 드는 실험체만 실험을 수행하였다. 실험 변수는 수압 (0.1$\sim$2 bar)과 균열폭 (30$\sim$100 ${\mu}m$)이다. 실험 결과, 균열폭과 수압이 증가함에 따라 투수계수가 증가하는 경향을 보였으며, 자기 치유의 영향으로 시간에 따라 투수계수가 점차로 감소하는 것으로 나타났다. 실험 초기의 투수계수는 균열폭에 많은 영향을 받지만, 최종 투수계수는 균열폭에 의한 영향이 상대적으로 작았다. 균열폭이 100 ${\mu}m$일 때는 균열폭이 30, 50 ${\mu}m$일 때에 비해 압력에 따른 투수계수의 변화가 컸는데, 수압이 0.1 bar에서 0.25 bar로 증가하면 투수계수가 약 190배로 크게 증가하는 것으로 나타났다.

사다리꼴 미세유로의 형상최적화 (Shape Optimization of a Trapezoidal Micro-Channel)

  • 후세인 아프잘;김광욜
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2666-2671
    • /
    • 2007
  • This work presents microchannel heat sink shape optimization procedure using Kriging method. Design variables relating to microchannel width, depth and fin width are selected, and thermal resistance has been taken as objective function. Design points are selected through a three-level fractional factorial design of sampling method. Navier-Stokes and energy equations for laminar flow and conjugate heat transfer are solved at these design points using a finite volume solver. Solutions are carefully validated with experimental results. Using the numerically evaluated objective function, a surrogate model (Kriging) is constructed and optimum point is searched by sequential quadratic programming. The process of shape optimization greatly improves the thermal performance of microchannel heat sink under constant pumping power.

  • PDF

가우스 잡음을 고려한 비선형 펄스 변조 시스템의 안정도 분석 (Stability Analysis of Nonlinear Pulse-Modulated System Subject to Gaussian Noise)

  • 강영채
    • 대한전자공학회논문지
    • /
    • 제19권6호
    • /
    • pp.67-79
    • /
    • 1982
  • 가우스 잡음의 출현시 PWM 시스템의 안정도가 연구되었다. 일반 시스템은 종래의 서술 함수 방법을 이용할 때 비선형 소자와 선형 소자로 나누어진다. 등가 어드미턴스 개념이 이 시스템의 비선형 소자의 전달 특성을 구하는데 사용되었다. 이 논문에서는 가우스 잡음만이 존재하는 경우 자기 발진 조건이 유도되었고 그 결과를 컴퓨터 시뮬레이션으로 분석하였다. The stability of general pulse-width modulation system with Gaussian random disturbance was discussed . General system is divided into nonlinear and linear elements using the conventional describing function method. The concept of the equivalent admittance was used to find the transfer characteristic of the nonlinear element of the system. In this paper the self-sustained oscillation condition in the autonomous system was derived and the results was analyzed with computer simulation.

  • PDF

크리깅 모델을 이용한 미세유로의 형상최적설계 (Shape Optimization of a Micro-Channel Using Kriging Model)

  • 후세인 아프잘;김광용
    • 대한기계학회논문집B
    • /
    • 제31권9호
    • /
    • pp.733-740
    • /
    • 2007
  • Microchannel heat sink shape optimization is performed using Kriging method. Design variables relating to microchannel width, depth and fin width are selected, and thermal resistance has been taken as objective function. Design points are selected through a three-level fractional factorial design of sampling method. Navier-Stokes and energy equations for laminar flow and conjugate heat transfer are solved at these design points using a finite volume solver. Solutions are carefully validated with experimental results. Using the numerically evaluated objective function, a surrogate model (Kriging) is constructed and optimum point is searched by sequential quadratic programming. The process of shape optimization greatly improves the thermal performance of microchannel heat sink under constant pumping power.

Line-profile Formula in the Carbon Nanotubes by Electron Spin Resonance

  • Park, Jung-Il;Lee, Haeng-Ki
    • 한국자기공명학회논문지
    • /
    • 제16권1호
    • /
    • pp.11-21
    • /
    • 2012
  • The line-width of carbon nanotubes (CNTs) was studied as a function of the temperature at a frequency of 9.49 GHz in the presence of external electromagnetic radiation. The relative frequency dependence of the absorption power is obtained with the projection operator technique (POT) proposed by Kawabata. The line-width increased as the temperature increased in the high-temperature region (T>200 K). The scattering is little affected in the low-temperature region (T<200 K) because there is no correlation between the resonance field and the Fermi-Dirac distribution function. Thus, the present technique is considered to be more convenient to explain the resonant system as in the case of other optical transition problems.

長方形柱 後流에 關한 實驗的 硏究 (An experimental Study of the Wake Flow Past a Rectangular Cylinder)

  • 남청도
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제15권3호
    • /
    • pp.45-56
    • /
    • 1991
  • This paper describes characteristics of the flow pattern of the flow past a rectangular cylinder experimentally investigated. The width-to-length ratio of the section varried from 2 to4. For the statistical treatment, autocorrelation coefficient, probability density function and power spectral density function are obtained by the digital processing technic through on-line system with a hot wire anemometer. As a results, it was found that strong periodic coherent eddies structure is sustained to about 20H downstream from the cylinder. And nearer the cylinder in the wake, the number of turbulent eddies of a large scale coherent structure are comparatively much more dominant than that of a small scale one. By the analysis of power spectrum, It was cleared that there exists a certain range of the width to length ratio between 2.5 and 3 of which the flow pattern changes abruptly with a sudden discontinuity in Strouhal number.

  • PDF

Field Measurements of Wave Directionality in Water of Finite Depth

  • Memos, Constantine;Ziros, Athanassios
    • Ocean and Polar Research
    • /
    • 제25권4호
    • /
    • pp.437-446
    • /
    • 2003
  • Field measurements of directional waves were carried out during the summer of 2002 at two coastal sites in water of finite depth. A couple of general purpose instruments were used employing acoustic Doppler technology. The aim of the study was to investigate the spatial behavior of the directional movement of waves as they come ashore. In total,74 tests were carried out during which sea states of low to moderate intensity were recorded. A great number of these runs displayed bimodal characteristics of the spreading function at high frequencies. It was found that in general, the frequency-integrated directional width tends to broaden as the water shoals and when refraction effects are negligible. This is attributed to wave-wave interactions that become pronounced in shallow water. The same directional width showed, also, a tendency to increase with increasing peak frequency of the sea state spectrum. The behavior of the kurtosis of the spreading function was also examined. It was found that for higher frequencies this index tends to increase in wave spectra above a certain sea severity threshold.

A Study on Safety of Environmental Cleaners' Noctilucent Jackets

  • Shim, Boo-Ja
    • 패션비즈니스
    • /
    • 제10권3호
    • /
    • pp.129-142
    • /
    • 2006
  • This research chose 135 environmental cleaners in Busan Metropolitan City as subjects. First, the reality of wearing their safety jackets was investigated. Next, visual evaluation of the reflexive function of the current safety jackets was made. Then, based on the above results and the subsequent improvement proposal, the final product, the research costume, was made. 1. Based on the investigation of the wearing reality of safety jackets and the visual evaluation results of the reflexive function, an improvement proposal was made. As cleaners are usually seen sidewise on the roads and lateral luminosity is rather low, this aspect was compensated on the part of a jacket. Also, the reflexive belt used the diagram of ${\Delta}$ to improve visual effects. 2. As the lower body held the accident frequency of 45.0%, the sides of pants had the reflexive belt to increase visibility. 3. In consideration of the mutual effects between the background cloth and general reflexive width, the same width (5cm) of the reflexive belt as that of Type A was adopted.