• 제목/요약/키워드: widening

검색결과 627건 처리시간 0.029초

Films for Widening the Viewing Angle of LCDs

  • Mori, Hiroyuki
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.76-79
    • /
    • 2007
  • Optical compensation films are widely used to enlarge viewing angle characteristics for LCDs. A new surface film with an inner light scattering layer was newly developed to improve gray scale inversion. This paper describes technologies regarding these films that enhance the viewing angle characteristics for LCDs.

  • PDF

박막 알루미늄을 이용한 규칙적으로 정렬된 나노급 미세기공 어레이 제조기술 개발 (Development of Fabrication Technique of Highly Ordered Nano-sized Pore Arrays using Thin Film Aluminum)

  • 이재홍;김창교
    • 한국전기전자재료학회논문지
    • /
    • 제18권8호
    • /
    • pp.708-713
    • /
    • 2005
  • An alumina membrane with nano-sized pore array by anodic oxidation using the thin film aluminum deposited on silicon wafer was fabricated. It Is important that the sample prepared by metal deposition method has a flat aluminum surface and a good adhesion between the silicon wafer and the thin film aluminum. The oxidation time was controlled by observation of current variation. While the oxalic acid with 0.2 M was used for low voltage anodization under 100 V, the chromic acid with 0.1 M was used for high voltage anodization over 100 V. The nano-sized pores with diameter of $60\~120$ nm was obtained by low voltage anodization of $40\~80$ V and those of $200\~300$ nm was obtained by high voltage anodization of $140\~200$ V. The pore widening process was employed for obtaining the one-channel with flat surface because the pores of the alumina membrane prepared by the fixed voltage method shows the structure of two-channel with rough surface. Finally, the sample was immersed to the phosphoric acid with 0.1 M concentration to etching the barrier layer.

The formation of highly ordered nano pores in Anodic Aluminum Oxide

  • Im, Wan-soon;Cho, Kyung-Chul;Cho, You-suk;Park, Gyu-Seok;Kim, Dojin
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2003년도 춘계학술발표강연 및 논문개요집
    • /
    • pp.53-53
    • /
    • 2003
  • There has been increasing interest in the fabrication of nano-sized structures because of their various advantages and applications. Anodic Aluminum Oxide (AAO) is one of the most successful methods to obtain highly ordered nano pores and channels. Also It can be obtained diverse pore diameter, density and depth through the control of anodization condition. The three types of substrates were used for anodization; sheets of Aluminum on Si wafer and Aluminum on Mo-coated Si wafer. In Aluminum sheet, a highly ordered array of nanoholes was formed by the two step anodization in 0.3M oxalic acid solutions at 10$^{\circ}C$ After the anodization, the remained aluminum was removed in a saturated HgCl$_2$ solution. Subsequently, the barrier layer at the pore bottom was opened by chemical etching in phosphoric acid. Finally, we can obtain the through-channel membrane. In these processes, the effect of various parameters such as anodizing voltage, anodizing time, pore widening time and pre-heat treatment are characterized by FE-SEM (HITACH-4700). The pore size. density and growth rate of membrane are depended on the anodizing voltage and temperature respectively. The pore size is proportional to applied voltage and pore widening time The pore density can be controlled by anodizing temperature and voltage.

  • PDF

열응력이 포천화강암의 투수성에 미치는 영향 (The Effect of the Thermal Stress on the Transport Property of Pocheon Granite)

  • 윤웅균
    • 터널과지하공간
    • /
    • 제7권3호
    • /
    • pp.238-245
    • /
    • 1997
  • A transient pulse methos has been used to measure the permeability of Pocheon granite pre-heated from $25^{\circ}C$ to $600^{\circ}C$ at effective pressure up to 32MPa. The permeability of whole rock ranged from 0.72 $\mu$d at 10MPa to 0.20 $\mu$d at 32MPa. The permeability of rock heated to $600^{\circ}C$ ranged from 18.07$\mu$d at 10MPa to 6.39$\mu$d at 32MPa. Confining pressure has greater effects on the rocks thermally treated to lower thermal-cycle temperatures than on the higher thermally treated rocks. The increase of permeability is most pronounced between 40$0^{\circ}C$ and $600^{\circ}C$. Below 40$0^{\circ}C$, permeability increase is expected to be associated with the formation of new cracks and widening of preexisting cracks, whereas above 40$0^{\circ}C$, permeability increase is expected to reflect widening of cracks. Using the equivalent channel model, author shows that the exponent n in the relationship relating the permebility(k) to porosity($\phi$) by k∝$$\phi$^n$ falls in the range 2.7$\leq$n$\leq$3.0.

  • PDF

Structural and Electrical Properties of an Electrolyte-insulator-metal Device with Variations in the Surface Area of the Anodic Aluminum Oxide Template for pH Sensors

  • Kim, Yong-Jun;Lee, Sung-Gap;Yeo, Jin-Ho;Jo, Ye-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권6호
    • /
    • pp.2364-2367
    • /
    • 2015
  • In this study, we fabricated an electrolyte-insulator-metal (EIM) device incorporating a high-k Al2O3 sensing membrane using a porous anodic aluminum oxide (AAO) through a two-step anodizing process for pH detection. The structural properties were observed by field-emission scanning electron microscopy (FE-SEM) and X-ray diffraction patterns (XRD). Electrochemical measurements taken consisted of capacitance-voltage (C-V), hysteresis voltage and drift rates. The average pore diameter and depth of the AAO membrane with a pore-widening time of 20 min were 123nm and 273.5nm, respectively. At a pore-widening time of 20 min, the EIM device using anodic aluminum oxide exhibited a high sensitivity (56mV/pH), hysteresis voltage (6.2mV) and drift rate (0.25mV/pH).

Systematic Study of Paper Breaks in Papermaking Process Using Fracture Mechanics - (1) Evaluation of Fracture Toughness in Wet State

  • Yung B. Seo;Roh, You-Sun
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2002년도 춘계학술발표논문집
    • /
    • pp.76-84
    • /
    • 2002
  • Fracture toughness was considered as one of the good estimates of the paper break tendency of paper web in the press room. Paper break on the paper machine is caused by many factors such as paper machine irregular vibrations, impurities in the fiber furnish, shives, and so on. On the paper machine, the solid content of paper web is changing very rapidly from less than 1% to over 95%. We tried to measure the fracture toughness of paper web at different solid contents for providing the fundamental knowledge of paper break. Stretches of wet web were also measured and compared to the fracture toughness changes. Four different fiber furnishes (SwBKP, HwBKP, ONP, and OCC) were refined to different degrees, and at different solid contents (40%, 60%, 80%, and 95%), their fracture toughnesses were measured. Two fracture toughness measurement methods (essential work of fracture and Tryding's load-widening method) were used, and we found they gave identical results. The stretch curves of the wet webs against the axis of solid contents were very similar to the fracture toughness curves of those.

  • PDF

양극산화법에 의한 나노와이어 제조I. 알루미나 나노 템플레이트의 특성 (Preparation of Nano Wire by Anodic Oxidation I. Characteristics of Alumina Nano-Template by Anodic Oxidation)

  • 조수행;오한준;박치선;장재명;지충수
    • 한국재료학회지
    • /
    • 제12권2호
    • /
    • pp.121-128
    • /
    • 2002
  • Anodic alumina layer can be used as templates for preparation of nano-structured materials, because porous oxide layer on aluminum shows a uniform pore size and a high pore density. In order to find out possibility for template material to prepare nano wire, the effects of the anodic applied potential, anodic time and the temperature of electrolyte on pore diameter of anodic alumina layer were studied using SEM and AFM. The pore diameter of anodic alumina layer increased with applied anodic potential and electrolytic temperature. Especially, the pore diameter of anodic oxide layers formed in chromic acid can be well replicated by widening process in $H_3$$PO_4$solution.

원판형 연골에서 단순 방사선 검사의 의의 (X-ray Significance in Discoid Meniscus)

  • 안진환;하권익;김형국;김호
    • 대한관절경학회지
    • /
    • 제1권1호
    • /
    • pp.102-107
    • /
    • 1997
  • Discoid meniscus has been well known to a frequent anomaly of meniscus and much reported in diagnosis and treatment. But, associated X-ray findings have not been known well. We reported its significance of X-ray findings in discoid meniscus. From May 1995 to May 1997, 31 cases of discoid meniscus were compared with 51 cases of nondiseoid meniscus both confirmed by arthroscopy, with simple X-my findings. Both groups were evaluated by X-ray findings in view of lateral joint space widening, peripheral spur of lateral joint space, sclerotic change of lateral tibial plateau, concave lateral tibial plateau, flattening of lateral femoral condyle, hypoplasia of lateral femoral condyle and high riding fibula. The results of analysis were as follows: 1. Widening of lateral joint space, sclerotic change of lateral tibial plateau and cupping of lateral tibial plateau were statistically significant in discoid meniscus. 2. X-ray findings in discoid meniscus were not associated with patient's injury history and symptom duration. 3. Other X-ray findings were not related in discoid meniscus significantly. X-ray findings with patient's history and physical examination arc helpful in the diagnosis of discoid meniscus.

  • PDF