• 제목/요약/키워드: widening

검색결과 627건 처리시간 0.024초

Infundibular Widening of Angiographically Invisible Duplicate Anterior Choroidal Artery Mimicking Typical Anterior Choroidal Artery Aneurysm

  • Jaechan, Park;Jong-Soo, Kim
    • Journal of Korean Neurosurgical Society
    • /
    • 제66권1호
    • /
    • pp.105-110
    • /
    • 2023
  • A diagnosis of an intracranial aneurysm depends on the angiographic configuration and should be cautiously differentiated from aneurysm mimics. In cases of duplicate anterior choroidal arteries (AChAs), infundibular widening of the distal minor AChA can be an aneurysm mimic. If the minor AChA with a smaller diameter is obscured angiographically due to poor contrast filling, an associated infundibular widening beside the proximal large AChA can misinterpreted as a typical AChA aneurysm in angiograms. The authors report on two such cases of duplicate AChAs with infundibular widening presenting like a typical AChA aneurysm in angiograms. Surgical exploration revealed a perforating artery emitting from the dome of the saccular lesion, confirming infundibular widening of a duplicate AChA. No reparative procedure was applied to the infundibular widening in a 48-year-old man, while two vascular outpouchings from the infundibular widening were clipped preserving the duplicate AChA in a 55-year-old woman.

Does Second-Generation Suspensory Implant Negate Tunnel Widening of First-Generation Implant Following Anterior Cruciate Ligament Reconstruction?

  • Sundararajan, Silvampatti Ramasamy;Sambandam, Balaji;Singh, Ajay;Rajagopalakrishnan, Ramakanth;Rajasekaran, Shanmuganathan
    • Knee surgery & related research
    • /
    • 제30권4호
    • /
    • pp.341-347
    • /
    • 2018
  • Purpose: Tunnel widening following anterior cruciate ligament (ACL) reconstruction is commonly observed. Graft micromotion is an important contributing factor. Unlike fixed-loop devices that require a turning space, adjustable-loop devices fit the graft snugly in the tunnel. The purpose of this study is to compare tunnel widening between these devices. Our hypothesis is that the adjustable-loop device will create lesser tunnel widening. Materials and Methods: Ninety-eight patients underwent ACL reconstruction from January 2013 to December 2014. An adjustable-loop device was used in 54 patients (group 1) and a fixed-loop device was used in 44 patients (group 2). Maximum tunnel widening at 1 year was measured by the L'Insalata's method. Functional outcome was measured at 2-year follow-up. Results: The mean widening was 4.37 mm (standard deviation [SD], 2.01) in group 1 and 4.09 mm (SD, 1.98) in group 2 (p=0.511). The average International Knee Documentation Committee score was 78.40 (SD, 9.99) in group 1 and 77.11 (SD, 12.31) in group 2 (p=0.563). The average Tegner-Lysholm score was 87.25 (SD, 3.97) in group 1 and 87.29 in group 2 (SD, 4.36) (p=0.987). There was no significant difference in tunnel widening and functional outcome between the groups. Conclusions: The adjustable-loop device did not decrease the amount of tunnel widening when compared to the fixed-loop device. There was no significant difference in outcome between the two fixation devices. Level of Evidence: Level 3, Retrospective Cohort.

의사결정수 기법을 이용한 교량확폭에 관한 의사결정모델 개발 (Decision Making Model for Widening Bridges Using Decision Tree Technique)

  • 조효남;박진형;선종완;윤만근
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권4호
    • /
    • pp.187-194
    • /
    • 2008
  • 도로교량의 경우 급속한 도시화로 인해 증가한 교통량을 처리하기 위해 교량확폭과 신설교량의 추가 건설 등의 방법이 사용되고 있다. 하지만 현재 국내에서는 확폭 또는 신설 교량의 추가건설의 타당성을 판단하기 위한 합리적인 절차나 기준이 마련되어 있지 않다. 또한 교량 확폭 공사 시에는 일반적인 교량신설 공사에 비해 불확실성을 내포한 사건들이 추가적으로 존재한다. 이에 본 논문에서는 의사결정수 방법을 이용해 교량확장에 따라 발생 가능한 사건의 기대 위험비용을 체계적으로 고려할 수 있는 개선된 형태의 생애주기비용 분석 모델을 제안하였다.

Bridge widening with composite steel-concrete girders: application and analysis of live load distribution

  • Yang, Yue;Zhang, Xiaoguang;Fan, Jiansheng;Bai, Yu
    • Advances in concrete construction
    • /
    • 제3권4호
    • /
    • pp.295-316
    • /
    • 2015
  • A bridge widening technology using steel-concrete composite system was developed and is presented in this paper. The widened superstructure system consists of a newly built composite steel-concrete girder with concrete deck and steel diaphragms attached to the existing concrete girders. This method has been applied in several bridge widening projects in China, and one of those projects is presented in detail. Due to the higher stiffness-to-weight ratio and the rapid erection of composite girders, this widening method reveals benefits in both mechanical performance and construction. As only a few methods for the design of bridges with different types of girders are recommended in current design codes, a more accurate analytical method of estimating live load distribution on girder bridges was developed. In the analytical model, the effects of span length, girder pacing, diaphragms, concrete decks were considered, as well as the torsional and flexural stiffness of both composite box girders and concrete T girders. The study shows that the AASHTO LRFD specification procedures and the analytical models proposed in this paper closely approximate the live load distribution factors determined by finite element analysis. A parametric study was also conducted using the finite element method to evaluate the potential load carrying capacities of the existing concrete girders after widening.

The Effects of Widening Daily Stock Price Limits on the Relevance between Audit Quality and Stock Return

  • JI, Sang-Hyun;YOON, Ki-Chang
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제7권4호
    • /
    • pp.107-119
    • /
    • 2020
  • The study investigates the effect of the widened daily stock price limits on the usefulness of accounting information in Korea: 1) whether investors place a higher importance on audit quality, an indicator of the reliability of accounting information, and 2) whether there are differences in the relationships between audit quality and stock-price earning-rates two years before and after June 15, 2016. This study employs samples of two years (2013 to 2015) before the widening and two years after the widening (2016 to 2017). The samples are limited to the companies listed on the Korea Stock Exchange, accounting settled in December, collected from Fn-Guide and TS-2000 of the Korea Listed Companies Association. The results show that the positive association between audit quality and stock return was increased during the later period, compared to the preceding period. This tendency was more evident in companies with higher debt ratios and companies with lower levels of income smoothing, which is considered to have higher risks. The findings suggest that it is the first study evaluating the effect of widening daily stock price limits, made on June 15, 2015, on the usefulness of audit quality information by examining the relevance between audit quality and stock return.

원위 경비 인대 결합 고정 긴장도와 기간이 나사못 제거 후 이개 및 임상 증상에 미치는 영향 (The Impacts of Fixation Tightness and Duration on the Remnant Syndesmotic Widening and Clinical Symptom after Removal of Screws)

  • 배서영;손수인;성민규
    • 대한족부족관절학회지
    • /
    • 제17권4호
    • /
    • pp.264-271
    • /
    • 2013
  • Purpose: We aimed to analyze the effect of fixation tightness of the syndesmotic screw and its indwelling period on the recurrence of the syndesmosis widening after screw removal and the clinical outcomes. Materials and Methods: Forty consecutive patients with acute syndesmotic injury were retrospectively reviewed. The tibiofibular clear space is measured by digitalized measurement tool on serial radiographs. We analyzed the effect of time from trauma to fixation, syndesmotic screw indwelling duration, and fixation methods. Residual symptoms at the last follow up were evaluated. The student t-test, correlation test, and chi-square test were used for statistical analysis. Results: Eighteen ankles (45%) had recurrent syndesmosis widening (greater than 5% compared to the contralateral side). Seven patients had pain and five had limitation of motion in the ankle joint. Fixation tightness had significant effect on reducing the recurrence while the severity of the initial widening, time to fixation, and duration of fixation did not affect the outcome. Conclusion: Tight fixation of syndesmotic screw is essential for achieving final syndesmotic stability and reducing recurrence.

Common conditions associated with mandibular canal widening: A literature review

  • Mortazavi, Hamed;Baharvand, Maryam;Safi, Yaser;Dalaie, Kazem;Behnaz, Mohammad;Safari, Fatemeh
    • Imaging Science in Dentistry
    • /
    • 제49권2호
    • /
    • pp.87-95
    • /
    • 2019
  • Purpose: The aim of this study was to review the common conditions associated with mandibular canal widening. Materials and Methods: General search engines and specialized databases including Google Scholar, PubMed, PubMed Central, Science Direct, and Scopus were used to find relevant studies by using the following keywords: "mandibular canal," "alveolar canal," "inferior alveolar nerve canal," "inferior dental canal," "inferior mandibular canal," "widening," "enlargement," "distension," "expansion," and "dilation." Results: In total, 130 articles were found, of which 80 were broadly relevant to the topic. We ultimately included 38 articles that were closely related to the topic of interest. When the data were compiled, the following 7 lesions were found to have a relationship with mandibular canal widening: non-Hodgkin lymphoma, osteosarcoma, schwannoma, neurofibroma, vascular malformation/hemangioma, multiple endocrine neoplasia syndromes, and perineural spreading or invasion. Conclusion: When clinicians encounter a lesion associated with mandibular canal widening, they should immediately consider these entities in the differential diagnosis. Doing so will help dentists make more accurate diagnoses and develop better treatment plans based on patients' radiographs.

Nano-engineering of Hybrid Titanium Oxide Structure (TiO2) using Pore-widening Concentration for Enhanced Superhydrophilicity

  • Yeji Choi;Chanyoung Jeong
    • Corrosion Science and Technology
    • /
    • 제23권1호
    • /
    • pp.41-53
    • /
    • 2024
  • Titanium alloy is gaining attention in the medical industry due to its excellent biocompatibility and osteoconductivity. However, the natural oxide film on the titanium surface is insoluble, resulting in inadequate bone adhesion. Therefore, it is necessary to optimize the contact between biological tissues and implant surfaces, and alter the chemical composition and morphological characteristics of the implant surface. In this study, the anodization method was applied to titanium surface treatment to form a uniform and robust oxide film. Subsequently, a chemical process, pore-widening, was employed to change the morphological characteristics of the oxide film. The concentration of the pore-widening solution was varied at 2, 4, 6, and 8 wt% and the process time was set at 30 and 60 minutes. As the concentration of the pore-widening solution increased the pore diameter of the oxide film increased. Notably, at 6 wt% for 60 minutes, the oxide film exhibited a coexistence of pillars and pores. Based on this, it was determined that surface roughness increased with higher concentration and longer process time. Additionally, the presence of pillars and pores structures maximized hydrophilicity. This study provides insights into enhancing the surface properties of titanium for improved performance in medical implants.

Review of common conditions associated with periodontal ligament widening

  • Mortazavi, Hamed;Baharvand, Maryam
    • Imaging Science in Dentistry
    • /
    • 제46권4호
    • /
    • pp.229-237
    • /
    • 2016
  • Purpose: The aim of this article is to review a group of lesions associated with periodontal ligament (PDL) widening. Materials and Methods: An electronic search was performed using specialized databases such as Google Scholar, PubMed, PubMed Central, Science Direct, and Scopus to find relevant studies by using keywords such as "periodontium", "periodontal ligament", "periodontal ligament space", "widened periodontal ligament", and "periodontal ligament widening". Results: Out of nearly 200 articles, about 60 were broadly relevant to the topic. Ultimately, 47 articles closely related to the topic of interest were reviewed. When the relevant data were compiled, the following 10 entities were identified: occlusal/orthodontic trauma, periodontal disease/periodontitis, pulpo-periapical lesions, osteosarcoma, chondrosarcoma, non-Hodgkin lymphoma, progressive systemic sclerosis, radiation-induced bone defect, bisphosphonate-related osteonecrosis, and osteomyelitis. Conclusion: Although PDL widening may be encountered by many dentists during their routine daily procedures, the clinician should consider some serious related conditions as well.

임상가를 위한 특집 2 - 하악골의 외과적 확장 (Mandibular Symphysis Transverse Widening)

  • 오승환
    • 대한치과의사협회지
    • /
    • 제51권6호
    • /
    • pp.313-321
    • /
    • 2013
  • The most common orthodontic methods of treating mandibular transverse deficiencies is extractions, interdental stripping, and other dento-alveolar compensation but it can not addressesd about skeletal problem This study assessed the treatment outcomes after surgically assisted rapid tooth orthodontics using the symphysis osteotomy and dentoalveolar distraction osteogenesis technique. The applications of distraction osteogenesis in mandibular widening, by symphysis osteotomy, has emerged as a definitive, predictable and better stability. The most important factors in mandibular widening is performed with simple surgical technique and devices. As a results, these techniques are very useful and effective in cases of difficult tooth movement in adult orthodontics transverse problems There were few intraoperative or postoperative complications and were not clinically significant.