• Title/Summary/Keyword: wide load range

Search Result 414, Processing Time 0.044 seconds

A Buck Converter with PLL-based PWM/PFM Integrated Control (PLL 기반 PWM/PFM 통합 제어 방식의 벅 컨버터)

  • Heo, Jung;Jeong, Hang-Geun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.8
    • /
    • pp.35-40
    • /
    • 2012
  • In DC-DC converters, a PWM/PFM dual mode control method is commonly used to maintain a high efficiency over a wide range of load variation. Since the control mode is selected according to the load condition, the chip area is increased due to additional circuit for mode control and the optimum efficiency cannot be achieved around the mode transition point. To solve such problems, a new integrated control method is proposed in this paper, in which a PLL is used in the current mode PWM control circuit instead of an oscillator. The proposed integrated control method is verified through a design of a buck converter using PSIM simulation. Simulation of the complete buck converter circuit by Cadence Spectre showed a maximum efficiency of 94.7% at a load current of 250mA and an efficiency of 85.4% at a load current of 10mA under the light load condition.

Design of LLC Resonant Converter having Enhanced Load Range for Communication Power (넓은 부하 범위를 갖는 통신 전원용 LLC 공진 컨버터의 설계)

  • So, Byong-Chul;Seo, Ki-Bong;Lee, Dong-Hoo;Jung, Ho-Chul;Hwang, Soon-Sang;Kim, Hag-Wone;Cho, Kwan-Yuhl;Lim, Byung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.461-469
    • /
    • 2012
  • This paper deals with LLC resonant converter for communication power supply. Generally, the load range of communication power is very wide. However, voltage conversion ratio of LLC converter is highly dependent of load condition. So, it is not easy to design of robust power supply along with the wide load condition. Especially, it is not possible to meet the required low voltage conversion ratio for low output voltage with high input voltage under the light load condition. To solve this problem, in this paper, a new duty control interlinked with operational frequency has been proposed. To prove the usefulness of the proposed control method, the simulation and experiments were carried out. The simulation and experimental results show the usefulness of the proposed control method.

A Design of Wide-Bandwidth LDO Regulator with High Robustness ESD Protection Circuit

  • Cho, Han-Hee;Koo, Yong-Seo
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1673-1681
    • /
    • 2015
  • A low dropout (LDO) regulator with a wide-bandwidth is proposed in this paper. The regulator features a Human Body Model (HBM) 8kV-class high robustness ElectroStatic Discharge (ESD) protection circuit, and two error amplifiers (one with low gain and wide bandwidth, and the other with high gain and narrow bandwidth). The dual error amplifiers are located within the feedback loop of the LDO regulator, and they selectively amplify the signal according to its ripples. The proposed LDO regulator is more efficient in its regulation process because of its selective amplification according to frequency and bandwidth. Furthermore, the proposed regulator has the same gain as a conventional LDO at 62 dB with a 130 kHz-wide bandwidth, which is approximately 3.5 times that of a conventional LDO. The proposed device presents a fast response with improved load and line regulation characteristics. In addition, to prevent an increase in the area of the circuit, a body-driven fabrication technique was used for the error amplifier and the pass transistor. The proposed LDO regulator has an input voltage range of 2.5 V to 4.5 V, and it provides a load current of 100 mA in an output voltage range of 1.2 V to 4.1 V. In addition, to prevent damage in the Integrated Circuit (IC) as a result of static electricity, the reliability of IC was improved by embedding a self-produced 8 kV-class (Chip level) ESD protection circuit of a P-substrate-Triggered Silicon Controlled Rectifier (PTSCR) type with high robustness characteristics.

A High Efficiency Power Conversion Circuit with Wide ZVS Range for Large Screen PDP Sustaining Power Module (넓은 영전압 스위칭 범위를 갖는 대화면 PDP용 유지전원단을 위한 고효율 전력 변환회로)

  • Park Kyung-Hwa;Moon Gun-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.578-586
    • /
    • 2005
  • Recently, due to the launch of digital broadcasting service, the demand of Flat Panel Display (FPD) is sharply rising. Among them, the PDP is expected to be one of the most promising digital displays of next generation because of its large screen size, high resolution, thinness and board field of view. Meanwhile, the PDP uses ADS (Address Display-period Separation) scheme which divide one subfield into address and sustaining period to express the grey scale of images. Since the output of sustaining power module Is mostly used for sustaining period, the load of the sustaining power module can be considered as a pulsating load. Due to this particular load condition, if the wide ZVS range of the power switches is not guaranteed, the hard switching causes large amount of switching loss and serious thermal problem in power module. In this paper, a high efficiency power conversion circuit for 60' PDP sustaining power module which achieves wide ZVS range with the help of additional ZVS tank is proposed. According to the various gating methods, the different operations of the proposed converter are presented. And, to confirm the properties of the proposed converter, an experimental prototype of 900W power converter is constructed md tested. As a result, more than $92\%$ of high efficiency is obtained at $10\%$ load condition, and the ZVS operation is achieved from full load to $10\%$ load condition.

Analysis on the Analog Filter Design and the Effect of Load for BLDCM Sensorless Drive (브러시리스 직류 전동기의 센서리스 구동시 부하 변동에 따른 회전자 위치 오차 분석과 아날로그 필터의 설계)

  • Kim Young-il;Kim Jong-Sun;Jang Jae-Hoon;Yoo Ji-Yoon;Kim Dong-Sik
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.660-664
    • /
    • 2004
  • The indirect rotor position detection method using terminal voltage of brushless DC motor (BLDCM) requires simple control circuit, and has wide speed range of sensorless operation. However, because the substantial phase difference exists between real back emf and terminal voltage, the existing indirect detection method using analog filter which is affected by frequency, speed, and load sensitively cannot be synchronized with current, in the end, it advances or delays. This paper presents new analog filter circuit design for rotor position estimation in order to solve the problem, and proposes novel sensorless operation method which is stable even in high speed range and not influenced by parameters with analysis on phase difference by load and speed. Moreover, the appropriateness of the proposed sensorless drive in this paper is verified and analyzed by experimentation.

  • PDF

A Study on the Rail Pone of Transition Curve Track to Speed Up of Tilting train (틸팅차량 완화곡선 증속 주행시 궤도작용력 검토)

  • Shin, Tae-Hyoung;Choi, Jung-Youl;Eum, Ki-Young;Park, Yong-Gul
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.529-538
    • /
    • 2009
  • A trial run of locally-developed tilting train has been in process on Chungbuk line since the test vehicle was first produced. For the system stabilization, interface verification among the systems including track, structure, catenary and signaling system, not to mention the rolling stock, is very crucial. Therefore, in this study, the dynamic rail force of the tilting (Hanvit 200), high-speed (KTX) and general (Mugunghwa) vehicle caused by driving in transition curve track was measured. And, it compared the tilting response with the other by using the measured wheel load data in transition curve track, and then evaluated probability the range of wheel load fluctuation for the variable dynamic vertical and lateral wheel load. As a result, a range of wheel load by occured a change of cant from the high-speed and general vehicle which had fixed bogie structure was distributed throughout small deviation (${\Delta}8{\sim}13kN$). Otherwise, in case of the tilting train which was consisted of the pendulum bogie structure was distributed wide range about large deviation (${\Delta}25{\sim}28kN$) by changed of cant.

  • PDF

Load-adaptive 180-Degree Sinusoidal Permanent-Magnet Brushless Motor Control Employing Automatic Angle Compensation

  • Kim, Minki;Oh, Jimin;Suk, Jung-Hee;Heo, Sewan;Yang, Yil Suk
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.2 no.5
    • /
    • pp.310-316
    • /
    • 2013
  • This paper reports a sinusoidal $180^{\circ}$ drive for a permanent magnet (PM) brushless motor employing automatic angle compensator to suppress the driving loss during the wide-range load operation. The proposed drive of the sinusoidal $180^{\circ}$ PM Brushless motor reduced the amplitude of the 3-phase current by compensating for the lead-angle of the fundamental waves of the 3-phase PWM signal. The conventional lead-angle method was implemented using the fixed angle or memorized table, whereas the proposed method was automatically compensated by calculating the angle of the current and voltage signal. The algorithm of the proposed method was verified in a 30 W PM brushless motor system using a PSIM simulator. The efficiency of the conventional method was decreased 90 % to 60 %, whereas that of proposed method maintained approximately 85 % when the load shift was 0 to $0.02N{\cdot}m$. Using an FPGA prototype, the proposed method was evaluated experimentally in a 30 W PM brushless motor system. The proposed method maintained the minimum phase RMS current and 79 % of the motor efficiency under 0 to $0.09N{\cdot}m$ load conditions. The proposed PM brushless motor driving method is suitable for a variety of applications with a wide range of load conditions.

  • PDF

Design Consideration of Half-Bridge LLC Resonant Converter

  • Choi, Hang-Seok
    • Journal of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.13-20
    • /
    • 2007
  • LLC resonant converters display many advantages over the conventional LC series resonant converter such as narrow frequency variation over wide range of load and input variation and zero voltage switching even under no load conditions. This paper presents analysis and design consideration for the half bridge LLC resonant converter. Using the fundamental approximation, the gain equation is obtained, where the leakage inductance in the transformer secondary side is also considered. Based on the gain equation, the practical design procedure is investigated to optimize the resonant network for a given input/output specifications. The design procedure is verified through an experimental prototype of the 115W half-bridge LLC resonant converter.

Compressive behavior of short fibrous reinforced concrete members with square cross-section

  • Campione, G.
    • Structural Engineering and Mechanics
    • /
    • v.37 no.6
    • /
    • pp.649-669
    • /
    • 2011
  • In this paper an analytical model is presented that addresses the compressive response of short-fiber reinforced concrete members (FRC) with hooked steel fibers. This model is applicable to a wide range of concrete strengths and accounts for the interaction between the cover spalling and the concrete core confinement induced by transverse steel stirrups and also for buckling of longitudinal reinforcing bars. The load-shortening curves generated here analytically fit existing experimental data well.

The Experimental Parameter Identification of Electro-Hydraulic Servo Control System (유압 서어보 제어 시스템의 설계 변수 결정의 실험적 고찰)

  • 김영대;강석종;이관섭
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.957-961
    • /
    • 1991
  • The parameters of electro-hydraulic servo system are closely dependent on the variation of system characteristics. Especially the parameter sensitivity is incleased in the servo system with heavy load and wide operating range. This paper shows the effect of parameter variation and the experimental parameter values of high power servo system.

  • PDF