• Title/Summary/Keyword: wide fault

Search Result 166, Processing Time 0.03 seconds

Analysis of Power System Wide-Area Blackout based on the Fault Cascading Scenarios (고장파급 시나리오에 기초한 광역정전 해석기법 연구)

  • Park, Chan-Eom;Kwon, Byeong-Gook;Yang, Won-Young;Lee, Seung-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.155-163
    • /
    • 2008
  • This paper presents a novel framework for analysis of power system wide-area blackout based on so called fault cascading scenarios. For a given power system operating state, "triggering" faults or a "seed faults" are chosen based on the probabilities estimated from the hazard rates. The fault probabilities reflect both the load and the weather conditions. Effects of hidden failures in protection systems are also reflected in establishing the fault propagation scenarios since they are one of the major causes for the wide-area blackouts. A tree type data structure called a PS-BEST(Power System Blackout Event Scenario Tree) is proposed for construction of the fault cascading scenarios, in which nodes represent various power system operating states and the arcs are the events causing transitions between the states. Arcs can be either probabilistic or deterministic. For a given initial fault, the total probability of leading to wide-area blackout is estimated by aggregating the individual probability of each fault sequence route leading to wide-area blackout. A case study is performed on the IEEE RTS-79(24 bus) system based on the fault data presented by the North American Electrical Reliability Council(NERC). Test results demonstrate the potentials and the effectiveness of the proposed technique for the future wide-area blackout analysis.

Performance Assessment of GBAS Ephemeris Monitor for Wide Faults (Wide Fault에 대한 GBAS 궤도 오차 모니터 성능 분석)

  • Junesol Song;Carl Milner
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.13 no.2
    • /
    • pp.189-197
    • /
    • 2024
  • Galileo is a European Global Navigation Satellite System (GNSS) that has offered the Galileo Open Service since 2016. Consequently, the standardization of GNSS augmentation systems, such as Satellite Based Augmentation System (SBAS), Ground Based Augmentation System (GBAS), and Aircraft Based Augmentation System (ABAS) for Galileo signals, is ongoing. In 2023, the European Union Space Programme Agency (EUSPA) released prior probabilities of a satellite fault and a constellation fault for Galileo, which are 3×10-5 and 2×10-4 per hour, respectively. In particular, the prior probability of a Galileo constellation fault is significantly higher than that for the GPS constellation fault, which is defined as 1×10-8 per hour. This raised concerns about its potential impact on GBAS integrity monitoring. According to the Global Positioning System (GPS) Standard Positioning Service Performance Standard (SPS PS), a constellation fault is classified as a wide fault. A wide fault refers to a fault that affects more than two satellites due to a common cause. Such a fault can be caused by a failure in the Earth Orientation Parameter (EOP). The EOP is used when transforming the inertial axis, on which the orbit determination is based, to Earth Centered Earth Fixed (ECEF) axis, accounting for the irregularities in the rotation of the Earth. Therefore, a faulty EOP can introduce errors when computing a satellite position with respect to the ECEF axis. In GNSS, the ephemeris parameters are estimated based on the positions of satellites and are transmitted to navigation satellites. Subsequently, these ephemeris parameters are broadcasted via the navigation message to users. Therefore, a faulty EOP results in erroneous broadcast ephemeris data. In this paper, we assess the conventional ephemeris fault detection monitor currently employed in GBAS for wide faults, as current GBAS considers only single failure cases. In addition to the existing requirements defined in the standards on the Probability of Missed Detection (PMD), we derive a new PMD requirement tailored for a wide fault. The compliance of the current ephemeris monitor to the derived requirement is evaluated through a simulation. Our findings confirm that the conventional monitor meets the requirement even for wide fault scenarios.

A Novel Online Multi-section Weighed Fault Matching and Detecting Algorithm Based on Wide-area Information

  • Tong, Xiaoyang;Lian, Wenchao;Wang, Hongbin
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2118-2126
    • /
    • 2017
  • The large-scale power system blackouts have indicated that conventional protection relays that based on local signals cannot fit for modern power grids with complicated setting or heavily loaded-flow transfer. In order to accurately detect various faulted lines and improve the fault-tolerance of wide-area protection, a novel multi-section weighed fault matching and detecting algorithm is proposed. The real protection vector (RPV) and expected section protection vectors (ESPVs) for five fault sections are constructed respectively. The function of multi-section weighed fault matching is established to calculate the section fault matching degrees between RPV and five ESPVs. Then the fault degree of protected line based on five section fault degrees can be obtained. Two fault detecting criterions are given to support the higher accuracy rate of detecting fault. With the enumerating method, the simulation tests illustrate the correctness and fault-tolerance of proposed algorithm. It can reach the target of 100% accuracy rate under 5 bits error of wide-area protections. The influence factors of fault-tolerance are analyzed, which include the choosing of wide-area protections, as well as the topological structures of power grid and fault threshold.

Algorithm for Fault Detection and Classification Using Wavelet Singular Value Decomposition for Wide-Area Protection

  • Lee, Jae-Won;Kim, Won-Ki;Oh, Yun-Sik;Seo, Hun-Chul;Jang, Won-Hyeok;Kim, Yoon Sang;Park, Chul-Won;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.729-739
    • /
    • 2015
  • An algorithm for fault detection and classification method for wide-area protection in Korean transmission systems is proposed. The modeling of 345-kV and 765-kV Korean power system transmission networks using the Electro Magnetic Transient Program - Restructured Version (EMTP-RV) is presented and the algorithm for fault detection and classification in transmission lines is developed. The proposed algorithm uses the Wavelet Transform (WT) and Singular Value Decomposition (SVD). The Singular value of Approximation coefficient (SA) and part Sum of Detail coefficient (SD) are introduced. The characteristics of the SA and SD at the fault conditions are analyzed and used in the algorithm for fault detection and classification. The validation of the proposed algorithm is verified by various simulation results.

Double-Input DC-DC Converter for Applications with Wide-Input-Voltage-Ranges

  • Hu, Renjun;Zeng, Jun;Liu, Junfeng;Yang, Jinming
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1619-1626
    • /
    • 2018
  • The output power of most facilities for renewable energy generation is unstable due to external environmental conditions. In distributed power systems with two or more sources, a stable output can be achieved with the complementary power supply among the different input sources. In this paper, a double-input DC-DC converter with a wide-input-voltage-range is proposed for renewable energy generation. This converter has the following advantages: the circuit is simple, and the input voltage range is wide and the fault tolerance is excellent. The operation modes and the steady-state analysis are examined. Finally, experimental results are illustrated to verify the correctness of the analysis and the feasibility of the proposed converter.

Analysis on Fault-Related Landformsin the Gyeongju Area of the Yangsan Fault Valley (양산 단층곡 경주 지역의 단층 지형 분석)

  • Park, Chung-Sun;Lee, Gwang-Ryul
    • Journal of The Geomorphological Association of Korea
    • /
    • v.25 no.1
    • /
    • pp.19-30
    • /
    • 2018
  • This study tries to infer fault lines and produce a map for the lines based on a classification of fault-related landforms and fluvial landformsin the Gyeongju area of the Yangsan Fault Valley. Fault activities in the study area are thought to be older than the time of river formation or stronger than the erosion by river, while the northern and southern parts of the study area seem to have experienced fault activities after valley formation. It is also possible that weaker fault activities than the erosion by river seem to have been prevailed in the parts. In the study area, the Gyeongju alluvial fan is located within a wide erosional valley at the joint area of the Yangsan and Ulsan Faults. From the distribution of the landforms, it is inferred that several fault lines parallel to the Yangsan Fault are distributed at both sides of the fault valley. In particular, the area from Bae-dong to Nogok-ri, Naenam-myeon shows the most obvious linearity of the landforms within the study area. Several fault lines with a direction of NNE-SSW are also found around the epicenter of the 2016 Gyeongju Earthquake.

Frequency Estimation Method using Recursive Discrete Wavelet Transform for Fault Disturbance Recorder (FDR를 위한 RDWT에 의한 주파수 추정 기법)

  • Park, Chul-Won;Ban, Yu-Hyeon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1492-1501
    • /
    • 2011
  • A wide-area protection intelligent technique has been used to improve a reliability in power systems and to prevent a blackout. Nowadays, voltage and current phasor estimation has been executed by GPS-based synchronized PMU, which has become an important way of wide-area blackout protection for the prevention of expending faults in power systems. As this technique has the difficulties in collecting and sharing of information, there have been used a FNET method for the wide-area intelligent protection. This technique is very useful for the prediction of the inception fault and for the prevention of fault propagation with accurate monitoring frequency and frequency deviation. It consists of FDRs and IMS. It is well known that FNET can detect the dynamic behavior of system and obtain the real-time frequency information. Therefore, FDRs must adopt a optimal frequency estimation method that is robust to noise and fault. In this paper, we present comparative studies for the frequency estimation method using IRDWT(improved recursive discrete wavelet transform), for the frequency estimation method using FRDWT(fast recursive discrete wavelet transform). we used the Republic of Korea 345kV power system modeling data by EMTP-RV. The user-defined arbitrary waveforms were used in order to evaluate the performance of the proposed two kinds of RDWT. Also, the frequency variation data in various range, both large range and small range, were used for simulation. The simulation results showed that the proposed frequency estimation technique using FRDWT can be the optimal frequency measurement method applied to FDRs.

Realization of a Web based Remote Monitoring Server for SMD In Line System (SMD 조립 설비의 웹기반 원격 관리 서버 구축)

  • Lim, S. J.;Park, K. T.;Lyou, J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.529-532
    • /
    • 2001
  • A Remote Monitoring Server(RMS) server which uses Internet and World Wide Web is constructed for SMD in-line system. Hardware base consists of server computer, virtual SMD in-line system and other computers. Software includes assignment of server, RDBMS and various modules in server home page. Web browser provide production quantity, bad PCB quantity, error number and error message in virtual SMD module, user information in setup module, detailed error information in fault diagnosis module, fault history in fault history module and customer information in customer service management module. These functions of the RMS helps a decrease of non-operation time and a service response as fast as possible.

  • PDF

Interpretation of recent topographic changes using the DEM data in the eastern part of Ulsan fault zone (DEM자료를 이용한 울산단층대 동부지역의 최근 지형변화 해석)

  • 신정환;최원학;장천중
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.09a
    • /
    • pp.11-18
    • /
    • 2002
  • The Ulsan fault with NNW-SSE strike is a very wide and long lineament about 50km along Gyeungju-Ulsan line in the southeastern part of Korea. According to previous studies the Ulsan fault was not considered as a fault but only long lineament since no displacement was found along the lineament. Recently several Quaternary faults were reported in the northeastern part of lineament, which implies the neotectonic movement in this area. We analysed drainage pattern and stream gradient using the DEM (Digital Elevation Model) data for both side of Ulsan fault line to check the recent topographic changes which indicate neotectonic movement. The result shows that stream index in the eastern part of Ulsan fault is higher than the one in the western part. This means that recent tectonic movement is more active in the eastern part of Ulsan fault.

  • PDF

Fault Detection and lsolation System for centrifugal-Pump Systems: Parity Relation Approach (원심펌프 계통의 고장검출진단시스템 : 등가관계 접근법)

  • Park, Tae-Geon;Lee, Kee-Sang
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.1
    • /
    • pp.52-60
    • /
    • 1999
  • This paper deals with a fault detection and isolation scheme for a DC motor driven centrifugal pump system. The emphasis is placed on the design and implementation of the residual generatorm, based on parity relation, that provides decision logic unit with residuals that will be further processed to detect and isolate three important faults in the system;brush fault, impeller fault, and the speed sensor fault. Two process faults are modelled as multiplicative type faults, while the sensor fault as an additive one. With multiplicative fault, the implementation of the residual generator needs the time varying transformation matrix that must be computed on-line. Typical implementation methods lack in generality because only a numerical approximation around the assumed fault levels is employed. In this paper, a new implementation method using well tranined neural network is proposed to improve the generality of the residual generator. Application results show that the fault detection and isolation scheme with the proposed residual generator effectively isolates three major faults in the centrifugal pump system even with a wide range of fault magnitude.

  • PDF