• Title/Summary/Keyword: wetting properties

Search Result 268, Processing Time 0.023 seconds

The Effect of Interfacial Properties and RTM Process of Composites with Different Cross-linking Density by Molecular Weight of Hardener (경화제의 분자량에 의한 가교밀도 차이에 따른 복합재료의 계면 물성 및 RTM 성형성에 미치는 영향)

  • Park, Ha-Seung;Shin, Pyeong-Su;Kim, Jong-Hyun;Baek, Yeong-Min;Kwon, Dong-Jun;Park, Joung-Man
    • Composites Research
    • /
    • v.30 no.3
    • /
    • pp.169-174
    • /
    • 2017
  • Demand of glass fiber reinforced composites (GFRC) increased with developing aircraft and defense industries using resin transfer molding (RTM) process to produce complex product. In this research, wetting, interfacial, and mechanical properties were evaluated with different Cross-linking Density by Molecular Weight of Hardener. Epoxy resin as matrices was used bisphenol-A type and amine-type hardeners with different molecular weight. Specimens were manufactured via RTM and wetting property of resin and glass fiber (GF) mat was evaluated to viscosity of epoxy and injection time of epoxy matrix. Mechanical property of GFRC was determined via flexural strength whereas interfacial properties were determined by interlaminar shear strength (ILSS) and interfacial shear strength (IFSS). The difference in mechanical property depends upon the fiber weight fraction (wt %) of GFRC by RTM as well as the different Molecular Weight of Hardener.

Effect of Clamping Pressure on Surface Properties of Gas Diffusion Layer in PEFCs (체결압이 고분자연료전지 기체확산층의 표면성질에 미치는 영향)

  • Ahn, Eun-Jin;Park, Gu-Gon;Yoon, Young-Gi;Park, Jin-Soo;Lee, Won-Yong;Kim, Chang-Soo
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.4
    • /
    • pp.306-310
    • /
    • 2007
  • Characteristics of GDL (Gas Diffusion Layer) mainly determine the gas diffusion and water removal in a cell, thereby changing the performance and affecting durability of PEFC. To optimize the water management and understand the two phase flow in a GDL, it is important to study the behaviors of GDL micro structure under the real operating condition. In the clamped condition of cell, the GDL beneath the rib is more compressed than beneath the channel. Many researches on physical, electrochemical, mechanical behaviors of gas diffusion layer has been conducted. However, changes in surface properties under clamped condition have rarely studied. In present study, the morphology of broken connections of carbon fibers and detachment of PTFE coatings on the fibers were shown from the microscopic observations. In addition, changes in wetting properties of GDL by compression were investigated by using XPS and liquid uptake methods. The hydrophobic characteristics of GDL surface beneath the rib of the flow field plate are changed due to the deformation of micro structure.

Proposal of Design Method for Landslides Considering Antecedent Rainfall and In-situ Matric Suction (선행강우와 현장 모관흡수력을 고려한 산사태 해석 방법 제안)

  • Kim, Jung-Hwan;Jeong, Sang-Seom;Kim, Yong-Min;Lee, Kwang-Woo
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.12
    • /
    • pp.11-24
    • /
    • 2013
  • This study presents a design method for typical rainfall-induced landslide considering in-situ matric suction. Actual landslide data are used to validate the proposed method. The soil-water characteristic curve (SWCC) and unsaturated permeability are experimentally determined to estimate hydraulic properties of testing site. The field measurement of matric suction is carried out to monitor in-situ matric suction in a natural slope subjected to rainfall infiltration, which is incorporated in the landslide analysis. The wetting band depth and safety factor of the slope are assessed to clarify the effect of domestic rainfall pattern. Especially, the effect of antecedent rainfall on the slope stability is investigated and discussed in terms of wetting band depth using parametric study. It is found from the result of this study that proposed design method can consider the characteristic of unsaturated soil and effect of antecedent rainfall. The location of the scarp zone is fairly well predicted by proposed design method. Moreover, heavy rainfall, concentrated in the backward part with time, causes the lowest safety factor of the slope. These results demonstrate that decrease in matric suction due to antecedent rainfall may trigger slope instability. After the antecedent rainfall, additional rainfall may cause the slope failure due to increasing wetting band depth.

Bioactive characteristics of an implant surface coated with a pH buffering agent: an in vitro study

  • Pae, Hyung-Chul;Kim, Su-Kyoung;Park, Jin-Young;Song, Young Woo;Cha, Jae-Kook;Paik, Jeong-Won;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.6
    • /
    • pp.366-381
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate the effectiveness of conventional sandblasted, large-grit, acid-etched (SLA) surface coated with a pH buffering solution based on surface wettability, blood protein adhesion, osteoblast affinity, and platelet adhesion and activation. Methods: Titanium discs and implants with conventional SLA surface (SA), SLA surface in an aqueous calcium chloride solution (CA), and SLA surface with a pH buffering agent (SOI) were prepared. The wetting velocity was measured by the number of threads wetted by blood over an interval of time. Serum albumin adsorption was tested using the bicinchoninic acid assay and by measuring fluorescence intensity. Osteoblast activity assays (osteoblast adhesion, proliferation, differentiation, mineralization, and migration) were also performed, and platelet adhesion and activation assays were conducted. Results: In both the wetting velocity test and the serum albumin adsorption assay, the SOI surface displayed a significantly higher wetting velocity than the SA surface (P=0.000 and P=0.000, respectively). In the osteoblast adhesion, proliferation, differentiation, and mineralization tests, the mean values for SOI were all higher than those for SA and CA. On the osteoblast migration, platelet adhesion, and activation tests, SOI also showed significantly higher values than SA (P=0.040, P=0.000, and P=0.000, respectively). Conclusions: SOI exhibited higher hydrophilicity and affinity for proteins, cells, and platelets than SA. Within the limits of this study, it may be concluded that coating an implant with a pH buffering agent can induce the attachment of platelets, proteins, and cells to the implant surface. Further studies should be conducted to directly compare SOI with other conventional surfaces with regard to its safety and effectiveness in clinical settings.

A Study on Improvement of Wettability and Comfort in Contact lens with Hyaluronic acid (Hyaluronic acid 함유 콘택트렌즈의 습윤성과 착용감 향상 효과 연구)

  • Kim, Hyun Jung;Kim, Soo-Hyun;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.255-264
    • /
    • 2011
  • Purpose: To study the effect of hyaluronic acid(HA), which was widely used in artificial tears, multi-purpose solution(MPS), cosmetics, and drug acting on the musculo-skeletal system, in wettability and comfort of contact lens, we compared HA including lens(+HA) with HA excluding lens(-HA) by clinical evaluation. Methods: During four weeks, the selected 28 university student volunteers who did not have any eye disease wore +HA contact lens on their right eyes, and -HA contact lens on their left eyes, and then compared right eyes to left eyes as control. After prescribing by spherical equivalent calculation, over-refraction by auto-refractometer, and contact lens wearing for two weeks and four weeks, tear evaluation, the anterior of eyes examination, fitting convenience evaluation, surface wetting test, surveys were checked up. Results: Compared with the control group (-HA contact lens), +HA contact lens provided better wetting properties. The amount of released tear in -HA contact lens group became less in four weeks than before, but that in +HA contact lens group showed no significant difference from the initial one. In terms of the redness in eye, there was no significant difference between +HA and -HA contact lens groups. Fitting of +HA contact lens on eye was much easier than the control, -HA contact lens. From the results of survey, comfort, wettability, ease of cleaning, and dryness of eye in +HA contact lens group were generally better than those of -HA group, but redness and contact lens handling showed little difference. Conclusions: The addition of HA in soft contact lens(+HA) may enhance the wettability of lens during lens wearing, resulted in the better comfortable wearing of lens eventually.

Soil-Water Characteristic Curves for Drying and Wetting Processes in Granite-Weathered Soil Based on Variations in Fine Contents (세립분 함량을 고려한 국내 화강풍화토의 건조 및 습윤 함수특성곡선 분석)

  • Lee, Sangbeen;Ryou, Jae-Eun;Seo, Jinuk;Jung, Jongwon
    • Journal of the Korean Geotechnical Society
    • /
    • v.40 no.1
    • /
    • pp.47-54
    • /
    • 2024
  • In current slope stability analysis techniques, slope stability is evaluated based on the saturated-soil theory. However, soil-water characteristics change frequently depending on the climate. Therefore, because the saturated soil theory has limitations, the application of the unsaturated soil theory is necessary for slope stability. It is also important to evaluate the engineering properties of unsaturated soil because the capillary absorption capacity is reduced due to heavy rain, thereby causing a reduction in slope stability. In this study, soil-water characteristic tests were performed using four samples with different fine contents (0%, 10%, 20%, and 30%) using granite-weathered soil in domestic production areas. In particular, to consider the previously conducted drying process as well as the evaluation of stability due to heavy rain on the actual slope, a wetting process was conducted, in which the water content was increased. In addition, the van Genuchten (1980) model, which is the most consistent theoretical equation for the experiment, was used with various theoretical equations, and the parameters were analyzed according to the fine content of the granite-weathered soil for the drying and wetting processes.

Influencing Factors on Cleaning Ability in the Formulated Hydrocarbon-based Cleaning Agents (탄화수소계 배합세정제에서의 세정성 영향인자 연구)

  • Jung, Young-Woo;Lee, Ho-Yeoul;Bae, Jae-Heum
    • Clean Technology
    • /
    • v.13 no.2
    • /
    • pp.143-150
    • /
    • 2007
  • The objective of this study is to develop hydrocarbon-based cleaning agents by blending paraffins, glycol ethers and siloxanes in oder to effectively clean contaminants such as flux, solder and grease. And the effect of cleaning ability by wetting index, aniline points and solubility parameter of the formulated hydrocarbon-based cleaning agents were studied in this work. The formulated hydrocarbon-based cleaning agents were prepared on the base of physical properties of their individual components. Wetting indexes and aniline points of their were measured through experiments and solubility parameters of their were calculated based on the Hansen's equation. In this study, evaluation of cleaning ability by cleaning agents were carried out using contaminants such as flux, solder, and grease. The experimental results showed that the cleaning ability of the formulated cleaning agents was excellent in cleaning contaminants such as flux, solder and grease and that the influencing parameters on their cleaning efficiency were found to be different according to contaminant types. MC($20.3MPa^{1/2}$), DF-1 ($24.2MPa^{1/2}$) and DF-2($21.5MPa^{1/2}$) with similar solubility parameter as flux ($21.3MPa^{1/2}$) showed 100% cleaning efficiency within 3 minutes in flux cleaning. And CFC-113, MC and 1,1,1-TCE with low aniline point less than $-20^{\circ}C$ showed excellent cleaning efficiency in solder cleaning. DG-1($16.2\;MPa^{1/2}$) and DG-2($15.5\;MPa^{1/2}$) with similar solubility parameter as grease($15.0{\sim}17.0\;MPa^{1/2}$) showed relatively low cleaning efficiency of grease, but CFC-113 and MC with high wetting index and low aniline point showed good cleaning efficiency in grease cleaning. As a result of this study, the hydrocarbon-based cleaning agents alternative to regulated cleaning agents such as CFC-113, 1,1,1-TCE and MC were able to be developed through properly blending paraffins, glycol ethers and siloxanes for cleaning flux, solder and grease. And it can be shown that various influencing parameters of cleaning efficiency such as wetting index, aniline point, solubility parameter and etc. of the non-aqueous cleaning agent should be reviewed for prediction of their cleaning ability and can be applied to formulation of cleaning agents.

  • PDF

Influence of SiC on Thermal Stabilities and Mechanical Interfacial Properties of Carbon Fibers-reinforced Composites (탄화규소의 첨가가 탄소섬유 강화 복합재료의 열안정성 및 기계적 계면특성에 미치는 영향)

  • Oh Jin-Seok;Park Soo-Jin;Lee Jae-Rock;Kim Yeung-Keun
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.04a
    • /
    • pp.182-185
    • /
    • 2004
  • In this work, the effect of chemical treatments on surface properties of SiC was investigated in mechanical interfacial properties of carbon fibers-reinforced composites. The surface properties of the SiC were determined by acid/base values and contact angles. The thermal stabilities of carbon fibers-reinforced composites were investigated by thermogravimetric analysis (TGA). Also, the mechanical interfacial properties of the composites were studied in interlaminar shear strength (ILSS) and critical strain energy release rate mode II $(G_{IIC})$ measurements. As a result, tile acidically treated SiC (A-SiC) had higher acid value than that of untreated SiC (V-SiC) or basically treated SiC (B-SiC). According to the contact angle measurements, it was observed that chemical treatments led to an increase of surface free energy of the SiC surfaces, mainly due to the increase of the specific (polar) component. The mechanical interfacial properties of the composites, including ILSS and $(G_{IIC})$, had been improved in the specimens treated by chemical solutions. These results were explained that good wetting played an important role in improving the degree of adhesion at interfaces between SiC and epoxy resin matrix.

  • PDF

Nanotribological Properties of Hydrophobic Surfaces Using an Atomic Force Microscope

  • Yoon, Eui-Sung;Yang, Seung-Ho;Oh, Hyun-Jin;Han, Hung-Gu;Kong, Ho-Sung;Lee, Hae-Seong
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.55-56
    • /
    • 2002
  • Nanotribological characteristics of hydrophobic surfaces were studied experimentally using an atomic force microscope (AFM). Two kinds of thiolic self-assembled monolayers (SAM) having different spacer chains and their mixture were deposited onto gold-coated mica, where the deposited SAM resulted in the hydrophobic nature. Results showed that the mixed thiolic SAMs resulted in low adhesion and friction in nano-scale contact. It was argued that the water wetting characteristics played a central role on nano-scale adhesion and friction. Also the effect of mixing the thiolic SAMs were discussed on the basis of real area on contact and the stiffness of the SAM layers.

  • PDF

Relations Between Dispersion of CNTs and Electrical Conductivity in the Hydrophobic CNT/PVDF Composite Film (소수성 CNT/PVDF 복합막에서 CNT의 분산과 전도성의 관계)

  • Lee, Sunwoo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.7
    • /
    • pp.462-466
    • /
    • 2015
  • In this paper, we investigated the relations between dispersion of CNTs (carbon nanotubes) and electrical conductivity in the CNT/PVDF (polyvinylidene fluoride) composite film. By adding hydrophobic CNTs as filler into the PVDF matrix, we fabricated hydrophobic and electrically conducting polymer coating film. Dispersion of CNTs in the CNT/PVDF composite film plays a significant role in terms of electrical conductivity and wetting property. Spray coating method was used to form the CNT/PVDF composite films by injecting the dispersed CNTs in the PVDF solution with different weight ratios from 0.7 wt% to 7 wt%. We investigated the electrical properties and contact angles of the CNT/PVDF composite films with the CNT concentration. Finally we discussed the conducting mechanism and feasibility of the CNT/PVDF composite film for the conducting polymer films.