• 제목/요약/키워드: wet gauge

검색결과 18건 처리시간 0.023초

가을철 대기환경 중 수용성 이온성분의 침적특성 (Deposition Characteristics of Water-soluble Inorganic Ions in the Iksan Ambient Air during Fall, 2004)

  • 강공언;김남송;전선복
    • 한국환경보건학회지
    • /
    • 제32권4호
    • /
    • pp.359-372
    • /
    • 2006
  • In order to investigate the daily deposition characteristics of water-soluble inorganic components in airborne deposit on the Iksan, deposition samples were collected using a deposition gauge from October 16 to November 1, 2004. Deposition samples were collected using two different sampling gauges, a dry gauge and a wet gauge, respectively. To get wet the bottom of wet gauge during the sampling period, the volume of $30{\sim}50ml$ distilled ionized water was added in a wet gauge before the beginning of each deposition sampling. Deposition samples were collected twice a day and analyzed for inorganic water-soluble anions ($Cl^-,\;{NO_3}^-,\;{SO_4}^{2-}$) and cations (${NH_4}^+,\;Na^+,\;K^+,\;Mg^{2+},\;Ca^{2+}$) using ion chromatography. Qualify control and quality assurance of analytical data were checked by the data obtained from reinjection of standard solution, Dionex cross check standard solutions, and random several deposition samples, and measured data was estimated to be reliable. Considering the deposition sample volume, the sampling time, the surface area of sampling container, and the ion concentration measured, the daily deposition amounts for measured ions were calculated in $mg/m^2$. The total daily deposition amounts of all measured ions for dry and wet gauge were $7.5{\pm}2.8$ and $17.7{\pm}4.2mg/m^2$, respectively. A significant increase in deposition amount during rainfall days was observed for both wet gauge and dry gauge, having no difference of deposition amount between in wet gauge and in dry gauge. The mean deposition of all ions measured in this study were higher in wet gauge than in dry gauge because of the surface difference of the sampling container, especially for ${NH_4}^+\;and\;{SO_4}^{2-}$. The mean deposition amounts of ${NH_4}^+\;and\;{SO_4}^{2-}$ in wet gauge were found to be about 10 times and 3 times higher than those in dry gauge, while the rest of the chemical species were equal or a little higher in wet gauge than in dry gauge. Dominant species in dry gauge were ${NO_3}^-\;and\;Ca^{2+}$, accounting for 21% and 28% of the total ion deposition, whereas those in wet gauge were ${SO_4}^{2-}\;and\;{NH_4}^+$, accounting for 19% and 41% of the total ion deposition, respectively.

익산지역 대기에어로졸 중 수용성 이온성분의 계절별 침적 특성 (Seasonal Deposition Characteristics of Water-soluble Ion Species in Ambient Aerosol in Iksan City)

  • 강공언
    • 한국환경보건학회지
    • /
    • 제39권1호
    • /
    • pp.56-70
    • /
    • 2013
  • Objectives: This paper aims to investigate the seasonal deposition characteristics of water-soluble ion species by comparing the deposition amount of two samples taken according to different sampling methods of deposition for ambient aerosol such as gases and particulate matters. Methods: Deposition samples were collected using two deposition gauges in the downtown area of Iksan City over approximately two weeks of each season in 2004. The type of deposition gauges consisted of two different sampling methods known as dry gauge and a wet gauge. The dry gauge was empty and used a dry PE bottle with an inlet diameter of 9.6 cm. Before the beginning of each deposition sampling, a volume of 30-50 ml distilled ionized water was added to the wet gauge to wet the bottom during the sampling period. Deposition samples were measured twice per day and analyzed for inorganic water-soluble ion species using ion chromatography. Results: The daily deposition amounts of all measured ions in the dry gauge and the wet gauge showed a significant increase when precipitation occurred, having no difference of deposition amount between in the wet gauge and in the dry gauge. By excluding two samples from rainy days during the sampling period, the mean daily deposition of all ions in dry gauge and wet gauge were $6.58mg/m^2/day$ and $18.16mg/m^2/day$, respectively. The mean deposition amounts of each ion species were higher in the wet gauge than in the dry gauge because of the surface difference of the sampling gauge, especially for $NH_4{^+}$ and ${SO_4}^{2-}$. The mean deposition amounts of $NH_4{^+}$ and ${SO_4}^{2-}$ in the wet gauge were found to be about 15.4 times and 5.2 times higher than that in dry gauge, with a pronounced difference between spring and summer, while the remaining ion species were 1.1-2.0 times higher in the wet gauge than in the dry gauge. Dominant species in the dry gauge were $Ca^{2+}$ and $NO_3{^-}$, accounting for 36.4% and 18.1% of the total ion deposition, whereas those in the wet gauge were $NH_4{^+}$ and ${SO_4}^{2-}$, accounting for 32.5% and 25.0% of the total ion deposition, respectively. Conclusion: The seasonal differences in deposition amounts of water-soluble ion species in ambient aerosol depending on the two types of different sampling methods were identified. This suggests that the removal of ambient aerosol is strongly influenced by the weather conditions of each season as well as the condition of earth's surface, such as dry ground and water.

리스크 완화를 위한 Wet Scrubber 세정수 pH의 효율적 관리 (Efficient Management of the pH of the Wet Scrubber Washing Water for Risk Mitigation)

  • 주동연;서재민;김명철;백종배
    • 한국안전학회지
    • /
    • 제35권6호
    • /
    • pp.85-92
    • /
    • 2020
  • Wet Scrubber reacts the incoming pollutant gas with cleaning water (water + absorbent) to absorb pollutants and release the clean air to the atmosphere. Wet scrubbers and packed tower scrubbers using this principle are widely used in businesses that emit acid gases. In particular, in the etching process using hydrochloric acid (HCl), alkaline washing water (NaOH) having a pH of about 8 to 11 is used to absorb a large amount of acid gas. However, These salts are attached to the injection nozzle (nozzle), filling material (packing), and the demister (Demister), causing air pollution, human damage, and inoperability due to clogging and acid gas discharge. Therefore, In this study, an improvement plan was proposed to manage the washing water with pH 3~4 acidic washing water. The test method takes samples from the Wet Scrubber flue measurement laboratory twice a month for 1 year. Hydrogen chloride (HCl) concentration (ppm) was measured, and nozzle clogging and scale conditions were measured, compared, and analyzed through a differential pressure gauge and a pressure gauge. As a result of the check, it was visually confirmed that the scale was reduced to 50% or less in the spray nozzle, filler, and demister. In addition, the emission limit of hydrogen chloride in accordance with the Enforcement Regulation of the Air Quality Conservation Act [Annex 8] met 3 ppm or less. Therefore, even if the washing water is operated in an acidic pH range of 3 to 4, it is expected to reduce air pollution and human damage due to clogging of internal parts, and it is expected to reduce maintenance costs such as regular cleaning or replacement of parts.

건식 및 수분조건에 따른 차륜/레일의 마모특성 평가 (Wear Characteristics of Wheel/Rail Material under Dry and Wet Conditions)

  • 서정원;권석진;전현규;이동형
    • 한국정밀공학회지
    • /
    • 제33권7호
    • /
    • pp.541-549
    • /
    • 2016
  • Rolling contact fatigue and wear on rails are inevitable in railway operations due to excessive wheel-rail contact stress. The wear is influenced by vehicle speed, contact pressure, environmental conditions, and many other factors. Speeding on a curved track causes many problems such as wear on the gauge of the rail and rolling contact fatigue. Managing environmental conditions can reduce problems on the wheel and rail interface. In this study, the wear characteristics of wheel and rail materials were investigated by twin-disc testing using various parameters. The results of the wear test indicated that the wear rate under dry conditions was larger than that under wet conditions. We found that contact fatigue damage occurred on the rail in dry conditions, however, the surface of the specimen under water remained smooth. Also, the friction coefficient in dry conditions was larger than in wet conditions.

Revisiting the Z-R Relationship Using Long-term Radar Reflectivity over the Entire South Korea Region in a Bayesian Perspective

  • Kim, Tae-Jeong;Kim, Jin-Guk;Kim, Ho Jun;Kwon, Hyun-Han
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2021년도 학술발표회
    • /
    • pp.275-275
    • /
    • 2021
  • A fixed Z-R relationship approach, such as the Marshall-Palmer relationship, for an entire year and for different seasons can be problematic in cases where the relationship varies spatially and temporally throughout a region. From this perspective, this study explores the use of long-term radar reflectivity for South Korea to obtain a nationwide calibrated Z-R relationship and the associated uncertainties within a Bayesian regression framework. This study also investigates seasonal differences in the Z-R relationship and their roles in reducing systematic error. Distinct differences in the Z-R parameters in space are identified, and more importantly, an inverse relationship between the parameters is clearly identified with distinct regimes based on the seasons. A spatially structured pattern in the parameters exists, particularly parameter α for the wet season and parameter β for the dry season. A pronounced region of high values during the wet and dry seasons may be partially associated with storm movements in that season. Finally, the radar rainfall estimates through the calibrated Z-R relationship are compared with the existing Z-R relationships for estimating stratiform rainfall and convective rainfall. Overall, the radar rainfall fields based on the proposed modeling procedure are similar to the observed rainfall fields, whereas the radar rainfall fields obtained from the existing Marshall-Palmer Z-R relationship show a systematic underestimation. The obtained Z-R relationships are validated by testing the predictions on unseen radar-gauge pairs in the year 2018, in the context of cross-validation. The cross-validation results are largely similar to those in the calibration process, suggesting that the derived Z-R relationships fit the radar-gauge pairs reasonably well.

  • PDF

산성 강하물질의 화학적 성분에 관한 연구 (A Study on the Chemical Components of Acid Deposition)

  • 권오영;윤오섭
    • 한국환경보건학회지
    • /
    • 제20권2호
    • /
    • pp.39-54
    • /
    • 1994
  • Dry and wet deposition samples were continuously collected by deposit gauge. In Bulkwang area of Seoul and Kanghwa in west coastal area of Korea. In order to evaluate the level of air pollution and its chemical composition, Bulkwang area located in Seoul and Kanghwa in west coastal area were chosen for sampling site. dry deposition concentrations, pH, electric conductivity and water soluble ion concentrations of deposit gauge were analysed. The results of comparison between urban area and coastal area were summarized as follows. Mean concentrations of dry deposition in Bulkwang was 2.807 ton/km$^2$/month (range: 5.171~1.128 ton/km$^2$/month) while that in Kanghwa was 1.990 ton/km$^2$/month (range: 3.358 ~ 1.084 ton/km$^2$/month), which showed a significant difference between two areas. The rainfall during the period from June to September in 1990 recorded 1859.7 mm which was 78.8% of its mean amount in Seoul, and 1846.9 mm which was 81.6% that of Kanghwa. In Bulkwang area, correlation coefficients of deposit chemical composition were 0.95 for SO$_4^{-2}$ and Na$^+$, 0.94 for SO$_4^{-2}$ and NH$_4^+$, 0.93 for CI$^-$ and NH$_4^+$ and 0.85 for Cl$^-$ and Ca$^{2+}$, respectively. Then, the results indicate that sulfates such as $Na_2SO_4$, $(NH_4)_2SO_4$, and CaSO$_4$ were the major chemical state of deposit. In Kanghwa area, it was considered that NaCl, $NH_4NO_3$, NaNO$_3$, and $Ca(NO_3)_2$ were the major chemical state of deposit.

  • PDF

세탁과 건조에 따른 양모 위편성물의 편성조직별 형태 변화 (The effects of knit stitches on the knit construction and the dimensional stability to washing and drying of wool weft-knitted fabrics)

  • 박세은;백성필;박명자
    • 한국의상디자인학회지
    • /
    • 제24권2호
    • /
    • pp.1-10
    • /
    • 2022
  • The purpose of this study is to analyze the structural properties of 100% wool fabrics knitted with various stitch types and to evaluate dimensional stability from shrinkage in wet cleaning and drying. Materials were weft-knitted from twenty-four different stitches with 7 gauge using a computerized flatbed knitting machine. Weight, thickness, density, and length were measured. A domestic washing machine and a tumble dryer were used for the shrinkage test. The results are as follows: Knitted fabrics were divided into 3 groups based on weight per unit area. Porous knits show light weight whilst milano, pintuck, rib stitches belong to the heaviest group. A positive correlation between weight and thickness was found and the same result was obtained for wale density and weight. Dimensional shrinkage of knitted fabrics was increased during repetitive wet cleaning and drying regardless of knit stitches. Especially, fabrics knitted with float, tuck, cable, and links & links stitches samples were contracted more than 15% in the first treatment whereas 2x1 rib stitch showed 1% shrinkage rate. Fisherman and milano stitches contracted in both course and wale direction with similar shrinkage rates. However, porous knits with float and tuck stitches shrank in course direction by 20% as well as cable samples contracted from 5% to 20% after repeated washing and drying. On the other hand, 30% and 15% contraction of wale direction occurred in orderly float and links & links stitches, respectively. Machine dried knits have a higher shrinkage rate than air-dried knits, but the drying method did not affect to the direction of contraction. In conclusion, variations of knit, tuck, and float stitches affect knit construction and dimensional stability from shrinkage in wet cleaning and drying of wool knitted fabrics.

금강유역에서의 지하수위와 강수량 이동평균의 상관관계 분석 (The Analysis of the Correlation between Groundwater Level and the Moving Average of Precipitation in Kum River Watershed)

  • 양정석;안태연
    • 지질공학
    • /
    • 제18권1호
    • /
    • pp.1-6
    • /
    • 2008
  • 금강유역의 관측소로부터 수집된 강우자료와 지하수위자료를 분석하고 두 자료를 비교 분석하였다. 그리고 강우사상이 지하수위에 미치는 영향분석을 추계학적 기법인 이동평균법을 사용하여 지하수위와 강우이동평균값의 상관관계를 분석하였다. 지하수위는 강우의 계절적 분포를 대체로 따르며 대체로 12월 초부터 4월 말까지 낮은 지하수위를 형성한다. 7월과 8월의 풍수기에는 상대적으로 높은 지하수위를 형성한다. 선행강우를 고려하기 위한 강우이동평균값과 지하수위의 상관관계는 자료의 길이가 최소 2년 이상인 지하수위 관측소를 먼저 선정하였다. 강우와 지하수위 관측소 pair를 선정함에 있어 강우의 비균질한 분포를 고려해서 지하수위 관측소보다 상류에 인접한 강우관측소를 선정하여 두 자료를 분석하였다. 금강유역의 여러 관측소 자료를 분석한 결과 이동평균기간이 10일에서 150일 범위의 값을 가질 때 최대상관계수를 가졌다. 상관계수값은 자료의 질이나 결측기간 또는 융설이나 다른 요인에 의해 넓은 범위의 값을 가지는데 금강유역의 경우 최대 0.8886의 값을 가진다.

소나무 연륜연대기를 이용한 영동지방의 5~6월 강수량 (253년간: A.D. 1746~1998) 복원 (Reconstruction of May~June Precipitation (253 Years: A.D. 1746~1998) in East-Coastal Region (Yungdong) of Korea from Tree Rings of Pinus densiflora S. et Z.)

  • 박원규;서정욱
    • 한국제4기학회지
    • /
    • 제14권2호
    • /
    • pp.87-99
    • /
    • 2000
  • 설악산에서 작성된 8개 지역 연륜연대기 중 강수량 복원에 적합한 대승폭포 인근 2개 지역(해발고 700~900m)의 연륜연대기를 이용하여 253년간 (A.D. 1746~A.D. 1998)의 5월~6월 총강수량을 복원하였다. 1765~1800년(최장 가뭄), 1835~1845년, 1890~1910년, 1920~1940년, 1980~1995년이 건조기로 나타났으며, 1810~1830년, 1860~1890년, 1950~1970년이 습윤한 시기로 나타났다. 장기간으로 보았을 때, 18세기 후반기는 건조한 기간이었으며, 19세기의 5월~6월 총강수량이 250mm로 20세기의 231mm보다 많아 19세기가 20세기보다 상대적으로 습윤하였음을 알 수 있었다. 강수량 변화폭이 19세기가 20세기보다 큰 것으로 관찰되었다. 전 기간에 걸친 주요한 건습 주기는 단기간은 3년, 장기간은 60~80년으로 조사되었다. 서울지방의 측우기 자료와는 1800년대 초를 제외하곤 대체로 일치하였다.

  • PDF

실리콘 직접 접합을 위한 선형가열법의 개발 및 SOI 기판에의 적용 (Development of Linear Annealing Method for Silicon Direct Bonding and Application to SOI structure)

  • 이진우;강춘식;송오성;양철웅
    • 한국표면공학회지
    • /
    • 제33권2호
    • /
    • pp.101-106
    • /
    • 2000
  • SOI (Silicon-On-Insulator) substrates were fabricated with varying annealing temperature of $25-660^{\circ}C$ by a linear annealing method, which was modified RTA process using a linear shape heat source. The annealing method was applied to Si ∥ $SiO_2$/Si pair pre-contacted at room temperature after wet cleaning process. The bonding strength of SOI substrates was measured by two methods of Razor-blade crack opening and direct tensile test. The fractured surfaces after direct tensile test were also investigated by the optical microscope as well as $\alpha$-STEP gauge. The interface bonding energy was 1140mJ/m$^2$ at the annealing temperature of $430^{\circ}C$. The fracture strength was about 21MPa at the temperature of $430^{\circ}C$. These mechanical properties were not reported with the conventional furnace annealing or rapid thermal annealing method at the temperature below $500^{\circ}C$. Our results imply that the bonded wafer pair could endure CMP (Chemo-Mechanical Polishing) or Lapping process without debonding, fracture or dopant redistribution.

  • PDF