• Title/Summary/Keyword: wet blue

Search Result 58, Processing Time 0.023 seconds

Persulfate Wet Oxidation Method for the Determination of Total Phosphorus in Atmospheric Aerosols and Its Application for a Year-round Observation in Beijing

  • Okuda, Tomoaki;Gunji, Yuma;He, Kebin;Ma, Yongliang
    • Asian Journal of Atmospheric Environment
    • /
    • v.7 no.3
    • /
    • pp.169-175
    • /
    • 2013
  • Measurement of the phosphorus concentration in aerosols in Beijing, which was a representative East Asian mega-city, was carried out. The optimum procedure for analyzing phosphorus in aerosols was found in this study. Recovery of phosphorus in environmental samples through the improved method was almost 100%. The concentration of phosphorus in TSP was $145{\pm}47\;ng/m^3$, with a seasonal variation showing high concentrations in winter and low concentrations in summer. The concentrations of phosphorus in $PM_{2.5}$ accounted for $35{\pm}6%$ of those in TSP, with no seasonal variations. The major source of phosphorus in aerosols in Beijing was soil dust, and additional sources of phosphorus in fine particles could be coal combustion and biomass burning.

Defects Evaluation of Blue Light Emitting Materials by Wet Etching and Transmission Electron Microscoppy

  • Hong, Soon-Ku;Kim, Bong-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.105-106
    • /
    • 1998
  • Evaluation of def3ects by etch-ppit formation was studied. A NaOH(30 mol%) etchant was found useful for etch-ppit developpment on ZnSe-based eppilayers grown on (001) gaAs. And a H3ppO4(85 mol%) was used in order to developp etch-ppits on GaN-base eppilayers grown on (0001) Al2O3 After etch-ppit formation on the surfsce. Transmission Electron Microscoppy(TEM) was cppmdicted. By etch-ppit developpment and TEM observation we could determine the defect typpes by etch-ppit configurfations and found origin of etch-ppit in the cse of ZnSe-based materials. Based uppon these results we can do defect identification by etch-ppit test simpply. In the case of GaN-based materials we could evaluate nanoppippe density. however high density of threading dislocations in GaN eppilayers were not revealed by etch-ppit developpment. Based uppon these results we can evaluate the nanoppippe density which difficult to evaluate using TEM beacause of its small size(diameter). And at ppresent status direct matching of etch-ppit density to dislocation density would make severe mistake.

  • PDF

A New Door for Molecular-Based Organic Electroluminescent Devices

  • Jou, Jwo-Huei;Wang, Wei-Ben;Hsu, Mao-Feng;Lai, Wen-Hsuan;Chen, Chin-Ti;Chin, Chih-Lung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.350-353
    • /
    • 2009
  • While the comparatively high MW would make the employed molecules extremely difficult to vacuum-evaporate, and result in poor device performance, the wet-process has been proven to be quite effective and convenient as usual to the fabrication of high-efficiency OLEDs composing high MW components.

  • PDF

Affinity Separations Using Microfabricated Microfluidic Devices: In Situ Photopolymerization and Use in Protein Separations

  • Chen Li;Lee, Wen-Chien;Lee, Kelvin H.
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.8 no.4
    • /
    • pp.240-245
    • /
    • 2003
  • The use of microfabricated microfluidic devices offers significant advantages over current technologies including fast analysis time and small reagent requirements. In the context of proteomic research, the possibility of using affinity-based separations for prefractionation of samples using microfluidic devices has significant potential. We demonstrate the use of microscale devices to achieve affinity separations of proteins using a device fabricated from borosilicate glass wafers. Photolithography and wet etching are used to pattern individual glass wafers and the wafers are fusion bonded at 650$^{\circ}C$ to obtain enclosed channels. A polymer has been successfully polymerized in situ and used either as a frit for packing beads or, when derivatized with Cibacron Blue 3GA, as a separation matrix. Both of these technologies are based on in situ UV photopolymerization of glycidyl methacrylate (GMA) and trimethylolpropane trimethacrylate (TRIM) in channels.

Prevalence and Comparison of Diagnostic Methods for Trichomonas vaginalis Infection in Pregnant Women in Argentina

  • Perazzi, Beatriz E.;Menghi, Claudia I.;Coppolillo, Enrique F.;Gatta, Claudia;Eliseth, Martha Cora;De Torres, Ramon A.;Vay, Carlos A.;Famiglietti, Angela M. R.
    • Parasites, Hosts and Diseases
    • /
    • v.48 no.1
    • /
    • pp.61-65
    • /
    • 2010
  • The objectives of this study were to conduct a prevalence survey of trichomoniasis in pregnant women and to evaluate the utility of different methods for its diagnosis. A total of 597 vaginal exudates from pregnant women who were examined at the Hospital de Clinicas in Buenos Aires, Argentina from 1 August 2005 to 31 January 2007, were prospectively and consecutively evaluated. The investigation of Trichomonas vaginalis was made by different microscopic examinations, and culture on liquid medium. The sensitivity and specificity of the microscopic examinations were assessed considering culture on liquid medium as the "gold standard". The prevalence of T. vaginalis obtained by culture on liquid medium was 4.0% (24/597). The prevalence of T. vaginalis obtained by direct wet smear, prolonged May-Grunwald Giemsa staining, and sodium acetate-formalin (SAF)/methylene blue staining-fixing technique was 1.8%, 2.3% and 2.5%, respectively. The sensitivity of the direct wet smear was 45.8%, that of the prolonged May-Grunwald Giemsa staining was 58.3%, and that of the SAF/methylene blue method was 62.5%. Considering the 3 microscopic examinations altogether, the sensitivity rose to 66.7% and the specificity was 100% for all of them. This is the first time that the prevalence data of T. vaginalis by culture in pregnant women are published in Argentina. Due to the low sensitivity obtained by microscopy in asymptomatic pregnant women, the use of the liquid medium is recommended during pregnancy, in order to provide an early diagnosis and treatment.

Antiulcerative Effect of Sikhe on Stomach Ulcer Induced by Ethanol (식혜의 에탄올 유발 위궤양에 대한 예방 효과)

  • 박은지;김현정;김중만;전향숙
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.26 no.1
    • /
    • pp.98-102
    • /
    • 1997
  • The antiulcerative effect of Sikhe(Korean traditional sweet rice drink) on stomach ulcer induced by ethanol treatment was investigated. Fifty male mice were divided into 5 groups consisting of control group and 4 Sikhe groups fed 0.3% commercial Sikhe(group I), 3% commercial Sikhe(group II), 0.3% home-made Sikhe(group III) and 3% home-made Sikhe(group IV). Mice were fed experimental diet ad libitum for 45 days. Growth, stomach surface pH, gastric wall mucosa and ulcer index were examined. Feed intake and weight gain did not show significant differences among 5 groups(p>0.05). The stomach surface pH and the amount of gastric wall mucosa of Sikhe fed groups(group I~IV) were higher than those of the control group, but were not significantly different(p>0.05) . The ulcer indices of the control and Sikhe fed groups were 18.6$\pm$6.58mm and 13.7$\pm$5.87~17.8$\pm$9.10, respectively. But significant differences were not found between the control and the Sikhe fed groups(p>0.05) though mean values of Sikhe fed groups were lower than that of the control group.

  • PDF

The Evaluation of the atomic composition and the surface roughness of Titanium Implants following Various Laser treatment with air-powder abrasive (레이저 처리후 임프란트 표면 변화에 관한 연구)

  • Kim, Tae-Jung;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.3
    • /
    • pp.615-630
    • /
    • 2002
  • Various long-term studies have shown that titanium implants as abutments for different types of prostheses have become a predictable adjunct in the treatment of partially or fully edentulous patients. The continuous exposure of dental implants to the oral cavity with all its possible contaminants creates a problem. A lack of attachment, together with or caused by bacterial insult, may lead to peri-implantitis and eventual implant failure. Removal of plaque and calculus deposits from dental titanium implants with procedures and instruments originally made for cleaning natural teeth or roots may cause major alterations of the delicate titanium oxide layer. Therefore, the ultimate goal of a cleaning procedure should be to remove the contaminants and restore the elemental composition of the surface oxide without changing the surface topography and harming the surrounding tissues. Among many chemical and mechanical procedure, air-powder abrasive have been known to be most effective for cleaning and detoxification of implant surface. Most of published studies show that the dental laser may be useful in the treatment of pen-implantitis. $CO_2$ laser and Soft Diode laser were reported to kill bacteria of implant surface. The purpose of this study was to obtain clinical guide by application these laser to implant surface by means of Non-contact Surface profilometer and X-ray photoelectron spectroscopy(XPS) with respect to surface roughness and atomic composition. Experimental rough pure titanium cylinder models were fabricated. All of them was air-powder abraded for 1 minute and they were named control group. And then, the $CO_2$ laser treatment under dry, hydrogen peroxide and wet condition or the Soft Diode laser treatment under Toluidine blue O solution condition was performed on the each of the control models. The results were as follows: 1. Mean Surface roughness(Ra) of all experimental group was decreased than that of control group. But it wasn't statistically significant. 2. XPS analysis showed that in the all experimental group, titanium level were decreased, when compared with control group. 3. XPS analysis showed that the level of oxygen in the experimental group 1, 3($CO_2$ laser treatment under dry and wet condition) and 4(Soft Diode laser was used under toluidine blue O solution) were decreased, when compared with control group. 4. XPS analysis showed that the atomic composition of experimental group 2($CO_2$ laser treatment under hydrogen peroxide) was to be closest to that of control group than the other experimental group. From the result of this study, this may be concluded. Following air-powder abrasive treatment, the $CO_2$ laser in safe d-pulse mode and the Soft Diode laser used with photosensitizer would not change rough titanium surface roughness. Especially, $CO_2$ laser treatment under hydrogen peroxide gave the best results from elemental points of view, and can be used safely to treat peri-implantitis.

Physicochemical Properties of Various Milled Rice Flours (제분방법별 쌀가루의 이화학적 특성)

  • Park, Yong-Kon;Seog, Ho-Moon;Nam, Young-Jung;Shin, Dong-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.504-510
    • /
    • 1988
  • The physicochemical properties of rice flours which were obtained by dry milling(blade, hammer, test and micro mill) and wet & dry milling (roller & micro mill) were investigated. The resulting flour particle sizes were reduced in the order that of blade, hammer, test, micro and roller & micro mill. Scanning electron microscopic examination showed that the starch granules were freed from the imbedding matrix as the particles became finer. The test-milled flour had the hightest levels of starch damage, maltose value and hot-water soluble amylose content, and the blade-milled flour showed the lowest levels. Amylograph viscosity and gelatinization temperature of the flours decreased as the particles became finer, and the addition of $Hg^{+2}$ increased the peak viscosity of the dry-milled flour pastes, whereas the wet & dry-milled flour did not show any changes. The blue values and ${\lambda}$max values of the iodine complex of the cold-water extractable ${\alpha}-D-glucan$ from flours were in the range of 0.023-0.029 and 518-522nm, respectively, indicating these materials were shown to be mainly composed of amylopectin-like polymer.

  • PDF

The SEM and SPM Study on the Change of Machined Titanium Implant Surface following Various Laser Treatments (수종의 레이저로 임프란트 표면 처리 시 표면 형태의 변화에 대한 주사전자 및 주사탐침 현미경적 연구)

  • Kim, In-Kyung;Chung, Chin-Hyung;Lim, Sung-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.2
    • /
    • pp.451-463
    • /
    • 2001
  • Following the extensive use of implant, the incidence of peri-implantitis increases. Guided bone regeneration has been used for the optimal treatment of this disease. Because implant surface was contaminated with plaque and calculus, cleaning and detoxification were needed for the reosseointegration when guided bone regeneration was performed. Various mechanical and chemical methods have been used for cleaning and detoxification of implant surface, air-powder abrasive and oversaturated citrate were known to be most effective among these methods. However, these methods were incomplete because these could not thoroughly remove bacteria of implant surface, moreover deformed implant surface. Recent studies for detoxification of the implant surface using laser were going on, $CO_2$ laser and Soft Diode laser were known to be effective among these methods. The purpose of this study was to obtain clinical guide by application these laser to implant surface. 15 experimental machined pure titanium cylinder models were fabricated. The $CO_2$ laser treatment under dry, wet and hydrogen peroxide condition or the Soft Diode laser treatment under Toluidine blue O solution condition was performed on the each of models. Each groups were examined with SPM and SEM to know whether their surface was changed. The results were as follows : 1. Surface roughness and surface form weren't changed when $CO_2$ laser was usedunder dry condition(P>0.05). 2. Surface roughness and surface form weren't changed when $CO_2$ laser was used under wet condition(P>0.05). 3. Surface roughness and surface form weren't changed when $CO_2$ laser was used under hydrogen peroxide condition(P>0.05). 4. Surface roughness and surface form weren't changed when Soft Diode laser was used under toluidine blue O solution condition(P>0.05). From the result of this study, it may be concluded that the $CO_2$ laser having relatively safe pulse mode and the Soft Diode laser used with photosensitizer can be used safely to treat peri-implantitis.

  • PDF

Effect of Tannin Mordanting on Gromwell-dyed Silk Fabric (견직물의 자초 염색 시 합성탄닌의 매염 효과)

  • Park, Ah-Young;Song, Wha-Soon;Kim, In-Young
    • Textile Coloration and Finishing
    • /
    • v.20 no.6
    • /
    • pp.51-62
    • /
    • 2008
  • The purpose of this study was to check color change depending on dyeing conditions when silk fabrics was dyed with gromwell and to investigate mordant effect when synthetic tannin was used as a mordant. First, when silk fabrics were dyed with gromwell, the change of color, brightness and chroma were examined by measuring K/S value, a, b value, L value and C value depending on dyeing condition. Second, color, brightness and chroma differences which appeared after mordanting with synthetic tannin were investigated and muti-functional mordanting effect was confirmed with dyeing fastness, antibiosis. As a result of color analysis of gromwell, it was proved that the main pigment of gromwell was shikonin. Color was red purple at pH 3 when silk fabrics were dyed with gromwell. But It became greenish and bluish as temperature rose and time passed by. And it grew reddish and yellowish as concentration level reached higher. The color became purple at pH 5 and purple blue at pH 7. Both at pH 5 and pH 7, it became greenish and yellowish, as temperature went up and time ran by. And it became reddish with concentration increasing. Brightness and chroma decreased with temperature and concentration increasing as well as time passing by. After mordanting with synthetic tannin, the color became less reddish at pH 3 and reddish-yellowish at pH 5 and pH 7. The brightness increased and the chroma decreased. At all pH, the color, the brightness and the chroma became similarly by synthetic tannin mordanting. Dyeing fastness of synthetic tannin mordanted fabric was higher than that of non-mordanted fabric. Especially, wet fastness at pH 3 improved from 1 grade before synthetic tannin mordanting to $3{\sim}4$ grade after tannin mordanting. Antibiosis was improved by gromwell dyeing and synthetic tannin mordanting.