• Title/Summary/Keyword: well water quality

Search Result 1,358, Processing Time 0.035 seconds

Pollutants Classification based on Trend Analysis and Assessment of Water Pollutants Achievement in Subbasins of Han River Basin (한강수계 중권역별 오염물질 추세분석 및 달성도 평가를 통한 우선관리물질 선정)

  • Kim, Kyeung;Song, Jung-Hun;Lee, Do Gil;Hwang, Ha-sun;Kang, Moon Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.3
    • /
    • pp.67-76
    • /
    • 2019
  • The objectives of this study were to analyze trends of water pollutants and to evaluate the achievement of water quality standards by subbasins in the Han River. The trends of 40 water pollutants at 232 water quality measurement points were analyzed. Chemical oxygen demand (COD), Total organic carbon (TOC), Total coliforms (TC), et cetera were found to be worsening trend. For evaluation of achievement, we evaluated water quality arithmetic mean with river environment standards and human health standards at representative points of the subbasin. Biochemical oxygen demand (BOD), TOC, Total phosphorus (T-P), Fecal coliforms (FC), TC exceeded water quality standards, and water quality of human health standards was all satisfied. So, we prioritized pollutants. If pollutants exceed water quality standards or were worse, they were classified first pollutants. Although BOD and T-P are first pollutants because of water quality standards excess, they are continuously improved. Also, it is better to maintain current status because water quality management system of BOD and T-P is well prepared. Meanwhile, TOC, TC, and FC exceed water quality standards. Furthermore, they were worse gradually, but there is a lack of management systems such as water quality standards of the effluence facilities. Therefore, it is necessary to supplement the system. The results of this study can be used as primary data for the establishment of water quality standards and selection of management pollutants.

Desalination of Seawater by Reverse Osmosis (역삼투법에 의한 해수의 담수화에 관한 연구)

  • Lee, Sun Ju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.2
    • /
    • pp.155-164
    • /
    • 2004
  • Many countries, including Korea, suffer from a shortage of freshwater. With increases in population and the quality of life, along with large-scale expansion in industrial and agricultural activities, more freshwater is needed. Available resources, Including ground water, are limited, and desalination presents the opportunity for a new unlimited source of freshwater from the sea. The objectives of this study were to test membrane performance in seawater desalination and to examine the quality of water produced. bath well and sea water were used as water sources. Typically used membrane for seawater desalination and high rejection seawater desalination membrane are maintained at almost same recovery rate and permeate flux, while the conductivity was lower in the operation of typically used seawater membrane. The treated water quality using two types of membranes is satisfied with the Korea drinking water quality standards.

Development of a new system for measurement of total effluent load of water quality

  • Keiji, Takase;Akira, Ogura
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.221-221
    • /
    • 2015
  • Sustainable use of water resource and conservation of water quality are essential problems in the world. Especially, problems of water quality are serious one for human health as well as ecological system of all creatures on the earth. Recently, the importance of total effluent load as well as the concentrations of pollutant materials has been recognized not only for the conservation of water quality but also for sustainable water use in watersheds. However, the measurement or estimation of total effluent load from non-point source area such as farm lands or forests may be more difficult because both of concentration and discharge of the water are greatly changed depending on various factors especially metrological conditions such as rainfall, while the measurement from a point source area may be easy because the concentration of pollutant materials and amount of discharge water are relatively steady. Therefore, the total effluent load from a non-point source is often estimated by statistical relationships between concentration and discharge, which is called as L-Q equation. However, a lot of work and time are required to collect and analyze water samples and to get the accurate relationship or regressive equation. So, we proposed a new system for direct measurement of total effluent load of water quality from non-point source areas to solve the problem. In this system, the overflow depth at a hydraulic weir is measured with a pressure gage every hourly interval to calculate the amount of hourly discharge at first. Then, the operating time of a small electric pump to collect an amount of water which is proportional to the discharge is calculated to intake the water into a storage tank. The stored water is taken out a few days later in a case of storm event or several weeks later in a case of non-rainfall event and the concentrations of water quality such as total nitrogen and phosphorous are analyzed in a laboratory. Finally, total load of the water quality can be calculated by multiplying the concentration by the total volume of discharge. The system was installed in a small experimental forestry watershed to check the performance and know the total load of water quality from the forest. It was found that the system to collect a proportional amount of water to actual discharge operated perfectly and a total load of water quality was analyzed accurately. As the result, it was expected that the system will be very available to know the total load from a non-point source area.

  • PDF

Estimation for Raw Water Quality of Manganese Concentrations from Archived Data in Small-scale Water Systems (소규모 정수처리장에서 모니터링 자료를 이용한 원수의 망간농도 예측에 관한 연구)

  • Min, Byung-Dae;Yamazaki Kimiko;Koizumi Akira;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.4
    • /
    • pp.547-554
    • /
    • 2011
  • In small-scale water systems, the measurement of quality of raw water in running water is generally implemented when the quality of water is stable and frequency of measurement is low. However, units such as water temperature and pH, which are easily monitored, are frequently measured. In establishing an improvement plan for a water treatment system, the range of concentration of the target material present in the raw water of the running water provides relevant information. If the concentration of target material can be specified by the quality of water of data items that are measured daily, inverse estimation of the range of concentration is possible as well. In this paper, we took note of manganese in the raw water from Ogasawara-mura, Tokyo, and estimated the manganese concentration in the raw water of the running water for the past five years. Based on the results obtained, we have proposed a manganese removal system, considering the current situation and geographical conditions of Ogasawara-mura.

Speculation on the Water Quality for the Natural Mineral Water (국내 먹는샘물의 특정 수질 항목에 대한 고찰)

  • 조병욱;이병대;이인호;추창오
    • The Journal of Engineering Geology
    • /
    • v.12 no.4
    • /
    • pp.395-404
    • /
    • 2002
  • Contents of the specific components in the natural mineral water was discussed in relation to the well depth and geology. According to water quality data during the last five years(1998~2002), the nitrate and fluoride concentrations, and pH averaged 0.89~ 1.09 mg/L, 0.37~0.45 mg/L, and 7.30~7.59, respectively. These values are the similar range to those of generalized groundwater having same well depths, implying that shallow groundwaters flow into the production wells. In general, no clear relationships between the water quality, well depth, and geology were found. The average arsenic concentration of the natural mineral water increased from 0.0024 mg/L in 1999 to 0.0066 mg/L in 2002. The percentage of production well with arsenic level higher than 0.001 mg/L also increased from 20.1% in 1999 to 64.9% in 2002. In 2002, 11 out of 57 production wells exceed 0.001 mg/L which will be announced as a new arsenic standard for drinking water by USEPA.

Introduction of Water Safety Plan in Korea (물안전계획(Water Safety Plan)의 국내 도입방안)

  • Kim, Jin-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.4
    • /
    • pp.535-545
    • /
    • 2012
  • Recently, drinking water quality has significantly improved with the progress of water treatment technologies, however, customer's trust on tap water is still relatively low. Low trust on water quality is mainly due to vague anxiety. Therefore, to improve customer's trust on drinking water quality new strategy such as water safety plan(WSP) which recommended by WHO and IWA should be introduced. WSP can be defined as an approach which uses comprehensive risk assessment and risk management approach that encompasses all steps in water supply from catchment to consumer to ensure the safety of a drinking water supply. In this study, cases on WSP introduction in other countries as well as strategy for the introduction of WSP in Korea were investigated. In addition, recommendations on the improvement of the current water contamination response manual was suggested based on the analysis of the existing manual at a full scale water treatment plant.

Application of Water-Quality Management Model for Upstream Basin of Hoengsung Dam (횡성댐 상류유역에 대한 수질관리모형의 적용)

  • Kim, Sang Ho;Lee, Eul Rae
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.2
    • /
    • pp.239-246
    • /
    • 2008
  • In this study, an optimized deterministic water-quality model was constructed to estimate water quality of a river and lake in the upstream basin of a dam. A stochastic water-quality analysis using reliability analysis technique was applied to the model. The model was tested in the 13.9 km reach from Maeil stage station of Kyechun to Hoengsung Dam of Sum River. After finding hydraulic characteristics from nonuniform flow analysis, Broyden-Fletcher-Goldfarb-Shanno (BFGS) optimization technique for model calibration was applied to determine optimum reaction parameters, and model verification was performed based on these. The stochastic model, using Mean First­Order Second­-Moment (MFOSM) and Monte-Carlo methods, was applied to the same reach as the deterministic study. Variations of discharge and water quality in headwater were considered, as well as variations of hydraulic coefficients and reaction coefficients. The statistical results of output variables from MFOSM were similar to those from the Monte-Carlo method. Risk analysis using MFOSM and Monte-Carlo methods presented the probabilities of some locations in the Hoengsung Lake violating existing water-quality standards in terms of DO and BOD.

Effect of corrosive water quality control and corrosion index monitoring in pilot scale pipeline simulator (파일럿 규모 모의관로에서 부식성 수질제어 효과와 부식지수 모니터링)

  • Kim, Do-Hwan;Kim, Yung-Jin;Son, Hee-Jong;Ryou, Dong-Choon;Ahn, Jun-Young;Kim, Cheolyong;Hwang, In-Seong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.2
    • /
    • pp.183-192
    • /
    • 2018
  • Applicability of corrosion inhibitor was evaluated using pilot scale water distribution pipe simulator. Calcium hydroxide was used as corrosion inhibitor and the corrosion indices of the water were investigated. Corrosion indices, Langelier saturation index (LI) increased by 0.8 and calcium carbonate precipitation potential (CCPP) increased by 9.8 mg/L. This indicated that corrosivity of water decreased by corrosion inhibitor and the effects lasted for 18 days. Optimum calcium hydroxide dose was found to be 3~5 mg/L for corrosion inhibition. We suggest that monitoring of CCPP as well as LI need to be conducted to control corrosivity of water.

Water Quality Alteration during Passing through Small Water Tank and Improvement of Tap Water Quality by Direct Connection Service (옥상물탱크 경유에 따른 수돗물 수질 변화 및 직결급수방식 도입에 의한 수질개선 효과 연구)

  • Lee, Mok-Young;Chang, Hyun-Jung;Lee, Eu-Kwang;Oh, Se-Jong;Lee, Chae-Keun;Lee, Hyun-Dong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.4
    • /
    • pp.328-336
    • /
    • 2000
  • In order to compare the effect of water quality on two service systems, tank and direct connection service, we selected randomly 30 rooftop tanks installed in the buildings with five or fewer floors, and collected water samples from each tank as well as tap water by direct service. At the same time each tank was investigated on their cleanliness and sanitary control. 30 water samples from direct service met Korean Drinking water quality standard. But 5 tank water samples(17%) were not able to meet Coliform or Total Colony Counts standard and free chlorine of 12 tank water samples(40%) were less than 0.2mg/L. Also Fe, Turbidity, TOC, Total Algae in tank water were higher than tap water on direct service. We concluded that thorough health control of water tank is necessary and conversion into direct connection service results in improving tap water quality importantly.

  • PDF

A Technology for Water Pollution Diffusion Prevention based on Web Map

  • Shin, Jin Seob
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.11
    • /
    • pp.65-71
    • /
    • 2017
  • An integrated water environment management system is necessary in improving water quality, properly allocating water resources, and supporting socio-economic development. Specifically, water quality management system using web map can be an efficient approach to accomplish this system. This paper aims to construct a dynamic water quality management system to reflect a water environment management system which includes three sub-models with consideration of their interrelationships (a socio-economic model based on dynamic Input-Output model, a water resources cycle model, and a water pollutants flow model). Based on simulation, the model can precisely estimate trends of water utilization, water quality, and economic development under certain management targets, and propose an optimal plan. This study utilized the model to analyze the potential of using reclaimed water to accomplish local water environment management and sustainable development plan while exploring the applicable approaches. This study indicates that the constructed water environment management system can be effective and easily adopted to assess water resources and environment while improving the trade-off between economic and environment development, as well as formulate regional development plan.