• Title/Summary/Keyword: well pumping

Search Result 362, Processing Time 0.026 seconds

Iron Extraction Characteristics of Sediment Samples from a River Bank Filtration Site (강변 여과 취수 지역 퇴적물의 철 화학종 추출 특성)

  • Hyun, Sung Pil;Moon, Hee Sun;Yoon, Pilsun;Kim, BoA;Ha, Kyoochul
    • Journal of the Mineralogical Society of Korea
    • /
    • v.26 no.2
    • /
    • pp.129-138
    • /
    • 2013
  • River bank filtration has been considered as a promising alternative water management scheme, in which groundwater is extracted from an aquifer near a river after infiltration of the river water into the aquifer, thereby improving and maintaining the quality of water recovered. Iron (Fe) associated with sediment in contact with groundwater and infiltrating surface water is an important factor in determining the quality of water recovered from the pumping wells in river bank filtration. This study reports the results of Fe speciation in the aquifer sediment samples collected from different depths at the river bank filtration site in Changwon, studied using four different chemical extraction methods, namely, ferrozine, oxalate, HCl, and DCB methods. Overall, the results show that Fe(II) as well as the total Fe content decreases with depth down to ~20 m and then increases further below. This trend is consistent with the redox characteristics suggested by visual observation. The silt/clay size fraction (${\phi}$ < 62.5 ${\mu}M$) has up to 2~10 times more Fe compared with the sand size fraction (62.5 ${\mu}M$ < ${\phi}$ < 2 mm), depending on the extraction method. Of the four extraction methods, DCB solution extracted the most Fe from the sediment samples. The amounts of Fe extracted by the different extraction methods can be a good indicator of the redox conditions along the depth of the aquifer.

Model of Water, Energy and Waste Management for Development of Eco-Innovation Park ; A Case Study of Center for Research of Science and Technology "PUSPIPTEK," South Tangerang City, Indonesia

  • Setiawati, Sri;Alikodra, Hadi;Pramudya, Bambang;Dharmawan, Arya Hadi
    • World Technopolis Review
    • /
    • v.3 no.2
    • /
    • pp.89-96
    • /
    • 2014
  • Center for Research of Science and Technology ("PUSPIPTEK") has 460 hectares land area, still maintained as a green area with more than 30% green space. There are 47 centers for research and testing technology, technology-based industries, and as well as public supporting facilities in PUSPIPTEK area. Based on the concepts developed to make this area as an ecological region, PUSPIPTEK can be seen as a model of eco-innovation. The purpose of this research is to develop a model of water, energy and waste management with eco-innovation concept. As a new approach in addressing environmental degradation and maintaining the sustainability of ecosystem, studies related to eco-innovation policy that combines the management of water, energy and waste in the region has not been done. In order to achieve the objectives of the research, a series of techniques for collecting data on PUSPIPTEK existing conditions will be carried out, which includes utilities data (water, electricity, sewage) and master plan of this area. The savings over the implementation of the concept of eco-innovation in water, energy, and waste management were calculated and analyzed using quatitative methods. The amount of cost savings and feasibility were then calculated. Eco innovation in water management among other innovations include the provision of alternative sources of water, overflow of rain water and water environments utilization, and use of gravity to replace the pumping function. Eco-innovation in energy management innovations include the use of LED and solar cell for air conditioning. Eco-innovation in waste management includes methods of composting for organic waste management. The research results: (1) The savings that can be achieved with the implementation of eco innovation in the water management is Rp. 3,032,640 daily, or Rp.1,106,913,600 annually; (2) The savings derived from the implementation of eco innovation through replacement of central AC to AC LiBr Solar Powered will be saved Rp.1,933,992,990 annually and the use of LED lights in the Public street lighting PUSPIPTEK saved Rp.163,454,433 annually; (3) Application of eco innovation in waste management will be able to raise awareness of the environment by sorting organic, inorganic and plastic waste. Composting and plastic waste obtained from the sale revenue of Rp. 44,016,000 per year; (4) Overall, implementation of the eco-innovation system in PUSPIPTEK area can saves Rp. 3,248,377,023 per year, compared to the existing system; and (5)The savings are obtained with implementation of eco-innovation is considered as income. Analysis of the feasibility of the implementation of eco-innovation in water, energy, and waste management in PUSPIPTEK give NPV at a 15% discount factor in Rp. 3,895,228,761; 23.20% of IRR and 4.48 years of PBP. Thus the model of eco-innovation in the area PUSPIPTEK is feasible to implement.

Hydrologic Characterization through Ground Water Monitoring in a Coastal Aquifer (해안 대수층에서 지하수 장기 모니터링을 통한 수리 특성 조사)

  • Shim, Byoung-Ohan;Lee, Chol-Woo
    • Economic and Environmental Geology
    • /
    • v.44 no.3
    • /
    • pp.239-246
    • /
    • 2011
  • Groundwater in small islands is used as main water resource but the overuse of groundwater may cause seawater intrusion and temperature decrease in geothermal wells. This study aimed to characterize the hydrogeology of Maeum-ri area in Seokmo Island of Ganghwagun using long-term monitoring at groundwater wells and geothermal wells. In the monitoring period seasonal water level change, consistent drop or increase of water levels are not detected. The groundwater temperature about 10m below ground surface shows year cycle variation having two to five months difference with ambient temperature cycle. The storativity was calculated by tidal method. The storativity estimated by adapting tidal efficiency factor showed some larger values than that by using tidal time lag. The result suggested that the tidal method assuming several assumptions on aquifer condition may produce broad ranges but the calculated ranges at this application are reasonable. The similar shape of groundwater level change and tidal effects was observed at several wells clustered east-south-east direction which may implicate the distribution of vertical fracture system strongly related with groundwater flow channels. The applied methodology and study results will bc valuable to evaluate optimal pumping rate for the preservation of groundwater resources, and to manage geothermal development.

Production of ${\beta}-Galactosidase$ with High Transgalactosylation Activity by Bacillus sp. A4442 Mutant (변이주 Bacillus sp. A4442에 의한 갈락토스 전이활성이 높은 ${\beta}-Galactosidase$의 생산)

  • Choi, Kyung-Ho;Yang, Sung-Joon;Kim, Min-Hong;Han, Keum-Soo;Yang, Ji-Won;Jung, Jin;In, Man-Jin
    • Applied Biological Chemistry
    • /
    • v.38 no.6
    • /
    • pp.507-511
    • /
    • 1995
  • In an attempt to improve the productivity of ${\beta}-galactosidase$ from Bacillus sp. A1, which was isolated from soil and has remarkably higher transgalactosylation activity than lactose hydrolysis activity, a chemical mutation procedure using N-methyl-N'-nitro-N-nitrosoguanidine followed by selection was conducted. The final selection, designated as Bacillus sp. A4442, turned out to show a substantially increased enzyme productivity. Catabolite repression by glucose and lactose requirement as an inducer for the enzyme biosynthesis, which were shown in the parent strain, was markedly diminished; instead it was found out that galactose acts as another inducer. Because pH of medium, one of the most important factors for cell growth as well as enzyme production, is closely related with the sugar concentration during culture, it was kept in the optimum range of $6.5{\sim}7.5$; for this the initial glucose concentration was adjusted to be 0.5% which was thereafter maintained by the controlled pumping-in of lactose using the pH-stat technique. By doing so, we were able to increase the productivity of ${\beta}-galactosidase$ with high transgalactosylation activity up to $44\;unit/m{\ell}-broth$.

  • PDF

Change of Soil and Water Temperature on the Different Topography and Irrigation Conditions of Paddy Land (지형(地形)과 관개조건(灌漑條件)에 따른 논의 수온(水溫) 및 지온변화(地溫變化))

  • Kim, Lee Yul;Jo, In Sang
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.22 no.1
    • /
    • pp.12-17
    • /
    • 1989
  • Soil and water temperature were evaluated to relate rice growth to topographical chracteristics in paddy soils. Water temperature (WT) and so il temperature (ST) were measured under the various altitudes, slopes and irrigation methods. Temperature fluctuation and growth status in the same field were measured; 1. Air temperature (AT) and ST of 10cm soil depth were decreased with increasing altitude. Difference of its fluctuation in AT, WT and ST of 10cm soil depth in the lapse rate was 0.64, 0.84 and $0.82^{\circ}C$ per 100m elevation, respectively. 2. Maximum WT, in panicle initiation stage, was decreased slowly with increasing altitude whereas minimum WT fallen rapidly. It suggested that the lapse rate of WT was affected by minimum WT. 3. Source of irrigation water and irrigation method affected the WT. WT, ST and rice growth varied with the locations within the same field. 4. Pumping irrigation of artesian well resulted in more fluctuation of WT between irrigation intervals than did the conventional irrigation.

  • PDF

The Effect of Low Impact Development Techniques on Urban Runoff (저영향개발기법이 도시 유출에 미치는 영향)

  • Kim, Heesoo;Chung, Gunhui
    • Journal of Wetlands Research
    • /
    • v.23 no.4
    • /
    • pp.307-316
    • /
    • 2021
  • Due to rapidly increased urbanization, impervious area has been extended and concerns about urban flooding has been increased as well. A lot of effort has been made to restore the urban water circulation. Low Impact Development (LID) technology that consist of retention, infiltration, and evapotranspiration has begun to attract attention to simulate the hydrologic phenomenon before and after development. Many researches on the technique is being actively conducted. In this study, the effect on reducing runoff in urban catchment was analyzed and evaluated by applying LID techniques using SWMM and six scenarios. A SWMM-LID model was built for the Gasan 1 rainwater pumping station basin, and Green Roof and Permeable Pavement were selected as LID techniques to be applied. As a result, the reduction effect of the permeable pavement was larger than green roof. In the future, the results could be used to design a LID facility using the characteristics of the watershed, and other urban water resource factors such as river and groundwater levels that affect each other should be considered, so that the entire system can be considered.

Evaluation of Soil Disturbance Due to Bucket Installation in Sand (모래지반에서 버켓기초 설치에 의한 지반교란 평가)

  • Kim, Jae-Hyun;Lee, Seung-Tae;Kim, Dong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.11
    • /
    • pp.21-31
    • /
    • 2018
  • Bucket foundations are widely used in offshore areas due to their various benefits such as easy and fast installations. A bucket is installed using self-weight and the hydraulic pressure difference across the lid generated by pumping out water from inside the bucket. When buckets are installed in high permeable soil such as sands, upward seepage flow occurs around the bucket tip and interior, leading to a decrease in the effective stress in the soil inside the buckets. This process reduces the penetration resistance of buckets. However, the soil inside and outside the bucket can be disturbed due to the upward seepage flow and this can change the soil properties around the bucket. Moreover, upward seepage flow can create significant soil plug heave, thereby hindering the penetration of the bucket to the target depth. Despite of these problems, soil disturbance and soil plug heave created by suction installation are not well understood. This study aims to investigate the behavior of soil during suction installation. To comprehend the phenomena of soil plug heave during installation, a series of small-scale model tests were conducted with different testing conditions. From a series of tests, the effects of tip thickness of bucket, penetration rate, and self-weight were identified. Finally, soil properties inside the bucket after installation were approximated from the measured soil plug heave.

Method for Flood Runoff Analysis of Main Channel Connected with Interior Floodplain : I. Application for Analysis of Inundation Area in Interior Floodplain (제내지와 하도를 연계한 하천유역의 홍수유출해석: I. 제내지 침수해석에의 적용)

  • Jang, Su Hyung;Yoon, Jae Young;Yoon, Yong Nam;Kim, Won Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1B
    • /
    • pp.79-88
    • /
    • 2006
  • In this study, a methodology is developed for flood runoff analysis considering the interaction between interior floodplain and channel. Riparian lowland is modeled as storage areas by HEC-RAS and is connected with main channel through gravity drainage structure and pumping stations. As a result, we were able to compute the difference between runoff into the interior floodplain and delayed runoff to main channel from interior floodplain. This allowed us to compute the storage change in the interior floodplain and corresponding inundation areas. Furthermore, the levee is modeled as a lateral structure and the flood from the main channel to interior floodplain is modeled by installing a weir on top of it. In addition, levee breach is also modeled so that flooding from main channel to interior floodplain can be considered. Computed flooding depth in the storage areas are compared with elevation to identify the inundated areas and flood maps can then be produced for a desired time or for the extent of flooding given a flooding depth. Output from this modeling effort can provide many useful information for flood planning such as flow depth in main channel, flooding depth and area in interior floodplain. The method was applied to Sapgyo river basin and the comparison with observed flood events showed that it can reproduce the observation fairly well, hence proving the utility of the method.

Fate and Transport of Cr(VI) Contaminated Groundwater from the Industrial Area in Daejeon (대전 산업단지 지하수의 6가 크롬 오염 및 확산 평가)

  • Chon, Chul-Min;Moon, Sang-Ho;Ahn, Joo-Sung;Kim, Yung-Sik;Won, Jong-Ho;Ahn, Kyoung-Hwan
    • Economic and Environmental Geology
    • /
    • v.40 no.4
    • /
    • pp.403-418
    • /
    • 2007
  • The objective of this research was to characterize the fate and transport of Cr(VI) contaminated groundwater in the Daejeon industrial area. Five subsidiary monitoring wells were newly installed and two existing wells were utilized for the investigation and the reduction process of Cr(VI) contaminated groundwater of the Daejeon(Mun-pyeong) national groundwater monitoring station. The Cr(VI) concentrations at the shallow aquifer well of the station were in the range of 3.2-4.5 mg/L indicating continuous contamination. However, Cr was not detected at the deep bedrock well and the other monitoring wells except MPH-1 and 3. The Cr(VI) concentrations of MPH-1 and MPH-3 were below the drinking water guideline value (0.05 mg/L). Therefore, the plume of the Cr(VI) contaminated groundwater was predicted to be confined within the narrow boundary around the station. The soluble/exchangeable Cr(VI) concentrations were below the detection limit in all core and slime samples taken from the five newly installed wells. Although the exact source of contamination was not directly detected in the study area, the spatial Cr(VI) distribution in groundwater and characteristics of the core samples indicated that the source and the dispersion range were confined within the 100 m area from the monitoring station. The contamination might be induced from the unlined landfill of industrial wastes which was observed during the installation of an subsidiary monitoring well. For the evaluation of the natural attenuation of Cr(VI), available reduction capacities of Cr(VI) with an initial concentration of 5 mg/L were measured in soil and aquifer materials. Dark-gray clay layer samples have high capacities of Cr(VI) reduction ranging from 58 to 64%, which is obviously related to organic carbon contents of the samples. The analysis of reduction capacities implied that the soil and aquifer materials controlled the dispersion of Cr(VI) contamination in this area. However, some possibilities of dispersion by the preferential flow cannot be excluded due to the limited numbers of monitoring wells. We suggest the removal of Cr(VI) contaminated groundwater by periodical pumping, and the continuous groundwater quality monitoring for evaluation of the Cr(VI) dispersion should be followed in the study area.

Effects of the Exercise Training on Aging Heart in Rat I. Long Term Endurance Exercise (운동훈련이 흰쥐 노화심근에 미치는 영향 I. 장기간 지구력 운동 훈련)

  • 박원학;이상선;이용덕
    • Biomedical Science Letters
    • /
    • v.2 no.1
    • /
    • pp.71-90
    • /
    • 1996
  • There is considerable current interest in the effect of regular vigorous exercise and in particular endurance-running as a possible measure in improving myocardial function. Some data indicate that the aging heart may actually suffer from vigorous endurance exercise. On the contrary appropriate exercise in aged animals improves myocardial function and aerobic energy metabolism. So far there is relatively little data to indicate that endurance exercise is in fact beneficial in improving myocardial function or damaging to heart of aged animals. The present investigation aimed to study the possible effect of a long range treadmill training program on the heart in aging rats. Male rats aged 3, 10, and 20 months were divided at random into a control (sedentary) and an exercise group. The training group was exercised for 5 days a week on an automated treadmill for 20minutes at 18m/min over a period of 5 months. The exercise regimen of our experiments did not cause any significant changes in the tissues and ultrastructural as com-pared with sedentary age-matched control. Tissues and ultrastructures of myocardial cells in trained group aged 8 months are intact and well organized as well as sedentary control group. Age associated tissue and ultrastructural changes of trained group aged 15 months included : an increase in transformed mitochondria, vacuoles, lysosomes, lipid droplets and early lipofuscin. But the trained heart did not show significant difference in tissue and ultrastructural properties from those of sedentary controls. Endurance-trained group aged 25 months showed significant qualitative tissue and ultrastructural difference as compared with age-matched controls. In addition to those found in 25 months control group, focal necrosis, myofibril fraying, hypercontraction band, seperation of intercalated discs, degenerating nucleus and infiltration of collagenous fiber into myocyte were noted in trained 25 months group. The stereological examination of the mi-crographs disclosed no significant difference in the myoflbril, mitochondrion, sarcotubule and in-terstitium volume density and surface density of mitochondrial cristae and numerical density of mitochondria between trained and control group aged 8 and 15 months. In the trained 25 months group, significant increase in volume density of interstitium, lipofucsin granule were shown as compared to untrained age-matched control. On the other hand, significant decrease in mitochondrion volume density was shown. The myofibril volume density did not differ between trained and control group although trained group showed slight increase. From the data obtained a reduced mitochondria/myofibrils ratio was found in trained rat heart aged 25 months and there was no difference between trained and control rat aged 15 months. But a slight but not significant increase was found in the trained group aged 8 months as compared with same age control group. Such increase in the ratio in young animals is considered to be of great importance to cardiac pumping and adaptability. Whereas such adaptations don't seem to occur in aged heart muscle. This study proposed that repeated endurance exercise do not cause any significant qualitative and quantitative ultrastructural change of heart muscle in young(3months) and adult (10months) suggesting that the heart is able to adapt to the exercise. On the contrary, the repeated endurance exercise stress may actually induce degenerative changes in the aged heart muscle(20months).

  • PDF