• Title/Summary/Keyword: weighting value

Search Result 350, Processing Time 0.034 seconds

Automatic Selection of Optimal Parameter for Baseline Correction using Asymmetrically Reweighted Penalized Least Squares (Asymmetrically Reweighted Penalized Least Squares을 이용한 기준선 보정에서 최적 매개변수 자동 선택 방법)

  • Park, Aaron;Baek, Sung-June;Park, Jun-Qyu;Seo, Yu-Gyung;Won, Yonggwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.3
    • /
    • pp.124-131
    • /
    • 2016
  • Baseline correction is very important due to influence on performance of spectral analysis in application of spectroscopy. Baseline is often estimated by parameter selection using visual inspection on analyte spectrum. It is a highly subjective procedure and can be tedious work especially with a large number of data. For these reasons, it is an objective and automatic procedure is necessary to select optimal parameter value for baseline correction. Asymmetrically reweighted penalized least squares (arPLS) based on penalized least squares was proposed for baseline correction in our previous study. The method uses a new weighting scheme based on the generalized logistic function. In this study, we present an automatic selection of optimal parameter for baseline correction using arPLS. The method computes fitness and smoothness values of fitted baseline within available range of parameters and then selects optimal parameter when the sum of normalized fitness and smoothness gets minimum. According to the experimental results using simulated data with varying baselines, sloping, curved and doubly curved baseline, and real Raman spectra, we confirmed that the proposed method can be effectively applied to optimal parameter selection for baseline correction using arPLS.

Single-Channel Seismic Data Processing via Singular Spectrum Analysis (특이 스펙트럼 분석 기반 단일 채널 탄성파 자료처리 연구)

  • Woodon Jeong;Chanhee Lee;Seung-Goo Kang
    • Geophysics and Geophysical Exploration
    • /
    • v.27 no.2
    • /
    • pp.91-107
    • /
    • 2024
  • Single-channel seismic exploration has proven effective in delineating subsurface geological structures using small-scale survey systems. The seismic data acquired through zero- or near-offset methods directly capture subsurface features along the vertical axis, facilitating the construction of corresponding seismic sections. However, substantial noise in single-channel seismic data hampers precise interpretation because of the low signal-to-noise ratio. This study introduces a novel approach that integrate noise reduction and signal enhancement via matrix rank optimization to address this issue. Unlike conventional rank-reduction methods, which retain selected singular values to mitigate random noise, our method optimizes the entire singular value spectrum, thus effectively tackling both random and erratic noises commonly found in environments with low signal-to-noise ratio. Additionally, to enhance the horizontal continuity of seismic events and mitigate signal loss during noise reduction, we introduced an adaptive weighting factor computed from the eigenimage of the seismic section. To access the robustness of the proposed method, we conducted numerical experiments using single-channel Sparker seismic data from the Chukchi Plateau in the Arctic Ocean. The results demonstrated that the seismic sections had significantly improved signal-to-noise ratios and minimal signal loss. These advancements hold promise for enhancing single-channel and high-resolution seismic surveys and aiding in the identification of marine development and submarine geological hazards in domestic coastal areas.

Optimal supervised LSA method using selective feature dimension reduction (선택적 자질 차원 축소를 이용한 최적의 지도적 LSA 방법)

  • Kim, Jung-Ho;Kim, Myung-Kyu;Cha, Myung-Hoon;In, Joo-Ho;Chae, Soo-Hoan
    • Science of Emotion and Sensibility
    • /
    • v.13 no.1
    • /
    • pp.47-60
    • /
    • 2010
  • Most of the researches about classification usually have used kNN(k-Nearest Neighbor), SVM(Support Vector Machine), which are known as learn-based model, and Bayesian classifier, NNA(Neural Network Algorithm), which are known as statistics-based methods. However, there are some limitations of space and time when classifying so many web pages in recent internet. Moreover, most studies of classification are using uni-gram feature representation which is not good to represent real meaning of words. In case of Korean web page classification, there are some problems because of korean words property that the words have multiple meanings(polysemy). For these reasons, LSA(Latent Semantic Analysis) is proposed to classify well in these environment(large data set and words' polysemy). LSA uses SVD(Singular Value Decomposition) which decomposes the original term-document matrix to three different matrices and reduces their dimension. From this SVD's work, it is possible to create new low-level semantic space for representing vectors, which can make classification efficient and analyze latent meaning of words or document(or web pages). Although LSA is good at classification, it has some drawbacks in classification. As SVD reduces dimensions of matrix and creates new semantic space, it doesn't consider which dimensions discriminate vectors well but it does consider which dimensions represent vectors well. It is a reason why LSA doesn't improve performance of classification as expectation. In this paper, we propose new LSA which selects optimal dimensions to discriminate and represent vectors well as minimizing drawbacks and improving performance. This method that we propose shows better and more stable performance than other LSAs' in low-dimension space. In addition, we derive more improvement in classification as creating and selecting features by reducing stopwords and weighting specific values to them statistically.

  • PDF

Optimum Fertilization Based on Soil Testing for Chinese Cabbage Cultivation in Plastic Film Houses (시설재배지 토양 검정에 의한 배추의 적정 시비량)

  • Hong, Soon Dal;Kang, Bo Goo;Kim, Jai Joung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.31 no.1
    • /
    • pp.16-24
    • /
    • 1998
  • To determine the optimum application of fertilizers for the cultivation of Chinese cabbage in plastic film house, twenty soils which contain different salts contents were taken from 4 different area of plastic film house cultivation, Youngdong. Boeun county, Cheongweon county, and Cheongju city. The dry weight and the amount of N. P, and K uptakes of Chinese cabbage in the plot of no fertilization were considered as the factors representing the fertility of the soil. And a difference of dry weight and the amounts of N, P, and K uptakes of plants between the plot of fertilization and no fertilization were considered as the factors representing the total effect of fertilizer and fertilizer N, P, and K effects. respectively. These factors of soil fertility and fertilizer effects were estimated by correlation and regression with soil tests in order to find the critical levels and recommended method for optimum fertilization of Chinese cabbage. Chinese cabbage transplanted in two soils, having the electrical conductivity of 9.3 and 15.2 dS/m, were not able to root due to the salts toxicity. The content of inorganic N, the electrical conductivity, and CEC were founded to have significant correlation with the factors of both the soil fertility and fertilizer effects for the cultivation of Chinese cabbage. To determine the weighting degree for the productivity and the fertilizer effects, the standardized partial regression coefficient was analyzed by regression among the factors of fertility, the fertilizer effects, and the soil tests. The coefficient for inorganic N($NH_4-N$ and $NO_3-N$) was obtained as the absolute value of 756-1871 and this value was extremely higher than those of other soil tests which was 0.07-4.11. These results suggested that the content of inorganic N is the best tests for the estimation of the productivity and the fertilizer effects for the cultivation of Chinese cabbage in plastic film house. The critical level of inorganic N($NH_4-N+NO_3-N$) estimated by Cate-Nelson split method for maximum productivity and zero point of fertilizer effect was 220 mg/kg for all the factors of estimation. These results suggested that no application of fertilizer N. P, and K is required at the critical level of inorganic N of soil. Consequently the optimum application of fertilizer N, P, and K for the cultivation of Chinese cabbage in plastic film house was possible to determine by the critical level of inorganic N of soil. The critical level of electrical conductivity was estimated as 2.8 dS/m by the same method.

  • PDF

Effect of xylazine hydrochloride on histamine release (Xylazine이 histamine 유리에 미치는 영향)

  • 김영환;박준형
    • Korean Journal of Veterinary Service
    • /
    • v.25 no.1
    • /
    • pp.53-73
    • /
    • 2002
  • It has been reported that degranulation of mast cells in rats, rabbits and dog was observed after dosing xylazine hydrochloride(Xh) which has been widely used as sedative, analgesic and muscular relaxant. Therefore, this experiment was conducted to examine the relations between Xh and histamine release and to identify the action of ${\alpha}$-adrenoceptors which exists on the suface of mast cells. 1. The content of histamine within serum was measured with HPLC by performing the O-phthalaldehyde(OPA) fluorescent derivation. The pretreatment method had a little modification from the conventional method. The pretreament was carried out in the following method. 0.2$m\ell$ of serum and 1$m\ell$ of butanol were added to mixed together and then the liquid was centrifugally separated at 4$^{\circ}C$ and 2,000 rpm for 3 minutes. 0.4$m\ell$ of 0.1N HCl and 1.6$m\ell$ of heptane were added to 0.8$m\ell$ of supernatant taken from the liquid, and they were mixed together. This mixture was also centrifugally separated at 4$^{\circ}C$ and 2,000 rpm for 5 minutes. The supernatant was thrown away and the OPA fluorescent derivation was carried out with 0.2$m\ell$ of the lower liquid then, 5 minutes after mixing 400${\mu}\ell$ of 0.1N HCl, 120${\mu}\ell$ of 1N NaOH and 40${\mu}\ell$ of 0.1% OPA in the 0.2$m\ell$ of the lower liquid,120${\mu}\ell$ of 3.57N H$_3$PO$_4$ was added to the mixed liquid, and the liquid, was mixed again and syringe-filtered. Then, the measurement was done with HPLC in the 30 : 70(ν/ν) ratio of 0.004M KH$_2$PO$_4$: CH$_3$CN, flow rate of 1.0$m\ell$/min., and a wavelength of λex= 350nm and λem=444nm at the column temperature of 27$^{\circ}C$, using the fluorescence detector. 2. The content of histamine in each laboratory animal appeared to be higher in such an order as rabbit, rat, guinea pig, dog, Korean indigenous goat, swine, Korean indigenous cattle, Holstein, and mouse, of which the individual mean values${\pm}$standard deviation were 2.0668 ${\pm}$ 0.6049. 0.4999 ${\pm}$ 0.2278, 0.4241 ${\pm}$ 0.1974, 0.1054 ${\pm}$ 0.0556, 0.1028 ${\pm}$ 0.0276, 0.0972 ${\pm}$ 0.0513, 0.0872 ${\pm}$ 0.0373, 0.0717 ${\pm}$ 0.0379, and 0.0706 ${\pm}$ 0.0366, respectively. 3. The content of histamine was measured at the moments of 15-, 30-, 60-, 120-minutes after inoamuscular injection of 20mg/100kg Xh into two to 4 years old Holstein weighing 600∼700kg. The result showed that there was a significant increase at the times of 30- and 90-minutes after injection(p<0.05). 4. Intramuscular injection of 3mg/10kg Xh was given to crossbred pug dogs weighing 2.5∼4.3kg. The content of histamine was measured at the times of 30-, 60-, 90- and 120-minutes after injection. The result revealed that there was a significant increase at the times of 60-and 90-minutes after injection(p<0.05). 5. Intramuscular injection of 10mg/$m\ell$∼25mg/$m\ell$ Xh in concentration of 0.1$m\ell$ was applied to Korean indigenous goat over 5 months old. Then, the content of histamine was measured at the times of 15-, 30-, 60- and 90-minutes after injection. A significant increase was shown at the times of 30- and 60-minutes after injection(p<0.05). 6. The content of histamine was measured at the moments of 30- and 60-minutes after intramuscular injection of 0.1-0.2$m\ell$ Xh (20mg/$m\ell$) into male rabbits weighting 2.5-4kg. A significant increase was found at the moment of 60 minutes after injection(p<0.001). 7. After administering Xh to the mast cell taken from the abdominal cavity of mouse, the content of histamine was measured. The result showed that the higher the concentration, the more significantly the content of histamine was increased(p<0.05). 8. Compound 48/80 was administered in concentration of 5$\mu\textrm{g}$/$m\ell$ and 10$\mu\textrm{g}$/$m\ell$ to the mast cell picked from the abdominal cavity of mouse. The result showed that there was a significant increase in the content of histamine in case of the concentration of 10$\mu\textrm{g}$/$m\ell$(p<0.05). It was found to be about 10,000 to 500,000 times stronger than the Xh. 9. After premedication of 1mg/kg of yohimbine hydrochloride as ${\alpha}$$_2$-adrenergic antagonist to rabbits, the Xh was administered to them. The result was that the value of histamine within serum was decreased significantly(p<0.001). 10. After premeditation of 1mg/kg of prazosin hydrochloride as ${\alpha}$$_1$-adrenergic antagonist to rabbits, the Xh was administered to them. It was found that the value of histamine within serum was decreased significantly(p<0.005). 11, Prazosin hydrochloride and yohimbine hydrochloride as ${\alpha}$$_1$-adrenergic antagonist, respectively, and ${\alpha}$$_2$-adrenergic antagonist were administerd. In this case, the value of histamine within serum was decreased significantly(p<0.0001). As the results, when the Xh is administered to various kinds of animals, the amount of histamine release within serum is increased. In view of the results so far achieved, it is concluded that Xh acted on both a$_1$-adrenoreceptor and ${\alpha}$$_2$-adrenoreceptor induces the degranulation of mast cell.

Development of a split beam transducer for measuring fish size distribution (어체 크기의 자동 식별을 위한 split beam 음향 변환기의 재발)

  • 이대재;신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.196-213
    • /
    • 2001
  • A split beam ultrasonic transducer operating at a frequency of 70 kHz to use in the fish sizing echo sounder was developed and the acoustic radiation characteristics were experimentally analyzed. The amplitude shading method utilizing the properties of the Chebyshev polynomials was used to obtain side lobe levels below -20 dB and to optimize the relationship between main beam width and side lobe level of the transducer, and the amplitude shading coefficient to each of the elements was achieved by changing the amplitude contribution of elements with 4 weighting transformers embodied in the planar array transducer assembly. The planar array split beam transducer assembly was composed of 36 piezoelectric ceramics (NEPEC N-21, Tokin) of rod type of 10 mm in diameter and 18.7 mm in length of 70 kHz arranged in the rectangular configuration, and the 4 electrical inputs were supplied to the beamformer. A series of impedance measurements were conducted to check the uniformity of the individual quadrants, and also in the configurations of reception and transmission, resonant frequency, and the transmitting and receiving characteristics were measured in the water tank and analyzed, respectively. The results obtained are summarized as follows : 1. Average resonant and antiresonant frequencies of electrical impedance for four quadrants of the split beam transducer in water were 69.8 kHz and 83.0 kHz, respectively. Average electrical impedance for each individual transducer quadrant was 49.2$\Omega$ at resonant frequency and 704.7$\Omega$ at antiresonant frequency. 2. The resonance peak in the transmitting voltage response (TVR) for four quadrants of the split beam transducer was observed all at 70.0 kHz and the value of TVR was all about 165.5 dB re 1 $\mu$Pa/V at 1 m at 70.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The resonance peak in the receiving sensitivity (SRT) for four combined quadrants (quad LU+LL, quad RU+RL, quad LU+RU, quad LL+RL) of the split beam transducer was observed all at 75.0 kHz and the value of SRT was all about -177.7 dB re 1 V/$\mu$Pa at 75.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The sum beam transmitting voltage response and receiving senstivity was 175.0 dB re 1$\mu$Pa/V at 1 m at 75.0 kHz with bandwidth of 10.0 kHz, respectively. 3. The sum beam of split beam transducer was approximately circular with a half beam angle of $9.0^\circ$ at -3 dB points all in both axis of the horizontal plane and the vertical plane. The first measured side lobe levels for the sum beam of split beam transducer were -19.7 dB at $22^\circ$ and -19.4 dB at $-26^\circ$ in the horizontal plane, respectively and -20.1 dB at $22^\circ$ and -22.0 dB at $-26^\circ$ in the vertical plane, respectively. 4. The developed split beam transducer was tested to estimate the angular position of the target in the beam through split beam phase measurements, and the beam pattern loss for target strength corrections was measured and analyzed.

  • PDF

Development of Work-related Musculoskeletal Disorder Questionnaire Using Receiver Operating Characteristic Analysis (Receiver Operating Characteristic 분석법을 이용한 업무관련성 근골격계질환 설문지 개발)

  • Kwon, Ho-Jang;Ju, Yeong-Su;Cho, Soo-Hun;Kang, Dae-Hee;Sung, Joo-Hon;Choi, Seong-Woo;Choi, Jae-Wook;Kim, Jae-Young;Kim, Don-Gyu;Kim, Jai-Yong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.32 no.3
    • /
    • pp.361-373
    • /
    • 1999
  • Objectives: Receive Operating Characteristic(ROC) curve with the area under the ROC curve(AUC) is one of the most popular indicator to evaluate the criterion validity of the measurement tool. This study was conducted to develop a standardized questionnaire to discriminate workers at high-risk of work-related musculoskeletal disorders using ROC analysis. Methods: The diagnostic results determined by rehabilitation medicine specialists in 370 persons(89 shipyard CAD workers, 113 telephone directory assistant operators, 79 women with occupation, and 89 housewives) were compared with participant's own replies to 'the questionnair on the worker's subjective physical symptoms'(Kwon, 1996). The AUC's from four models with different methods in item selection and weighting were compared with each other. These 4 models were applied to 225 persons, working in an assembly line of motor vehicle, for the purpose of AUC reliability test. Results: In a weighted model with 11 items, the AUC was 0.8155 in the primary study population, and 0.8026 in the secondary study population(p=0.3780). It was superior in the aspects of discriminability, reliability and convenience. A new questionnaire of musculoskeletal disorder could be constructed by this model. Conclusion: A more valid questionnaire with a small number of items and the quantitative weight scores useful for the relative comparisons are the main results of this study. While the absolute reference value applicable to the wide range of populations was not estimated, the basic intent of this study, developing a surveillance fool through quantitative validation of the measures, would serve for the systematic disease prevention activities.

  • PDF

Improved AR-FGS Coding Scheme for Scalable Video Coding (확장형 비디오 부호화(SVC)의 AR-FGS 기법에 대한 부호화 성능 개선 기법)

  • Seo, Kwang-Deok;Jung, Soon-Heung;Kim, Jin-Soo;Kim, Jae-Gon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.12C
    • /
    • pp.1173-1183
    • /
    • 2006
  • In this paper, we propose an efficient method for improving visual quality of AR-FGS (Adaptive Reference FGS) which is adopted as a key scheme for SVC (Scalable Video Coding) or H.264 scalable extension. The standard FGS (Fine Granularity Scalability) adopts AR-FGS that introduces temporal prediction into FGS layer by using a high quality reference signal which is constructed by the weighted average between the base layer reconstructed imageand enhancement reference to improve the coding efficiency in the FGS layer. However, when the enhancement stream is truncated at certain bitstream position in transmission, the rest of the data of the FGS layer will not be available at the FGS decoder. Thus the most noticeable problem of using the enhancement layer in prediction is the degraded visual quality caused by drifting because of the mismatch between the reference frame used by the FGS encoder and that by the decoder. To solve this problem, we exploit the principle of cyclical block coding that is used to encode quantized transform coefficients in a cyclical manner in the FGS layer. Encoding block coefficients in a cyclical manner places 'higher-value' bits earlier in the bitstream. The quantized transform coefficients included in the ealry coding cycle of cyclical block coding have higher probability to be correctly received and decoded than the others included in the later cycle of the cyclical block coding. Therefore, we can minimize visual quality degradation caused by bitstream truncation by adjusting weighting factor to control the contribution of the bitstream produced in each coding cycle of cyclical block coding when constructing the enhancement layer reference frame. It is shown by simulations that the improved AR-FGS scheme outperforms the standard AR-FGS by about 1 dB in maximum in the reconstructed visual quality.

Accessibility Analysis in Mapping Cultural Ecosystem Service of Namyangju-si (접근성 개념을 적용한 문화서비스 평가 -남양주시를 대상으로-)

  • Jun, Baysok;Kang, Wanmo;Lee, Jaehyuck;Kim, Sunghoon;Kim, Byeori;Kim, Ilkwon;Lee, Jooeun;Kwon, Hyuksoo
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.4
    • /
    • pp.367-377
    • /
    • 2018
  • A cultural ecosystem service(CES), which is non-material benefit that human gains from ecosystem, has been recently further recognized as gross national income increases. Previous researches proposed to quantify the value of CES, which still remains as a challenging issue today due to its social and cultural subjectivity. This study proposes new way of assessing CES which is called Cultural Service Opportunity Spectrum(CSOS). CSOS is accessibility based CES assessment methodology for regional scale and it is designed to be applicable for any regions in Korea for supporting decision making process. CSOS employed public spatial data which are road network and population density map. In addition, the results of 'Rapid Assessment of Natural Assets' implemented by National Institute of Ecology, Korea were used as a complementary data. CSOS was applied to Namyangju-si and the methodology resulted in revealing specific areas with great accessibility to 'Natural Assets' in the region. Based on the results, the advantages and limitations of the methodology were discussed with regard to weighting three main factors and in contrast to Scenic Quality model and Recreation model of InVEST which have been commonly used for assessing CES today due to its convenience today.

Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography (전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가)

  • Kim, Jeong Jin;Jang, Seong Won;Park, Jang Heum;Lee, Kwan Seob;Ha, Dong Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF