• Title/Summary/Keyword: weighted standard deviation

Search Result 101, Processing Time 0.021 seconds

A Study on Image Restoration Algorithm using Standard Deviation and Cubic Spline Interpolation (표준편차 및 3차 스플라인 보간법을 이용한 영상 복원 알고리즘에 관한 연구)

  • Kwon, Se-Ik;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.9
    • /
    • pp.1689-1696
    • /
    • 2017
  • In the process of obtaining and transmitting image, there is degradation of image due to various noise, and there have been many active studies ongoing to remove the noise added on the images. This thesis has proposed a switching filter processing by the types of noise in order to remove the complex noise added on images. When the center value of local mask is damaged by AWGN based on the noise judgment, the threshold value is applied on standard deviation of local mask to process by applying different weight of weighted mask, and if the image is damaged by the salt and pepper noise, the local mask is subdivided into 4 directions, and processed by applying cubic spine interpolation in the direction with the least slat and pepper noise. Also, in order to evaluate the performance of proposed filter algorithm, the study conducted comparison among the existing methods and proposed filter using PSNR.

Effect of Number of Measurement Points on Accuracy of Muscle T2 Calculations

  • Tawara, Noriyuki;Nishiyama, Atsushi
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.4
    • /
    • pp.207-214
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the effect of the number of measurement points on the calculation of transverse relaxation time (T2) with a focus on muscle T2. Materials and Methods: This study assumed that muscle T2 was comprised of a single component. Two phantom types were measured, 1 each for long ("phantom") and short T2 ("polyvinyl alcohol gel"). Right calf muscle T2 measurements were conducted in 9 healthy male volunteers using multiple-spin-echo magnetic resonance imaging. For phantoms and muscle (medial gastrocnemius), 5 regions of interests were selected. All region of interest values were expressed as the mean ${\pm}$ standard deviation. The T2 effective signal-ratio characteristics were used as an index to evaluate the magnetic resonance image quality for the calculation of T2 from T2-weighted images. The T2 accuracy was evaluated to determine the T2 reproducibility and the goodness-of-fit from the probability Q. Results: For the phantom and polyvinyl alcohol gel, the standard deviation of the magnetic resonance image signal at each echo time was narrow and mono-exponential, which caused large variations in the muscle T2 decay curves. The T2 effective signal-ratio change varied with T2, with the greatest decreases apparent for a short T2. There were no significant differences in T2 reproducibility when > 3 measurement points were used. There were no significant differences in goodness-of-fit when > 6 measurement points were used. Although the measurement point evaluations were stable when > 3 measurement points were used, calculation of T2 using 4 measurement points had the highest accuracy according to the goodness-of-fit. Even if the number of measurement points was increased, there was little improvement in the probability Q. Conclusion: Four measurement points gave excellent reproducibility and goodness-of-fit when muscle T2 was considered mono-exponential.

Correction of Receiver Gain using Noise′s Standard Deviation for Reconstruction of T$_1$/T$_2$ Maps (T$_1$/T$_2$ maps 의 재구성을 위해 잡음의 표준편차를 이용한 수신 증폭률 보정)

  • 김미나;김성은;신승애;정은기
    • Progress in Medical Physics
    • /
    • v.10 no.3
    • /
    • pp.125-131
    • /
    • 1999
  • T$_1$/T$_2$ weighted images are being used to give the characteristic contrast among the various tissues and the norma;/abnormal tissues. Abnormalities in tissues, in general, accompany the biochemical changes and eventually structural ones in which results in the change in T$_1$ and T$_2$ relaxation times of water protons. It has been suggested that the mapping of T$_1$/T$_2$ values may serve as a possible tool for the quantitative evaluation of the degree of abnormality. On reconstructing T$_1$/T$_2$ maps(or any other MR parametric map), only corresponding variables are to be varied, such as TE for T$_2$, TI or TR for T$_1$ and b-factor for diffusion images. But often the receiver gain is taken for the optimal usage of A/D converter, so that the set of the image data has different receiver gain. It must be corrected before any attempt to reconstruct the maps. Here we developed method of correcting receiver gain variation effect, using the standard deviation of noise on individual image. The resultant T$_1$ and T$_2$ values were very comparable to the other reported values.

  • PDF

How to Combine Diffusion-Weighted and T2-Weighted Imaging for MRI Assessment of Pathologic Complete Response to Neoadjuvant Chemoradiotherapy in Patients with Rectal Cancer?

  • Jong Keon Jang;Chul-min Lee;Seong Ho Park;Jong Hoon Kim;Jihun Kim;Seok-Byung Lim;Chang Sik Yu;Jin Cheon Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.9
    • /
    • pp.1451-1461
    • /
    • 2021
  • Objective: Adequate methods of combining T2-weighted imaging (T2WI) and diffusion-weighted imaging (DWI) to assess complete response (CR) to chemoradiotherapy (CRT) for rectal cancer are obscure. We aimed to determine an algorithm for combining T2WI and DWI to optimally suggest CR on MRI using visual assessment. Materials and Methods: We included 376 patients (male:female, 256:120; mean age ± standard deviation, 59.7 ± 11.1 years) who had undergone long-course CRT for rectal cancer and both pre- and post-CRT high-resolution rectal MRI during 2017-2018. Two experienced radiologists independently evaluated whether a tumor signal was absent, representing CR, on both post-CRT T2WI and DWI, and whether the pre-treatment DWI showed homogeneous hyperintensity throughout the lesion. Algorithms for combining T2WI and DWI were as follows: 'AND,' if both showed CR; 'OR,' if any one showed CR; and 'conditional OR,' if T2WI showed CR or DWI showed CR after the pre-treatment DWI showed homogeneous hyperintensity. Their efficacies for diagnosing pathologic CR (pCR) were determined in comparison with T2WI alone. Results: Sixty-nine patients (18.4%) had pCR. AND had a lower sensitivity without statistical significance (vs. 62.3% [43/69]; 59.4% [41/69], p = 0.500) and a significantly higher specificity (vs. 87.0% [267/307]; 90.2% [277/307], p = 0.002) than those of T2WI. Both OR and conditional OR combinations resulted in a large increase in sensitivity (vs. 62.3% [43/69]; 81.2% [56/69], p < 0.001; and 73.9% [51/69], p = 0.008, respectively) and a large decrease in specificity (vs. 87.0% [267/307]; 57.0% [175/307], p < 0.001; and 69.1% [212/307], p < 0.001, respectively) as compared with T2WI, ultimately creating additional false interpretations of CR more frequently than additional identification of patients with pCR. Conclusion: AND combination of T2WI and DWI is an appropriate strategy for suggesting CR using visual assessment of MRI after CRT for rectal cancer.

Detection of Contralateral Breast Cancer Using Diffusion-Weighted Magnetic Resonance Imaging in Women with Newly Diagnosed Breast Cancer: Comparison with Combined Mammography and Whole-Breast Ultrasound

  • Su Min Ha;Jung Min Chang;Su Hyun Lee;Eun Sil Kim;Soo-Yeon Kim;Yeon Soo Kim;Nariya Cho;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.867-879
    • /
    • 2021
  • Objective: To compare the screening performance of diffusion-weighted (DW) MRI and combined mammography and ultrasound (US) in detecting clinically occult contralateral breast cancer in women with newly diagnosed breast cancer. Materials and Methods: Between January 2017 and July 2018, 1148 women (mean age ± standard deviation, 53.2 ± 10.8 years) with unilateral breast cancer and no clinical abnormalities in the contralateral breast underwent 3T MRI, digital mammography, and radiologist-performed whole-breast US. In this retrospective study, three radiologists independently and blindly reviewed all DW MR images (b = 1000 s/mm2 and apparent diffusion coefficient map) of the contralateral breast and assigned a Breast Imaging Reporting and Data System category. For combined mammography and US evaluation, prospectively assessed results were used. Using histopathology or 1-year follow-up as the reference standard, cancer detection rate and the patient percentage with cancers detected among all women recommended for tissue diagnosis (positive predictive value; PPV2) were compared. Results: Of the 30 cases of clinically occult contralateral cancers (13 invasive and 17 ductal carcinoma in situ [DCIS]), DW MRI detected 23 (76.7%) cases (11 invasive and 12 DCIS), whereas combined mammography and US detected 12 (40.0%, five invasive and seven DCIS) cases. All cancers detected by combined mammography and US, except two DCIS cases, were detected by DW MRI. The cancer detection rate of DW MRI (2.0%; 95% confidence interval [CI]: 1.3%, 3.0%) was higher than that of combined mammography and US (1.0%; 95% CI: 0.5%, 1.8%; p = 0.009). DW MRI showed higher PPV2 (42.1%; 95% CI: 26.3%, 59.2%) than combined mammography and US (18.5%; 95% CI: 9.9%, 30.0%; p = 0.001). Conclusion: In women with newly diagnosed breast cancer, DW MRI detected significantly more contralateral breast cancers with fewer biopsy recommendations than combined mammography and US.

Adaptive Noise Reduction using Standard Deviation of Wavelet Coefficients in Speech Signal (웨이브렛 계수의 표준편차를 이용한 음성신호의 적응 잡음 제거)

  • 황향자;정광일;이상태;김종교
    • Science of Emotion and Sensibility
    • /
    • v.7 no.2
    • /
    • pp.141-148
    • /
    • 2004
  • This paper proposed a new time adapted threshold using the standard deviations of Wavelet coefficients after Wavelet transform by frame scale. The time adapted threshold is set up using the sum of standard deviations of Wavelet coefficient in cA3 and weighted cDl. cA3 coefficients represent the voiced sound with low frequency and cDl coefficients represent the unvoiced sound with high frequency. From simulation results, it is demonstrated that the proposed algorithm improves SNR and MSE performance more than Wavelet transform and Wavelet packet transform does. Moreover, the reconstructed signals by the proposed algorithm resemble the original signal in terms of plosive sound, fricative sound and affricate sound but Wavelet transform and Wavelet packet transform reduce those sounds seriously.

  • PDF

Estimation of Exposure to Nitrogen Dioxide in Professional Drivers Using Time Activity Pattern (시간행동 행태을 이용한 영업용 운전자들의 이산화질소 개인 노출량 예측)

  • 방용남;손부순;양원호;박종안;장봉기
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.1
    • /
    • pp.20-26
    • /
    • 2001
  • personal nitrogen dioxide(NO$_2$) exposures for 31 professional drivers were measured using passive sampler and time activity diary in Asan and Chunan area, and were estimated using time-weighted average model. Mean concentrations of driver’s indoor and outdoor were 24.7$\pm$10.7 ppb and 23.3$\pm$8.3 ppb, respectively with indoor/outdoor of 1.1. Mean personal NO$_2$ exposure was 30.3$\pm$9.7 ppb. Personal NO$_2$ exposures were strongly correlated with indoor car NO$_2$ levels ($R^2$=0.80) rather than residential indoor NO$_2$ level ($R^2$=0.55). and outdoor NO$_2$ level ($R^2$=0.50). The driver’s NO$_2$ exposure using LP-gas with 24.4$\pm$8.0 ppb were statistically different from those using diesel with 36.3$\pm$14.1 ppb(p<0.01). The effect of driver’s smoking for personal NO$_2$ exposure was not found. It was considered that the main NO$_2$in driver is transportation. Since drivers mostly spent their times in indoor and inside car, time-weighted average model could be used to estimated personal NO$_2$ exposure using time activity diary, Though we did not measure all microenvironments, the estimated personal NO$_2$ exposures with 26.9$\pm$10.2 ppb were statistically correlated with measured personal NO $_2$ exposures30.3$\pm$9.7 ppb ($R^2$=0.89). The mean and standard deviation of personal NO$_2$ exposure using Mote-Carlo simulation were 26.6$\pm$7.2 ppb.

  • PDF

Merging Radar Rainfalls of Single and Dual-polarization Radar to Improve the Accuracy of Quantitative Precipitation Estimation (정량적 강우강도 정확도 향상을 위한 단일편파와 이중편파레이더 강수량 합성)

  • Lee, Jae-Kyoung;Kim, Ji-Hyeon;Park, Hye-Sook;Suk, Mi-Kyung
    • Atmosphere
    • /
    • v.24 no.3
    • /
    • pp.365-378
    • /
    • 2014
  • The limits of S-band dual-polarization radars in Korea are not reflected on the recent weather forecasts of Korea Meteorological Administration and furthermore, they are only utilized for rainfall estimations and hydrometeor classification researches. Therefore, this study applied four merging methods [SA (Simple Average), WA (Weighted Average), SSE (Sum of Squared Error), TV (Time-varying mergence)] to the QPE (Quantitative Precipitation Estimation) model [called RAR (Radar-AWS Rainfall) calculation system] using single-polarization radars and S-band dual-polarization radar in order to improve the accuracy of the rainfall estimation of the RAR calculation system. As a result, the merging results of the WA and SSE methods, which are assigned different weights due to the accuracy of the individual model, performed better than the popular merging method, the SA (Simple Average) method. In particular, the results of TVWA (Time-Varying WA) and TVSSE (Time-Varying SSE), which were weighted differently due to the time-varying model error and standard deviation, were superior to the WA and SSE. Among of all the merging methods, the accuracy of the TVWA merging results showed the best performance. Therefore, merging the rainfalls from the RAR calculation system and S-band dual-polarization radar using the merging method proposed by this study enables to improve the accuracy of the quantitative rainfall estimation of the RAR calculation system. Moreover, this study is worthy of the fundamental research on the active utilization of dual-polarization radar for weather forecasts.

Intelligent Traffic Light Control using Fuzzy Method (퍼지 기법을 이용한 지능형 교통 신호 제어)

  • Kim, Kwang-Baek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.8
    • /
    • pp.1593-1598
    • /
    • 2012
  • In this paper, we propose an intelligent signal control method based on fuzzy logic applicable in real time. We design membership functions to model occupied time and the number of vehicles for each lane. A priority for each signal phase is computed by the popular Max-Min fuzzy inference based on control rules and membership degrees of prepared two functions at any given time. A tie breaking scheme is considering weighted sum of the rate of occupied time per number of vehicles in that block and the standard deviation of these blocks. Only a signal phase with the highest priority is opened and all others are closed and the duration of the phase opening is computed proportional to the rate of number of weighting vehicles in that signal per all weighted vehicles. The simulation result shows that the proposed method is more efficient than the static control in all simulation conditions in $2{\times}3$ experimental designs with the number of vehicles in intersection and congestion degrees that have all three levels.

Comparison of Composite Methods of Satellite Chlorophyll-a Concentration Data in the East Sea

  • Park, Kyung-Ae;Park, Ji-Eun;Lee, Min-Sun;Kang, Chang-Keun
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.6
    • /
    • pp.635-651
    • /
    • 2012
  • To produce a level-3 monthly composite image from daily level-2 Sea-viewing Wide Field-of-view Sensor (SeaWiFS) chlorophyll-a concentration data set in the East Sea, we applied four average methods such as the simple average method, the geometric mean method, the maximum likelihood average method, and the weighted averaging method. Prior to performing each averaging method, we classified all pixels into normal pixels and abnormal speckles with anomalously high chlorophyll-a concentrations to eliminate speckles from the following procedure for composite methods. As a result, all composite maps did not contain the erratic effect of speckles. The geometric mean method tended to underestimate chlorophyll-a concentration values all the time as compared with other methods. The weighted averaging method was quite similar to the simple average method, however, it had a tendency to be overestimated at high-value range of chlorophyll-a concentration. Maximum likelihood method was almost similar to the simple average method by demonstrating small variance and high correlation (r=0.9962) of the differences between the two. However, it still had the disadvantage that it was very sensitive in the presence of speckles within a bin. The geometric mean was most significantly deviated from the remaining methods regardless of the magnitude of chlorophyll-a concentration values. Its bias error tended to be large when the standard deviation within a bin increased with less uniformity. It was more biased when data uniformity became small. All the methods exhibited large errors as chlorophyll-a concentration values dominantly scatter in terms of time and space. This study emphasizes the importance of the speckle removal process and proper selection of average methods to reduce composite errors for diverse scientific applications of satellite-derived chlorophyll-a concentration data.