• Title/Summary/Keyword: weight determination

Search Result 724, Processing Time 0.028 seconds

Body Impedance Measurements for edematous patients (부종환자에서 임피던스를 이용한 수분변화의 예측)

  • 오중환
    • Journal of Chest Surgery
    • /
    • v.28 no.11
    • /
    • pp.973-976
    • /
    • 1995
  • The assessment method of human body composion by bioelectrical impedance is very simple, safe, rapid and noninvasive. Based on prediction formulas for total body water from bioelectrical impedance, the observed weight loss should be associated with an increase in impedance. However in edematous patients for dialysis, the calculated total body water loss as calculated from impedance were overestimated and significantly higher than the weight loss after dialysis. So determination of impedance were made in 50 edematous patients before, during and after dialysis. Mean weight loss, which was assumed to be only loss of water was 1719$\pm$ 866 gr and mean impedance change was 71.0 $\pm$ 23.0 Ohm under 50kHz. Body weight loss was highly correlated [r>0.81 with the increase in body impedance under variable frequencies[1, 10, 20, 30, 40, 50 kHz . But there were no differences between frequences. In conclusion, clinical application of bioelectrical impedance method is useful for individual edematous patients with new correlation equation[Y=230+26.8X, X;Impedance change, Y;Calculated total body water loss .

  • PDF

가중함수법에 의한 볼트 체결부 균열의 임계 경사각 결정에 관한 연구

  • Heo, Seong-Pil;Yang, Won-Ho;Jeong, Gi-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.9 s.180
    • /
    • pp.2344-2352
    • /
    • 2000
  • Mechanical joints such as bolted or riveted joints are widely used in mechanical components. The reliable determination of the stress intensity factors for cracks in bolted joints is needed to evaluate the safety and fatigue life of them. The weight function method is an efficient technique to calculate the stress intensity factors for various loading conditions because only the stress analysis of an uncracked model is required. In this paper the mixed-mode stress intensity factors for cracks in bolted joints are obtained by weight function method, in which the coefficients of weight function are determined by finite element analyses for reference loadings. Critical inclined angle that mode I stress intensity factor becomes maximum is determined and the effects of crack length and the magnitude of clearance on critical inclined angle are investigated.

A Study on Weight of Consideration Factors in Layout Development for Machinery Industries using Improvemant-type Heuristics (개선형 탐색법에 의한 기계공장 배치안 작성시 고려요소별 가중치의 크기에 관한 연구)

  • Moon, Gee-Ju
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.20 no.2
    • /
    • pp.109-123
    • /
    • 1995
  • Weight of the factors to be considered in layout development with improvement-type heuristics is discussed in this paper. Determination of weight is especially important if it is designed to be used with an improvement-type heuristic. It is same as the value of variable coefficients in a multi-objective function as well as indices for departmental switching orders in the heuristic. Various weights are examined through computer simulation to verify whether the numerical values collected from machinery industries can be used as weights. And then a method to be used for searching an optimum or optimum-tending layout for machinery industries is presented using the weight.

  • PDF

Determination of Double-K Fracture Parameters of Concrete Using Split-Tension Cube: A Revised Procedure

  • Pandey, Shashi Ranjan;Kumar, Shailendra;Srivastava, A.K.L.
    • International Journal of Concrete Structures and Materials
    • /
    • v.10 no.2
    • /
    • pp.163-175
    • /
    • 2016
  • This paper presents a revised procedure for computation of double-K fracture parameters of concrete split-tension cube specimen using weight function of the centrally cracked plate of finite strip with a finite width. This is an improvement over the previous work of the authors in which the determination of double-K fracture parameters of concrete for split-tension cube test using weight function of the centrally cracked plate of infinite strip with a finite width was presented. In a recent research, it was pointed out that there are great differences between a finite strip and an infinite strip regarding their weight function and the solution of infinite strip can be utilized in the split-tension specimens when the notch size is very small. In the present work, improved version of LEFM formulas for stress intensity factor, crack mouth opening displacement and crack opening displacement profile presented in the recent research work are incorporated. The results of the double-K fracture parameters obtained using revised procedure and the previous work of the authors is compared. The double-K fracture parameters of split-tension cube specimen are also compared with those obtained for standard three point bend test specimen. The input data required for determining double-K fracture parameters for both the specimen geometries for laboratory size specimens are obtained using well known version of the Fictitious Crack Model.

Sexual Differences of Cocoon weight, Cocoon Shell Weight, and Cocoon Shell Percentage in the Sex- limited Silkworm Strains, Bombyx mori L., (한성계통의 전견중, 견층중, 견층비율에 대한 성차)

  • 이상몽;김삼은
    • Journal of Sericultural and Entomological Science
    • /
    • v.27 no.1
    • /
    • pp.31-36
    • /
    • 1985
  • Using sexual differences between female and male as the indication of the degree of the physiological distrubance in the sex-limited larval marking strains or sex-limited egg colour strains, it was investigated whether the physiological distrubance caused y the translocated autosome fragment on the W-sex determination chromosome, have an effect on expression of the three quantitative characters; cocoon weight, cocoon shell weight, and cocoon shell percentage in the female silkworm. The mean values of the ratios of female to male the above two experimental groups were 127%, 107%, 85%, in cocoon shell weight, and cocoon shell percentage, respectively. On the other hand, those from the three normal stains, namely the basic stock strains, white egg strains, and hybrids were 129% for cocoon weight, 110% for cocoon shell weight, and 85% for cocoon shell percentage, respectively. From the results, it comes to the conclusion that the translocated autosome fragment on the W-chromosome has no influences on the expression of the quantitative characters of the female silkworm because sexual differences of the sex-limited strains were very similar to those of the three normal strains.

  • PDF

Estimation of Body Weight Using Body Volume Determined from Three-Dimensional Images for Korean Cattle (한우의 3차원 영상에서 결정된 몸통 체적을 이용한 체중 추정)

  • Jang, Dong Hwa;Kim, Chulsoo;Kim, Yong Hyeon
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.393-400
    • /
    • 2021
  • Body weight of livestock is a crucial indicator for assessing feed requirements and nutritional status. This study was performed to estimate the body weight of Korean cattle (Hanwoo) using body volume determined from three-dimensional (3-D) image. A TOF camera with a resolution of 640×480 pixels, a frame rate of 44 fps and a field of view of 47°(H)×37°(V) was used to capture the 3-D images for Hanwoo. A grid image of the body was obtained through preprocessing such as separating the body from background and removing outliers from the obtained 3-D image. The body volume was determined by numerical integration using depth information to individual grid. The coefficient of determination for a linear regression model of body weight and body volume for calibration dataset was 0.8725. On the other hand, the coefficient of determination was 0.9083 in a multiple regression model for estimating body weight, in which the age of Hanwoo was added to the body volume as an explanatory variable. Mean absolute percentage error and root mean square error in the multiple regression model to estimate the body weight for validation dataset were 8.2% and 24.5kg, respectively. The performance of the regression model for weight estimation was improved and the effort required for estimating body weight could be reduced as the body volume of Hanwoo was used. From these results obtained, it was concluded that the body volume determined from 3-D of Hanwoo could be used as an effective variable for estimating body weight.

Simultaneous determination and acute toxicity study of Fructus mume extracts in ICR mice (오매(烏梅)의 다성분동시분석 및 마우스를 이용한 경구 단회투여 급성독성시험)

  • Lee, In-Sun;Han, Chang-Hyun;Lee, Chul;Hwang, Bang-Yeon;Jung, Sang-Hyeok;Lee, Young-Joon;Jeon, Won-Kyung
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.15 no.1
    • /
    • pp.37-47
    • /
    • 2011
  • Objectives : Previous studies have shown that Fructus mume (FM) has anti-platelet effects. The present study was performed to determine the acute oral toxicity and quality control of a crude extract of FM in ICR mice. Methods : We investigated the in vivo single dose acute toxicity of FM 95% ethanol extract. This test was orally administered once by gavage to 20 male and 20 female mice at dose levels of 0 (control group), 1250, 2500 and 5000mg/kg body weight, respectively. Mortalities, clinical findings, autopsy findings and body weight changes were monitored daily for the 14 days following the administration. HPLC analysis was performed for the simultaneous determination of ursolic acid and p-hydroxycinnamic acid in FM. Reverse-phase chromatography using a C18 column and photodiode array detection at 211 nm was used for quantification of the two maker components. The mobile phase for gradient elution consists of water and acetonitrile. Results : We observed survival rates, general toxicity, change of body weight, and autopsy. The mice did not die after single oral administration of maximum dose of FM. Autopsy of animal revealed no abnormal gross finding. Therefore, $LD_{50}$ value of FM for ICR mice was more than 5000mg/kg on oral route. The HPLC analysis showed that ursolic acid and p-hydroxycinnamic acid amounts to 9.75- and 0.12% in the extract with the retention times of 47.99- and 15.38 minutes, respectively. Conclusions : These results suggest that no toxic dose level of FM in mice is considered to be more than 5000mg/kg. Consequently, it was concluded that FM have no effect on acute toxicity and side effect in ICR mice. For the quality control of FM extract, simultaneous determination of ursolic acid and p-hydroxycinnamic acid was established.

Estimation of Standard Length-Weight Relationships of 10 Freshwater Fish in the South Korea for Application of Relative Weight Index (한국 담수어류 10종의 상대 무게지수(Relative weight index) 활용을 위한 표준 길이-무게 상관관계(Standard Length-Weight relationships) 산출)

  • Baek, Seung-Ho;Park, Sang-Hyeon;Kim, Jeong-Hui
    • Korean Journal of Ichthyology
    • /
    • v.32 no.2
    • /
    • pp.55-62
    • /
    • 2020
  • The Relative weight index is an index for evaluating nutritional condition of fish by calculating a ratio of observed weight to standard weight. The purpose of this study is estimating standard Length-Weight relationships (standard LWRs) to calculate standard weight for application of relative weight index and analyze frequency distribution of relative weight index of 10 freshwater fish in the South Korea. The standard LWRs for each species was calculated by the Length-Weight data sets from 798 times of captures at 141 sites. The correlation of determination (r2) for all species was over 0.9 and values of parameter b were within the expected range according to Froese (2006). We calculated in increments of 10 from 10 to 90 percentile of relative weight index for each species, and it could be used as a standard for quantitative assessment of nutritional condition of freshwater fish.

Spectrophotometric Determination of Iridium After Extraction of the Stannous-Chloro Complex by High Molecular Weight Amine (고분자량 아민에 의한 이리듐 제1염화주석 착물에 추출 및 분광광도법에 의한 이리듐의 정량법)

  • Kang Hyung Kun;Koo Soon Chung
    • Journal of the Korean Chemical Society
    • /
    • v.19 no.5
    • /
    • pp.343-350
    • /
    • 1975
  • About 20${\sim}$100${\mu}g$ iridium have been extracted quantitatively as stannous-chloro Complex from aqueous solution by Alamine-336, a high molecular weight tertiary amine, dissolved in benzene. The extractability was confirmed by radioactive tracer of iridium-192. The spectrophotometric measurements of the extracted species at 322.5 nm indicate the feasibility of this method to be used as an analytical procedure for the determination of micro amount of iridium. An anion model of stannous-chloro complex of iridium has been postulated to account for the extraction mechanism.

  • PDF