• Title/Summary/Keyword: weighing method

Search Result 282, Processing Time 0.025 seconds

Repair of Closed Bilateral Mandibular Fractures Using Bone Plate and Screw in Dogs (개에서 골판을 이용한 비개방성 양측성 하악골절의 수복)

  • 정순욱;한현정;김지선;김준영;정만복
    • Journal of Veterinary Clinics
    • /
    • v.20 no.1
    • /
    • pp.138-141
    • /
    • 2003
  • First case, a one-year-old female Shih Tzu weighing 3 kg with closed transverse fractures of bilateral mandibular body between 2nd and 3rd premolar teeth were treated surgically with bone plates and screws, and cranial luxation of temporomandibular joints were reduced to closed method. Second case, a 8.4 years old male Yorkshire terrier weighing 2.6 kg with closed transverse/oblique fractures of bilateral mandibular body between premolar and molar teeth were treated surgically with bone plates and screws. Radiographic examination revealed that the fractures in two cases fixed well and temporomandibular joint was stabilized. One month after operation, jaw activity was excellent and malocclusion wasn't observed.

Development of Speed and Precision in the Mass Measurement of Moving Object (이송 물체의 질령 측정 속도 및 정밀도 향상 모사 연구)

  • Lee, Woo Gab;Chung, Jin Wan;Kim, Kwang Pyo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.6
    • /
    • pp.136-142
    • /
    • 1994
  • This study presents an algorithm and related techniques which could satisfy the important properties of check weighers and conveyor scales. The algorithm of Recursive Least Squares Regression is described for te weighing system simulated as a dynamic model of the second order. Using the model and the algorithm, model parameters and then the mass being weighed can be determined from the step input. The performance of the algorithm is illustrated in digital simulation. Discussions are extended to the development of fast converging algorithm. It turns out that the algorithm shows several desirable features suitable for microcomputer assisted real-time signal processing, which are high precision and stability in noisy environment.

  • PDF

Development of Frequency Weighing Sensor and Single Crystal Growth (새로운 무게센서 재발과 단결정성장(1))

  • Jang Y.N.;Sung N.H.;Chae S.C.;Bae I.K.;Kim I.J.
    • Korean Journal of Crystallography
    • /
    • v.8 no.1
    • /
    • pp.38-47
    • /
    • 1997
  • A new weighing sensor for the automatic diameter control system of the crystal growth is developed in this study. This weighing sensor measures the frequency of the vibrating element which is lineally changing with respect to weight. The signal and the power of this system are transmitted without any physical contact, so that this sensor offers high accuracy and resolution. This system consists of a string, a sinusoidal wave generator, an automatic amplification adjusting circuit, signal transformers and a PCB. 4 kinds of programs are developed for checking DAC, weight calibration and controlling growth process. The measurements of the standard deviation and the resolution show $\pm0.10g$(measured at every second) and $5{\times}10^{-5}$, respectively, This weighing sensor is effective under high pres-sure of 200 atm, high temperature and vacuum condition. The weighing system can control the temperature in the accuracy of $\pm0.025^{\circ}C$ with the 'signal divider'. The optical quality single crystals of $(YGd)_3Sc_2Ga_3O_{12},\;Er-Y_3Sc_2Al_3O_{12},\;and\;Bi_{12}GeO_{20}$ have been grown by Czo-chralski method using this auto-diameter control system.

  • PDF

A Study on the Development and the Uncertainty Analysis of Oil Flow Standard System (기름 유량표준장치의 개발 및 측정 불확도에 관한 연구)

  • Lim, Ki-Won;Choi, Jong-Oh
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1071-1080
    • /
    • 2003
  • A national standard system was developed in order to calibrate and test the oil flowmeters for the petroleum field. A stop valve and a gyroscopic weighing scale were employed for the primary standard of the flow quantity. It is operated by the standing start and finish mode and the static weighing method. The model equation for uncertainty evaluation was based on the calibration principle of standard system. The sources of the uncertainties were quantified and combined according to the GUM(Guide to the Expression of Uncertainty in Measurement). It was found that the standard system had the relative expanded uncertainty of 0.04 % in the range of 18 - 350 ㎥/h. According to the uncertainty budget, the uncertainties of the fluid density and the volume of pipeline, which were temperature dependent, contributed 92% of final uncertainty in the oil flow standard system.

Parallelism Error Compensation for Force Measurement by Electromagnetic Compensation (전자기력 보상방식의 힘 측정을 위한 평행도 오차 보상)

  • 최인묵;우삼용;김부식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1051-1054
    • /
    • 2003
  • For micro-weighing, null balance method is widely used in the precision industrial fields, such as biomedicine, semiconductor, chemistry and so on. In order to obtain high resolution and large measurement range simultaneously, the mechanism should be analyzed and optimized. However, large measurement error can be generated according to the mass loading position and this error is called as a corner loading error. The corner loading error is caused by the parallelism error of a Roberval mechanism used to minimize it. The corner loading error is one of the most dominant error sources that should be removed. It is possible to design that the mechanism has no corner loading error theoretically, but the mechanism of the micro weighing device is very difficult to be realized as original design due to assembling and manufacturing error. For the required specification of the device, the precise manufacturing technique under a few $\mu\textrm{m}$ is required for the realization of the design. In this paper, the effects of the parallelism error are analyzed by using Lagrange method and verified by experiment. Also, the compensation mechanism is proposed and the corner loading error is reduced by restoring tile parallelism.

  • PDF

Uncertainty Evaluation of the Analysis of Methamphetamine and Amphetamine in Human Hair by GC/MS (GC/MS를 이용한 모발 중 메스암페타민 및 암페타민 분석의 측정불확도 평가)

  • Kim, Jin-Young;Kim, Jong-Sang;Kim, Min-Kyoung;Lee, Jae-Il;Suh, Yong-Jun;In, Moon-kyo
    • YAKHAK HOEJI
    • /
    • v.51 no.3
    • /
    • pp.206-213
    • /
    • 2007
  • Recently estimating the uncertainty of an analytical result has become an essential part of quantitative analysis. This study describes the uncertainty of the measurement for the determination of methamphetamine and its major metabolite amphetamine in human hair, The method consists of washing, drying, weighing, incubation and extraction with methanolic HCI solution, clean-up, trifluoroacetyl derivatization, and qualification/quantification of residues by gas chromatography/mass spectrometry (GC/MS). Traceability of measurement was established through traceable standards and calibrated volumetric equipment and measuring instruments. Measurement uncertainty associated with each analyte in real samples was estimated using quality control (QC) data. The main source of combined standard uncertainty comprised two components, which are uncertainties associated with calibration linearity and variations in QC, while those associated with preparation of analytical standards and sample weighing were not so important considering the degree of contribution. Relative combined standard uncertainties associated with the described method ranged for individual analytes from 4.99 to5.03%.

A study on the measurement method of raw laver weight using load cell (로드셀을 이용한 생김 중량측정 방법에 관한 연구)

  • Eun-Bi MIN;Tae-Jong KANG;Eun-A YOON;Ok-Sam KIM;Doo-Jin HWANG
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.59 no.3
    • /
    • pp.215-220
    • /
    • 2023
  • This study developed and evaluated a load cell-based automatic weighing system for the automated harvesting of laver (Porphyra tenera) in seaweed aquaculture. The current manual harvesting process was compared with the load cell-based automated system, and quantitative measurements of time, distance, and weight were conducted. The results demonstrated that the load cell-based system reduced the unloading time and increased the throughput compared to the manual method. In addition, statistical analysis confirmed that there was no significant difference from the mean in the weight measurement obtained using the load cell-based system. Based on these findings, the load cell-based automatic weighing system holds potential for efficient production and transactions in laver cultivation, contributing to cost reduction and improving the quality of life for aquaculture workers.

Uncertainty Evaluation of Ammonia Determination in Burley Tobacco (버어리종 담배중 암모니아성 질소에 대한 불확도 측정)

  • Lee Jeong-Min;Lee Kyoung-Ku;Han Sang-Bin
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.27 no.1 s.53
    • /
    • pp.107-114
    • /
    • 2005
  • The uncertainty of measurement in quantitative analysis of ammonia by continuous-flow analysis method was evaluated following internationally accepted guidelines. The sources of uncertainty associated with the analysis of ammonia were the weighing of sample, the preparation of extracting solution, the addition of extracting solution into the sample, the reproducibility of analysis and the determination of water content in tobacco, etc. In calculating uncertainties, Type A of uncertainty was evaluated by the statistical analysis of a series of observation, and Type B by the information based on supplier's catalogue and/or certificated of calibration. It was shown that the main source of uncertainty was caused by the volume measurement of 1 mL and 2 mL, the purity of ammonia reference material in the preparation of standard solution, the reproducibility of analysis and the determination of water content of tobacco. The uncertainty in the addition of extraction solution, the sample weighing, the volume measurement of 50 mL and 100 mL, and the calibration curve of standard solution contributed relatively little to the overall uncertainty. The expanded uncertainty of ammonia determination in burley tobacco at $95\%$ level of confidence was $0.00997\%$.

Studies on Automatization of Dairy Cattle Farming 1. Development of Automatic System for Diagnosis of Pregnancy and Diseases (젖소 사양기술의 자동화를 위한 연구 1. 임신유지 여부 및 질병자동진단 시스템개발)

  • 김용준;유일정;정길도;한병성;김동원;김명순
    • Journal of Veterinary Clinics
    • /
    • v.14 no.2
    • /
    • pp.301-307
    • /
    • 1997
  • These studies were performed to provide some basic informations for developing an automatic system in dairy farming cattle in order that the farmers may easily and automatically detect the maintenance of pregnancy and the fact of abortion of the pregnant cows and also to find out the diseased animals with fever. As a method of automatical detection of the maintenance of pregnancy or the fact of abortion, weighing the pregnant cows was conducted from one month-pregnancy to the term using a digital balance. From the first to the 3rd month of pregnancy the body weight of dairy cows was slowly increased (less than 2% per month), then, relatively high increase (3.4% -4.3% per month) from the fourth to the seventh month followed by decrease (3.3%) in the 8th month and very low increase (0.8-0.9%) from the 9th month to the term were shown, resulting in increase of 128.8 kg (25.05%) of body weight to be compared with the first weight. More than 107, increase of body weight to be compared with the first month-weight was denoted from the 61th month of pregnancy and more than 20% increase from the 7th or the 8th month of pregnancy as wells consequently it was presumed that detection of the maintenance of pregnancy is possible from the 4th or the 5th month of pregnancy. It was possible to diagnose a cow aborted at the 6th month by continual weighing the cow from the 1st month of pregnancy. The calved cows showed considerably higher decrease of body weight even in the third week after parturition (p<0.01)to be compared with the body weight near to the term (81.8-102.0 kg, 14-16% decrease). During the same period of 8months, the pregnant cows gained 127.4 kg (24.78% increase), whereas the non-pregnant cows gained 33.0 kg (0.71% increase) to be compared with the first weight showing considerably higher increase of body weight gain in the pregnant cows than the non-pregnant cows (p<0.01). The statistics of body temperatures of dairy cattle were collected from three clinics including the Teaching Hospital of Chonbuk University and the diseases were classified simply by the major symptoms manifested, denoting the highest temperature in respiratory disease ($39.8{\circ}C$) and the lowest in alimentary disease ($39.6{\circ} C$). These informations of body temperatures were expected to be of value for early and automatical detection of the diseased animals with fever when automatic machinery would be established. The results of periodic weighing the body weight of pregnant cows while milking were also expected to be of great use for the farmers to detect the maintenance of pregnancy and the fact of abortion when the automatic system is established in the near future.

  • PDF