• Title/Summary/Keyword: wedge

Search Result 1,451, Processing Time 0.037 seconds

A Novel Skewed-Type Iron Slot Wedge for Permanent Magnet Synchronous Generators for Improving Output Power and Reducing Cogging Torque

  • Kang, Sun-Il;Moon, Jae-Won;You, Yong-Min;Lee, Jin-Hee;Kwon, Byung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.243-250
    • /
    • 2015
  • This paper proposes a novel skewed-type iron slot wedge that can improve both the cogging torque and the output power of a permanent magnet synchronous generator (PMSG). Generally the open slot structure is adopted in a PMSG due to its convenient winding work, but the high cogging torque is undesired. Firstly, an iron slot wedge was utilized to reduce the cogging torque of an open slot type PMSG. However, the output power of the machine decreased rapidly with this method. Thus, a proposed skewed type iron slot wedge is presented to improve the output power as well as the cogging torque as compared to the open slot type. Shape optimization of the skewed-type iron slot wedge is performed to simultaneously maximize the output power and reduce the cogging torque. The Kriging model based on the Halton sequence method and a genetic algorithm are used to optimize the design.

Aerodynamic Characteristics of Supersonic Jets Impinging on $60^{\cire}$ Wedge (꼭지각이 $60^{\cire}$인 쐐기에 충돌하는 초음속 제트의 공기역학적 특성)

  • 박종호;이택상;김윤곤
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.8 no.1
    • /
    • pp.8-15
    • /
    • 2004
  • Supersonic jets impinging on $60^{\cire}$ wedge were investigated to obtain fundamental design data for jet deflector It was of interest to study flow phenomena such as shock interaction and separation induced by shear layer. Experiments using supersonic cold flow system were conducted for Schlieren flow visualization and measurement of surface pressure. Numerical results were compared with the experimental results. The major parameters are underexpansion ratio, distance from nozzle to apex and design Mach number. Flow conditions were obtained for the wedge shock to attach on or detach from the wedge. The dominant feature of flow-field is shock pattern induced by the Interaction between the wedge shock and the barrel shock.

The Results of the First Ray Forefoot Osteotomy Using Low Profile Wedge Plate without a Bone Grafting for Pes Planus Correction (제 1열 전족부 절골술을 통한 평발 교정에 있어 골이식 없이 사용한 소형 쐐기형 금속판의 치료 결과)

  • Choi, Jun Young;Shin, Myung Jin;Suh, Jin Soo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.21 no.1
    • /
    • pp.7-11
    • /
    • 2017
  • Purpose: We retrospectively analyzed the radiographic and clinical results after the first ray of forefoot osteotomy using low profile wedge plate without additional cancellous bone grafting for pes planus correction. Materials and Methods: Twenty-four patients were enrolled in this study. Medial cuneiform opening wedge osteotomy was performed in 12 patients (Cotton osteotomy, group C) and first metatarsal base osteotomy was performed in 12 patients (group MT). Results: On average, the wedge size was 5.61 mm (5~6 mm). The mean time to radiographic union was 3.18 and 3.27 months in groups C and MT, respectively. Postoperative talonavicular coverage angle, talo-first metatarsal angle (anteroposterior), talo-first metatarsal angle (lateral), talo-calcaneal angle (lateral), medial cuneiform height, and American orthopaedic foot, as well as ankle society midfoot scale were significantly improved in both groups. Nonunion, delayed union or fixation failure was not presented in our series. Conclusion: We have shown that low profile wedge plate was effective in the case of first ray forefoot osteotomy for pes planus correction without any additional cancellous bone grafting.

Laparoscopic Gastric Wedge Resection and Prophylactic Antireflux Surgery for a Submucosal Tumor of Gastroesophageal Junction

  • Lee, Jeong-Sun;Kim, Jin-Jo;Park, Seung-Man
    • Journal of Gastric Cancer
    • /
    • v.11 no.2
    • /
    • pp.131-134
    • /
    • 2011
  • A laparoscopic wedge resection for a submucosal tumor, which is close to the gastroesophageal junction, is technically challenging. This can be a dilemma to both patients and surgeons when the tumor margin involves the gastroesophageal junction because a wedge resection in this situation might result in a deformity of the gastroesophageal junction or an injury to the lower esophageal sphincter, which ultimately results in lifelong gastroesophageal reflux disease. The patient was a 42 year-old male, whose preoperative endoscopic ultrasonographic finding did not rule out a gastrointestinal stromal tumor. He underwent a laparoscopic gastric wedge resection and prophylactic anterior partial fundoplication (Dor) and was discharged from hospital on the fifth postoperative day without any complications. There were no symptoms of reflux 5 months after surgery. A laparoscopic wedge resection and prophylactic anti-reflux surgery might be a good surgical option for a submucosal tumor at the gastroesophageal junction.

Calculation of Diffraction Patterns for Incidence of Planewave on Both Sides of a Dielectric Wedge by Using the Neumann Expansion (쇄기형 유전체의 앙면에 평면파 입사시 Neumann전개를 이용한 회절패턴 계산)

  • Kim, Se-Yun;Ra, Jung-Woong
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.5
    • /
    • pp.23-31
    • /
    • 1989
  • The electromagnetic diffraction problem for the incidence of E-polarized planewave on both interfaces of an arbitrary-angled dielectrc wedge is solved in conjunction with the edge condition near the tip of dielectric wedge in the static limit. The diffraction coefficients obtained by the tip of the wedge, the diffraction coefficients presented in this paper approach more closely to the exact pattem of a perfectly conducting wedge as the relative dielectric constants of the dielectric wedge increase.

  • PDF

Biomechanical Effect on Knee Adduction Moment by Lateral Wedge Insole in Transfemoral Amputee (외측웨지인솔이 대퇴절단자의 무릎내전모멘트에 미치는 영향)

  • Chang, Yun-Hee;Lee, Wan-Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.2
    • /
    • pp.239-244
    • /
    • 2012
  • The prevalence of knee osteoarthritis was higher people with lower limb amputation. This was identified that transfemoral amputees have a greater external knee adduction moment than ablebodied subjects by biomechanical studies. Therefore, they need rehabilitative intervention for prevention and reduction of knee osteoarthritis. The purpose of this study was to determine the effect of lateral wedge insole used in the treatment of knee osteoarthritis. This study was participated in fourteen unilateral transfemoral amputees and we were analyzed the difference gait variables between without lateral wedge insole and with $5^{\circ}$ and $10^{\circ}$ lateral wedge insole during gait. Our results showed that step length ratio was more symmetrical and, hip adduction and ankle inversion angle were more close to normal value, and knee adduction moment was decreased as the wedge angle increases. We proposed that these data would be utilized conservative treatment of knee osteoarthritis in lower limb amputees.

Determining the Position of Supporter to prevent a Overload applied to the Wedge Type Rail Clamp (과부화 방지를 위한 쐐기형 레일클램프의 지지대 위치 설정)

  • Han, Dong-Seop;Han, Geun-Jo;Lee, Seong-Wook
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.294-297
    • /
    • 2006
  • The rail clamp is the device to prevent the crane slips along a rail from the wind blast as well as to locate a container crane in the set position during an operating mode. In this study we conduct the research for determining the proper position of supporter to prevent the overload applied to the rail clamp with respect to the wedge angle in the wedge type rail clamp. The friction force between the jaw pad and the rail to prevent that the crane slips along a rail, when the wind blows, is generated fly the rail-directional wind load. Accordingly the proper position of the supporter to prevent the overload is determined fly analyzing the forces applied to the rail clamp in the wedge working stage. In order to analyze the effect of the wedge angle on the position of supporter, 5-kinds of wedge angles, such as 2, 4, 6, 8, $10^{\circ}$, were adapted as the design parameter, and the wind speed of 40m/s was adapted as the design wind speed criteria.

  • PDF

Image-based Approach for Surgical Resection of Gastric Submucosal Tumors

  • Kim, Yoo-Min;Lim, Joon-Seok;Kim, Jie-Hyun;Hyung, Woo-Jin;Noh, Sung-Hoon
    • Journal of Gastric Cancer
    • /
    • v.10 no.4
    • /
    • pp.188-195
    • /
    • 2010
  • Purpose: This study was done to evaluate the usefulness of preoperative computed tomography (CT) and intraoperative laparoscopic ultrasound to facilitate treatment of gastric submucosal tumors. Materials and Methods: The feasibility of laparoscopic wedge resection as determined by CT findings of tumor size, location, and growth pattern was correlated with surgical findings in 89 consecutive operations. The role of laparoscopic ultrasound for tumor localization was analyzed. Results: Twenty-three patients were considered unsuitable for laparoscopic wedge resection because of large tumor size (N=13) or involvement of the gastroesophageal junction (N=9) or pyloric channel (N=1). Laparoscopic wedge resection was not attempted in 11 of these patients because of large tumor size. Laparoscopic wedge resection was successfully performed in 65 of 66 (98.5%) patients considered suitable for this procedure. Incorrect interpretation of preoperative CT resulted in a change of surgery type in seven patients (7.9%): incorrect CT diagnosis on gastroesophageal junction involvement (N=6) and on growth pattern (N=1). In 18 patients without an exophytic growth pattern, laparoscopic ultrasound was necessary and successfully localized all lesions. Conclusions: Preoperative CT and laparoscopic ultrasound are useful for surgical planning and tumor localization in laparoscopic wedge resection.

Numerical study of hydrodynamic interaction on a vessel in restricted waterways

  • Lee, Chun-Ki
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • The hydrodynamic interaction between ship and bank can't be neglected when a vessel is app- roached toward the tip of a wedge-shaped bank in restricted waterways, such as in a harbor, near some fixed obstacles, or in a narrow channel. In this paper, the characteristic features of the hydrodynamic interaction acting on a slowly moving vessel in the proximity of a wedge-shaped bank are described and illustrated, and the effects of water depth and the spacing between ship and wedge-shaped bank are summarized and discussed based on the slender body theory. From the theoretical results, it indicated that the hydrodynamic interactions decrease as wedge-shaped bank of angle ${\beta}$ in-creases. For water depth to draft ratio less than about 2.0, the hydrodynamic interactions between ship and bank in-crease sharply as h/d decreases, regardless of the wedge-shaped bank of angle ${\beta}$. Also, for lateral separation more than about 0.2L between ship and wedge-shaped bank, it can be concluded that the bank effects decrease largely as the separation increases.

Dose Evaluation at The Build Up Region Using by Wedge Filter (쐐기필터 사용에 따른 선량증가 영역에서 선량평가)

  • Kim, Yon-Lae;Moon, Seong-Kong;Suh, Tae-Suk;Chung, Jin-Beom;Kim, Jin-Young;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.341-348
    • /
    • 2014
  • Wedge filter could use to increase the dose distribution at the hot dose regions. We evaluated dose discrepancy at surface and build region in the infield and outfield that Metal Wedge (MW) and Enhance Dynamic Wedge (EDW) were interact with photon. In this paper, we used Gafchromic EBT3 film that had excellent spatial resolution, composed the water equivalent materials and changed the optical density without development. The set up conditions of linear accelerator were fixed 6 MV photon, 100 cm SSD, $10{\times}10cm^2$ field size and were irradiated 400 cGy at Dmax. The dose distribution and absorbed dose were evaluated when we compared the open field with $15^{\circ}$, $30^{\circ}$, $45^{\circ}$ metal wedge and enhanced dynamic wedge. A $15^{\circ}$ metal wedge could increase the surface and build up region dose than using a $15^{\circ}$ enhanced dynamic wedge. A $30^{\circ}$ metal wedge could decrease the surface and build up region dose than using a $30^{\circ}$ enhanced dynamic wedge. A $45^{\circ}$ metal wedge could decrease by large deviation the surface and build up region dose than using a $15^{\circ}$ enhanced dynamic wedge. The dose of penumbra region at outfield were increased on the thick side but were decreased on the thin side. It could be decrease the surface dose and build up region dose, if the metal wedge filters were properly used to make a good dose distribution and not closed the distance of surface.