• Title/Summary/Keyword: wedge

Search Result 1,447, Processing Time 0.033 seconds

Dosimetric Characteristics of Dynamic Wedge Technique (Dynamic Wedge의 조직내 방사선량 분포의 특성)

  • Oh Young Taek;Keum Ki Chang;Chu Seong Sil;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.4
    • /
    • pp.323-332
    • /
    • 1996
  • Purpose : The wedge filter is the most commonly used beam modifying device during radiation therapy Recently dynamic wedge technique is available through the computer controlled asymmetric collimator, independent jaw. But dosimetric characteristics of dynamic wedge technique is not well known. Therefore we evaluate dosimetric characteristics of dynamic wedge compared to conventional fixed wedge. Materials and Methods : We evaluated dosimetric characteristics of dynamic wedge and fixed wedge by ion chamber, film dosimetry and TLD in phantoms such as water, polystyrene and average breast phantom. Six MV x-ray was used in $15{\times}15cm$ field with 15,30 and 45 degree wedge of dynamic/liked wedge system, Dosimeric characteristics are interpreted by Wellhofer Dosimetrie system WP700/WP700i and contralateral breast dose (CBD) with tangential technique was confirmed by TLD. Results : 1) Percent depth dose through the dynamic wedge technique in tissue equivalent phantom was similar to open field irradiation and there was no beam hardening effect compared to fixed wedge technique. 2) Isodose line composing wedge angle of dynamic wedge is more straight than hard wedge. And dynamic wedge technique was able to make any wedge angle on any depth and field size. 3) The contralateral breast dose in primary breast irradiation was reduced by dynamic wedge technique compared to fixed wedge. When the dynamic wedge technique was applied, the scatter dose was similar to that of open field irradiation. Conclusion : The dynamic wedge technique was superior to fixed wedge technique in dosimetric characteristics and may be more useful in the future.

  • PDF

DYNAMIC WEDGE의 임상 적용 가능성에 관한 고찰

  • 김영범;정세영;황웅구
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.7 no.1
    • /
    • pp.103-110
    • /
    • 1995
  • Dynamic wedge system has been introduced to modify the beam profile and to make homogeneous isodose curves in the mass of irregular shape. Before the clinical use of dynamic wedge, several factors such as wedge transmission factor, dose profile, percent depth dose, and wedge angle have to be measured quantitatively. Film dosimetry is used to evaluate these factors in this study. A comparison of the result of the dynamic wedge to physical wedge system is made. A positive result for the application of the dynamic wedge to clinic is derived even though there is a limitation in accuracy of the dosimetry system used. To measure all factors quantitatively, more accurate dosimetry systems are required.

  • PDF

Comparison of Wedge Factors of Dynamic Wedge and Physical Wedge (기능상쐐기와 물질쐐기의 쐐기인수의 비교)

  • Kim Jae Sung;Kang Wee-Saing
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.237-246
    • /
    • 2004
  • Even though the wedge factor was defined by ICRU, RTPS uses other definition different from the wedge factor to consider the wedge effect to correct dose. Because the factors with different concept are defined in a very different way, replacement of different factor could make severe error of dose and is unacceptable because their values are very different from each other. Radiotherapy machine installed in department includes physical wedges and function of dynamic wedge by upper jaws, and Eclipse and Pinnacle$^{3}$ such as RTPS are used. The wedge factors, relative wedge output factors and wedge field output factors of physical wedges and dynamic wedges were measured by an ionization chamber in water phantom. They are analyzed and compared in according to wedge position, field size, wedge angle, X-ray quality, measurement condition. Wedge factor, relative wedge output factors and wedge field output factors of dynamic wedges comparing physical wedges have an effect of several factors. Main factors effecting to the factors of dynamic wedges were field size and wedge angle. Beam quality of X-ray introduces a few effect to the factors. Because the factors related to wedge and defined with different concepts are different from each other, to reduce dose error it should be input by values proper to RTPS.

  • PDF

Effects of Combined Wedge on Angle and Moment of Ankle and Knee Joint During Gait in Patients With Genu Varus

  • Yang, Hae Sun;Choi, Houng Sik
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.7 no.2
    • /
    • pp.1025-1030
    • /
    • 2016
  • The purpose of this study was to investigate the effects of combined wedge on the range of motion in ankle and knee joint, ankle eversion moment and knee adduction moment, and center of pressure excursion of foot for genu varus among adult men during gait. This study was carried out with 10 adult men for genu varus in a motion analysis laboratory in J university. The subjects of the experiment were measured above 5cm width between the knees on contact of both medial malleolus of ankle while standing. The width of their knees in neutral position was measured without the inversion or eversion of the subtalar joint by the investigator. The subjects of the experiment were ten who were conducted randomly for standard insole, insole with $10^{\circ}$ lateral on rear foot wedge, insole at $10^{\circ}$lateral on rear foot and $5^{\circ}$ medial on fore foot wedge. Before and after intervention, changes on the range of motion in ankle and knee joint, ankle eversion moment and knee adduction moment, and center of pressure excursion were measured. In order to compare analyses among groups; repeated one-way ANOVA and $Scheff{\acute{e}}$ post hoc test were used. As a result, combined wedge group was significantly decreased compared to control wedge group in terms of knee varus angle in mid-stance(p<.05). Combined wedge group was significantly decreased compared to lateral wedge group in terms of ankle eversion moment in whole stance(p<.05). Combined wedge group was significantly decreased compared to lateral wedge group in terms of knee adduction moment in whole stance(p<.05). Combined wedge group was significantly decreased compared to lateral wedge in terms of center of pressure excursion in whole stance(p<.05). The results of this study suggest that combined wedge for genu varus decreased ankle eversion moment and knee adduction moment upon center of pressure excursion. We hypothesize that combined wedge may also be effective in the protection excessive ankle pronation.

Shape Design of the U-Type Wedge of the Rail Clamp for a Container Crane (컨테이너 크레인용 레일클램프의 U형 쐐기 형상설계)

  • Han, D.S.;Han, G.J.
    • Journal of Power System Engineering
    • /
    • v.13 no.6
    • /
    • pp.117-122
    • /
    • 2009
  • The wedge type rail clamp compresses the rails with small clamping force at first, and with large clamping force when the wind speed increases because of the wedge working. If the supporter is not installed in the rail clamp with V-type wedge when the wind speed increases more and more, the structure will occur overload which leads the structure to fracture. But in the clamp with U-type wedge the supporter is not necessary because the tangential angle of the wedge increases as the sliding distance increases. The proper shape of U-type wedge is determined by the initial clamping force and the tangential angle of the wedge. Accordingly we, first carry out the finite element analysis in order to analyze the relation between the sliding distance and the wedge angle. Next we suggest the proper shape of U-type wedge as analyze the relation between the radius of curvature and the sliding distance.

  • PDF

Study on the Wedge Angle of Wedge Type Rail Clamp for Container Crane (컨테이너 크레인용 쐐기형 레일 클램프의 쐐기각에 대한연구)

  • Han, Geun-Jo;Lee, Ho;Sim, Jae-Jun;Han, Dong-Sub;An, Chan-Woo;Jeon, Young-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.9
    • /
    • pp.119-126
    • /
    • 2004
  • In this paper, we design a wedge type rail clamp which can protect container crane from a sudden strong blast with constant clamping force regardless of the operating period. When we design wedge type rail clamp, it is important to determine the angle of wedge and analyze a contact condition of roller and wedge so that we might develop a wedge type rail clamp for parking devices of port cargo working system with variable capacity. Therefore, this paper suggests a process to decide wedge angles within feasible range which could be obtained using load analysis and FEA of wedge type rail clamp

Clinical Application of Wedge Factor (Wedge Factor의 임상적 응용)

  • Choi Dong-Rak;Ahn Yong-Chan;Huh Seung Jae
    • Radiation Oncology Journal
    • /
    • v.13 no.3
    • /
    • pp.291-296
    • /
    • 1995
  • Purpose : In general, the wedge factors which are used clinical practices are ignored of dependency on field sizes and depths. In this present, we investigated systematically the depth and field size dependency to determine the absorbed dose more accurately. Methods : The wedge factors for each wedge filter were measured at various depths (depth of Dmax, 5cm, 10cm, and 15cm) and field sizes ($5cm{\times}5cm,\;10cm{\times}10cm,\;15cm{\times}15cm, and 20cm{\times}20cm$) by using 4-, 6-, and 10-MVX rays. By convention, wedge factors are determined by taking the ratio of the central axis ionization readings when the wedge filter is in place to those of the open field in same field size and measurement depth. In this present work, we determined the wedge factors for 4-, 6-, and 10-MV X rays from Clinac 600C and 2100C linear accelerators (manufactured by Varian Associates, Inc., Palo Alto, CA). To confirm that the wedge was centered, measurements were done with the two possible wedge position and various collimator orientations. Results : The standard deviations of measured values are within $0.3\;\%$ and the depth dependence of wedge factor is greater for the lower energies. Especially, the variation of wedge factor is no less than $5\%$ for 4- and 6- MV X rays with more than $45^{\circ}$ wedge filters. But there seems to be a small dependence on field size. Conclusion : The results of this study show a dependence on the point of measurement. There also seems to be a small dependence on field size. And so, we should consider the depth and field size dependence in determining the wedge factors. If one wedge factor were to be used for each wedge filter it seems that the measurement for a 10cm x 10cm field size at a depth of loom would be a reasonable choice.

  • PDF

E-polarized electromagnetic diffraction by a composite wedge, II:Extended diffraction coefficients (도체와 유전체가 복합된 쐐기에 의한 E-편파된 전자파의 회절, II:확장된 회절계수)

  • 김세윤;김상욱
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.7
    • /
    • pp.1-7
    • /
    • 1997
  • The physical optical solution to the E-polarized diffraction by a composite wedge consisting of perfect conductor and lossless dielectric cannot sayisfy not only the boundary conditions at the wedge interfaces but also the edge condition at the wedge tip. Its diffraction coefficients are extended outside the composite wedge to become the exact solution to the perfectly conducting wedge as its relative dielectric constant increases to infinite or decreases to 1. It is assured that the extended diffraction coefficients approach zero in the arificially complementary region of the composite wedge.

  • PDF

Physical Characteristics Comparison of Virtual Wedge Device with Physical Wedge (가상쐐기와 기존쐐기의 물리적 특성 비교)

  • Cho, Jung-Keun;Choi, Kye-Sook;Lim, Cheong-Hwan;Kim, Jeong-Koo;Jung, Hong-Ryang;Lee, Jung-Ok;Lee, Man-Goo
    • Journal of radiological science and technology
    • /
    • v.24 no.2
    • /
    • pp.49-52
    • /
    • 2001
  • We compared the characteristics of Siemens virtual wedge device with physical wedges for clinical application. We investigated the characteristics of virtual and physical wedges for various wedge angles (15, 30, 45, and 60) using 6- and 15-MV photon beams. Wedge factors were measured in water using an ion chamber for various field sizes and depths. In case of virtual wedge device, as upper jaw moves during irradiation, wedge angles were estimated by accumulated doses. These measurements were performed at off-axis points perpendicular to the beam central axis in water for a $15\;cm\;{\times}\;20\;cm$ radiation field size at the depth of 10 cm. Surface doses without and with virtual or physical wedges were measured using a parallel plate ion chamber at surface. Field size was $15\;cm\;{\times}\;20\;cm$ and a polystyrene phantom was used. For various field sizes, virtual and physical wedge factors were changed by maximum 2.1% and 3.9%, respectively. For various depths, virtual and physical wedge factors were changed by maximum 1.9% and 2.9%, respectively. No major difference was found between the virtual and physical wedge angles and the difference was within 0.5. Surface dose with physical wedge was reduced by maximum 20% (x-ray beam : 6 MV, wedge angle : 45, SSD : 80 cm) relative to one with virtual wedge or without wedge. Comparison of the characteristics of Siemens virtual wedge device with physical wedges was performed. Depth dependence of virtual wedge factor was smaller than that of physical wedge factor. Virtual and physical wedge factors were nearly independent of field sizes. The accuracy of virtual and physical wedge angles was excellent. Surface dose was found to be reduced using a physical wedge.

  • PDF

MINIMAL BASICALLY DISCONNECTED COVERS OF PRODUCT SPACES

  • Kim Chang-Il
    • Communications of the Korean Mathematical Society
    • /
    • v.21 no.2
    • /
    • pp.347-353
    • /
    • 2006
  • In this paper, we show that if the minimal basically disconnected cover ${\wedge}X_\imath\;of\;X_\imath$ is given by the space of fixed a $Z(X)^#$-ultrafilters on $X_\imath\;(\imath=1,2)\;and\;{\wedge}X_1\;{\times}\;{\wedge}X_2$ is a basically disconnected space, then ${\wedge}X_1\;{\times}\;{\wedge}X_2$ is the minimal basically disconnected cover of $X_1\;{\times}\;X_2$. Moreover, observing that the product space of a P-space and a countably locally weakly Lindelof basically disconnected space is basically disconnected, we show that if X is a weakly Lindelof almost P-space and Y is a countably locally weakly Lindelof space, then (${\wedge}X\;{\times}\;{\wedge}Y,\;{\wedge}_X\;{\times}\;{\wedge}_Y$) is the minimal basically disconnected cover of $X\;{\times}\;Y$.