• Title/Summary/Keyword: weathered zone

Search Result 123, Processing Time 0.022 seconds

Application of Geotechnical Properties to the Slope Stability Analysis in Deep Weathered Zone (깊은 풍화대 사면의 안정성 해석에서 물성치 산정 및 적용)

  • Kim, Kyung-Tae;Park, See-Boum;Kim, Chang-Hyun;Lee, Jong-Bum;Yoon, Yea-Won
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.768-776
    • /
    • 2006
  • Recently in spite of Development of Investigation machine, in Application of Geotechnical Properties by empirical recommendation to the Slope Stability Analysis. It is generally Application of convenience and conservative Geotechnical Properties by Borehole Shear Test(BST) in Representative Zone that Non-Division of Increase as the depth of Strength Parameters In Deep Weathered Zone. Therefore, it is become environment pollution and Non-Economical Slope Design to Application of convenience and conservative Geotechnical Properties. The production mechanism of Deep Weathered Zone is tend to Weathering Degree low and Strength increase by increase as the depth. it is realistic design that Division of Deep Weathered Zone and application Geotechnical Properties of Each Layer. In this Paper, Determined The Relationship of Strength Parameters between Standard Penetration Test(SPT), Borehole Shear Test(BST) and empirical recommendation also Applyed each strength parameters of divided zone to the Slope Stability Analysis by continuous Borehole Shear Test(BST) in Deep Weathered Zone during design of The 2nd Bridge Connection Road of Incheon International Airport.

  • PDF

Case Study of Correlation between the SPT-N Value and PMT Results Performed on Weathered Granite Zone in Korea (국내 화강 풍화대 지반의 표준관입시험 N 값과 프레셔미터시험 결과의 상관관계에 대한 사례 분석)

  • Lee, Seung-Hwan;Baek, Sung-Ha;Song, Young-Woo;Chung, Choong-Ki
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.12
    • /
    • pp.15-24
    • /
    • 2019
  • Weathered granite zone exists in most regions of Korea and it is often used as a bearing stratum of geotechnical structures. So it is very important to estimate the characteristics of weathered granite zone. SPT (Standard penetration test) is usually performed to investigate the characteristics of the weathered zone because undisturbed samples suitable for laboratory testing are hardly retrieved. PMT (Pressuremeter test) can reliably evaluate the in situ stress-strain behavior, but it is rarely conducted because of their high cost and time-consuming procedure. In this study, the correlation between the SPT-N values and the PMT results, obtained from the weathered granite zone, was analyzed. Empirical equations for pressuremeter modulus (Em) and limit pressure (PL) were suggested and compared with the previous research.

Surface Geophysical Survey for Delineation of Weathered Zone of Chojeong Area and Investigation of Fault Fracture Zones (초정지역의 풍화대 조사 및 단층파쇄 지역의 불연속면 조사를 위한 지표물리탐사)

  • Kim, Ji-Soo;Han, Soo-Hyung
    • The Journal of Engineering Geology
    • /
    • v.17 no.4
    • /
    • pp.517-523
    • /
    • 2007
  • Geophysical surveys(seismic refraction, electrical resistivity, and ground penetrating radar) were performed to delineate the weathering zone associated with vadose water in Chojeong area and investigate the fault related fracture zones. On the basis of seismic velocity structures, weathering layer for the southwestern part is interpreted to be deeper than for the northeastern part. The depth to bedrock(i.e., thickness of weathered zone) from seismic refraction data attempted to be correlated with drill-core data and groundwater level. As for the investigation of geological discontinuities such as fault related fracture zone, seismic refraction, electrical resistivity, and ground penetrating data are compositely employed in terms of velocity and resistivity structures for mapping of surface boundary of the discontinuities up to shallow depth. Surface boundaries of fracture zone are well indicated in seismic velocity and electrical resistivity structures. Accurate estimation of weathered zone and fracture zone can be successfully available for mapping of attitude of vadose water layer.

Effect of interference and Ground Movement by Twin Tunnelling (쌍굴터널 굴진에 따른 주변지반의 거동과 간섭효과)

  • 김학문
    • Tunnel and Underground Space
    • /
    • v.7 no.2
    • /
    • pp.136-142
    • /
    • 1997
  • The behaviour of ground movement during the construction of two parallel tunnels in weathered zone and soft rock has been investigated. All the influencing factors for the behaviour of twin tunnel such as tunnel size, ground conditions, tunnel depth, pillar width and initial state of ground stresses were examined The results of FEM nonlinear analysis were compared with some of model test results in weathered zone to verify the numerical method. It was found that minimum interference was obtained in the parallel construction case when the twin tunnel distance (pillar width) is just over the twice of tunnel diameter. Guide line for the interference of twin tunnelling has been introduced for the ground of weathered zone and soft rock.

  • PDF

Analysis of Weathered State on a Halo Stone Buddha, Unju Temple of Hwasun, Korea Using Low Frequency Flaw Detector (저주파 결함 탐지기를 활용한 화순 운주사 광배석불의 풍화상태 분석)

  • Kang, Seong-Seung;Ko, Chin-Surk;Kim, Cheong-Bin;Jang, Bo-An
    • The Journal of Engineering Geology
    • /
    • v.23 no.3
    • /
    • pp.235-246
    • /
    • 2013
  • P-wave velocity was measured by the low frequency flaw detector in order to analyze the weathered state of a halo stone Buddha, Unju temple, Hwasun, Korea. By the results of laboratory tests on a fresh acidic tuff with the same rock of a halo stone Buddha, average absorption, average P-wave velocity, and average uniaxial compressive strength were 5.38%, 4,008 m/s, and 70.1 MPa, respectively. The results correspond to moderately strong rock. Average P-wave velocity of a halo stone Buddha measured by the low frequency flaw detector was 2,257 m/s in the left zone, 3,437 m/s in the right zone, and 2,802 m/s overall. Weathering index of a halo stone Buddha was 0.45 in the left zone, 0.21 in the right zone, and 0.33 overall. Comparing the results of a halo stone Buddha with them of laboratory tests, weathered state of a halo stone Buddha was analyzed highly weathered state in the left zone and moderately weathered state in the right zone. Furthermore, it suggests that the left zone of a halo stone Buddha was affected weathering more than the right one. Overall a halo stone Buddha corresponds to moderately weathered state of weathering degrees. In conclusion, it is considered that low frequency flaw detector may be applicable as a valuable method on analyzing the P-wave velocity of the stone cultural heritage with an irregular surface.

A Development and utilization of Geotechnical Information System(GTIS) of the Rock Mass in Seoul Metropolitan Area(2) (서울일대 암반을 대상으로 한 Geotechnical Information System (GTIS)의 개발 및 활용 (2))

  • 김정엽;박형동
    • Tunnel and Underground Space
    • /
    • v.6 no.3
    • /
    • pp.223-233
    • /
    • 1996
  • Geotechnical Information System (GTIS) for efficient management of three dimensional borehole data has been developed. Geotechnical maps in the vicinity of Bulkwangdong, Seoul station, Itaewon, Han river near Yuido, and Jungrangchon were constructed by Kriging method. In Bulkwangdong and Jungrangchon area where boundary between granite and gneiss is present, gneiss has been more weathered than granite, but in Seoul station and Itaewon area where the boundary is also present, granite has been more weathered than gneiss. It has been inferred that when Seoul granite intruded, the strength of gneiss in Bulkwangdong and Jungrangchon area was lowered by the attitude of foliation plane than in Seoul station and Itaewon area, so the gneiss has been easily fractured and weathered in Bulkwangdong and Jungrangchon area. Geotechnical map in the vicinity of Yuido showed that there is an NW-SE trend weakness zone that might be affected by major faults under Han river and it is expected that the fault zone may be present in construction area of Kyoungbu Highspeed Railway that lies below the Han river like the Subway Line No.5.

  • PDF

Effect of shear zone on dynamic behaviour of rock tunnel constructed in highly weathered granite

  • Zaid, Mohammad;Sadique, Md. Rehan;Alam, M. Masroor;Samanta, Manojit
    • Geomechanics and Engineering
    • /
    • v.23 no.3
    • /
    • pp.245-259
    • /
    • 2020
  • Tunnels have become an indispensable part of metro cities. Blast resistance design of tunnel has attracted the attention of researchers due to numerous implosion event. Present paper deals with the non-linear finite element analysis of rock tunnel having shear zone subjected to internal blast loading. Abaqus Explicit schemes in finite element has been used for the simulation of internal blast event. Structural discontinuity i.e., shear zone has been assumed passing the tunnel cross-section in the vertical direction and consist of Highly Weathered Granite medium surrounding the tunnel. Mohr-Coulomb constitutive material model has been considered for modelling the Highly Weathered Granite and the shear zone material. Concrete Damage Plasticity (CDP), Johnson-Cook (J-C), Jones-Wilkins-Lee (JWL) equation of state models are used for concrete, steel reinforcement and Trinitrotoluene (TNT) simulation respectively. The Coupled-Eulerian-Lagrangian (CEL) method of modelling for TNT explosive and air inside the tunnel has been adopted in this study. The CEL method incorporates the large deformations for which the traditional finite element analysis cannot be used. Shear zone orientations of 0°, 15°, 30°, 45°, 60°, 75° and 90°, with respect to the tunnel axis are considered to see their effect. It has been concluded that 60° orientation of shear zone presents the most critical situation.

Application Techniques of 2D-Resistivity Structure for Estimation of Inferred Fracture Zone in Weathered Slope (풍화사면에서의 추정파쇄대 평가를 위한 2차원 전기비저항 구조도 적용 기법)

  • Kim, Jae-Hong;Park, Chal-Sook;Lee, Hyun-Jae;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.19 no.3
    • /
    • pp.323-330
    • /
    • 2009
  • Electrical resistivity survey is applied for estimation of inferred fault and fractured zone in civil engineering and environment field. While 15 m diameter and 3 lines tunnels are excavated. It is recognized that core stone and fractured zone is existed in the weathered slope of the entrance to a tunnel. To make confirmation geological characteristics, dipole-dipole electric resistivity survey was carried out in weathered slope of the entrance to a tunnel. Core stone distribution and fracture zone characteristics are estimated by reverse analysis and 2D-resistivity structure using FDM.

The influence of tunnelling on the behaviour of pre-existing piled foundations in weathered soil

  • Lee, Cheol-Ju;Jeon, Young-Jin;Kim, Sung-Hee;Park, Inn-Joon
    • Geomechanics and Engineering
    • /
    • v.11 no.4
    • /
    • pp.553-570
    • /
    • 2016
  • A series of three-dimensional (3D) parametric finite element analyses have been performed to study the influence of the relative locations of pile tips with regards to the tunnel position on the behaviour of single piles and pile groups to adjacent tunnelling in weathered soil. When the pile tips are inside the influence zone, which considers the relative pile tip location with respect to the tunnel position, tunnelling-induced pile head settlements are larger than those computed from the Greenfield condition. However, when the pile tips are outside the influence zone, a reverse trend is obtained. When the pile tips are inside the influence zone, the tunnelling-induced tensile pile forces mobilised, but when the pile tips are outside the influence zone, compressive pile forces are induced because of tunnelling, depending on the shear stress transfer mechanism at the pile-soil interface. For piles connected to a cap, tensile and compressive forces are mobilised at the top of the centre and side piles, respectively. It has been shown that the increases in the tunnelling-induced pile head settlements have resulted in reductions of the apparent factor of safety up to approximately 43% when the pile tips are inside the influence zone, therefore severely affecting the serviceability of the piles. The pile behaviour, when considering the location of the pile tips with regards to the tunnel, has been analysed in great detail by taking the tunnelling-induced pile head settlements, axial pile forces, apparent factor of safety of the piles and shear transfer mechanism into account.

A Study on the Development of Design Chart for Drilled Shaft Socketed into Weathered Zone Using DCPT (Driving Cone Penetrometer Test) (DCPT를 이용한 풍화대 소켓 현장타설말뚝의 설계도표 개발에 관한 연구)

  • Jung, Sung-Min;Kwon, Oh-Sung;Lee, Jong-Sung;Lee, Min-Hee;Choi, Yong-Kyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.5
    • /
    • pp.5-13
    • /
    • 2010
  • For the development of design chart for drilled shafts socketed into weathered zone, the 6 bi-directional pile load tests with load transfer measurements done in two in-situ sites were performed. Also, DCPTs were performed in each test point. Maximum unit skin frictions and maximum unit end bearing capacities from pile load test results were analyzed. Inter-relationships between DCPT's characteristics were also analyzed. In the soils, the inter-relationships of maximum unit skin friction and DCPT appeared so low. But in the weathered zones, inter-relationships between maximum unit skin friction / maximum unit end bearing capacity and DCPT were so high that the coefficient of correlation is over 0.70.