• 제목/요약/키워드: weathered zone

검색결과 123건 처리시간 0.069초

깊은 풍화대 사면의 안정성 해석에서 물성치 산정 및 적용 (Application of Geotechnical Properties to the Slope Stability Analysis in Deep Weathered Zone)

  • 김경태;박시범;김창현;이종범;윤여원
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.768-776
    • /
    • 2006
  • Recently in spite of Development of Investigation machine, in Application of Geotechnical Properties by empirical recommendation to the Slope Stability Analysis. It is generally Application of convenience and conservative Geotechnical Properties by Borehole Shear Test(BST) in Representative Zone that Non-Division of Increase as the depth of Strength Parameters In Deep Weathered Zone. Therefore, it is become environment pollution and Non-Economical Slope Design to Application of convenience and conservative Geotechnical Properties. The production mechanism of Deep Weathered Zone is tend to Weathering Degree low and Strength increase by increase as the depth. it is realistic design that Division of Deep Weathered Zone and application Geotechnical Properties of Each Layer. In this Paper, Determined The Relationship of Strength Parameters between Standard Penetration Test(SPT), Borehole Shear Test(BST) and empirical recommendation also Applyed each strength parameters of divided zone to the Slope Stability Analysis by continuous Borehole Shear Test(BST) in Deep Weathered Zone during design of The 2nd Bridge Connection Road of Incheon International Airport.

  • PDF

국내 화강 풍화대 지반의 표준관입시험 N 값과 프레셔미터시험 결과의 상관관계에 대한 사례 분석 (Case Study of Correlation between the SPT-N Value and PMT Results Performed on Weathered Granite Zone in Korea)

  • 이승환;백성하;송영우;정충기
    • 한국지반공학회논문집
    • /
    • 제35권12호
    • /
    • pp.15-24
    • /
    • 2019
  • 국내 다수의 지역에 분포하는 화강 풍화대 지반은 지반구조물의 주요 지지층으로 활용되고 있으므로 화강 풍화대의 지반특성을 평가하는 것은 중요하다. 풍화대 지반은 실내시험을 위한 불교란 시료를 채취하는 것이 어렵기 때문에 일반적으로 표준관입시험(SPT: Standard penetration test)을 통해 지반특성을 평가하고 있다. 프레셔미터시험(PMT: Pressuremeter test)은 풍화대 지반의 응력 - 변형률 거동을 신뢰도 높게 평가하는 대표적인 현장시험이지만 소요 시간과 비용의 제약으로 제한적인 시험만을 수행하고 있다. 본 연구에서는 화강 풍화대에서 수행된 SPT-N60 값과 PMT 결과의 상관성 분석을 수행하였으며, N60 - Em(Em: Pressuremeter modulus)과 N60 - PL(PL: Limit pressure) 관계식을 제안하였고 선행 연구 결과와 비교 분석하였다.

초정지역의 풍화대 조사 및 단층파쇄 지역의 불연속면 조사를 위한 지표물리탐사 (Surface Geophysical Survey for Delineation of Weathered Zone of Chojeong Area and Investigation of Fault Fracture Zones)

  • 김지수;한수형
    • 지질공학
    • /
    • 제17권4호
    • /
    • pp.517-523
    • /
    • 2007
  • 이 연구에서는 초정지역의 충적층 지하수와 관련된 풍화대분포를 파악하고 단층파쇄대 조사를 위해 복합물리탐사(탄성파굴절법, 전기비저항, 지하투과레이더탐사)를 수행하였다. 탄성파속도 정보로부터 풍화대는 대상지역의 남서부로 갈수록 깊어지는 것으로 나타나는데 기반암까지의 심도 즉 풍화대의 두께는 또한 기존의 시추자료 및 지하수위 자료와 거의 일치한다. 소규모 단층과 관련된 파쇄대 조사에서는 탄성파굴절법, 전기비저항, 레이더탐사 자료를 속도와 비저항 구조를 복합적으로 천부까지 해석하여 단층파쇄대의 지표 경계등을 파악하였다. 복합 지구물리탐사로 정확히 제시된 풍화대와 파쇄대 등에 대한 정보는 충적층 지하수의 분포를 알아내는데 충분히 활용될 수 있을 것으로 보인다.

쌍굴터널 굴진에 따른 주변지반의 거동과 간섭효과 (Effect of interference and Ground Movement by Twin Tunnelling)

  • 김학문
    • 터널과지하공간
    • /
    • 제7권2호
    • /
    • pp.136-142
    • /
    • 1997
  • The behaviour of ground movement during the construction of two parallel tunnels in weathered zone and soft rock has been investigated. All the influencing factors for the behaviour of twin tunnel such as tunnel size, ground conditions, tunnel depth, pillar width and initial state of ground stresses were examined The results of FEM nonlinear analysis were compared with some of model test results in weathered zone to verify the numerical method. It was found that minimum interference was obtained in the parallel construction case when the twin tunnel distance (pillar width) is just over the twice of tunnel diameter. Guide line for the interference of twin tunnelling has been introduced for the ground of weathered zone and soft rock.

  • PDF

저주파 결함 탐지기를 활용한 화순 운주사 광배석불의 풍화상태 분석 (Analysis of Weathered State on a Halo Stone Buddha, Unju Temple of Hwasun, Korea Using Low Frequency Flaw Detector)

  • 강성승;고진석;김정빈;장보안
    • 지질공학
    • /
    • 제23권3호
    • /
    • pp.235-246
    • /
    • 2013
  • 화순 운주사 내 광배석불에 대한 풍화상태를 분석하기 위하여 저주파 결함 탐지기를 활용하여 종파속도를 측정하였다. 석불과 같은 암종인 신선한 산성응회암의 실내시험 결과 평균흡수율은 5.38%, 평균종파속도는 4,008 m/s, 평균일축압축강도는 70.1 MPa로서 보통암에 해당되었다. 저주파 결함 탐지기에 의해 측정된 석불의 평균종파속도는 왼쪽 영역이 2,257 m/s, 오른쪽 영역이 3,347 m/s이며, 석불 전체영역의 평균종파속도는 2,802 m/s로 나타났다. 대상 석불에 대한 풍화지수 계산 결과, 평균풍화지수는 왼쪽 영역이 0.45, 오른쪽 영역이 0.21이었고, 석불 전체의 풍화지수는 0.33으로 나타났다. 석불의 결과를 실내시험 결과와 비교해 볼 때, 석불의 풍화상태는 왼편이 상당한 풍화, 오른편이 보통풍화로 분석되며, 더군다나 석불의 왼쪽 영역이 오른쪽 영역보다 더 많은 풍화작용을 받았음을 지시한다. 전체적으로 대상 석불은 풍화등급분류 중 보통풍화상태에 해당된 것으로 판단된다. 결론적으로, 표면상태가 고르지 못한 석조문화재의 종파속도 분석에 있어서 저주파 결함 탐지기가 유용하게 적용될 수 있을 것으로 기대된다.

서울일대 암반을 대상으로 한 Geotechnical Information System (GTIS)의 개발 및 활용 (2) (A Development and utilization of Geotechnical Information System(GTIS) of the Rock Mass in Seoul Metropolitan Area(2))

  • 김정엽;박형동
    • 터널과지하공간
    • /
    • 제6권3호
    • /
    • pp.223-233
    • /
    • 1996
  • Geotechnical Information System (GTIS) for efficient management of three dimensional borehole data has been developed. Geotechnical maps in the vicinity of Bulkwangdong, Seoul station, Itaewon, Han river near Yuido, and Jungrangchon were constructed by Kriging method. In Bulkwangdong and Jungrangchon area where boundary between granite and gneiss is present, gneiss has been more weathered than granite, but in Seoul station and Itaewon area where the boundary is also present, granite has been more weathered than gneiss. It has been inferred that when Seoul granite intruded, the strength of gneiss in Bulkwangdong and Jungrangchon area was lowered by the attitude of foliation plane than in Seoul station and Itaewon area, so the gneiss has been easily fractured and weathered in Bulkwangdong and Jungrangchon area. Geotechnical map in the vicinity of Yuido showed that there is an NW-SE trend weakness zone that might be affected by major faults under Han river and it is expected that the fault zone may be present in construction area of Kyoungbu Highspeed Railway that lies below the Han river like the Subway Line No.5.

  • PDF

Effect of shear zone on dynamic behaviour of rock tunnel constructed in highly weathered granite

  • Zaid, Mohammad;Sadique, Md. Rehan;Alam, M. Masroor;Samanta, Manojit
    • Geomechanics and Engineering
    • /
    • 제23권3호
    • /
    • pp.245-259
    • /
    • 2020
  • Tunnels have become an indispensable part of metro cities. Blast resistance design of tunnel has attracted the attention of researchers due to numerous implosion event. Present paper deals with the non-linear finite element analysis of rock tunnel having shear zone subjected to internal blast loading. Abaqus Explicit schemes in finite element has been used for the simulation of internal blast event. Structural discontinuity i.e., shear zone has been assumed passing the tunnel cross-section in the vertical direction and consist of Highly Weathered Granite medium surrounding the tunnel. Mohr-Coulomb constitutive material model has been considered for modelling the Highly Weathered Granite and the shear zone material. Concrete Damage Plasticity (CDP), Johnson-Cook (J-C), Jones-Wilkins-Lee (JWL) equation of state models are used for concrete, steel reinforcement and Trinitrotoluene (TNT) simulation respectively. The Coupled-Eulerian-Lagrangian (CEL) method of modelling for TNT explosive and air inside the tunnel has been adopted in this study. The CEL method incorporates the large deformations for which the traditional finite element analysis cannot be used. Shear zone orientations of 0°, 15°, 30°, 45°, 60°, 75° and 90°, with respect to the tunnel axis are considered to see their effect. It has been concluded that 60° orientation of shear zone presents the most critical situation.

풍화사면에서의 추정파쇄대 평가를 위한 2차원 전기비저항 구조도 적용 기법 (Application Techniques of 2D-Resistivity Structure for Estimation of Inferred Fracture Zone in Weathered Slope)

  • 김재홍;박철숙;이현재;정교철
    • 지질공학
    • /
    • 제19권3호
    • /
    • pp.323-330
    • /
    • 2009
  • 전기비저항 탐사는 최근 토목설계 및 환경분야에 있어서 단층 및 파쇄대의 탐지 등에 활발히 적용되고 있다. 국내에서는 지금까지 시공실적이 없는 직경 15 m 3열의 터널 굴착공사를 시행하는 도중 터널 유입부 지반이 당초 설계와 달리 기반암선이 낮게 형성되었고, 풍화된 사면에 핵석과 파쇄대가 존재하는 것으로 나타났다. 터널 유입부 지반의 분포양상을 정확히 파악하고자 전기비저항 쌍극자탐사를 시행하였다. 전기비저항 탐사는 암석의 종류, 공극, 온도 및 지질적 순환과정 등을 통하여 외견비저항 값이 많은 변화를 보인다. 역산해석 후 전기비저항치에 의한 지반특성을 파악하였고 유한차분법을 활용한 2차원 전기비저항 구조도를 적용하여 파쇄대를 추정하였다.

The influence of tunnelling on the behaviour of pre-existing piled foundations in weathered soil

  • Lee, Cheol-Ju;Jeon, Young-Jin;Kim, Sung-Hee;Park, Inn-Joon
    • Geomechanics and Engineering
    • /
    • 제11권4호
    • /
    • pp.553-570
    • /
    • 2016
  • A series of three-dimensional (3D) parametric finite element analyses have been performed to study the influence of the relative locations of pile tips with regards to the tunnel position on the behaviour of single piles and pile groups to adjacent tunnelling in weathered soil. When the pile tips are inside the influence zone, which considers the relative pile tip location with respect to the tunnel position, tunnelling-induced pile head settlements are larger than those computed from the Greenfield condition. However, when the pile tips are outside the influence zone, a reverse trend is obtained. When the pile tips are inside the influence zone, the tunnelling-induced tensile pile forces mobilised, but when the pile tips are outside the influence zone, compressive pile forces are induced because of tunnelling, depending on the shear stress transfer mechanism at the pile-soil interface. For piles connected to a cap, tensile and compressive forces are mobilised at the top of the centre and side piles, respectively. It has been shown that the increases in the tunnelling-induced pile head settlements have resulted in reductions of the apparent factor of safety up to approximately 43% when the pile tips are inside the influence zone, therefore severely affecting the serviceability of the piles. The pile behaviour, when considering the location of the pile tips with regards to the tunnel, has been analysed in great detail by taking the tunnelling-induced pile head settlements, axial pile forces, apparent factor of safety of the piles and shear transfer mechanism into account.

DCPT를 이용한 풍화대 소켓 현장타설말뚝의 설계도표 개발에 관한 연구 (A Study on the Development of Design Chart for Drilled Shaft Socketed into Weathered Zone Using DCPT (Driving Cone Penetrometer Test))

  • 정성민;권오성;이종성;이민희;최용규
    • 한국지반공학회논문집
    • /
    • 제26권5호
    • /
    • pp.5-13
    • /
    • 2010
  • 국내 풍화대 지반에 적용가능한 설계도표를 작성하기 위하여 2개소 현장에서 총 6개의 양방향고유양말뚝재하시험 및 하중전이시험을 수행하였으며, 또한 각각 위치에서는 한국형타격콘관입시험 (DCPT)을 수행하였다. 말뚝재하시혐의 결과로부터 심도별 최대단위선단지지력올 분석하였으며 DCPT 결과를 이용하여 이들의 상관성을 분석하였다. 토사(사질토, 점토)지반에서는 최대단위주변마찰력과 DCPT의 상관성이 매우 낮게 나타났으나 풍화대지반에서는 최대단위주변마찰력 / 최대단위선단지지력과 DCPT의 관계에서는 상관계수가 0.70이상으로 높게 나타났다.