To investigate the seasonal effects on physiological responses of human body, clothing micro-climate, and subjective sensation, selected the cloths the most frequently dressed by men in spring and fall, and completed wearing trials in the climatic chamber. The results are as follows: 1. Rectal temp. ranged 36.8-37.1$^{\circ}C$ in either spring or fall, and no seasonal effect was found. 2. In skin temp., there was no seasonal effect in forehead, abdomen, and forearm. Skin temp. of chest was higher in spring than in fall. On the contrary, reverse was true in high and leg. Average skin temp. ranged 32.2-33.2$^{\circ}C$ in spring and 32.9-34.$0^{\circ}C$ in fall. 3. Average total sweat rate of spring, 79.4g/hr, was smaller than that of fall, 110.9g/hr. 4. Clothing temp. ranged 28.1-32.8$^{\circ}C$ in spring and 27.6-31.$0^{\circ}C$ in fall. Clothing humidity ranged 36.9-48.9% in spring and 38.2-51.1% in fall. Therefore, clothing microclimate was higher during fall than during spring. As results, skin temp. of the body core except chest did not show seasonal variation, but there was obvious seasonal variation in skin temp. of the extremities. Therefore, seasonal variation should be take into consideration in the experiments related to the cloth. In addition, standard for each season and the degree of work performance should be re-established in clothing micro-climate.
Journal of the Korean Society of Clothing and Textiles
/
v.31
no.6
s.165
/
pp.955-965
/
2007
Safety helmets are used widely in various industries by workers since they are legally required to wear them. However, thermal discomfort is one of the major complaints from helmet users. To relieve this problem, frozen gelled packs can be considered for use inside the helmets. In this paper, tests were performed on humans to evaluate the physiological strains of wearing safety helmets and to investigate the effects of using frozen gelled packs inside the helmets. Experiments were conducted in a climatic chamber of WBGT $33{\pm}1^{\circ}C$ under four differed experimental conditions: 1) not wearing a safety helmet(NH); 2) wearing a safety helmet with frozen gelled pack A(HA); 3) wearing a safety helmet with frozen gelled pack B(HB); and 4) wearing only a safety helmet(OH). The results were as follows. First, when comparing NH with OH, physiological responses such as $\bar{T}_{sk},\;T_r$, HR and sweat rate were significantly higher in OH and subjective sensations were reported as less hot and more comfortable than NH(p<.05). Second, in regard to the frozen gelled packs inserted inside the safety helmets, some physiological responses in HA were different from those in HB, according to the two different types of packs. HA was hotter, more uncomfortable and less exhausted than HB. However, result from both HA and HB were lower than those from OH in terms of temperature and humidity inside safety helmet, sweat rate, $T_r$ increase, heat storage(p<.05). When wearing safety helmets with frozen gelled packs, it was shown that heat strain can be alleviated. These results are expected to help millions of workers who complain that wearing safety helmets is uncomfortable and messy.
Journal of the Korean Society of Clothing and Textiles
/
v.28
no.5
/
pp.582-590
/
2004
The purpose of this study was to evaluate thermal properties of Taekwondo wears with three different materials. As a begging step, the questionnaire survey about the actual condition of Taekwondo wears was conducted. With the results of the questionnaire, cotton/nylon(70/30) blended fabric(CN) that was newly woven with sweat absorbent finishing and cotton/spandex(95/5) blended fabric with flexibility property were developed. The same designed 3 Taekwondo wears with 3 different materials which were two different materials(CN and CS) and a current material(cotton/PET, CP) were made. Four young males volunteered for this study, they kicked and punched as Taekwondo action for 20 minutes. Mean skin temperature was the highest in CS(33.1${\pm}$0.8$^{\circ}C$) and the lowest in CP(32.7${\pm}$0.6$^{\circ}C$). Increasing degree of rectal temperature didn't show any significant difference. Clothing microclimate temperature on the thigh was higher in CS(32.8${\pm}$17.4$^{\circ}C$) than in CN(29.4${\pm}$1.1$^{\circ}C$) and CP(29.4${\pm}$1.0$^{\circ}C$). Clothing microclimate temperature on the back and humidity on the thigh didn't show any significant differences. Clothing microclimate humidity on the back was higher in CP(65${\pm}$20%RH) than in CS(61${\pm}$17%RH). Heart rate, total body weight loss, and local sweating were not significantly different by materials. Most subject responded more hot in CN than in others, but there were no significant differences at the subjective sensation of thermal humidity. They answered more comfortable in CN than in others. Tectile sensations were the best in CN and the worst in CS. From those results, first of all, it is necessary to be weighted on Taekwondo wears made of CN in the aspects of the dignity of military arts uniform. Secondly, CS was required to be lighted and enhanced for the subjective sensation. Third, CP weaved honey comb was asked more various design to eliminate sweat high competition power within the scope of the dignity of military arts uniform.
Journal of the Korean Society of Clothing and Textiles
/
v.36
no.3
/
pp.259-268
/
2012
This study suggests quantitative guidelines for inside clothing temperatures to improve the heat tolerance of 20's females in summer. First, the inside clothing temperatures ($T_{cl}$) of each subject was measured in daily use. The subjects were asked to record subjective thermal sensations, clothing items worn, clothing weight, and activities during an experiment designed to determine the comfort zone of $T_{cl}$. In a thermally neutral state, the comfort zone of $T_{cl}$ was decided on a mean value $T_{cl}{\pm}1{\sigma}$. Second, the subjects were asked to wear clothing that would enable them to feel 'slightly warm but still comfortable'. The rest of the processes were the same as previous steps that were designed to understand the way and degree of clothing control. The comfort zone of $T_{cl}$ was decided in the same manner as the previous step. The two comfort zones were combined and named the combined comfort zone of the definitive comfort zone. The results were as follows: 1. Thermally comfortable $T_{cl}$, Hcl were $34.0{\pm}1.1^{\circ}C$, $40{\pm}9%%RH$ and the thermally comfortable ambient climate was $25.0{\pm}1.6^{\circ}C$, $53{\pm}7%$RH. 2. When subjects were asked to wear 'slightly warm but still comfortable', there were difference in thermally comfortable $T_{cl}$, clothing weight and clothing layer by subject. 3. In this study, the optimal $T_{cl}$ was decided on the mid-point of the definitive comfort zone of $T_{cl}$.
The construction of an athlete's tight-fitting garments is very important to the wearer in terms of athletic performance. Therefore pattern development of tight-fitting garments must allow for the full range of human movement and postures. In this study the relationship between the construction of a skate pants pattern and clothing fitting was explored with the aim of improving the comfort of the clothing. The four male subjects were university students between the ages of 20 to 24. Subjective wear sensations of the experimental garments were rated using a seven-point Likert scale on four consecutive days. While wearing the garments, subjects were asked to take five different postures including waist flexion, sitting and others. A Likert-type scale was used for the evaluation, with 7 points indicating the best fit in tight-fitting pants. Results showed differences in the front-rise length and back-rise length between basic pants(A) and modified pants(B,C,D) were -5.16cm and +5.64cm. Comparing the basic pants pattern(A) with modified pants pattern(B), the latter was superior to basic pants(A) in terms of pressure sensation and closeness of fit, but there was no significant difference. Among the four tight-fitting skate pants, A and B pants were superior to the others in terms of fitting and stability of waist and hip sections. In the case of the skate pants, the number of cutting lines in the pattern had an influence on clothing comfort. A minimum cutting line for tight skate pants was better than a maximum cutting line in terms of clothing comfort.
The construction of athlete's tight-fitting garments by reducing the elastic knit pattern is an interesting subject, which directly influences the performance of the wearer. Therefore, relationships between the reduction rates of the men's pants pattern obtained using measurements of Size Korea 2004 and clothing fitting were explored to improve clothing comfort. Two pattern making methods were developed and the reduction rates were applied to those pants depending on the parts of human body. The four male subjects were university students in the ages of 20 to 24. Subjective wear sensations of the experimental garments were rated using seven Likert scales during 4 consecutive days. While wearing the garments, subjects were kept four various postures including waist flexion and sitting etc by requests of the researchers. Likert type scale was used for the evaluation and 7 point indicates that it gave the best fit as tight-fitting pants. As results, differences in the length and girth between two piece pants pattern(style 1) and one piece pants pattern(style 2) were 0.0$\sim$0.3cm. Between two pattern making methods, one piece pants pattern(the style 2) was superior to two piece pants pattern in terms of subjective sensation and fit. Among eight tight-fitting pants, C, D, G, H pants were superior in terms of fitting and stability of waist and hip part to the others. ill case of tight-fitting pants, the reduction rate of the pattern in the course direction, the reduction rate of T2/3(66%) was better than that of T/2(50%), but the reduction rate of the pattern in the wale direction, that of the part of crotch, which was very sensitive part, should be kept the same as suggested earlier by Ziegert(1988).
Heat stress results in fatigue, a decline in strength, alertness., and mental capacity. The problem is compounded when high humidity exists. To help relieve worker heat stress, many types of cooling units are marketed. While workers may experience some cooling, critical body core temperatures often continue to elevate. This study was designed to find the effects of three kinds of cooling vest with portable frozen gel strips on thermophysiological parameters and on temperature and humidity within clothing. The heart rate, rectal, and skin temperature as well as sweat rate and clothing microclimate were measured during 80 min in 5 healthy males. Inquiries were also made into the subjective rating thermal, humidity comfort, and fatigue sensations. The main findings in our experiments are as follows: (a) Physiological parameters such as rectal temperature was the lowest in garb A1, intermediate in garb A, and the highest in garb A2 throughout the experiment. And mean skin temperature was the lowest in garb A, intermediate in garb A1, and the highest in garb A2; (b) Temperature and humidity within clothing (back) were garb in Al, intermediate in garb A, and the highest in garb A2. But the temperature and humidity within clothing (chest) were garb in A, intermediate in garb A1, and the highest in garb A2; (c) Most participants (4 out of 5 persons) answered that they felt more comfortable and fatigueless in garb A1 than in garb A and A2. It is concluded that local cooling in garb A1 of the upper torso could physiological reduce the thermal strain in participants wearing cooling vest.
Journal of the Korean Society of Clothing and Textiles
/
v.36
no.11
/
pp.1174-1185
/
2012
This study develops tight-fitting upper clothing to measure electrocardiography (ECG) data. Taking into consideration the elasticity of the clothing, we made 4 experimental clothes by applying to each a weft reduction rate of 40%, 50%, 60%, and 70%. The 4 experimental clothes were used to measure resting ECG, exercise ECG, and post-exercise ECG for 4 men in their 20s. We compared clothing pressures using sensors on the human body and on a dressform. Subjective wear sensations of the 4 experimental clothes were evaluated using a subjective 7-point scale (with 7 being most excellent). We measured clothing pressures by using the air type pressure (AMI 3037-2) for upper and lower chest sensors in the developed tight-fitting upper clothing. The lower chest sensor showed that the clothing pressure on a human body and dressform changed consistently as the weft reduction rate decreased. The upper chest sensor showed inconsistent changes in clothing pressure as the weft reduction rate decreased. The wearing-test result for preliminary subjects showed that the lower chest sensor was more stable than the upper chest sensor; therefore, we inserted the sensor at the lower chest position before performing ECG. Except for Subject 4, the resting ECGs were stably measured for 3 subjects (Subject 1, Subject 2, and Subject 3) in all the developed clothes (A clothing, B clothing, C clothing, and D clothing). However, D clothing showed stable ECG values after exercise. The results of the experiment showed that we could measure ECG without difficulty using clothes with a weft reduction rate of 40% when the movement was not intense; however, tight-fitting upper clothing with a weft reduction rate of 70% was necessary to measure exercise ECG and post-exercise ECG values.
Journal of the Korean Society of Clothing and Textiles
/
v.38
no.1
/
pp.73-86
/
2014
Persimmon juice dye-printed fabrics with printing were used for a Galot one-piece dress. The Galot dress was assessed in comparison to a white undyed one-piece dress of the same design through a wearing test conducted in a climatic chamber with an air temperature of $30{\pm}1^{\circ}C$, $50{\pm}5%$ R.H, and 0.2m/sec air movement on 4 healthy female subjects in their 20s. The subjects went through a 30-min stable period, a 30-min exercise of walking on a $5^{\circ}$ slope treadmill at 70m/min period, and a 20-min recovery period. In addition, a physiological reaction and subjective sensation were estimated. The results showed that significant differences were mostly observed from a sweating period that occurred during the latter half of the exercise. More specific results are as follows. First, skin temperature on the chest and mean skin temperature were significantly higher (p<.01) in rayon dyed sample dresses. Second, micro-humidity on the back showed a significant difference (p<.01). Both cotton and rayon persimmon juice dyed sample dresses produced lower microhumidity than their counterparts and as for cotton the difference occurred over the entire experimental period; however, it occurred after the middle of the exercise period for rayon. Third, the sweating rate on the back decreased in both cotton and rayon with persimmon juice dye but no significant difference was observed. Fourth, subjective three sensations revealed significant differences between cotton and rayon (p<.01), indicating that the subjects felt more cool, dryer and more comfortable in a cotton Galot. As described above, the analysis of physiological responses and the subjective sensation of undyed and dyed clothing shows the effect of persimmon juice dyeing. Persimmon juice dyeing also seemly increased air permeability, moisture regain and permeability facilitating body heat ventilation, as micro-humidity and sweat rate were lowered. However, this was not shown consistently in subjective responses on comfort especially when wearing rayon dresses.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.