• Title/Summary/Keyword: wearing sensations

Search Result 59, Processing Time 0.023 seconds

The Effects of Season on Physiological Responses of Human Body, Clothing Microclimate, and Subjective Sensations (인체의 생리적 반응과 의복 기후, 주관적 감각에 미친 계절의 영향)

  • 김양원
    • Journal of the Korean Home Economics Association
    • /
    • v.30 no.4
    • /
    • pp.15-26
    • /
    • 1992
  • To investigate the seasonal effects on physiological responses of human body, clothing micro-climate, and subjective sensation, selected the cloths the most frequently dressed by men in spring and fall, and completed wearing trials in the climatic chamber. The results are as follows: 1. Rectal temp. ranged 36.8-37.1$^{\circ}C$ in either spring or fall, and no seasonal effect was found. 2. In skin temp., there was no seasonal effect in forehead, abdomen, and forearm. Skin temp. of chest was higher in spring than in fall. On the contrary, reverse was true in high and leg. Average skin temp. ranged 32.2-33.2$^{\circ}C$ in spring and 32.9-34.$0^{\circ}C$ in fall. 3. Average total sweat rate of spring, 79.4g/hr, was smaller than that of fall, 110.9g/hr. 4. Clothing temp. ranged 28.1-32.8$^{\circ}C$ in spring and 27.6-31.$0^{\circ}C$ in fall. Clothing humidity ranged 36.9-48.9% in spring and 38.2-51.1% in fall. Therefore, clothing microclimate was higher during fall than during spring. As results, skin temp. of the body core except chest did not show seasonal variation, but there was obvious seasonal variation in skin temp. of the extremities. Therefore, seasonal variation should be take into consideration in the experiments related to the cloth. In addition, standard for each season and the degree of work performance should be re-established in clothing micro-climate.

  • PDF

Physiological Responses of Wearing Safety Helmet with Cooling Pack in Hot Environment (머리 냉각시의 인체생리반응 - 안전모 착용을 중심으로 -)

  • Choi, Jeong-Wha;Park, Joon-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.6 s.165
    • /
    • pp.955-965
    • /
    • 2007
  • Safety helmets are used widely in various industries by workers since they are legally required to wear them. However, thermal discomfort is one of the major complaints from helmet users. To relieve this problem, frozen gelled packs can be considered for use inside the helmets. In this paper, tests were performed on humans to evaluate the physiological strains of wearing safety helmets and to investigate the effects of using frozen gelled packs inside the helmets. Experiments were conducted in a climatic chamber of WBGT $33{\pm}1^{\circ}C$ under four differed experimental conditions: 1) not wearing a safety helmet(NH); 2) wearing a safety helmet with frozen gelled pack A(HA); 3) wearing a safety helmet with frozen gelled pack B(HB); and 4) wearing only a safety helmet(OH). The results were as follows. First, when comparing NH with OH, physiological responses such as $\bar{T}_{sk},\;T_r$, HR and sweat rate were significantly higher in OH and subjective sensations were reported as less hot and more comfortable than NH(p<.05). Second, in regard to the frozen gelled packs inserted inside the safety helmets, some physiological responses in HA were different from those in HB, according to the two different types of packs. HA was hotter, more uncomfortable and less exhausted than HB. However, result from both HA and HB were lower than those from OH in terms of temperature and humidity inside safety helmet, sweat rate, $T_r$ increase, heat storage(p<.05). When wearing safety helmets with frozen gelled packs, it was shown that heat strain can be alleviated. These results are expected to help millions of workers who complain that wearing safety helmets is uncomfortable and messy.

Physiological Responses and subjective sensations of the human wearing three different materials of Taekwondo wears (태권도복 소재별 인체생리반응과 주관적 감각에 관한 연구)

  • 김명주;최정화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.5
    • /
    • pp.582-590
    • /
    • 2004
  • The purpose of this study was to evaluate thermal properties of Taekwondo wears with three different materials. As a begging step, the questionnaire survey about the actual condition of Taekwondo wears was conducted. With the results of the questionnaire, cotton/nylon(70/30) blended fabric(CN) that was newly woven with sweat absorbent finishing and cotton/spandex(95/5) blended fabric with flexibility property were developed. The same designed 3 Taekwondo wears with 3 different materials which were two different materials(CN and CS) and a current material(cotton/PET, CP) were made. Four young males volunteered for this study, they kicked and punched as Taekwondo action for 20 minutes. Mean skin temperature was the highest in CS(33.1${\pm}$0.8$^{\circ}C$) and the lowest in CP(32.7${\pm}$0.6$^{\circ}C$). Increasing degree of rectal temperature didn't show any significant difference. Clothing microclimate temperature on the thigh was higher in CS(32.8${\pm}$17.4$^{\circ}C$) than in CN(29.4${\pm}$1.1$^{\circ}C$) and CP(29.4${\pm}$1.0$^{\circ}C$). Clothing microclimate temperature on the back and humidity on the thigh didn't show any significant differences. Clothing microclimate humidity on the back was higher in CP(65${\pm}$20%RH) than in CS(61${\pm}$17%RH). Heart rate, total body weight loss, and local sweating were not significantly different by materials. Most subject responded more hot in CN than in others, but there were no significant differences at the subjective sensation of thermal humidity. They answered more comfortable in CN than in others. Tectile sensations were the best in CN and the worst in CS. From those results, first of all, it is necessary to be weighted on Taekwondo wears made of CN in the aspects of the dignity of military arts uniform. Secondly, CS was required to be lighted and enhanced for the subjective sensation. Third, CP weaved honey comb was asked more various design to eliminate sweat high competition power within the scope of the dignity of military arts uniform.

A Study on Quantitative Wear Training for the Improvement of Heat Tolerance in Summer (Part I) -20's Females' Optimal Wearing: Focus on Inside Clothing Temperatures in Pre-summer- (여름철 내열성 증진을 위한 정량적 착의훈련의 효과 (제1보) -20대 여성의 적정착의 온도 설정: 의복내 온도를 중심으로-)

  • Lee, Hyo-Hyun;Choi, Jeong-Wha
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.3
    • /
    • pp.259-268
    • /
    • 2012
  • This study suggests quantitative guidelines for inside clothing temperatures to improve the heat tolerance of 20's females in summer. First, the inside clothing temperatures ($T_{cl}$) of each subject was measured in daily use. The subjects were asked to record subjective thermal sensations, clothing items worn, clothing weight, and activities during an experiment designed to determine the comfort zone of $T_{cl}$. In a thermally neutral state, the comfort zone of $T_{cl}$ was decided on a mean value $T_{cl}{\pm}1{\sigma}$. Second, the subjects were asked to wear clothing that would enable them to feel 'slightly warm but still comfortable'. The rest of the processes were the same as previous steps that were designed to understand the way and degree of clothing control. The comfort zone of $T_{cl}$ was decided in the same manner as the previous step. The two comfort zones were combined and named the combined comfort zone of the definitive comfort zone. The results were as follows: 1. Thermally comfortable $T_{cl}$, Hcl were $34.0{\pm}1.1^{\circ}C$, $40{\pm}9%%RH$ and the thermally comfortable ambient climate was $25.0{\pm}1.6^{\circ}C$, $53{\pm}7%$RH. 2. When subjects were asked to wear 'slightly warm but still comfortable', there were difference in thermally comfortable $T_{cl}$, clothing weight and clothing layer by subject. 3. In this study, the optimal $T_{cl}$ was decided on the mid-point of the definitive comfort zone of $T_{cl}$.

Pattern Development of Skate Pants Allowing for Dynamic Movement and Postures (인체의 동작을 고려한 스케이트 팬츠 패턴 개발)

  • Jeong, Yeon-Hee
    • Korean Journal of Human Ecology
    • /
    • v.17 no.1
    • /
    • pp.115-126
    • /
    • 2008
  • The construction of an athlete's tight-fitting garments is very important to the wearer in terms of athletic performance. Therefore pattern development of tight-fitting garments must allow for the full range of human movement and postures. In this study the relationship between the construction of a skate pants pattern and clothing fitting was explored with the aim of improving the comfort of the clothing. The four male subjects were university students between the ages of 20 to 24. Subjective wear sensations of the experimental garments were rated using a seven-point Likert scale on four consecutive days. While wearing the garments, subjects were asked to take five different postures including waist flexion, sitting and others. A Likert-type scale was used for the evaluation, with 7 points indicating the best fit in tight-fitting pants. Results showed differences in the front-rise length and back-rise length between basic pants(A) and modified pants(B,C,D) were -5.16cm and +5.64cm. Comparing the basic pants pattern(A) with modified pants pattern(B), the latter was superior to basic pants(A) in terms of pressure sensation and closeness of fit, but there was no significant difference. Among the four tight-fitting skate pants, A and B pants were superior to the others in terms of fitting and stability of waist and hip sections. In the case of the skate pants, the number of cutting lines in the pattern had an influence on clothing comfort. A minimum cutting line for tight skate pants was better than a maximum cutting line in terms of clothing comfort.

Pattern Development of Tight-fitting Pants for Men Using Measurements of Size Korea 2004 (Size Korea 2004의 한국인 인체치수를 이용한 남성용 밀착 팬츠 패턴 개발)

  • Jeong, Yeon-Hee
    • Korean Journal of Human Ecology
    • /
    • v.15 no.5
    • /
    • pp.791-802
    • /
    • 2006
  • The construction of athlete's tight-fitting garments by reducing the elastic knit pattern is an interesting subject, which directly influences the performance of the wearer. Therefore, relationships between the reduction rates of the men's pants pattern obtained using measurements of Size Korea 2004 and clothing fitting were explored to improve clothing comfort. Two pattern making methods were developed and the reduction rates were applied to those pants depending on the parts of human body. The four male subjects were university students in the ages of 20 to 24. Subjective wear sensations of the experimental garments were rated using seven Likert scales during 4 consecutive days. While wearing the garments, subjects were kept four various postures including waist flexion and sitting etc by requests of the researchers. Likert type scale was used for the evaluation and 7 point indicates that it gave the best fit as tight-fitting pants. As results, differences in the length and girth between two piece pants pattern(style 1) and one piece pants pattern(style 2) were 0.0$\sim$0.3cm. Between two pattern making methods, one piece pants pattern(the style 2) was superior to two piece pants pattern in terms of subjective sensation and fit. Among eight tight-fitting pants, C, D, G, H pants were superior in terms of fitting and stability of waist and hip part to the others. ill case of tight-fitting pants, the reduction rate of the pattern in the course direction, the reduction rate of T2/3(66%) was better than that of T/2(50%), but the reduction rate of the pattern in the wale direction, that of the part of crotch, which was very sensitive part, should be kept the same as suggested earlier by Ziegert(1988).

  • PDF

Efficacy of Cooling Vest for Auxiliary Body Cooling in Hot Environments (1) -Thermophysiological Response of Human Body in Local Cooling- (고온환경 하에서 착용하는 인체냉각 보조도구로서의 Cooling Vest 연구(1) -Local Cooling에 따른 인체의 온열생리학적 특성-)

  • Kwon, Oh Kyung;Kim, Jin-A;Kim, Tae Kyu
    • Fashion & Textile Research Journal
    • /
    • v.2 no.3
    • /
    • pp.265-271
    • /
    • 2000
  • Heat stress results in fatigue, a decline in strength, alertness., and mental capacity. The problem is compounded when high humidity exists. To help relieve worker heat stress, many types of cooling units are marketed. While workers may experience some cooling, critical body core temperatures often continue to elevate. This study was designed to find the effects of three kinds of cooling vest with portable frozen gel strips on thermophysiological parameters and on temperature and humidity within clothing. The heart rate, rectal, and skin temperature as well as sweat rate and clothing microclimate were measured during 80 min in 5 healthy males. Inquiries were also made into the subjective rating thermal, humidity comfort, and fatigue sensations. The main findings in our experiments are as follows: (a) Physiological parameters such as rectal temperature was the lowest in garb A1, intermediate in garb A, and the highest in garb A2 throughout the experiment. And mean skin temperature was the lowest in garb A, intermediate in garb A1, and the highest in garb A2; (b) Temperature and humidity within clothing (back) were garb in Al, intermediate in garb A, and the highest in garb A2. But the temperature and humidity within clothing (chest) were garb in A, intermediate in garb A1, and the highest in garb A2; (c) Most participants (4 out of 5 persons) answered that they felt more comfortable and fatigueless in garb A1 than in garb A and A2. It is concluded that local cooling in garb A1 of the upper torso could physiological reduce the thermal strain in participants wearing cooling vest.

  • PDF

Development of Tight-fitting Upper Clothing for Measuring ECG -A Focus on Weft Reduction Rate and Subjective Assessment- (심전도 측정을 위한 밀착 의복 연구 -패턴 축소 및 주관적 평가를 중심으로-)

  • Jeong, Yeonhee;Yang, YoungMo
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.11
    • /
    • pp.1174-1185
    • /
    • 2012
  • This study develops tight-fitting upper clothing to measure electrocardiography (ECG) data. Taking into consideration the elasticity of the clothing, we made 4 experimental clothes by applying to each a weft reduction rate of 40%, 50%, 60%, and 70%. The 4 experimental clothes were used to measure resting ECG, exercise ECG, and post-exercise ECG for 4 men in their 20s. We compared clothing pressures using sensors on the human body and on a dressform. Subjective wear sensations of the 4 experimental clothes were evaluated using a subjective 7-point scale (with 7 being most excellent). We measured clothing pressures by using the air type pressure (AMI 3037-2) for upper and lower chest sensors in the developed tight-fitting upper clothing. The lower chest sensor showed that the clothing pressure on a human body and dressform changed consistently as the weft reduction rate decreased. The upper chest sensor showed inconsistent changes in clothing pressure as the weft reduction rate decreased. The wearing-test result for preliminary subjects showed that the lower chest sensor was more stable than the upper chest sensor; therefore, we inserted the sensor at the lower chest position before performing ECG. Except for Subject 4, the resting ECGs were stably measured for 3 subjects (Subject 1, Subject 2, and Subject 3) in all the developed clothes (A clothing, B clothing, C clothing, and D clothing). However, D clothing showed stable ECG values after exercise. The results of the experiment showed that we could measure ECG without difficulty using clothes with a weft reduction rate of 40% when the movement was not intense; however, tight-fitting upper clothing with a weft reduction rate of 70% was necessary to measure exercise ECG and post-exercise ECG values.

Assessment of Wear Comfort and the Development of One-piece Dresses with Persimmon Juice Dye-printed Fabrics (감즙염색 날염 소재 원피스 개발과 인체착용실험에 의한 생리반응 및 착용감 평가)

  • Park, Soon Ja;Kang, Inhyeng
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.38 no.1
    • /
    • pp.73-86
    • /
    • 2014
  • Persimmon juice dye-printed fabrics with printing were used for a Galot one-piece dress. The Galot dress was assessed in comparison to a white undyed one-piece dress of the same design through a wearing test conducted in a climatic chamber with an air temperature of $30{\pm}1^{\circ}C$, $50{\pm}5%$ R.H, and 0.2m/sec air movement on 4 healthy female subjects in their 20s. The subjects went through a 30-min stable period, a 30-min exercise of walking on a $5^{\circ}$ slope treadmill at 70m/min period, and a 20-min recovery period. In addition, a physiological reaction and subjective sensation were estimated. The results showed that significant differences were mostly observed from a sweating period that occurred during the latter half of the exercise. More specific results are as follows. First, skin temperature on the chest and mean skin temperature were significantly higher (p<.01) in rayon dyed sample dresses. Second, micro-humidity on the back showed a significant difference (p<.01). Both cotton and rayon persimmon juice dyed sample dresses produced lower microhumidity than their counterparts and as for cotton the difference occurred over the entire experimental period; however, it occurred after the middle of the exercise period for rayon. Third, the sweating rate on the back decreased in both cotton and rayon with persimmon juice dye but no significant difference was observed. Fourth, subjective three sensations revealed significant differences between cotton and rayon (p<.01), indicating that the subjects felt more cool, dryer and more comfortable in a cotton Galot. As described above, the analysis of physiological responses and the subjective sensation of undyed and dyed clothing shows the effect of persimmon juice dyeing. Persimmon juice dyeing also seemly increased air permeability, moisture regain and permeability facilitating body heat ventilation, as micro-humidity and sweat rate were lowered. However, this was not shown consistently in subjective responses on comfort especially when wearing rayon dresses.