• Title/Summary/Keyword: wearable patch

Search Result 19, Processing Time 0.021 seconds

Adhesive Polyurethane-based Capacitive Electrode for Patch-type Wearable Electrocardiogram Measurement System (패치형 웨어러블 심전도 측정 시스템을 위한 접착성 폴리우레탄 기반의 용량성 전극)

  • Lee, Jeong Su;Lee, Won Kyu;Lim, Yong Gyu;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.203-210
    • /
    • 2014
  • Wearable medical device has been a resurgence of interest thanks to the development of technology and propagation of smart phone in recent years. Various types of wearable devices have been introduced and available in market. Capacitive coupled electrode which measures electrocardiogram over cloth is able to be applied wearable device. In previous approaches of capacitive electrode, they need proper pressure for stable contact of the electrode to body surface. However, wearable device that gives pressure on body surface is not suitable for long-term monitoring. In this study, we proposed adhesive polyurethane-based capacitive electrode for patch-type wearable electrocardiogram (ECG) monitoring device. Self-adhesive polyurethane make the electrode and whole system be adhered to the surface of skin without any pressure. The patch-type system is consisted of analog filter, analog-to-digital converter and wireless transmission module and designed to be attached on the body as a patch. To validate the feasibility of the developed system, we measured ECG signal in stable and active state and extracted heart rate. Therefore, we observed skin response after long-term attachment for biocompatibility of the adhesive polyurethane and adhesive strength of it. The result shows the possibility of applying the developed system for ECG monitoring in real-life.

Band Type Wearable Device's RF Configuration and Bent Microstrip Patch Antenna (밴드형 Wearable Device의 RF Configuration과 Bent 마이크로스트립 패치 안테나)

  • Lee, Dongho;Choi, Woo Cheol;Kim, Sung Hoe;Yoon, Young Joong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.1
    • /
    • pp.16-23
    • /
    • 2015
  • In this paper, a bent microstrip patch antenna, which is suitable for band-type wearable devices and RF configuration, to be used in the WCDMA2100 mobile network is proposed. The proposed antenna using RF configuration which is consisted of separated Tx and Rx frequency band is designed to operate or function in WCDMA2100 Tx frequency band only and it is not strongly affected by the human body because of the conductor at the bottom side. At both flat case and bent case, the proposed antenna's maximum gain satisfies at least 5.3 dBi, and its -6 dB return loss bandwidth is wider than 20 MHz. The simulated surface absorption rate($SAR_{1g}$) result is under 0.7 [W/kg]. The proposed antenna suits in band-type wearable devices which is worn on wrists or arms.

The Development of a Wearable Prototype to Measure Clothing Pressure through Sensor Calibration Procedure

  • Jin, Heejae;Lee, Hyojeong
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.5
    • /
    • pp.827-835
    • /
    • 2022
  • Clothing pressure is considered the essential factor affecting the comfort of clothing, so it is crucial that it is measured precisely. The purpose of this study is to construct a prototype using the Adafruit Flora as the Arduino system, which can be used as a wearable framework for easy, low-cost, and precise clothing pressure measurement. The study also aims to determine how best to conduct the procedure of sensor calibration. To optimize the accuracy of the sensors, the calibration procedure was implemented using mathematical methods that combined polynomial and exponential regression in a hybrid approach. The prototype can easily measure clothing pressure even during active movements, as seen in the detection of stable signals. In addition, since the system was specifically proposed as a wearable patch that can be easily attached and removed as necessary, it can also be used to standardize the value of clothing pressure in each movement.

Evaluation of the Diagnostic Performance and Efficacy of Wearable Electrocardiogram Monitoring for Arrhythmia Detection after Cardiac Surgery

  • Seungji Hyun;Seungwook Lee;Yu Sun Hong;Sang-hyun Lim;Do Jung Kim
    • Journal of Chest Surgery
    • /
    • v.57 no.2
    • /
    • pp.205-212
    • /
    • 2024
  • Background: Postoperative atrial fibrillation (A-fib) is a serious complication of cardiac surgery that is associated with increased mortality and morbidity. Traditional 24-hour Holter monitors have limitations, which have prompted the development of innovative wearable electrocardiogram (ECG) monitoring devices. This study assessed a patch-type wearable ECG device (MobiCARE-MC100) for monitoring A-fib in patients undergoing cardiac surgery and compared it with 24-hour Holter ECG monitoring. Methods: This was a single-center, prospective, investigator-initiated cohort study that included 39 patients who underwent cardiac surgery between July 2021 and June 2022. Patients underwent simultaneous monitoring with both conventional Holter and patchtype ECG devices for 24 hours. The Holter device was then removed, and patch-type monitoring continued for an additional 48 hours, to determine whether extended monitoring provided benefits in the detection of A-fib. Results: This 72-hour ECG monitoring study included 39 patients, with an average age of 62.2 years, comprising 29 men (74.4%) and 10 women (25.6%). In the initial 24 hours, both monitoring techniques identified the same number of paroxysmal A-fib in 7 out of 39 patients. After 24 hours of monitoring, during the additional 48-hour assessment using the patch-type ECG device, an increase in A-fib burden (9%→38%) was observed in 1 patient. Most patients reported no significant discomfort while using the MobiCARE device. Conclusion: In patients who underwent cardiac surgery, the mobiCARE device demonstrated diagnostic accuracy comparable to that of the conventional Holter monitoring system.

Development of bio-inspired hierarchically-structured skin-adhesive electronic patch for bio-signal monitoring (생체정보 진단을 위한 생체모사 계층구조 기반 피부 고점착 전자 패치 개발)

  • Kim, Da Wan
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.5
    • /
    • pp.749-754
    • /
    • 2022
  • High adhesion and water resistance of the skin surface are required for wearable and skin-attachable electronic patches in various medical applications. In this study, we report a stretchable electronic patch that mimics the drainable structure pattern of the hexagonal channels of frog's pads and the sucker of an octopus based on carbon-based conductive polymer composite materials. The hexagonal channel structure that mimics the pads of frogs drains water and improves adhesion through crack arresting effect, and the suction structure that mimics an octopus sucker shows high adhesion on wet surfaces. In addition, the high-adhesive electronic patch has excellent adhesion to various surfaces such as silicone wafer (max. 4.06 N/cm2) and skin replica surface (max. 1.84 N/cm2) in dry and wet conditions. The high skin-adhesive electronic patch made of a polymer composite material based on a polymer matrix and carbon particles can reliably detect electrocardiogram (ECG) in dry and humid environments. The proposed electronic patch presents potential applications for wearable and skin-attachable electronic devices for detecting various biosignals.

Analysis on the development trend of flexible materials and platforms for wearable devices based on fiber - Based on domestic & international patent data - (섬유기반의 웨어러블 디바이스용 유연소재 및 플랫폼 개발동향 분석 -국내외 특허분석을 중심으로-)

  • Han, Hyunjung;Jang, Myoungjin;Lee, Yongsung
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.22 no.1
    • /
    • pp.33-44
    • /
    • 2020
  • The purpose of this study is to guide the research direction for securing the competitiveness of the textile industry by analyzing the trends of patent technology development for flexible materials and platform technologies of domestic and overseas textiles used for wearable devices. The study is based on patents from Korea (KIPO), USA (USPTO), Japan (JPO), Europe (EPO), PCT (WO), and China (SIPO), which were registered as of December 31, 2017. The analysis utilized 3,643 patents acquired from the WINTELIPS search DB. The technology classification system for patent analysis was divided into evangelist-based textile technology developments: human body (AA), fiber attachment patch development (AB), and service platform development (AC). The analysis findings are as follows: 1. The development of flexible materials and platform technologies for textile-based wearable devices has increased since 2000. In particular, China (SIPO) had the most patents. 2. In China, Japan, and Korea, most patent applicants are applied for by natives, but the US has a high proportion of foreigners applying for patents. 3. As for the amount of development of the evangelist-based textile technology (AA) was the most common with 1,203 (33%) cases. As a result of the above IP historical analysis, it can be seen that as a result of the global competition, domestic companies need to acquire IRP and standard technology, and promote commercialization by applying their products to smart wearables devices and other products.

Biometric information database and service modelling in digital patch system

  • Lee, Tae-Gyu
    • International journal of advanced smart convergence
    • /
    • v.7 no.4
    • /
    • pp.161-168
    • /
    • 2018
  • Recently, the bio-sensing information systems for collecting and analysing human body information of a patient in real time in the field of medical information and healthcare information service are continuously increasing. Specially, various wearable devices such as a wrist, a garment, and a skin attachment type for supporting health information of a mobile user are rapidly increasing. Until now, there is no patch-type biometric information service model. Therefore, this paper presents a biometric information system model and the application examples to support biometric information sensing and health information service of mobile user with digital patch system as a new biometric information system. As a result, through this research, research issues based on digital patch system are searched to suggest the direction of continuous research.

Beam Steering Antenna Using Microstrip Patch with U-Slot for Wearable Fabric Applications (의복용 U-슬롯을 갖는 빔 조향 마이크로스트립 안테나)

  • Ha, Sang-Jun;Jung, Chang-Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.8
    • /
    • pp.754-760
    • /
    • 2011
  • Reconfigurable beam steering using microstrippatch antenna with U-slot is proposed for wearable fabric applications. The proposed antenna is manufactured on a fabric substrate, and designed to steer the beam directions at the operation frequency of 6.0 GHz. The U-shaped slot and the indirect feeding-techniques are utilized in designing the proposed antenna. By the configuration of two artificial switches($S_0$, $S_1$, $S_2$) in between the indirect feed and the antenna patch, the antenna has three beam directions. The maximum beam directions are steerable in the yz-plane(${\theta}=0^{\circ}$, $30^{\circ}$, $331^{\circ}$), and the overall HPBW is $115^{\circ}$. The measured peak gains are 6.11~6.69 dBi.

Laser-induced Graphene Based Wearable Glucose Patch Sensor with Ultra-low Detection Limit (레이저 유도 그래핀 기반의 고성능 웨어러블 포도당 패치센서)

  • Nah, Joongsan;Yoon, Hyosang;Xuan, Xing;Kim, Jiyoung;Park, Jaeyeong
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.47-51
    • /
    • 2019
  • Sweat-based glucose sensors are being widely investigated and researched as they facilitate painless and continuous measurement. However, because the concentration of sweat glucose is almost a hundred times lower than that of blood glucose, it is important to develop electrochemical sensing electrode materials that are highly sensitive to glucose molecules for the detection of low concentrations of glucose. The preparation of a flexible and ultra-sensitive sensor for detection of sweat glucose is presented in this study. Oxygen and nitrogen are removed from the surface of a polyimide film by exposure to a CO2 laser; hence, laser-induced graphene (LIG) is formed. The fabricated LIG electrode showed favorable properties of high roughness and good stability, flexibility, and conductivity. After the laser scanning, Pt nanoparticles (PtNP) with good catalytic behavior were electrodeposited and the glucose sensor thus developed, with a LIG/PtNP hybrid electrode, exhibited a high order of sensitivity and detection limit for sweat glucose.

A Study on Wearable GPS Antenna Integrated into Garment (의복에 실장되는 웨어러블 GPS 안테나에 대한 연구)

  • Park, Dong-Kook
    • Journal of Navigation and Port Research
    • /
    • v.38 no.6
    • /
    • pp.623-627
    • /
    • 2014
  • In recent years, wireless communication technologies in human body have received an increasing attention and the research on an antenna that can be worn also has been actively conducted. In this paper, an wearable antenna that can receive GPS signal frequency is proposed. The antenna was manufactured by using a copper polyester fabric with thickness of 0.08mm as a radiator and a ground plate, and a goatskin with thickness of 0.7mm as dielectric substrate. Cutting edges placed in diagonal direction of square patch in order to obtain a circular polarization characteristic, and the conductive cloth and leather was laminated by using a conductive epoxy. First, goatskin dielectric constant was obtained through the simulation and measurement of resonance frequency of the three square patch antennas with different size. On the basis of the results, an antenna operating in the GPS band was designed and the performance of the antenna was validated by making the experiment. The change of the characteristic of the antenna that is located on the shoulder parts of the clothing and wearing person were measured. And it was confirmed that the reception sensitivity has a similar level as compared to the commercially produced ceramic GPS antenna.