• Title/Summary/Keyword: wear coefficient

검색결과 780건 처리시간 0.039초

Study on Sliding Wear Characteristics and Processing of MoSi

  • Park, Sungho;Park, Wonjo;Huh, Sunchul
    • International Journal of Ocean System Engineering
    • /
    • 제2권4호
    • /
    • pp.244-249
    • /
    • 2012
  • In this study, a monolithic MoSi2 matrix reinforced with 20 vol% SiC particles, a SiC/MoSi2 composite matrix reinforced with 20 vol% ZrO2 particles, and a ZrO2/MoSi2 composite were fabricated using hot press sintering at $1350^{\circ}C$ for 1 h under a pressure of 30 MPa. The Vickers hardness and sliding wear resistance of the monolithic MoSi2, ZrO2/MoSi2, and SiC/MoSi2 composite were investigated at room temperature. A wear behavior test was carried out using a disk-type wear tester with a silicon nitride ball. The ZrO2/MoSi2 composite showed an average Vickers hardness value and excellent wear resistance compared with the monolithic MoSi2 and SiC/MoSi2 composite at room temperature.

주축 변위 측정을 통한 공구 마모 진단에 관한 연구 (A Study on Tool Wear Diagnosis by Measuring Spindle Displacement)

  • 김진현;김일해;장동영;한동철
    • 한국정밀공학회지
    • /
    • 제20권1호
    • /
    • pp.222-228
    • /
    • 2003
  • A reliable tool wear monitoring technique is the one of important aspects for achieving an integrated and self-adjusting manufacturing system. In this paper, a tool wear estimation approach for turning is proposed. This approach uses the model of cutting force, spindle displacement and their relation. A series of experiments were conducted by designing experimental techniques to determine the relationship between flank wear and cutting force coefficient as well as cutting parameters such as cutting speed, depth of cut and feed. The proposed model performance has shown that the spindle displacement model predicts tool wear with high accuracy and spindle displacement signal is possible to replace cutting force signal.

탐침형 정보저장 기술을 위한 실리콘 탐침의 나노 마멸 특성에 관한 연구 (Nano-wear Characteristics of Silicon Probe Tip for Probe Based Data Storage Technology)

  • 이용하;정구현;김대은;유진규;홍승범
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.552-555
    • /
    • 2004
  • The reliability issue of the probe tip/recording media interface is one of the most crucial concerns in the Atomic Force Microscope (AFM)-based recording technology. In this work, the tribological characteristics of the probe/media interface were investigated by performing wear tests using an AFM. The ranges of applied normal load and sliding velocity for the wear test were 10 to 50nN and 2 to 20$\mu$m/s respectively. The damage of the probe tip was quantitatively as well as qualitatively characterized by Field Emission Scanning Probe Microscope (FESEM) analysis and calculated based on Archard s wear equation. It was shown that the wear coefficient of the probe tip was in the order of 10$^{-4}$ ~ 10$^{-3}$ , and significant contamination at the end of the probe tip was observed. Thus in order to implement the AFM-based recording technology, tribological optimization of the probe/media interface must be achieved.

  • PDF

상온 대기 중에서 인코넬 600과 690의 슬라이딩 마모 (Sliding wear of Inconel 600 and 690 in room temperature air)

  • 홍동석;김경국;김준기;김선진
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2003년도 추계학술발표강연 및 논문개요집
    • /
    • pp.91-91
    • /
    • 2003
  • Sliding wear behaviors of Inconel 600 and 690 were investigated at room temperature in air. In the present study, Archard's equation which has low reliability was modified. In the prediction of wear volume by Archard's equation, the reliabilities of Inconel 600 and 690 were about from 26.3% to 45.7% and from 69. l% to 88.6%, respectively, The sliding wear behaviors of Inconel 600 and 690 turned out to be influenced by their stacking fault energy, and the fact was confirmed by using TEM and micro-hardness test Based on experimental results, the wear coefficient was modified as a function of the sliding distance. The calculation with the modified wear equation showed that the reliability of Inconel 600 tested with 409 ferritic stainless steel increased from 45.7% to 93.4%.

  • PDF

주축 변위 측정을 통한 공구 마모 진단에 관한 연구 (A Study on Tool Wear Diagnosis by Measuring Spindle Displacement)

  • 김진현;김일해;장동영;한동철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.459-464
    • /
    • 2001
  • A reliable tool wear monitoring technique is the one of important aspects for achieving an integrated and self-adjusting manufacturing system. In this paper, a tool wear estimation approach for turning is proposed. This approach uses the model of cutting force, spindle displacement and their relation. A series of experiments were conducted by designing experimental techniques to determine the relationship between flank wear and cutting force coefficient as well as cutting parameters such as cutting speed, depth of cut and feed. The proposed model performance has shown that the spindle displacement model predicts tool wear with high accuracy and spindle displacement signal is possible to replace cutting force signal.

  • PDF

지르코니아 충전이 지르코니아계 용사코팅층의 마모마찰에 미치는 영향 (Effect of Sealing Process on the Tribological Behavior of the Plasma Spray Zirconia Based Coatings)

  • 신종한;임대순;안효석
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1998년도 제28회 추계학술대회
    • /
    • pp.265-271
    • /
    • 1998
  • High temperature wear behavior of plasma sprayed zirconia based coating sealing with zirconia sol were investigated for high temperature wear resistance application. The zirconia powders containing 2.5, 5.0, 7.5, 10.0 mol% of MoS$_2$, $Fe_2O_3$ for plasma spray were made by spray drying method. As-sprayed coating was sealed by zirconia-sol to fill up the pore and crack in coating. wear test were performed at temperature ranges from room temperature to 600$\circ$C. The microstructural changes of before and after sealing process were examined by SEM, XRD and EPMA. After sealing process, the porosity was decreased and micro-hardness was increased. The wear properties of coating after sealing process were improved by sealing of pores and cracks. The behavior of wear amount and coefficient of friction were same tendency to before sealing process.

  • PDF

Influence of Tempering Temperature and Microstructure on Wear Properties of Low Alloy PM Steel with 1-2% Ni Addition

  • Tekeli, Suleyman;Gural, Ahmet;Guru, Metin
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.1004-1005
    • /
    • 2006
  • The effect of tempering temperature and microstructure on dry sliding wear behavior of quenched and tempered PM with 0.3% graphite and 1-2% Ni steels was investigated. The sintered specimens were quenched from $890^{\circ}C$ and then tempered at $200^{\circ}C$ and $600^{\circ}C$ for 1 hr. Wear tests were carried out on the quenched$\neq$tempered specimens under dry sliding wear conditions using a pin-on-disk type machine at constant load and speed. The experimental results showed that the wear coefficient effectively increased with increasing tempering temperature and decreased with increasing Ni content.

  • PDF

전차선용 Cu-$TiB_2$ 복합재료의 마모거동에 관한 분석 (The Analysis on Wear Behavior of Cu-$TiB_2$ Composite For Contact Wire)

  • 김정남;이태우;권성태;강계명
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.704-709
    • /
    • 2004
  • The wear behavior and the mechanical property of Cu-$TiB_2$ composites were examined. Cu-$TiB_2$ composites were fabricated by hot extrusion and cold drawing with $TiB_2$ contents(1$\∼$5vol.$\%$) and the size of $TiB_2$ particles(10$\mu$m and 20$\mu$m). The pin-an-disk wear test was carried out under dry sliding wear conditions which loads varied with from 20N to 100N. At the time, counterpart wear material used SM45C. The experimental results showed that the friction coefficient and wear rate decreased with increasing the $TiB_2$ contents and decreasing the size of $TiB_2$ particle. Also, the depth of plastically deformed zone decreased with increasing the $TiB_2$ contents and decreasing the size of $TiB_2$ particle.

  • PDF

플라즈마사용법에 의한 $ZrO_2-Y_2O_3$ 코팅의 고온에서의 마모 (High Temperature Wear of Plasma-Sprayed $ZrO_2-Y_2O_3$ Coatings)

  • 김장엽;임대순;안효석
    • 한국세라믹학회지
    • /
    • 제30권12호
    • /
    • pp.1059-1065
    • /
    • 1993
  • The sliding wear behavior of the plasma sprayed zirconia containing 8wt% yttria was investigated over a range of room temperature to 800℃. Both of the friction coefficient and the wear loss increased reaching its maximum at about to 499℃. and then decreased again with increasing temperature up to 800℃. The worn surface at elevated temperature were observed and analyzed by scanning electron microscopy and X-ray diffractometer to study the mechanisms of high temperature wear behavior. Surface morphology of the worn samples changes with temperature. Monoclinic (m)/tetragonal (t) x-ray peak intensity ratio of wear debris and worn surface decreased with increasing temperature. Non-transformable tetragonal (t') to metastable tetragonal (t) phase transformation of worn surface increased with increasing temperature. The results indicate that dehumidification and above phase changes are contributing to the high temperature wear behavior of the plasma sprayed ZrO2-Y2O3 coatings.

  • PDF

저어널 베어링의 좀머펠트 수 변화에 따른 마모 특성에 관한 연구 (A Study on Wear Properties of Journal Bearing with Sommerfeld Number Variation)

  • 김철우;김경웅
    • Tribology and Lubricants
    • /
    • 제13권2호
    • /
    • pp.16-26
    • /
    • 1997
  • In this paper, the characteristics of lubrication and wear phenomena of journal bearing with respect to film parameter and Sommerfeld number variation are investigated experimentally and the design criterion for the hydrodynamic journal bearing is presented to avoid wear and seizure. Experimental work is performed with various rotating speed and load, and lubricant is used synthetic oil and mineral oil. By the results of the experiment, it is found that friction coefficient is decreased as Sommerfeld number is decreased, and that wear phenomenon is observed when Sommerfeld number is below $9$\times$10^{-4}$ and there are much alike in wear properties between synthetic and mineral oil.