약계자 영역에서 전동기 상수변동에 둔감한 SPMSM의 새로운 약계자 제어기 (A New Robust SPMSM Control to Parameter Variations in Flux Weakening Region)

  • 김장목;송종환;설승기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권5호
    • /
    • pp.264-268
    • /
    • 1999
  • A new implementation strategy for the flux weakening control of a Surface Mounted Permanent Magnet Synchronous Motor (SPMSM) is proposed. It is implemented based on the output of the synchronous PI current regulator-reference voltage to PWM inverter. The onset of flux weakening and the level of the d-axis current are adjusted by the outer voltage regulation loop to prevent the saturation of the current regulator. The characteristics of this flux weakening scheme include no dependency on the machine parameters, the guarantee of current regulation on any operating condition, and fast transition into and out of the flux weakening mode. Experimental results at various operating conditions including 4-quadrant operation are presented to verify the feasibility of the proposed control scheme.

  • PDF

전압 궤환 제어를 위한 약계자 영역에서의 벡터 제어 유도전동기의 최대 토오크 운전 (Voltage Control Strategy for Maximum Torque Operation of Field Oriented Induction Machine in the Field Weakening Region)

  • 김상훈;설승기
    • 대한전기학회논문지
    • /
    • 제43권7호
    • /
    • pp.1084-1092
    • /
    • 1994
  • An induction machine can be operated in the constant power region over an extended high speed range by means of field weakening. A conventional field weakening method is to set the flux reference inversely proportional to the rotor speed. With this method, however, the machines can't yield the maximum torque over the entire high speed range. In this paper, a new field weakening method for the field oriented induction machine drive by the voltage control strategy is presented. The proposed scheme ensures not only producting the maximum torque over the entire field weakening region but also the robust control independent on machine parameters. Also the smooth transition into the field weakening operation and fast dynamic response during transient operation can be obtained. Simulation and experimental results from a 3hp laboratory induction motor drive system are done to confirm the proposed control algorithm.

Advanced Field Weakening Control for Squirrel-Cage Induction Motor in Wide Range of DC-Link Voltage Conditions

  • Son, Yung-Deug;Jung, Jun-Hyung;Kim, Jang-Mok
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.665-673
    • /
    • 2017
  • This paper proposes a field weakening control method for operating an induction motor with a variable DC input voltage condition. In the variable DC voltage condition such as a battery, the field weakening method are required for the maximum output power. The conventional field weakening control methods can be used for operating the induction motor over the rated speed in a constant DC-link voltage condition. However, the conventional methods for operating the motor with the variable DC voltage is not suitable for the maximum output power. To overcome this problem, this paper proposes the optimized field weakening control method to extend the operating range of the induction motor with a rated power in a limited thermal and a wide DC input voltage conditions. The optimized d-axis and q-axis current equations are derived according to the field weakening region I and II to extend the operating region. The experimental results are presented to verify the effectiveness of the proposed method.

내력벽으로 구성된 구조물의 발파해체를 위한 사전취약화 해석 (Pre-weakening Analysis for the Explosive Demolition on the Structural System Consisted of Load Bearing Wall)

  • 최훈;홍순중;문병화;김효진;윤순종
    • 화약ㆍ발파
    • /
    • 제28권2호
    • /
    • pp.76-85
    • /
    • 2010
  • 사전취약화는 발파해체공법의 한 과정으로 구조물의 일부를 해체해 구조물의 붕괴방향 유도 혹은 해체장비의 이동경로확보 등을 목적으로 실시한다. 하지만, 현재 국내에는 사전취약화와 관련된 전문시방서 등의 기준이 정비되어 있지 않은 상태이다. 또한, 구조물의 설계도서가 없는 경우가 많고 무분별한 개보수 및 구조변경등으로 현재 구조물의 상황과 도면이 불일치하는 경우 등 여러 제약요인들로 인해 사전취약화가 정확한 구조해석에 근거하기 보다는 경험에 의해 진행되는 경우가 많다. 이 연구는 내력벽의 사전취약화와 관련된 것으로 내력벽식 구조물의 발파해체를 위한 시공계획의 일부를 소개하고 유한요소해석법을 이용하여 국내에 건설되고 있는 한 아파트 구조물을 대상으로 내력벽의 사전취약화 가능범위를 조사하였으며, 사전취약화 계획시 중요 고려사항에 대해 언급하였다.

약계자 영역에서의 유도전동기 과도 토오크 최대화 기법 (Transient Torque Maximizing Strantegy of Induction Machine in Field Weakening Region)

  • 송승호;최종우;설승기
    • 전력전자학회논문지
    • /
    • 제4권5호
    • /
    • pp.474-482
    • /
    • 1999
  • 본 논문에서는 유도전동기의 전 속도 영역에서 출력토오크를 최대화 할 수 있는 새로운 약계자 제어기를 제시하였다. 전압제한과 전류제한을 모두 고려한 약계자 영역에서의 최적해를 구하였다. 제안된 알고리즘은 자속과 속도를 근거로 하여 변동하는 전압 제한 조건을 만족시키는 전류 기준값을 구하게 된다. 따라서 고정자 전압을 최대한 활용하므로 정상상태 뿐만 아니라 전동기의 자속의 크기가 변화하는 과도상태에서도 최대 출력 토오크와 빠른제어 응답성을 얻을 수 있다. 시뮬레이션 및 실험결과를 통해 제안된 약계자 기법의 효용성을 보였다.

  • PDF

약계자 영역에서 유도전동기의 최대 토오크 운전 (Maximum Torque Operation of an Induction Machine in the field weakening regoin)

  • 김상훈;설승기;박민호
    • 대한전기학회논문지
    • /
    • 제43권2호
    • /
    • pp.225-232
    • /
    • 1994
  • In this paper, a new approach for the induction machine control whih ensures producing maximum torque per ampere over the entire field weakening region is presented. In addition, the relation of the output torque capability with the leakage factor of the machine is examined. Also the smooth and precise transition into the field weakening operation can be achieved by adjusting the base speed for the field weakening operation according to the flux level, the current limit and the voltage limit. The proposed is verified through simulation and experiment for a 5hp laboratory induction motor drive system.

  • PDF

Maximum Torque Operation of Interior Permanent Magnet Synchronous Motor in Flux-Weakening Control

  • Kim, Jan-Mok;Rhew, Hong-Woo;Kwon, Jung-Lock;Sul, Seung-Ki
    • Journal of Electrical Engineering and information Science
    • /
    • 제3권1호
    • /
    • pp.103-109
    • /
    • 1998
  • A new flux-weakening scheme for an Interior Permanent Magnet Synchronous Motor (IPMSM) is proposed. This control scheme enables the maximum torque operation for the fast acceleration in the constant power region according to the current and voltage limit condition. Especially the dynamic performance of the braking in the flux-weakening region is improved with the compensation of the stator resistance. Also since the onset of the flux weakening operation is adjusted according to the load conditions, the machine parameters, and whether motoring or braking region, the stable and precise transition operation into or out of the flux weakening region can be achieved. The effectiveness of the proposed scheme is verified through experiments with an IPMSM drive system.

  • PDF

매입형 영구자석 동기전동기의 약계자 제어시 운전 특성 (Field-weakening control driving characteristics of Interior Permanent Magnet Synchronous Motor)

  • 방태경;신경훈;이승한;조한욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.83-84
    • /
    • 2015
  • In order to use the high-speed range of Interior Permanent Magnet Synchronous Motor(same as IPMSM above), the motor should be at flux weakening control status. High-speed range is called field weakening control region or constant power region, and explain the basic theory of flux weakening control used in the constant power region. Back electromotive force of IPMSM is measured. and field weakening conrtrol driving characteristics is configurated verification test. Through experimentation speed-torque characteristic curve, the efficiency variation corresponding to the current phase angl,the efficiency map were produced.

  • PDF

특수차량용 엔진 직결형 IPMSG의 넓은 속도운전 범위를 위한 부스트/약자속 제어기에 관한 연구 (A Study on Boost/Flux-Weakening Controller for Wide Speed Operation Range having Engine and IPMSG for Special Equipment Vehicle)

  • 이상건;김성안;조윤현
    • 조명전기설비학회논문지
    • /
    • 제28권8호
    • /
    • pp.54-61
    • /
    • 2014
  • This paper proposes a boost/flux-weakening controller (BFWC) for wide speed operation range having engine and interior permanent magnet synchronous generator (IPMSG) for special equipment vehicle. The proposed BFWC exploits direct torque/flux control (DTFC) scheme based on space vector modulation method to control the constant DC voltage output within the entire speed operation range of engine. And, to improve the response characteristics of maximum torque per ampere (MTPA) operation and flux-weakening operation, the MTPA and flux-weakening feed-forward controllers are applied. To estimate feasibility and usefulness of the proposed controller, the simulation and experimental results are compared.

약계자 영역에서 유도 전동기의 고정자 자속 기준 최대 토크 운전을 위한 전압 제어 기법 (Voltage Control Strategy for Maximum Torque Operation of Stator-Flux-Oriented Induction Machine Drive in the Field-Weakening Region)

  • 김홍주;유재성;원충연;김은집;조현규;김상훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.30-32
    • /
    • 2005
  • In this paper, voltage control strategy for maximum torque operation of stator flux-oriented induction machine drive in the field-weakening region is proposed. In a conventional stator flux-oriented (SFO) induction machine drive system of the maximum torque capability cannot be obtained. The field-weakening method is used to vary the stator-flux reference in proportion to the inverse of the rotor speed. The proposed algorithm, based on the voltage control strategy, ensures the maximum torque operation over the field-weakening region. The proposed algorithm, voltage control strategy for maximum torque operation of capability, which is insensitive to the variation of machine parameters In the field-weakening region. The proposed algorithm is verified by simulation.

  • PDF