• Title/Summary/Keyword: weakening

Search Result 743, Processing Time 0.03 seconds

A New Robust SPMSM Control to Parameter Variations in Flux Weakening Region (약계자 영역에서 전동기 상수변동에 둔감한 SPMSM의 새로운 약계자 제어기)

  • Kim, Jang-Mok;Song, Jong-Hwan;Seol, Seung-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.5
    • /
    • pp.264-268
    • /
    • 1999
  • A new implementation strategy for the flux weakening control of a Surface Mounted Permanent Magnet Synchronous Motor (SPMSM) is proposed. It is implemented based on the output of the synchronous PI current regulator-reference voltage to PWM inverter. The onset of flux weakening and the level of the d-axis current are adjusted by the outer voltage regulation loop to prevent the saturation of the current regulator. The characteristics of this flux weakening scheme include no dependency on the machine parameters, the guarantee of current regulation on any operating condition, and fast transition into and out of the flux weakening mode. Experimental results at various operating conditions including 4-quadrant operation are presented to verify the feasibility of the proposed control scheme.

  • PDF

Voltage Control Strategy for Maximum Torque Operation of Field Oriented Induction Machine in the Field Weakening Region (전압 궤환 제어를 위한 약계자 영역에서의 벡터 제어 유도전동기의 최대 토오크 운전)

  • 김상훈;설승기
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.7
    • /
    • pp.1084-1092
    • /
    • 1994
  • An induction machine can be operated in the constant power region over an extended high speed range by means of field weakening. A conventional field weakening method is to set the flux reference inversely proportional to the rotor speed. With this method, however, the machines can't yield the maximum torque over the entire high speed range. In this paper, a new field weakening method for the field oriented induction machine drive by the voltage control strategy is presented. The proposed scheme ensures not only producting the maximum torque over the entire field weakening region but also the robust control independent on machine parameters. Also the smooth transition into the field weakening operation and fast dynamic response during transient operation can be obtained. Simulation and experimental results from a 3hp laboratory induction motor drive system are done to confirm the proposed control algorithm.

Advanced Field Weakening Control for Squirrel-Cage Induction Motor in Wide Range of DC-Link Voltage Conditions

  • Son, Yung-Deug;Jung, Jun-Hyung;Kim, Jang-Mok
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.665-673
    • /
    • 2017
  • This paper proposes a field weakening control method for operating an induction motor with a variable DC input voltage condition. In the variable DC voltage condition such as a battery, the field weakening method are required for the maximum output power. The conventional field weakening control methods can be used for operating the induction motor over the rated speed in a constant DC-link voltage condition. However, the conventional methods for operating the motor with the variable DC voltage is not suitable for the maximum output power. To overcome this problem, this paper proposes the optimized field weakening control method to extend the operating range of the induction motor with a rated power in a limited thermal and a wide DC input voltage conditions. The optimized d-axis and q-axis current equations are derived according to the field weakening region I and II to extend the operating region. The experimental results are presented to verify the effectiveness of the proposed method.

Pre-weakening Analysis for the Explosive Demolition on the Structural System Consisted of Load Bearing Wall (내력벽으로 구성된 구조물의 발파해체를 위한 사전취약화 해석)

  • Choi, Hoon;Hong, Soon-Joong;Mun, Byung-Hwa;Kim, Hyo-Jin;Yoon, Soon-Jong
    • Explosives and Blasting
    • /
    • v.28 no.2
    • /
    • pp.76-85
    • /
    • 2010
  • In this paper, we present the result of an analytical investigation concerning the demolition range for the pre-weakening of load-bearing wall in explosive demolition. Pre-weakening of load-bearing wall is usually conducted based on field experience because reliable specifications or guidelines for the design of pre-weakening have not yet been established in Korea. This study is one of the efforts to develop such a reliable specification or guideline for the pre-weakening process. Hence, the focus of the study is on the estimation of pre-weakening range of load-bearing wall. For the purpose, a finite element analysis (FE analysis) was conducted, and a pre-weakening range of load-bearing wall was suggested based on the analysis result.

Transient Torque Maximizing Strantegy of Induction Machine in Field Weakening Region (약계자 영역에서의 유도전동기 과도 토오크 최대화 기법)

  • 송승호;최종우;설승기
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.5
    • /
    • pp.474-482
    • /
    • 1999
  • In this paper, a new field weakening algorithm which maximizes the output torque not only in steady state b but also in transient state is proposed. Considering both voltage and current limit of system, analytic solutions f for optimal torque utilization in field weakening region I and region II are obtained. This algorithm finds optimal currents considering dynamic vol떠ge limit based on flux and speed. So the maximum usage of stator v voltage even in transient state results in the maximum torque and fast response time. Simulation and e experimental results show the effectiveness of the proposed field weakening scheme.

  • PDF

Maximum Torque Operation of an Induction Machine in the field weakening regoin (약계자 영역에서 유도전동기의 최대 토오크 운전)

  • 김상훈;설승기;박민호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.2
    • /
    • pp.225-232
    • /
    • 1994
  • In this paper, a new approach for the induction machine control whih ensures producing maximum torque per ampere over the entire field weakening region is presented. In addition, the relation of the output torque capability with the leakage factor of the machine is examined. Also the smooth and precise transition into the field weakening operation can be achieved by adjusting the base speed for the field weakening operation according to the flux level, the current limit and the voltage limit. The proposed is verified through simulation and experiment for a 5hp laboratory induction motor drive system.

  • PDF

Maximum Torque Operation of Interior Permanent Magnet Synchronous Motor in Flux-Weakening Control

  • Kim, Jan-Mok;Rhew, Hong-Woo;Kwon, Jung-Lock;Sul, Seung-Ki
    • Journal of Electrical Engineering and information Science
    • /
    • v.3 no.1
    • /
    • pp.103-109
    • /
    • 1998
  • A new flux-weakening scheme for an Interior Permanent Magnet Synchronous Motor (IPMSM) is proposed. This control scheme enables the maximum torque operation for the fast acceleration in the constant power region according to the current and voltage limit condition. Especially the dynamic performance of the braking in the flux-weakening region is improved with the compensation of the stator resistance. Also since the onset of the flux weakening operation is adjusted according to the load conditions, the machine parameters, and whether motoring or braking region, the stable and precise transition operation into or out of the flux weakening region can be achieved. The effectiveness of the proposed scheme is verified through experiments with an IPMSM drive system.

  • PDF

Field-weakening control driving characteristics of Interior Permanent Magnet Synchronous Motor (매입형 영구자석 동기전동기의 약계자 제어시 운전 특성)

  • Bang, Tae-Kyoung;Shin, Kyung-Hun;Lee, Seung-Han;Cho, Han-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.83-84
    • /
    • 2015
  • In order to use the high-speed range of Interior Permanent Magnet Synchronous Motor(same as IPMSM above), the motor should be at flux weakening control status. High-speed range is called field weakening control region or constant power region, and explain the basic theory of flux weakening control used in the constant power region. Back electromotive force of IPMSM is measured. and field weakening conrtrol driving characteristics is configurated verification test. Through experimentation speed-torque characteristic curve, the efficiency variation corresponding to the current phase angl,the efficiency map were produced.

  • PDF

A Study on Boost/Flux-Weakening Controller for Wide Speed Operation Range having Engine and IPMSG for Special Equipment Vehicle (특수차량용 엔진 직결형 IPMSG의 넓은 속도운전 범위를 위한 부스트/약자속 제어기에 관한 연구)

  • Lee, Sang-Geon;Kim, Sung-An;Cho, Yun-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.8
    • /
    • pp.54-61
    • /
    • 2014
  • This paper proposes a boost/flux-weakening controller (BFWC) for wide speed operation range having engine and interior permanent magnet synchronous generator (IPMSG) for special equipment vehicle. The proposed BFWC exploits direct torque/flux control (DTFC) scheme based on space vector modulation method to control the constant DC voltage output within the entire speed operation range of engine. And, to improve the response characteristics of maximum torque per ampere (MTPA) operation and flux-weakening operation, the MTPA and flux-weakening feed-forward controllers are applied. To estimate feasibility and usefulness of the proposed controller, the simulation and experimental results are compared.

Voltage Control Strategy for Maximum Torque Operation of Stator-Flux-Oriented Induction Machine Drive in the Field-Weakening Region (약계자 영역에서 유도 전동기의 고정자 자속 기준 최대 토크 운전을 위한 전압 제어 기법)

  • Kim, H.J.;Yu, J.S.;Won, C.Y.;Kim, E.J.;Jo, H.K.;Kim, S.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.30-32
    • /
    • 2005
  • In this paper, voltage control strategy for maximum torque operation of stator flux-oriented induction machine drive in the field-weakening region is proposed. In a conventional stator flux-oriented (SFO) induction machine drive system of the maximum torque capability cannot be obtained. The field-weakening method is used to vary the stator-flux reference in proportion to the inverse of the rotor speed. The proposed algorithm, based on the voltage control strategy, ensures the maximum torque operation over the field-weakening region. The proposed algorithm, voltage control strategy for maximum torque operation of capability, which is insensitive to the variation of machine parameters In the field-weakening region. The proposed algorithm is verified by simulation.

  • PDF