• 제목/요약/키워드: weak-axis connection

검색결과 28건 처리시간 0.018초

Limiting the sway on multi-storey un-braced steel frames bending on weak axis with partial strength connections

  • Tahir, Mahmood Md.;Ngian, Poi Shek
    • Structural Engineering and Mechanics
    • /
    • 제38권6호
    • /
    • pp.825-847
    • /
    • 2011
  • This paper investigates the design using wind-moment method for semi-rigid un-braced steel frames bending on weak axis. A limiting sway method has been proposed to reduce the frame sway. Allowance for steel section optimization between moment of inertia on minor axis column and major axis beam was used in conjunction with slope-deflection analysis to derive equations for optimum design in the proposed method. A series of un-braced steel frames comprised of two, four, and six bays ranging in height of two and four storey were studied on minor axis framing. The frames were designed for minimum gravity load in conjunction with maximum wind load and vice-versa. The accuracy of the design equation was found to be in good agreement with linear elastic computer analysis up to second order analysis. The study concluded that the adoption of wind-moment method and the proposed limiting sway method for semi-rigid steel frame bending on weak axis should be restricted to low-rise frames not more than four storey.

브라켓 및 WUF-B 형식 철골모멘트골조 약축접합부 내진성능평가 (Cyclic Testing of Bracket and WUF-B Type Weak-Axis Steel Moment Connections)

  • 이강민;정희택;윤석용;이은모;오경환
    • 한국강구조학회 논문집
    • /
    • 제20권4호
    • /
    • pp.483-491
    • /
    • 2008
  • 1994년 노스리지 지진 이후, 철골모멘트골조 강축방향 접합부의 내진성능 평가에 관한 연구가 국내 외에서 활발하게 진행되어온 반면, 국내 철골모멘트골조 내진설계 및 시공의 실무에 관행적으로 적용되고 있는 철골모멘트골조 약축방향 접합부의 내진성능 평가 연구가 국내는 물론 국외에서도 그 사례를 찾아보기 힘든 상황이다. 따라서 본 연구에서는 국내에서 내진성능 확보 여부가 확인되지 않은 상태에서 내진설계 실무에서 가장 많이 사용되고 있는 브라켓 형식 및 WUF-B 형식의 접합상세를 갖는 철골모멘트골조 약축접합부의 실물대(Full scale) 실험체를 제작 및 실험하여 이와 같은 형상의 접합부에 대한 내진성능을 평가하여 향후 이와 같은 형상을 갖는 철골모멘트골조 약축접합부의 설계를 위한 기초자료를 제공하는 것을 목적으로 한다. 이러한 목적을 달성하기 위하여, 현장조사 및 설계도서등의 기존 자료를 통해 총 2개의 실험체를 제작하여 내진성능을 평가 실험연구를 수행하였다. 실험결과로부터 최대내력 비교, 하중-변위 이력 및 응력도 등에 대한 거동을 비교 분석 하였다. 실험결과 층간변위각 5%의 BR-W 실험체가 층간변위각 4%를 갖는 WUF-B 실험체에 비해 우수한 구조적 거동을 보여주었으며, 설계 내력을 상회하는 내력을 보유하고 있는 것을 알 수 있었다. 또한 브라켓 형식의 실험체는 최대내력 도달 이후 완만한 강도 저하를 나타내었으나, WUF-B 형식의 실험체는 최대내력 도달 이후 급격한 하중 저하를 나타내며 취성적인 거동을 보였다.

소규모 철골조 보-기둥 약축 모멘트 접합부의 내진성능 (Seismic Performance of Beam-to-column Weak-axis Moment Connection of Small-size Steel Structure)

  • 임우영;유영찬
    • 한국강구조학회 논문집
    • /
    • 제29권2호
    • /
    • pp.169-180
    • /
    • 2017
  • 본 연구에서는 국내 소규모 철골조 건축물에서 실제 시공된 보-기둥 약축 접합부에 대한 현황조사를 바탕으로 시공성을 향상시킨 약축접합부 상세를 제안하였으며, 제안된 약축접합부에 대한 반복가력 실험을 통해 접합부 내진성능을 평가하였다. 실험변수는 보-기둥 접합부에 사용된 볼트의 개수이다. 실험결과, 본 연구에서 제안하고 있는 보-기둥 약축 접합부의 거동은 수평 스티프너에 연결되는 고력볼트의 개수의 의해 결정되는 것으로 나타났다. 접합부에 4개 이상의 볼트접합이 사용될 경우 현행 기준에서 요구하는 부분 강접합 요구조건을 만족시키는 것으로 나타났다. 모든 실험체는 플랜지 연결플레이트의 연단쪽 보 플랜지 볼트 구멍 주위에서 국부적인 지압파괴와 파단 등이 발생하였다. 하지만, 웨브 높이와 플랜지 폭이 작은 기둥을 사용할 경우, 접합부에 사용되는 고력볼트의 개수가 제한적으로 사용되어야 할 것으로 판단되므로 향후 이 부분에 대한 추가적인 연구가 필요하다.

반강접성을 고려한 강뼈대 구조물의 비선형 해석에 관한 연구 (A Study on the Non-linear Analysis of Steel Frame with Semi-rigid Connections)

  • 이종석;이상엽;김정훈
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.111-118
    • /
    • 1997
  • Generally, H-section is used for columns and beams in the middle and low building steel structure, But it has a axis and a weak axis. Thus if H-section is used for columns, the structure needs reinforcement on the weak axis. Therefore recently, square hollow section(S.H.S) is used for columns because it is able to cover the vulnerability of H-section. Structural analysis is usually executed under the assumption that connections are either ideally pinned joint or fully joint. Actually all connections are semi-rigid which possess a rotational stiffness. Therefore it can be designed economically as using the property of connections which has a rotational stiffness. This paper presents a prediction model curve which is fitted with Kishi-Chen Power Model about the behavior of connection between H-beam and S.H.S column in the previous experimental paper. It also suggests the new analysis algorithm considering the non-linear of semi-rigid connection and the geometrical non-linear under the effect of axial force.

  • PDF

실물크기의 H형강 기둥-보 신형상 약축접합부에 대한 구조성능평가 (Performance Evaluation of Full-scale H-shape Beam-to-Column New-Shape Weak Axis Connection)

  • 심현주;조한솔;김대회;김상섭
    • 한국강구조학회 논문집
    • /
    • 제25권3호
    • /
    • pp.233-242
    • /
    • 2013
  • 현재 가장 많이 사용되는 기존 약축접합부는 브라켓 타입으로 기둥과 보를 접합하는 과정에서 수평 스티프너가 필요하며, 기둥과 브라켓의 용접접합으로 인해 용접량이 비교적 많아 접합부에서 취성파괴가 우려된다. 본 논문은 용접플레이트를 사용함으로써 기존 약축접합부가 가지는 문제점에 대한 해결책을 제시할 수 있는 신형상 약축접합부를 제작해 기존 약축접합부 및 표준 약축접합부와 비교하여 구조성능을 평가하였다. 신형상 약축접합부는 H형강 기둥웨브에서 보 단부사이의 거리를 50mm, 100mm, 150mm, 200mm로 하였다. 실험결과 신형상 약축접합부는 H형강 기둥웨브와 보 단부사이의 거리가 150mm일 때 기준 실험값과 가장 비슷한 것으로 나타났으며, 기존 약축접합부와 표준 약축접합부와 비교해 우수한 구조성능을 가지는 것으로 나타났다.

Visual Basic을 이용한 강뼈대 구조물의 비선형 해석 (Nonlinear Analysis of Steel Frames Using Visual Basic)

  • 윤영조;김선희;이종석
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.403-410
    • /
    • 1999
  • General1y, H-section is used for columns and beams in the middle and low steel building, But it has a strong and weak axis. Thus if H-section is used for columns, the structure needs reinforcement on the weak axis. Therefore recently, square holler section(S.H.S) is used for columns because it is able to coiler the vulnerability of H-section. Structural analysis is usually executed under the assumption that connections are either ideally pinned joint or fully rigid joint. Actually all connections are semi-rigid which possess a rotational stiffness. Therefore it can be designed economically as using the property of connections which has a rotational stiffness. This paper presents a prediction model curve which is fitted Kishi-Chen power Model about the behavior of connection between H-beam and S.H.S column. Non-linear analysis program was considered the non-linearity of semi-rigid connection and the geometrical non-linearity under the effect of axial force. It was programed by FORTRAN90 and Visual Basic.

  • PDF

약축 보-기둥 접합부의 경제성에 관한 연구 (A Study on the Economy of Weak-Axis Beam-to-Column Connections)

  • 박종원;강승민;오용준
    • 한국강구조학회 논문집
    • /
    • 제19권6호
    • /
    • pp.663-670
    • /
    • 2007
  • 국내의 경우 철골 보-기둥의 접합부에 브라켓 형식이 널리 사용되고 있다. 본 연구에서는 브라켓 형식의 접합부에서 약축방향의 접합부를 대상으로 접합부의 디테일을 바꿈으로서 보다 경제적이면서 동시에 기존의 접합 디테일을 사용한 접합부와 구조적으로 유사한 성능을 발휘할 수 있는 접합부를 개발하였다. 접합 디테일을 다르게 한 4개의 접합부를 제안하고 이에 대해 경제성을 비교하였다. 또한 제안된 접합형식의 구조적 성능을 검증하기 위해 기존 접합 디테일을 포함하여 총 다섯 개의 시험체를 제작하고 이에 대한 최대내력 실험연구를 수행하였다. 4개의 제안된 접합형식 모두 기존의 접합형식에 비해 경제적인 것으로 나타났으며 최대내력 실험의 경우 한 접합형식을 제외하고 모두 보의 소성모멘트를 발휘할 수 있었으며 기존의 접합형식과 유사한 충분한 변형특성을 발휘할 수 있는 것으로 나타났다.

소규모 철골조건축물을 위한 약축방향 노출형 주각부의 내진성능 향상 (Seismic Performance Enhancement of Exposed Column-base Plate Weak-axis Connections for Small-Sized Steel Buildings)

  • 유영찬
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권5호
    • /
    • pp.1-12
    • /
    • 2019
  • 소규모 철골조건축물의 접합상세에 대한 현장조사에 따르면 지진하중에 의한 횡적 안전성 및 안정성 확보가 불충분할 것으로 예상되는 임의 접합상세가 현장에서 적용되는 것으로 조사되었다. 이에 따라 본 연구에서는 소규모 강구조건축물의 노출형 주각부 약축 연결부의 반복이력 실험을 통해 문제점을 분석하고, 이를 바탕으로 내진성능을 향상시킬 수 있는 접합상세의 개발을 위해 일련의 실험연구를 수행하였다. 본 실험결과에 의하면, 국내에서 흔히 사용되는 노출형 주각부 약축방향 접합부의 이력거동은 앵커볼트가 콘크리트로부터 점진적으로 인발됨에 따라 베이스플레이트와 앵커볼트사이에 이격거리가 누적되어 하중역전구간에서 "Rocking" 현상이 발생되어 내진성능이 매우 낮은 것으로 조사되었다. 이와 같은 문제점을 개선하기 위하하여 앵커볼트의 콘크리트에 대한 부착 유/무와 개수 및 배열형태 등을 변수로 한 성능개선 실험체에 대한 일련의 반복 이력 실험을 수행하였으며, 최종적으로 소규모철골조 건축물의 노출형 주각부에 고강도 전산볼트형 앵커볼트를 8개로 3열로 배치하는 상세의 적용을 통하여 하중지지능력과 에너지분산능력 측면에서 내진성능이 크게 개선된 것을 확인할 수 있었다.

Experimental study on seismic performance of concrete filled tubular square column-to-beam connections with combined cross diaphragm

  • Choi, Sung-Mo;Yun, Yeo-Sang;Kim, Jin-Ho
    • Steel and Composite Structures
    • /
    • 제6권4호
    • /
    • pp.303-317
    • /
    • 2006
  • The connection with combined cross diaphragm is developed for the connection of square CFT column and steel beam and proposed to be used for the frame with asymmetric span length. The structural characteristics of this connection lie in the penetration of the beam flange in the direction of major axis through the column for the smooth flow of stress. The purpose of this study is to analyze the dynamic behavior and stress flow of suggested connection and to evaluate the resistance to shock of connection. Four T-type CFT column-to-beam specimens; two with combined cross diaphragm and the others with interior and through diaphragms, the existing connection types, were made for cyclic load test guided by the load program of ANSI/AISC SSPEC 2002. The results show that the proposed connection is more efficient than existing ones in terms of strength, stress flow and energy absorption and satisfies the seismic performance required in the region of weak/moderate earthquakes.

Numerical investigation seismic performance of rigid skewed beam-to-column connection with reduced beam section

  • Zareia, Ali;Vaghefi, Mohammad;Fiouz, Ali R.
    • Structural Engineering and Mechanics
    • /
    • 제57권3호
    • /
    • pp.507-528
    • /
    • 2016
  • Reduced beam section (RBS) moment resisting connections are among the most economical and practical rigid steel connections developed in the aftermath of the 1994 Northridge and the 1995 Kobe earthquakes. Although the performance of RBS connection has been widely studied, this connection has not been subject to in the skewed conditions. In this study, the seismic performance of dogbone connection was investigated at different angles. The Commercial ABAQUS software was used to simulate the samples. The numerical results are first compared with experimental results to verify the accuracy. Nonlinear static analysis with von Mises yield criterion materials and the finite elements method were used to analyze the behavior of the samples The selected Hardening Strain of materials at cyclic loading and monotonic loading were kinematics and isotropic respectively The results show that in addition to reverse twisting of columns, change in beam angle relative to the central axis of the column has little impact on hysteresis response of samples. Any increase in the angle, leads to increased non-elastic resistance. As for Weak panel zone, with increase of the angle between the beam and the column, the initial submission will take place at a later time and at a larger rotation angle in the panel zone and this represents reduced amount of perpendicular force exerted on the column flange. In balanced and strong panel zones, with increase in the angle between the beam and the central axis of the column, the reduced beam section (RBS), reaches the failure limit faster and at a lower rotation angle. In connection of skewed beam, balanced panel zone, due to its good performance in disposition of plasticity process away from connection points and high energy absorption, is the best choice for panel zone. The ratio of maximum moment developed on the column was found to be within 0.84 to 1 plastic anchor point, which shows prevention of brittle fracture in connections.