Limiting the sway on multi-storey un-braced steel frames bending on weak axis with partial strength connections

  • Tahir, Mahmood Md.;Ngian, Poi Shek
    • Structural Engineering and Mechanics
    • /
    • v.38 no.6
    • /
    • pp.825-847
    • /
    • 2011
  • This paper investigates the design using wind-moment method for semi-rigid un-braced steel frames bending on weak axis. A limiting sway method has been proposed to reduce the frame sway. Allowance for steel section optimization between moment of inertia on minor axis column and major axis beam was used in conjunction with slope-deflection analysis to derive equations for optimum design in the proposed method. A series of un-braced steel frames comprised of two, four, and six bays ranging in height of two and four storey were studied on minor axis framing. The frames were designed for minimum gravity load in conjunction with maximum wind load and vice-versa. The accuracy of the design equation was found to be in good agreement with linear elastic computer analysis up to second order analysis. The study concluded that the adoption of wind-moment method and the proposed limiting sway method for semi-rigid steel frame bending on weak axis should be restricted to low-rise frames not more than four storey.

Cyclic Testing of Bracket and WUF-B Type Weak-Axis Steel Moment Connections (브라켓 및 WUF-B 형식 철골모멘트골조 약축접합부 내진성능평가)

  • Lee, Kang Min;Jeong, Hee Taek;Yoon, Seok Ryong;Lee, Eun Mo;Oh, Kyung Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.4
    • /
    • pp.483-491
    • /
    • 2008
  • There has been much focus on the strong axis steel moment connections after the Northridge earthquake in 1994. However, research studieson the seismic behavior of weak axis moment connections could be hardly found despite the fact that these connection details have been frequently used as seismic details of MRF in Korea. Therefore, the objective of this research is to provide better knowledge on the seismic behavior of weak-axis steel moment connections, which can be widely applicable to many structures with similar characteristics. For this purpose, an experimental program was designed and performed with twotypes of weak-axis steel moment connections, namely the bracket type and WUF-B type, based on the survey of existing field data and literatures. Using the experimental results obtained from the quasi-static cyclic testing of these specimens, structural performances of the joints such as hysteretic curves, maximum strength capacities and the strain of reinforced bars were investigated. From the test results, the bracket-type connection was shown to have more than a 5% story drift capacity, compared with the WUF-B type connection's 4%. These specimens were also shown to have higher strength capacities than the nominal design strength. The bracket-type connection showed a slow strength degradation after maximum strength was researched. However,the WUF-B type connection showed a rapid strength degradation that caused brittle behavior.

Seismic Performance of Beam-to-column Weak-axis Moment Connection of Small-size Steel Structure (소규모 철골조 보-기둥 약축 모멘트 접합부의 내진성능)

  • Lim, Woo-Young;You, Young-Chan
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.2
    • /
    • pp.169-180
    • /
    • 2017
  • Cyclic loading tests for beam-to-column weak-axis connections were performed to investigate the seismic performance. In this study, the connections were developed to improve the constructability on the basis of investigation for existing small-size steel structures. The primary test parameter is the number of high-tension bolts which are used to connect steel beam and column using exterior and interior flange plates. Test results showed that the number of bolts had a significant effect on the cyclic behavior of beam-column weak-axis connections. From the analysis of test results, it is concluded that more than four bolts in the connections can satisfy the requirements of semi-rigid connection presented in current design codes. All of specimens showed the bearing failure around bolt holes and fracture at the beam flange. However, when the web height and the flange width is relatively small, the number of the bolts used in the connections might be limited. Thus, the additional research in this area is needed.

A Study on the Non-linear Analysis of Steel Frame with Semi-rigid Connections (반강접성을 고려한 강뼈대 구조물의 비선형 해석에 관한 연구)

  • 이종석;이상엽;김정훈
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1997.10a
    • /
    • pp.111-118
    • /
    • 1997
  • Generally, H-section is used for columns and beams in the middle and low building steel structure, But it has a axis and a weak axis. Thus if H-section is used for columns, the structure needs reinforcement on the weak axis. Therefore recently, square hollow section(S.H.S) is used for columns because it is able to cover the vulnerability of H-section. Structural analysis is usually executed under the assumption that connections are either ideally pinned joint or fully joint. Actually all connections are semi-rigid which possess a rotational stiffness. Therefore it can be designed economically as using the property of connections which has a rotational stiffness. This paper presents a prediction model curve which is fitted with Kishi-Chen Power Model about the behavior of connection between H-beam and S.H.S column in the previous experimental paper. It also suggests the new analysis algorithm considering the non-linear of semi-rigid connection and the geometrical non-linear under the effect of axial force.

  • PDF

Performance Evaluation of Full-scale H-shape Beam-to-Column New-Shape Weak Axis Connection (실물크기의 H형강 기둥-보 신형상 약축접합부에 대한 구조성능평가)

  • Shim, Hyun Ju;Cho, Han Sol;Kim, Dae Hoi;Kim, Sang Seup
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.3
    • /
    • pp.233-242
    • /
    • 2013
  • This paper reports a new beam-to-column connection that is suitable for use in the weak axis of a column. The proposed system mainly uses bolts, and it minimizes the use of welding, which is generally difficult to perform onsite. In this system, a H-shape steel beam is joined to a H-shape steel column by bolted splices at the top flange and without a scallop at the web. The structural performance of the proposed connection was verified through full-scale tests of nine specimens, taking into account the effects of the geometry and arrangement of the plate.

Nonlinear Analysis of Steel Frames Using Visual Basic (Visual Basic을 이용한 강뼈대 구조물의 비선형 해석)

  • 윤영조;김선희;이종석
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.10a
    • /
    • pp.403-410
    • /
    • 1999
  • General1y, H-section is used for columns and beams in the middle and low steel building, But it has a strong and weak axis. Thus if H-section is used for columns, the structure needs reinforcement on the weak axis. Therefore recently, square holler section(S.H.S) is used for columns because it is able to coiler the vulnerability of H-section. Structural analysis is usually executed under the assumption that connections are either ideally pinned joint or fully rigid joint. Actually all connections are semi-rigid which possess a rotational stiffness. Therefore it can be designed economically as using the property of connections which has a rotational stiffness. This paper presents a prediction model curve which is fitted Kishi-Chen power Model about the behavior of connection between H-beam and S.H.S column. Non-linear analysis program was considered the non-linearity of semi-rigid connection and the geometrical non-linearity under the effect of axial force. It was programed by FORTRAN90 and Visual Basic.

  • PDF

A Study on the Economy of Weak-Axis Beam-to-Column Connections (약축 보-기둥 접합부의 경제성에 관한 연구)

  • Park, Jong Won;Kang, Seoung Min;Oh, Yong Jun
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.6
    • /
    • pp.663-670
    • /
    • 2007
  • Column-tree beam-to-column joints are widely used in moment-resisting frames in Korea. In this study, we proposed four different arrangements for weak-axis moment-resisting beam-to-column connections, which are more economical than the conventional connection, while developing similar structural performance. We investigated the proposed connections whose connection details were different from the conventional one. The experiment was also conducted on a total of five beam-to-column joint specimensto verify the structural performance of the proposed connections. All four connections proposed in this study were found to be more economical that the conventional connection. Three out of four specimens with proposed details were able to developa structural performance similar to that of the specimen with the conventional detail.

Seismic Performance Enhancement of Exposed Column-base Plate Weak-axis Connections for Small-Sized Steel Buildings (소규모 철골조건축물을 위한 약축방향 노출형 주각부의 내진성능 향상)

  • You, Young-Chan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.5
    • /
    • pp.1-12
    • /
    • 2019
  • The purpose of this study is to enhance the seismic performance of exposed column-base plate weak-axis connections for small-sized steel buildings. According to the site inspection for the small-sized building construction, the arbitrary connection details in steel buildings have been applied at the job site, which is considered to be insufficient to guarantee structural safety and stability considering the increased seismic risk in Korea. Therefore, a series of test programs had been done to develop enhanced connection details in order to ensue the adequate seismic stability and safety of small-sized steel buildings. From the test results, It was found that the exposed column-base plate weak-axis connections commonly used in Korea shows very poor seismic behavior due to the "Rocking" phenomena caused by the residual plastic deformation of anchor bolts between anchor plate and concrete. A series of hysteretic tests for finding that solution were conducted to reduce the "Rocking" phenomena of the column-base plate connections, and local buckling of webs in H-column. Finally the enhanced stable seismic behavior was obtained by reinforcing at least 8 anchor bolts with good bonding strength and stiffeners to the webs in H-column.

Experimental study on seismic performance of concrete filled tubular square column-to-beam connections with combined cross diaphragm

  • Choi, Sung-Mo;Yun, Yeo-Sang;Kim, Jin-Ho
    • Steel and Composite Structures
    • /
    • v.6 no.4
    • /
    • pp.303-317
    • /
    • 2006
  • The connection with combined cross diaphragm is developed for the connection of square CFT column and steel beam and proposed to be used for the frame with asymmetric span length. The structural characteristics of this connection lie in the penetration of the beam flange in the direction of major axis through the column for the smooth flow of stress. The purpose of this study is to analyze the dynamic behavior and stress flow of suggested connection and to evaluate the resistance to shock of connection. Four T-type CFT column-to-beam specimens; two with combined cross diaphragm and the others with interior and through diaphragms, the existing connection types, were made for cyclic load test guided by the load program of ANSI/AISC SSPEC 2002. The results show that the proposed connection is more efficient than existing ones in terms of strength, stress flow and energy absorption and satisfies the seismic performance required in the region of weak/moderate earthquakes.

Numerical investigation seismic performance of rigid skewed beam-to-column connection with reduced beam section

  • Zareia, Ali;Vaghefi, Mohammad;Fiouz, Ali R.
    • Structural Engineering and Mechanics
    • /
    • v.57 no.3
    • /
    • pp.507-528
    • /
    • 2016
  • Reduced beam section (RBS) moment resisting connections are among the most economical and practical rigid steel connections developed in the aftermath of the 1994 Northridge and the 1995 Kobe earthquakes. Although the performance of RBS connection has been widely studied, this connection has not been subject to in the skewed conditions. In this study, the seismic performance of dogbone connection was investigated at different angles. The Commercial ABAQUS software was used to simulate the samples. The numerical results are first compared with experimental results to verify the accuracy. Nonlinear static analysis with von Mises yield criterion materials and the finite elements method were used to analyze the behavior of the samples The selected Hardening Strain of materials at cyclic loading and monotonic loading were kinematics and isotropic respectively The results show that in addition to reverse twisting of columns, change in beam angle relative to the central axis of the column has little impact on hysteresis response of samples. Any increase in the angle, leads to increased non-elastic resistance. As for Weak panel zone, with increase of the angle between the beam and the column, the initial submission will take place at a later time and at a larger rotation angle in the panel zone and this represents reduced amount of perpendicular force exerted on the column flange. In balanced and strong panel zones, with increase in the angle between the beam and the central axis of the column, the reduced beam section (RBS), reaches the failure limit faster and at a lower rotation angle. In connection of skewed beam, balanced panel zone, due to its good performance in disposition of plasticity process away from connection points and high energy absorption, is the best choice for panel zone. The ratio of maximum moment developed on the column was found to be within 0.84 to 1 plastic anchor point, which shows prevention of brittle fracture in connections.