• Title/Summary/Keyword: we

Search Result 325,096, Processing Time 0.278 seconds

Urinary Tract Infection Following Voiding Cystourethrography (배뇨 방광 요도 조영술 시행 후 발생하는 요로 감염에 대한 고찰)

  • Ryu, Jung-Min;Ahn, Yo-Han;Lee, So-Hee;Choi, Hyun-Jin;Lee, Beom-Hee;Kang, Hee-Gyung;Ha, Il-Soo;Cheong, Hae-Il;Choi, Yong
    • Childhood Kidney Diseases
    • /
    • v.12 no.2
    • /
    • pp.194-201
    • /
    • 2008
  • Purpose : Voiding cystourethrography(VCUG) is required to detect vesicoureteral reflux(VUR), which may manifest as urinary tract infection(UTI) in children. It is well known that VCUG can cause UTI(post-VCUG UTI). In this study, risk factors for post-VCUG UTI and the preventive effect of antibiotics against this complication of VCUG were explored. Methods : Medical records of 284 patients who underwent VCUG at our hospital in 2007 were reviewed retrospectively. The incidence of post-VCUG UTI and risk factors for post-VCUG UTI, and the impact of antibiotic use on prevention of post-VCUG UTI were evaluated. According to antibiotics usage, we divided the enrolled patients into 4 groups of noantibiotics group, prophylactic antibiotics group(prophylactic antibiotics having been used before), antibiotics-for-VCUG group(antibiotics added for VCUG) and antibiotics-for-treatment group(treatment dose of antibiotics). Results : Seven of 284 children(2.5%) developed UTI after they underwent VCUG. Highgrade(grade$\geq$III) VUR was the only statistically significant risk factor(odds ratio[OR] 6.266, P=0.026) for post-VCUG UTI, while sex, age, and other anomalies of urinary system were not significant. Five post-VCUG UTI cases belonged to prophylactic antibiotics group. Antibiotics use (three groups using antibiotics vs. no-antibiotics group) or addition of antibiotics for VCUG (antibiotics-for-VCUG vs. other groups) did not have any effect on prevention of post-VCUG UTI. Conclusion : The risk factor for post-VCUG UTI was high-grade VUR. Antibiotics use did not prevent post-VCUG UTI in this study.

Environmental factors Associated with Disease Development of Garlic White Rot Caused by Two Species of Sclerotium (온도와 토양습도가 마늘 흑색썩음균핵병 발생에 미치는 영향)

  • Kim Yong-Ki;Kwon Mi-Kyung;Shim Hong-Sik;Kim Tack-Soo;Yeh Wan-Hae;Cho Weon-Dae;Choi In-Hu;Lee Seong-Chan;Ko Sug-Ju;Lee Yong-Hwan;Lee Chan-Jung
    • Research in Plant Disease
    • /
    • v.11 no.2
    • /
    • pp.128-134
    • /
    • 2005
  • This study was conducted to elucidate effect of environmental factors on the development of white rot. In order to identify the causal agents causing white rot of Allium crops, we compared DNA profiles of a representative isolate, Sclerotium cepivorum, introduced from foreign country with Korean isolates using UP-PCR. As a result, Sclerotium isolates forming round-shaped sclerotia were identified as Sclerotium cepivorum pertaining in UP-PCR b group and Sclerotium isolates farming anamorphic-shaped sclerotia presumed to be a novel species of Sclerotium based on DNA profiles of UP-PCR. There was a big difference in DNA band pattern between two species of Sclerotium isolated in Korea. Electron micrographs of scanning electron microscope and transmission electron microscope showed morphological differences in sclerotial surface structure and rind layers between two species of Sclerotium. There were more wrinkles and pore spaces on sclerotial surface of Sclerotium sp. forming anamorphic-shaped sclerotia than that of Sclerotium cepivorum forming round-shaped sclerotia. Both of two white rot pathogens grew well at the temperature range of $10-25^{\circ}C$ with optimal temperature of $20^{\circ}C$. Sclerotia of the two pathogens were well formed at $20^{\circ}C$ and well germinated at the temperature range of $20-24^{\circ}C$, Effect of pre-incubation of sclerotia on destruction of sclerotial dormancy of two pathogens was evaluated through storing sclerotia under different temperature condition. The sclerotia of the two pathogens showed an increased capacity to germinate on potato dextroise agar when the sclerotia were incubated for 7 days at $10^{\circ}C$ after pre-treatment at $35^{\circ}C$ for 7 days. At that time, germination rate of Sclerotium sp. and 5. cepivorum was $100\%\;and\;70\%$, respectively. Flooding period and treatment temperature had an effect on sclerotial survival rate of the two pathogens. As flooding period and treatment temperature increased, sclerotial germination rate of the two pathogens decreased. It was confirmed that soil humidity played an important role on development of white rot. It was the highest disease incidence of garlic white rot when garlic were sown at potted soils infested with the two pathogens and adjusted soil humidity to $15\%$ (field moisture capacity, about -300 mb). As soil humidity increase or decrease based on $15\%$ of soil humidity, disease incidence decreased move and more.

Control of Bakanae Disease of Rice by Seed Soaking into the Mixed Solution of Procholraz and Fludioxnil (Prochlornz와 fludioxonil 혼용침지소독에 의한 벼 키다리병 방제)

  • Park, Woo-Sik;Choi, Hyo-Won;Han, Seong-Suk;Shin, Dong-Beum;Shim, Hyeong-Kwon;Jung, En-Seon;Lee, Se-Weon;Lim, Chun-Keun;Lee, Yong-Hwan
    • Research in Plant Disease
    • /
    • v.15 no.2
    • /
    • pp.94-100
    • /
    • 2009
  • These experiments were conducted to improve the effect of seed disinfection on rice seed severely infected Bakanae disease by seed soaking into mixed solution of prochloraz EC and fludioxonil FS. We investigated the effects of various concentrations of two fungicides mixed solution on spore germination and mycelial growth of Fusarium fujikuroi. Mycelial growth was inhibited 100% at $10{\mu}g$/ml of prochloraz and 33.3% at $80{\mu}g$/ml of fludioxonil. Spore germination was inhibited 81.4% at $40{\mu}g$/ml of prochloraz. Interestingly, mixed solution of $5{\mu}g$/ml or $10{\mu}g$/ml of each fungicide inhibitied 100% of mycelial growoth and 99.2% of spore germination, respectively. Severely infected rice seeds soaked into mixed solution composed of $125{\mu}l$/ml of prochloraz and $50{\mu}l$/ml of fludioxonil showed 2.1% of disease symptoms compared to 20.4% of prochloraz $125{\mu}l$/ml, but higher concentrations of prochloraz decreased the seedling stand rate. When the seed soaking time was longer and temperature was higher, control effect on Bakanae disease was improved, but seedling stand was lower about 80% over $35^{\circ}C$.

Biological Control of Fusarium Head Blight on Wheat by Polyacetylenes Derived from Cirsium japonicum Roots (대계근에서 분리한 Polyacetylene계 화합물을 이용한 밀 이삭마름병 방제)

  • Kim, Ji-In;Kim, Kihyun;Park, Ae Ran;Choi, Gyung Ja;Park, Hae Woong;Kim, In Seon;Kim, Jin-Cheol
    • Research in Plant Disease
    • /
    • v.22 no.3
    • /
    • pp.145-151
    • /
    • 2016
  • Chemical fungicides have reduced Fusarium head blight (FHB) severity. However, by the effects of fungicide residues, they can only be used up to 30 days before time of harvest. Therefore, the development of new biofungicides that are applicable until harvest is required. In order to select plant extracts having antifungal activity against Fusarium graminearum for the control of FHB, we investigated the inhibitory effects of 225 medicinal plant extracts on spore germination of F. graminearum. Of these plant extracts, the methanol extract of Cirsium japonicum (CJ) roots showed the strongest antifungal activity. Through solvent partitioning, repeated column chromatography, and spore germination bioassay, two chemicals were purified and then their chemical structures were identified as ciryneol C (CC) and 1-heptadecene-11,13-diyne-8,9,10-triol (HD-ol) which are polyacetylene substances. Two active compounds effectively inhibited the germination of F. graminearum macroconidia; HD-ol ($IC_{50}$ of $3.17{\mu}g/ml$) showed stronger spore germination inhibitory activity than that of CC ($IC_{50}$ of $28.14{\mu}g/ml$). In addition, the wettable powder type formulation of ethyl acetate extract of CJ roots suppressed the development of FHB in dose-dependent manner, with control values of 78.92% and 31.56% at 250- and 500-fold dilutions, respectively. Combining these findings suggest that the crude extract of CJ roots containing polyacetylene compounds could be used as botanical fungicide for the control of FHB.

Morphometric Study on the Arterial Palmar Arch of the Hand (손바닥 동맥활에 관한 형태계측 연구)

  • Park, Bong Kwon;Jang, Soo Won;Choi, Seung Suk;Ahn, Hee Chang
    • Archives of Plastic Surgery
    • /
    • v.36 no.6
    • /
    • pp.691-701
    • /
    • 2009
  • Purpose: Deviations of arterial palmar arches in the hand can be explained on the embryological basis. The purpose of this study was to provide new information about palmar arches through cadaver's dissection. The values of the location and diameter in these vessels were analyzed in order to support anatomical research and clinical correlation in the hand. Methods: The present report is based on an analysis of dissections of fifty - three hands carried out in the laboratory of gross anatomy. A reference line was established on the distal wrist crease to serve as the X coordinate and a perpendicular line drawn through the midpoint between middle and ring fingers, which served as the Y coordinate. The coordinates of the x and y values were measured by a digimatic caliper, and statistically analyzed with Student's t - test. Results: Complete superficial palmar archs were seen in 96.2 % of specimens. In the most common type of males, the superficial arch was formed only by the ulnar artery. In the most common type of females, the superficial arch was formed anastomosis between the radial artery and the ulnar artery. The average length of the superficial and deep palmar arch is $110.3{\pm}33.0mm$ and $67.9{\pm}14.0mm$ respectively. Regarding the superficial palmar arch, ulnar artery starts $-16.1{\pm}5.1mm$ on X - line, and $2.5{\pm}24.5mm$ on Y - line. Radial artery appears on palmar side $7.7{\pm}3.2mm$ on X - line, and $20.9{\pm}10.9mm$ on Y - line. But radial artery starts on $6.3{\pm}3.6mm$ on X - line, and $3.4{\pm}5.1mm$ on Y - line. Digital arteries of superficial palmar arch starts on $6.1{\pm}3.7mm$, $33.9{\pm}8.8mm$ on index finger, $1.8{\pm}3.4mm$, $40.1{\pm}7.3mm$ on middle finger, $-3.2{\pm}4.9mm$, $42.6{\pm}7.0mm$ on ring finger, and $-8.9{\pm}5.1mm$, $42.5{\pm}80mm$ on little finger in respective X and Y coordinates. Radial artery of deep palmar arches measured at the palmar side perforating from the dorsum of hand. It's coordinates were $9.7{\pm}4.8mm$ on X - line, $21.7{\pm}10.2mm$ on Y - line. Ulnar artery was measured at hypothenar area, and it's coordinates were $-20.4{\pm}6.3mm$ on X - line, and $30.6{\pm}7.4mm$ on Y - line. Conclusions: Anatomically superficial palmar arch can be divided into a complete and an incomplete type. Each of them can be subdivided into 4 types. The deep palmar arch is less variable than the superficial palmar arch. We believe these values of the study will be used for the vascular surgery of the hand using the endoscope and robot in the future.

Effects of Organic Iron Supplementation on Growth Performance and Body Composition in Broiler Chicks (유기철의 첨가가 육계의 성장과 체조성에 미치는 영향)

  • 양철주;우간바야르;나상준;고석영;위화영;정대균;김해영
    • Korean Journal of Poultry Science
    • /
    • v.31 no.2
    • /
    • pp.93-100
    • /
    • 2004
  • This study was conducted to evaluate the effect of organic iron supplemented to feed for broilers. One hundred forty four Ross broiler chicks were assigned to 6 treatments: control containing 80mg Fe from iron sulfate per kg diet(FE-80), FE-160 (control multiplied two times), YM-80 containing 80mg Fe from yeast mutant, YM-160 (YM-80 multiplied two times), YF-80 containing 80mg Fe from ferritin containing yeast, YF-160 (YF-80 multiplied two times) in the experiment. Each treatment had four replications of 6 birds each. The weight gain of the YM-160 was significantly higher (P<0.05) than that of the control (FE-80). The YM and YF in the serum cholesterol level were significantly higher (P<0.05) than the control. In the cholesterol level of carcass, although the control (FE-80) was highest and the YM and YF were very low; however, there were no significant differences among treatments. In the iron level of carcass, the control (FE-80) showed the lowest level among treatments; the YM and YF were significantly higher (P<0.05) than the control. In conclusion, the supplementation with organic iron to broiler chicks improve productivity. We also expect the possibility on chicken meat with reinforcing iron.

A Characteristics and Improvement of Thermal Environment in Summer of Protected Horticulture Complex Using CFD Simulation (CFD 시뮬레이션을 이용한 시설원예단지 여름철 외부 열환경 특성 및 개선방안)

  • Son, Jin-Kwan;Kong, Min-Jae;Choi, Deuggyu;Kang, Dong-Hyeon;Park, Min-Jung;Yun, Sung-Wook;Lee, Seungchul;Lee, Si-Young
    • Journal of Korean Society of Rural Planning
    • /
    • v.24 no.3
    • /
    • pp.73-86
    • /
    • 2018
  • Agricultural or rural landscape provides various ecosystem services. However, the ecosystem services function is declining due to various environmental problems such as climate change, land use change, stream intensification, non-point pollution and garbage. The A1B scenario predicts that the mean air temperature of South Korea will rise $3.8^{\circ}C$ degrees celsius in 2100. Agricultural sector is very vulnerable to climate change, so it must be thoroughly predicted and managed. In Korea, the facility horticulture complex is 54,051ha in 2016 and is the 3rd largest in the world(MAFRA, 2014). Facilities of horticultural complexes are reported to cause problems such as groundwater decrease, vegetation and insects diversity reduction, landscapes damage and garbage increase, compared with the existing land use paddy fields. Heat island phenomenon associated with climate change is also accelerated by the high heat absorption of horticultural sites. Therefore, we analyzed the heat island phenomenon occurring in the facility of horticultural complex in Korea. As an improvement measurement, I examined how much air temperature is reduced by putting the channel and the open space. In the case of the Buyeo area, the Computational Fluid Dynamics (CFD) simulation was analyzed for the average summer temperature distribution in the current land use mode at $38.9^{\circ}C$. As an improvement measurement, CFD simulation after 10% of 6m water channel was found to have an effect of lowering the summer temperature of about $2.7^{\circ}C$ compared with the present average of $36.2^{\circ}C$. In addition, CFD simulations after analyzing 10% of the open space were analyzed at $34.7^{\circ}C$, which is $4.2^{\circ}C$ lower than the present. For the Jinju area, CFD simulations were analyzed for the average temperature of summer at $37.8^{\circ}C$ in the present land use pattern. As an improvement measure, CFD simulations after 10% of 6m water channel were found to have an effect of lowering the summer temperature of about $2.6^{\circ}C$ compared to the current average of $35.2^{\circ}C$. In addition, CFD simulations after analyzing 10% of the open space were analyzed at $33.9^{\circ}C$, which is $3.9^{\circ}C$ lower than the present. It can be said that the effect of summer temperature drop in open space and waterway has been proven. The results of this study are expected to be reflected in sustainable agriculture land use and used as basic data for government - level policy in land use planning for climate change.

Measurement of Image Quality According to the Time of Computed Radiography System (시간에 따르는 CR장비의 영상의 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Hwang, Sun-Kwang;Lee, Ik-Pyo;Kim, Ki-Won;Jung, Jae-Yong;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.365-374
    • /
    • 2015
  • The regular quality assurance (RQA) of X-ray images is essential for maintaining a high accuracy of diagnosis. This study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) of a computed radiography (CR) system for various periods of use from 2006 to 2015. We measured the pre-sampling MTF using the edge method and RQA 5 based on commission standard international electro-technical commission (IEC). The spatial frequencies corresponding to the 50% MTF for the CR systems in 2006, 2009, 2012 and 2015 were 1.54, 1.14, 1.12, and $1.38mm^{-1}$, respectively and the10% MTF for 2006, 2009, 2012, and 2015 were 2.68, 2.44, 2.44, and $2.46mm^{-1}$, respectively. In the NPS results, the CR systems showed the best noise distribution in 2006, and with the quality of distributions in the order of 2015, 2009, and 2012. At peak DQE and DQE at $1mm^{-1}$, the CR systems showed the best efficiency in 2006, and showed better efficiency in order of 2015, 2009, and 2012. Because the eraser lamp in the CR systems was replaced, the image quality in 2015 was superior to those in 2009 and 2012. This study can be incorporated into used in clinical QA requiring performance and evaluation of the performance of the CR systems.

Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료의 다양한 EPID 영상 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Cho, Jeong-Hee;Lee, Jea-Hee;Jung, Jae-Yong;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.451-461
    • /
    • 2015
  • In megavoltage (MV) radiotherapy, delivering the dose to the target volume is important while protecting the surrounding normal tissue. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using an edge block in megavoltage X-ray imaging (MVI). We used an edge block, which consists of tungsten with dimensions of 19 (thickness) ${\times}$ 10 (length) ${\times}$ 1 (width) $cm^3$ and measured the pre-sampling MTF at 6 MV energy. Various radiation therapy (RT) devices such as TrueBeam$^{TM}$ (Varian), BEAMVIEW$^{PLUS}$ (Siemens), iViewGT (Elekta) and Clinac$^{(R)}$iX (Varian) were used. As for MTF results, TrueBeam$^{TM}$(Varian) flattening filter free(FFF) showed the highest values of $0.46mm^{-1}$ and $1.40mm^{-1}$ for MTF 0.5 and 0.1. In NPS, iViewGT (Elekta) showed the lowest noise distribution. In DQE, iViewGT (Elekta) showed the best efficiency at a peak DQE and $1mm^{-1}DQE$ of 0.0026 and 0.00014, respectively. This study could be used not only for traditional QA imaging but also for quantitative MTF, NPS, and DQE measurement for development of an electronic portal imaging device (EPID).

Analysis of Bacterial Contamination on Surface of General Radiography Equipment and CT Equipment in Emergency Room of Radiology (영상의학과 응급실내의 일반촬영장비와 전산화단층촬영장비 표면에서의 세균 오염에 관한 분석)

  • Hong, Dong-Hee;Kim, Hyeong-Gyun
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.421-427
    • /
    • 2016
  • We aim to offer basic materials about infection management through conducting bacterial contamination test about general radiography equipment and CT equipment installed in ER of three general hospitals with 100 sickbeds or more located in Gyeongsangbuk-do Province, and suggest management plan. It had been conducted from 1st December 2015 to 31st December, and objects were general radiography equipment and CT equipment of emergency room located in Gyeongsangbuk-do Province. For general radiography equipment, sources were collected from 4 places such as upper side of control box which employees use most, upper side of exposure button, whole upper side of table which is touching part of patient's skin, upper side of stand bucky's grid, and where patients put their jaws on. For CT equipment, sources were collected from 3 places such as upper side of control box which radiography room employees use most, X-ray exposure button, whole upper side of table which is touching part of patient's skin, and gantry inner. Surface contamination strain found at general radiography equipment in emergency room of radiology are Providencia stuartii(25%), Stenotrophomonas maltophilia(18%), Enterobacter cloacae(8%), Pseudomonas species(8%), Staphylococcus epidermidis(8%), Gram negative bacilli(8%), and ungrown bacteria at incubator after 48 hours of incubation (67%) which is the biggest. Most bacteria were found at upper side of stand bucky-grid and stand bucky of radiology's general radiography equipment, and most sources of CT equipment were focused at patient table, which means it is contaminated by patients who have various diseases, and patients who have strains with decreased immunity may get severe diseases. Thus infection prevention should be made through 70% alcohol disinfection at both before test and after test.