• 제목/요약/키워드: wban

검색결과 181건 처리시간 0.027초

Towards Key Issues of Disaster Aid based on Wireless Body Area Networks

  • Liu, Jianqi;Wang, Qinruo;Wan, Jiafu;Xiong, Jianbin;Zeng, Bi
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제7권5호
    • /
    • pp.1014-1035
    • /
    • 2013
  • With recent advances in wireless communication and low-power miniaturized biomedical sensor and semiconductor technologies, wireless body area networks (WBAN) has become an integral part of the disaster aid system. Wearable vital sign sensors can track patients' status and location, thus enhancing disaster rescue efficiency. In the past few years, most of the literatures in the area of disaster aid system based on WBAN have focused on issues concerning wireless sensor design, sensor miniaturization, energy efficiency and communication protocols. In this paper, we will give an overview of disaster aid, discuss about the types of network communication as well as outline related issues. We will emphasize on analyzing six key issues in employing the disaster aid system. Finally, we will also highlight some of the challenges that still need to be addressed in the future in order to help the disaster aid system be truly and widely accepted by the public.

ISRMC-MAC: Implementable Single-Radio, Multi-Channel MAC Protocol for WBANs

  • Cho, Kunryun;Jeon, Seokhee;Cho, Jinsung;Lee, Ben
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권3호
    • /
    • pp.1052-1070
    • /
    • 2016
  • Wireless Body Area Networks (WBANs) have received a lot of attention as a promising technology for medical and healthcare applications. A WBAN should guarantee energy efficiency, data reliability, and low data latency because it uses tiny sensors that have limited energy and deals with medical data that needs to be timely and correctly transferred. To satisfy this requirement, many multi-radio multi-channel MAC protocols have been proposed, but these cannot be implemented on current off-the-shelf sensor nodes because they do not support multi-radio transceivers. Thus, recently single-radio multi-channel MAC protocols have been proposed; however, these methods are energy inefficient due to data duplication. This paper proposes a TDMA-based single-radio, multi-channel MAC protocol that uses the Unbalanced Star+Mesh topology to satisfy the requirements of WBANs. Our analytical analysis together experiments using real sensor nodes show that the proposed protocol outperforms existing methods in terms of energy efficiency, reliability, and low data latency.

Novel UWB Transceiver for WBAN Networks: A Study on AWGN Channels

  • Zhao, Chengshi;Zhou, Zheng;Kwak, Kyung-Sup
    • ETRI Journal
    • /
    • 제32권1호
    • /
    • pp.11-21
    • /
    • 2010
  • A novel ultra-wideband (UWB) transceiver structure is presented to be used in wireless body area networks (WBANs). In the proposed structure, a data channel and a control channel are combined into a single transmission signal. In the signal, a modulation method mixing pulse position modulation and pulse amplitude modulation is proposed. A mathematical framework calculating the power spectrum density of the proposed pulse-based signal evaluates its coexistence with conventional radio systems. The transceiver structure is discussed, and the receiving performance is investigated in the additive white Gaussian noise channel. It is demonstrated that the proposed scheme is easier to match to the UWB emission mask than conventional UWB systems. The proposed scheme achieves the data rate requirement of WBAN; the logical control channel achieves better receiving performance than the logical data channel, which is useful for controlling and maintaining networks. The proposed scheme is also easy to implement.

Efficient Interference Cancellation Scheme for Wireless Body Area Network

  • Bae, Jung-Nam;Choi, Young-Hoon;Kim, Jin-Young;Kwon, Jang-Woo;Kim, Dong-In
    • Journal of Communications and Networks
    • /
    • 제13권2호
    • /
    • pp.167-174
    • /
    • 2011
  • In this paper, we propose and simulate an efficient interference cancellation scheme with an optimal ordering successive interference cancellation (SIC) algorithm for ultra wideband (UWB)/multiple-input-multiple-output (MIMO) systems in a wireless body area network (WBAN). When there are several wireless communication devices on a human body, multiple access interference (MAI) usually occurs. To mitigate the effect of MAI and achieve additional diversity gain, we utilize SIC with an optimal ordering algorithm. A zero correlation duration (ZCD) code with robust MAI capability is employed as a spread code for UWB systems in a multi-device WBAN environment. The performance of the proposed scheme is evaluated in terms of the bit error rate (BER). Simulation results confirm that the BER performance can be improved significantly if the proposed interference cancellation scheme and the ZCD code are jointly employed.

WBAN을 기반으로 한 OpenEMed의 PIDS를 이용한 Kerberos 인증 (A study on WBAN based Kerberos Authentication System using PIDS of OpenEMed)

  • 이재광;김영혁;임일권;이재필;이재광
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2012년도 춘계학술발표대회
    • /
    • pp.734-737
    • /
    • 2012
  • 인체 무선망이란 USN(Ubiquitous Sensor Network)을 통해 환자의 생체 정보를 실시간으로 수집하는 환경이다. 이를 기반으로 원격지에서 생체 정보를 전달 받는 시스템이 u-RPMS(USN Remote Patient Monitoring System)이다. u-RPMS에서 실시간으로 환자의 정보들이 발생하는데 이때 실시간으로 발생한 정보들은 공유가 불가피하다. 환자의 생체 정보는 생명과 연결되기 때문에 공유할 때 안전이 중요하다. 하지만 u-RPMS에서는 무선 통신으로 동작하기 때문에 보안에 취약하며, 이를 보안하기 위해서 서버와 DB(Data Base) 사이에 인증 서버를 통해서 해결 할 것을 제시한다. 본 연구에서는 인체 무선망을 기반으로 해서 모듈화 된 오픈 소스 원격진료 플랫폼인 OpenEMed의 개인 확인 서비스(PIDS, Personal Identification Service)를 이용해 네트워크를 기반으로 한 Kerberos 인증을 제안한다.

WSN 을 위한 초저전력 MICS RF 송수신기 기술 개요 및 설계 기법 (Ultra-Low Power MICS RF Transceiver Design for Wireless Sensor Network)

  • 김규원;김유정;한정환
    • 반도체공학회 논문지
    • /
    • 제2권1호
    • /
    • pp.9-16
    • /
    • 2024
  • 본 논문에서는 무선 센서 네트워크를 위한 생체이식형 초저전력 MICS RF 트랜시버 설게에 대해 다룬다. 400 MHz MICS 표준은 WBAN 무선 센서 시스템 구현을 위해, 인체 내 전파적 특성 및 주변 네트워크와의 간접 최소화하며 고려되었다. 본 논문은 MICS 표준에 부합하는 시스템 및 송수신기 설계를 위한 link budget 및 다양한 송수신 아키텍쳐, 초저전력 송수신기 회로기법을 포함한다.

Medical BAN 기술 동향

  • 이형수
    • 한국전자파학회지:전자파기술
    • /
    • 제19권5호
    • /
    • pp.104-109
    • /
    • 2008
  • MBAN(Medical Wireless Body Area Network)은 인체 내부에 이식한 장비를 인체 외부에서 모니터링하는 인체 이식형 의료 분야와 인체 표면이나 $3{\sim}5$미터내 인체의 주변에서 일어나는 신체 부착형 의료분야로 정의할 수 있다. 본 고에서는 기존 MBAN으로 사용하고 있던 무선장비들에 대한 각국의 기술 개발 동향을 분석하였으며, 인체 내부와 외부에서의 가장 큰 특성인 인체 전파 특성에 대해서도 분석해 보았다. 그리고 IEEE에서 표준화 작업중인 WBAN(Wireless Body Area Network)의 개념과 추진 상황과 더불어 현재 검토 중인 주파수 대역에 대해서 분석하였다.

웨어러블 컴퓨팅을 위한 서비스 인프라 구조 (Service Infrastructure of Wearable Computing)

  • 한동원;박준석;조일연
    • 대한인간공학회지
    • /
    • 제24권1호
    • /
    • pp.43-46
    • /
    • 2005
  • The future information technologies and service paradigm will move from PC, the general purpose desktop computing environment, to the next-generation PC that provides information any where, any time, and any device. The next-generation PC such as wearable computers are specialized to the human-centric functionalities and always-on connected services. In this study, service infrastructure of wearable computing with WBAN(Wearable Body Area Network) was suggested for the ubiquitous computing environment.

실시간 의료 모니터링 서비스를 위한 질의 색인 구조 (Design of a query index procedure for real-time monitoring for medical services)

  • 최옥주;맹보연;이민수
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2009년도 추계학술발표대회
    • /
    • pp.225-226
    • /
    • 2009
  • 최근 센서를 이용한 의료 분야로의 유비쿼터스 시스템 및 서비스 연구가 활발히 진행되고 있다. 그러나 의료 분야 서비스의 기본적 전제인 WBAN 환경에서의 기존의 모니터링 시스템은 매우 수동적이다. 이를 개선해 스트림 데이터에 대해 보다 효율적인 모니터링 시스템을 구축하기 위한, 우선 순위를 표현하기 위한 큐(Queue)와 각 속성에 대한 질의로 구성된 레벨 트리(Level Tree)로 이어지는 질의 색인 구조에 대해 논하고자 한다.

하이브리드 앱을 이용한 모바일 헬스케어 시스템 구현에 관한 연구 (A Study on the Implementation of Mobile Healthcare System using Hybrid App)

  • 조양현;김성완;정필성
    • 한국정보통신학회논문지
    • /
    • 제17권2호
    • /
    • pp.503-514
    • /
    • 2013
  • 모바일 헬스케어는 정보 통신 기술과 바이오 기술을 융합하여 언제 어디서나 건강과 생활을 관리하고자 하는 새로운 형태의 서비스이다. 이를 위해서는 생체신호 계측 기술인 WBAN과 모바일 디바이스를 이용한 데이터 분석 및 모니터링 기술이 필수적이다. 통상 모바일 애플리케이션은 모바일 플랫폼의 특성상 호환성 부재로 해당 플랫폼에 맞게 재개발해야 한다. 본 논문에서는 플랫폼의 이질성을 극복하고 다양한 모바일 장치와의 호환성을 가진 유비쿼터스 헬스케어 모니터링 시스템을 구성하기 위해 하이브리드 앱을 기반으로 게이트웨이 기능과 모니터링 기능을 가지는 모바일 헬스케어 시스템을 구성하였다. 제안 시스템은 센서를 이용한 센서 구성 부분, 모바일 디바이스를 이용한 모바일 구성 부분, 생체 정보를 모니터링하는 모니터링 구성 부분, 측정된 생체 데이터 축적 및 관리를 목적으로 구성된 서버 구성 부분으로 나누어 시스템을 구성하였다.