• Title/Summary/Keyword: waveforms

Search Result 1,062, Processing Time 0.03 seconds

Metric Defined by Wavelets and Integra-Normalizer (웨이브렛과 인테그라-노말라이저를 이용한 메트릭)

  • Kim, Sung-Soo;Park, Byoung-Seob
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.7
    • /
    • pp.350-353
    • /
    • 2001
  • In general, the Least Square Error method is used for signal classification to measure distance in the $l^2$ metric or the $L^2$ metric space. A defect of the Least Square Error method is that it does not classify properly some waveforms, which is due to the property of the Least Square Error method: the global analysis. This paper proposes a new linear operator, the Integra-Normalizer, that removes the problem. The Integra-Normalizer possesses excellent property that measures the degree of relative similarity between signals by expanding the functional space with removing the restriction on the functional space inherited by the Least Square Error method. The Integra-Normalizer shows superiority to the Least Square Error method in measuring the relative similarity among one dimensional waveforms.

  • PDF

Adoption of MFER and HL7 Standard for Shared Electronic Medical Record (공유 전자의무기록을 위한 MFER과 HL7 표준 적용)

  • Kim, Hwa-Sun;Park, Chun-Bok;Hong, Hae-Sook;Cho, Hune
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.501-506
    • /
    • 2008
  • Medical environments incorporate complex and integrated data networks to transfer vast amounts of patient information, such as images, waveforms, and other digital data. To assure interoperability of images, waveforms and patient data, health level seven(HL7) was developed as an international standard to facilitate the communication and storage of medical data. We also adopted medical waveform description format encoding rule(MFER) standard for encoding waveform biosignal such as ECG, EEG and so on. And, the study converted a broad domain of clinical data on patients, including MFER, into a HL7 message, and saved them in a clinical database in hospital. According to results obtained in the test environment, it was possible to acquire the same HL7 message and biosignal data as ones acquired during transmission. Through this study, we might conclude that the proposed system can be a promising model for electronic medical record system in u-healthcare environment.

Low Voltage Impulse Test for Power Electric Instrunment Precaution Diagonsis Techniques (전력기기 예방진단 기술을 위한 저전압 충격시험)

  • Kwak, Hee-Ro;Kim, Jae-Chul;Kwan, Tae-Won;Yoon, Young-Beum;Son, Jin-Geun;Yun, Ji-Yong
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.281-285
    • /
    • 1991
  • In this paper, response characteristics by applying impulse into transformer windings in order to precaution diagonosis of power electric instrument are studied. A sample oilless transformer, an aging transformer and a good transformer are slected for models. The experimented results show that for testing the windings distortion and impedanced change of transformer the LVI method are suitable. Also, variation characteristic of output waveforms at time and frequency domain in order to efficient analysis is discussed. The results response that waveforms at frequency domain is very higher resolution at time domain.

  • PDF

Development of the Algorithm for Discriminating Faults from Variation using Wavelet Transform (웨이블릿 변환을 이용한 고장과 Variation의 유형 구분 알고리즘 개발)

  • Seo, Hun-Chul;Lee, Soon-Jeong;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1460-1466
    • /
    • 2011
  • This paper proposes the algorithm for discriminating faults from the variation due to the operation of non-linear components to prevent the mal-operation of protection relay in the distribution system. An IEEE 13 node test feeder is modeled to analyze the characteristics of the fault and each variation using EMTP-RV. Simulations with various operating conditions of transformers, non-linear loads, and unbalanced loads are performed using the test feeder model. Based on simulation results, the wavelet transform is adopted to analyze the current waveforms from the faults and variations to find out the differences between them and the algorithm for discriminating faults from the variation is proposed. The proposed algorithm is verified by using the current waveforms simulated in the KEPCO's distiribution system and IEEE 13 node test feeder.

Failure of Earth Leakage Breaker and Power Quality Analysis in Office Buildings (사무용 빌딩에서의 누전차단기 오동작과 전력품질 분석)

  • Lee, Sang-Ick;Yoo, Jae-Geun;Jeong, Jong-Wook;Lim, Yong-Bae;Jeon, Jeong-Chay
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.211-216
    • /
    • 2004
  • This paper presented a actual conditions on a false-tripping of ELB(Electrical Leakage Breaker) and an assessment of the harmonics due to non-linear electronic equipment such as personal computers, printers, fax machines, and test equipments in several office buildings. Actual conditions on a failure of ELB were surveyed and analyzed by making up a question to safety managers of in office buildings. Also, power quality measurements such as harmonic currents, voltage and current waveforms and current imbalance were made at various office buildings where nuisance tripping of ELB is often occurred. The results of this study can be used in making decisions regarding cause of ELB trip and operating md tripping characteristics test of ELB when subjected to distorted current waveforms.

  • PDF

A study on the dynamic characteristic of voltage and current in a feeder system in case of cause contact loss on driving an electrical railway vehicle (전기차량 주행 중 이선상태에 따른 급전계통의 전압, 전류 동특성 연구)

  • Kim, Jae-Moon;Park, Young;Kim, Yang-Su;Lee, Jong-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2215-2216
    • /
    • 2011
  • In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to electrical railway vehicle is investigated from an electrical response point of view. To analysis voltage and current waveforms by induced contact loss phenomenon on driving electrical railway vehicle, a hardware Simulator which considered contact loss between contact wire and the pantograph as well as contact wire deviation is developed. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system. Throughout prototype simulator and contact wire and catenary wire experiments, it is confirmed that current waveforms is distorted by contact loss phenomenon and in case of driving electrical railway vehicle.

  • PDF

Torque Characteristics by the Inductance Profiles of a Switched Reluctance Motor (Switched Reluctance Motor에서 인덕턴스 프로필에 따른 토오크 특성)

  • Kong, Gwan-Sik;Park, Han-Woong;Ahn, Jin-Woo;Hwang, Young-Moon
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.597-599
    • /
    • 1992
  • A calculation method for predicting the instantaneous torques by the inductance profiles of a switched reluctance motor (SRM) is presented. The method considers saturation and nonlinearities in the magnetic circuits. The inductance of SRM varies complex according to the input current waveforms and rotor position angle, thus the accurate calculation technique is needed to estimate the inductance value at arbitary input current and rotor position angle. This paper describes how the inductance profiles influence the torque produced by the input current of SRM and, proposes a calculation technique of the permeabilities, reluctances, current waveforms and torques of a 6/4 3-phase SRM.

  • PDF

Shorted-Turn Diagnosis Test for Generator Rotor Windings using Low Voltage Pulse Signal (저전압 펄스신호를 이용한 발전기 회전자 턴단락 진단)

  • Lee, Young-Jun;Kim, Byung-Rae;Whang, Young-Ha
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2019_2020
    • /
    • 2009
  • A recurrent surge oscillograph(RSO) test was performed at the Taean thermal power plant on #5 turbine generator. The test was conducted using a rotor reflectometer and digital oscilloscope. A DC voltage step is applied to each end of the rotor winding in turn. Each reflected wave, at the input end of the winding, is monitored and the two waveforms are superimposed automatically and monitored on a single channel oscilloscope. As the half windings in a rotor are identical, the two waveforms monitored at each end of the rotor will also be identical for a healthy winding. A winding with a fault will cause different voltages to be monitored at the two ends.

  • PDF

Characteristics of Elastic Waves Generated by Fatigue Crack Penetration and Growth in an Aluminum Plate

  • Ahn, Seok-Hwan;Nam, Ki-Woo
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.11
    • /
    • pp.1599-1607
    • /
    • 2003
  • The characteristics of elastic waves emanated from crack initiation in 6061 aluminum alloy subjected to fatigue loading are investigated through experiments. The objective of the study is to determine the differences in the properties of the signals generated from fatigue test and also to examine if the sources of the waves could be identified from the temporal and spectral characteristics of the acoustic emission (AE) waveforms. The signals are recorded using nonresonant, flat, broadband transducers attached to the surface of the alloy specimens. The time dependence and power spectra of the signals recorded during the tests were examined and classified according to their special features. Six distinct types of signals were observed. The waveforms and their power spectra were found to be dependent on the crack propagation stage and the type of fracture associated with the signals. The potential application of the approach in health monitoring of structural components using a network of surface mounted broadband sensors is discussed.

Improvement of Chip Thickness Model in 2-flutes Slot End Milling (2날 엔드밀 슬롯 가공시 칩두께 모델의 개선)

  • Lee Dong-Kyu;Lee Ki-Yong;Lee Kune-Woo;Oh Won-Zin;Kim Jeong-Suk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.1
    • /
    • pp.32-38
    • /
    • 2005
  • Generally, cutting force models use a sin function method to calculate chip thickness. In slot end milling, the error from a sin function method is much bigger than other machining because a tool rotation angle in cutting is much larger. Thus in this paper, a new method to calculate chip thickness was suggested and evaluated. In a new method, tool position data according to tool rotation are checked and stored so that it is possible correct chip thickness is calculated. Cutting force waveforms simulated from a sin function method and a new method and measured waveforms from experiments were compared and error percentages were obtained. Finally, a new method had good results for simulating cutting force in slot end milling.