• Title/Summary/Keyword: waveform analysis

Search Result 745, Processing Time 0.027 seconds

A Study on Vibration Analysis During the Slab Dismantling Using the Mechanical Dismantling Method (기계식 해체 공법을 적용한 슬래브 해체 시 발생하는 진동 해석 연구)

  • Noh, You-Song;Suk, Chul-Gi;Park, Hoon
    • Explosives and Blasting
    • /
    • v.39 no.4
    • /
    • pp.1-11
    • /
    • 2021
  • In this study, the vibration data were obtained to analyze the vibration generated during dismantling of slab using the mechanical dismantling method. The obtained vibration data were classified according to the attachment device and then the waveform and dominant frequency analysis were performed. And the correlation was analyzed by the different methods of measuring the distance between the work section and the measurement point. As a result of the waveform analysis for each attachment device, there was little change in the phase of the vibration waveform and only the change in amplitude, which is the magnitude of the vibration velocity. And as a result of frequency analysis, the frequency band was lower when using a crusher method than a braker method and frequency band were close of the natural frequency of the structure to be dismantled. As a result of the correlation analysis, the separation distance was estimated a higher correlation when evaluated as the path through which the vibration propagates along the structure frame than the straight distance between the measurement point and the working section.

Numerical Analysis of Effect of Waveform Micropile on Foundation Underpinning During Building Vertical Extension Remodeling (수치해석을 통한 수직증축 리모델링시 파형 마이크로파일의 보강효과 분석)

  • Wang, Cheng-Can;Jang, Youngeun;Kim, Seok-Jung;Han, Jin-Tae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.2
    • /
    • pp.335-344
    • /
    • 2019
  • Micropiles are widely used for foundation underpinning to enhance bearing capacity and reduce settlement of existing foundation. In this study, the main objective is to evaluate underpinning performance of a newly developed micropile called waveform micropile for foundation underpinning during vertical extension. Finite element method (FEM) was used to evaluate the underpinning performance of waveform micropile in terms of load-settlement response of underpinned foundation and load sharing behavior. For comparison, underpinning effects of three conventional micropiles with different lengths were also discussed in this study. Numerical results of load-settlement response for single pile demonstrated that bearing capacity and axial stiffness of waveform micropiles were higher than those of conventional micropiles because of the effect of shear keys of waveform micropiles. When additional loads 20 %, which is according to design loads of the vertical extension, were applied to the underpinned foundation, load sharing capacity of waveform micropile was 40 % higher than conventional micropile at the same size. The waveform micropile also showed better underpinning performance than the conventional micropile of length 1~1.5 times of waveform micropile.

Contamination Characteristics of Polymer Insulator using High Frequency Current Transformer (HF-CT센서를 이용한 고분자애자의 오손특성)

  • Park, Jae-June
    • The Journal of Information Technology
    • /
    • v.8 no.4
    • /
    • pp.1-7
    • /
    • 2005
  • Investigations of high frequency current transformer(HF-CT) waveform characteristics of the surface leakage on kaolin polluted EPDM polymer insulators have been performed. This work is part of a program aimed at examining the potential for HF-CT waveform characteristics analysis to provide information about the environment contaminants and environment condition of polymer insulators. The investigation reported examined the HF-CT waveform characteristics at high frequencies. The use of high frequency measurements for on-line applications reduces electrical inference. This work was peformed utilizing HF-CT to monitor of surface polluted discharge. It was found that HF-CT waveform frequency spectrum, magnitude depend on importantly the duration of the surface discharge activity.

  • PDF

Feeding Behaviors of Bemisia tabaci (Gennadius) (Hemiptera: Aleyrodidae) and Changing of Feeding Behaviors to Cyantraniliprole (EPG를 이용한 담배가루이(Bemisia tabaci)의 섭식행동과 Cyantraniliprole에 대한 섭식변화)

  • Kwon, Hye-Ri;Youn, Young-Nam
    • Korean Journal of Agricultural Science
    • /
    • v.41 no.2
    • /
    • pp.119-124
    • /
    • 2014
  • Feeding behaviors of the sweet potato whitefly, Bemisia tabaci, and changing of their feeding behaviors were recorded and analyzed with an Electrical Penetration Graph (EPG) analysis against cyantraniliprole. The characteristic patterns of feeding behaviors investigated were as follows; NP (non probing), pathway phase waveform, waveform of feeding xylem. In results, B. tabaci did not almost feeding the phloem. And It was not appeared potential drop during recording time. It was predominantly indicated pathway activity waveform and waveform of xylem feeding. After treatment of cyantraniliprole with recommended concentrations to tomato plants, EPG waveforms were recorded during 3 hours. Cyantraniliprole treatment showed longer time to first feeding xylem than untreated (P=0.043). It was showed shorter duration of first feeding xylem than untreated (P=0.017). And it was showed longer NP (non-probing) time than untreated. Consequently, It was supposed that cyantraniliprole was effect of anti-feeding or avoidance to B. tabaci.

On a Pitch Alteration Method Compensated with the Spectrum for High Quality Speech Synthesis (스펙트럼 보상된 고음질 합성용 피치 변경법)

  • 문효정
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1995.06a
    • /
    • pp.123-126
    • /
    • 1995
  • The waveform coding are concerned with simply preserving the wave shape of speech signal through a redundancy reduction process. In the case of speech synthesis, the wave form coding with high quality are mainly used to the synthesis by analysis. However, because the parameters of this coding are not classified as either excitation and vocal tract parameters, it is difficult to applying the waveform coding to the synthesis by rule. In this paper, we proposed a new pitch alteration method that can change the pitch period in waveform coding by using scaling the time-axis and compensating the spectrum. This is a time-frequency domain method that is preserved in the phase components of the waveform and that has a little spectrum distortion with 2.5% and less for 50% pitch change.

  • PDF

Analysis of the Chip Waveforms for LPI Communication

  • Maing, Jun-Ho;Ryu, Heung-Gyoon;Lee, Dae-Il
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.2
    • /
    • pp.63-67
    • /
    • 2004
  • DAM(Delay-And-Multiplier) intercept receiver usually detects the symbol rate of the transmitted DS spread spectrum signal for the feature extraction. It is important for secure communication to reduce the normalized output signal-to-noise ratio that is generated at the DAM intercept receiver as a measure of detectability. In this paper, several kinds of chip waveforms are novelly analyzed for LPI(Low-Probability of Intercept) communication against DAM intercept receiver. Consequently, it is shown that the rectangular chip waveform shows the best LPI performance in the bandwidth of 2/$T_c$TEX>, 4/$T_c$TEX>, and 6/$T_c$TEX>/. Except the rectangular waveform, kaiser chip waveform show better LPI performance than the other waveforms in the bandwidth of 4/$T_c$TEX> and 6/$T_c$TEX>.

Copper Oxide Growing Characteristics of PVC Insulated Wire and Application to the Fire Investigation (비닐절연전선의 산화물 성장 특성과 화재조사에의 적용)

  • Kim, Hyang-Kon;Choi, Chung-Seog;Kim, Dong-Ook;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.1
    • /
    • pp.37-44
    • /
    • 2007
  • This paper describes characteristics for copper oxide growth of polyvinyl chloride(PVC) insulated wires by series arc. In this experiment, 600V IV wires were used, and characteristics of oxide growth and ignition process were analyzed in case load was 300W, 460W and 600W, respectively. In the result of experiment, covering materials were molten, carbonized and ignited, whereas, oxidized materials were grown in conducting material. During copper oxide was growing, contact voltages and power dissipations increased. When there is copper oxide growth, the waveform of current showed sinusoidal waveform, and the waveform of voltage showed modified waveform. Oxidized materials were heated at about $905^{\circ}C$, surface structure showed irregular shapes, and cross-section showed multiple cracks. And, the results of this experiment were applied to the fire cause analysis of fire evidence collected at the fire scene.

Optimal Harmonic Stepped Waveform Technique for Solar Fed Cascaded Multilevel Inverter

  • Alexander, S.Albert;Thathan, Manigandan
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.261-270
    • /
    • 2015
  • In this paper, the Optimal Harmonic Stepped Waveform (OHSW) method is proposed in order to eliminate the selective harmonic orders available at the output of cascaded multilevel inverter (CMLI) fed by solar photovoltaic (SPV). This technique is used to solve the harmonic elimination equations based on stepped waveform analysis in order to obtain the optimal switching angles which in turn reduce the Total Harmonic Distortion (THD). The OHSW method considers the output voltage waveform as four equal symmetries in each half cycle. In the proposed method, a solar fed fifteen level cascaded multilevel is considered where the magnitude of six numbers of harmonic orders is reduced. A programmable pulse generator is developed to carry the switching angles directly to the semiconductor switches obtained as a result of OHSW analysis. Simulations are carried out in MATLAB/Simulink in which a separate model is developed for solar photovoltaic which serves as the input for cascaded multilevel inverter. A 3kWp solar plant with multilevel inverter system is implemented in hardware to show the effectiveness of the proposed system. Based on the observation the OHSW method provides the reduced THD thereby improving power quality in renewable energy applications.