• Title/Summary/Keyword: waveform analysis

Search Result 745, Processing Time 0.026 seconds

A study on characteristics of blast vibration waveform by vibration time history analysis (진동이력분석을 응용한 발파 진동파형의 특성에 관한 연구)

  • 김진수;임한욱
    • Tunnel and Underground Space
    • /
    • v.9 no.1
    • /
    • pp.36-47
    • /
    • 1999
  • For cautious controlled blasting, it is necessary to understand characteristics of the blasting vibration. In this study, a series of tests were carried out to investigate the several characteristics of blasting vibration waveform by vibration time history analysis. Separation between impulse vibration and free vibration from blasting vibration, duration time, effects of overlap of free vibration upon the level of vibration and changes of waveform according to increase of charge weight per delay etc. were studied with waveform analysis.

  • PDF

Non-Intrusive Healthcare System for Estimation of Vascular Condition in IP-Enabled Wireless Network (IP 기반 무선네트워크에서의 혈관상태 평가를 위한 무구속 헬스케어 시스템)

  • Jung, Sang-Joong;Kwon, Tae-Ha;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.76-83
    • /
    • 2013
  • A real-time wireless monitoring and analysis methods using the wearable PPG sensor to estimate cardiovascular condition is studied for ubiquitous healthcare service. A small size and low-power consuming wearable photoplethysmogram (PPG) sensor is designed as a wrist type device and connected with the IP node assigned its own IPv6 address. The measured PPG waveform in the IP node is collected and transferred to a central server PC through the IP-enabled wireless network for storage and analysis purposes. A monitoring and analysis program is designed to process the accelerated plethysmogram (APG) waveform by applying the second order derivatives to analyze systolic waves as well as heart rate variability analysis from the measured PPG waveform. From our results, the features of cardiovascular condition from individual's PPG waveform and estimation of vascular compliance by the comparison of APG-aging index (AI) and ratio of LF/HF are demonstrated.

Study of Spectral Doppler Waveform Interpretation and Nomenclature in Peripheral Artery (말초 동맥 분광 도플러 파형 해석 및 명명법에 대한 고찰)

  • Ji, Myeong-Hoon;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.649-660
    • /
    • 2022
  • In 1959, Satomura used spectral Doppler ultrasound to express the velocity of red blood cells according to time change, and Kato defined a zero-base line that could tell the direction of blood flow, making it possible to know the direction of blood flow. This became the basis for the widely used classifications of Triphasic, Biphasic, and Monophasic. However, the above classification has limitations that confuse users with the meaning and timing of use in a clinical environment. As a result, the American Society for Vascular Medicine (SVM) and the Society for Vascular Ultrasound (SVU) A consensus document on Doppler waveform analysis was declared by the joint committee. This study tried to review this consensus and to suggest nomenclature and modifiers that can be used in the domestic vascular ultrasound clinical field. The joint committee formed by SVM and SVU recommended that the use of the triphasic waveform and the biphasic waveform be used as a multiphasic waveform rather than being used due to the ambiguity of interpretation. In addition, it was agreed to name the hybrid-type waveform, which is a monophasic and high-resistance waveform, which has always been a problem of interpretation in a clinical environment, as an intermediate resistive waveform. In addition, in order to increase the communication efficiency between the interpreter and the sonographer, waveform analysis was classified into a main descriptor and a modifier, and it was recommended to use a single nomenclature by unifying various synonyms. It is expected that this literature review will provide accurate arterial spectral Doppler waveform interpretation and an agreed-upon nomenclature to radiologists performing vascular ultrasound examination in clinical practice, and will be utilized as basic data that can contribute to the improvement of public health.

Fault Current Waveform Analysis of a Flux-Lock Type SFCL According to LC Resonance Condition of Third Winding

  • Lim, Sung-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.213-217
    • /
    • 2008
  • The flux-lock type superconducting fault current limiter(SFCL) can apply the magnetic field into the high-$T_C$ superconducting(HTSC) element by adopting the magnetic field coil in its third winding. To apply the magnetic field into the HTSC element effectively, the capacitor for LC resonance is connected in series with the magnetic field coil. However, the current waveform of third winding for the application of the magnetic field is affected by the LC resonance condition for the frequency of the source voltage and can affect the waveform of the limited fault current. In this paper, the current waveform of the third winding in the flux-lock type SFCL according to LC resonance condition during a fault period was analyzed. From the differential equation for its electrical circuit, the current equation of the third winding was derived and described with the natural frequency and the damping ratio as design parameters. Through the analysis according to the design parameters of the third winding, the waveform of the limited fault current was confirmed to be influenced by the current waveform of the third winding and the design condition for the stable fault current limiting operation of this SFCL was obtained.

On A Pitch Alteration using the Waveform Symmetry with Time - Frequency Conversion (시간 - 주파수 변환에 의한 파형 대칭 피치변경법)

  • 박형빈
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06c
    • /
    • pp.147-150
    • /
    • 1998
  • In the case of speech synthesis, the waveform coding method with high quality is mainly used to the synthesis by analysis. Because the parameters of this coding method are not classified as both excitation and vocal tract parameters, it is difficult to apply the waveform coding method to the synthesis by rule. Thus, in order to apply the waveform coding method to the synthesis by rule, a pitch alteration is required for the prosody control. In the speech synthesis method by the conventional PSOLA technique, applying symmetric window function to asymmetric speech waveform, it occurs the unbalance phenomenon of energy according to the overlapped degree of pitch interval adjustment. In this paper to overcome the unbalance phenomenon of energy, we proposed a new method that can convert asymmetric waveform to symmetric one by time-frequency conversion. As a result, we can obtain an average spectrum distortion ratio with 6.38% according to the pitch alteration ratio.

  • PDF

On Altering the Pitch of Speech Signals in Waveform Coding -(Altering Method by the LPC and the Pitch Halving)- (음성 파형코딩의 음원피치 변경에 관한 연구 - LPC와 주기반분법에 의한 피치변경법 -)

  • 민경중
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1991.06a
    • /
    • pp.45-49
    • /
    • 1991
  • In area of the speech synthesis, the waveform coding with high quality are mainly used to the synthesis by analysis. However, it is difficult to applying the waveform coding to the synthesis by rule, because the parameters of this coding are not classified as either excitation parameters and vocal tract parameters. In this paper, we proposed a new pitch change method that can alter the pitch periods in the waveform coding. The proposed method expands the pitch period by the LPC synthesis method, and then the period is compressed by the waveform halving technique. Thus, it is possible that the waveform coding is carried out the synthesis by rule in speech processing.

  • PDF

The Low Probability of Intercept RADAR Waveform Based on Random Phase and Code Rate Transition for Doppler Tolerance Improvement (도플러 특성 개선을 위한 랜덤 위상 및 부호율 천이 기반 저피탐 레이다 파형)

  • Lee, Ki-Woong;Lee, Woo-Kyung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.11
    • /
    • pp.999-1011
    • /
    • 2015
  • In modern electronic warfare, RADAR is under constant threat of ECM(Electronic Counter Measures) signals from nearby jammers. The conventional linear frequency modulated(Linear-FM) waveform is easy to be intercepted to estimate its signal parameters due to its periodical phase transition. Recently, APCN(Advanced Pulse Compression Noise) waveform using random amplitude and phase transition was proposed for LPI(Low probability of Intercept). But random phase code signals such as APCN waveform tend to be sensitive to Doppler frequency shift and result in performance degradation during moving target detection. In this paper, random phase and code rate transition based radar waveform(RPCR) is proposed for Doppler tolerance improvement. Time frequency analysis is carried out through ambiguity analysis to validate the improved Doppler tolerance of RPCR waveform. As a means to measure the vulnerability of the proposed RPCR waveform against LPI, WHT(Wigner-Hough Transform) is adopted to analyze and estimate signal parameters for ECCM(Electronic Counter Counter Measures) application.

The Comparison of Glottal Area Waveform between Normal Person and Patient with Vocal Lesions (정상인과 후두질환 환자에서 Glottal Area Waveform의 차이에 관한 연구)

  • Yoo, Young-Sam;Rosen, Clark A.
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.16 no.1
    • /
    • pp.5-9
    • /
    • 2005
  • Background and Objectives : Glottal area waveform(GAW) shows the plot of glottal area versus time through the 1 cycle. This study is designed to see how it can be applied to laryngeal patients. Material and Methods : A GAW analysis was peformed on 11 patients before and after surgery and 22 persons without laryngeal problems were recruited for control. Acoustic and aerodynamic analysis with VHI(voice handicap index) evaluation were performed. Results. Significant changes in baseline offset, gross closing rate and VHI were observed postoperatively. Other parameters were changed but insignificant. Conclusion : GAW maybe used to evaluate patient with voice problems.

  • PDF

Design of Cost-Effective Driving Waveform Based on Vt Close Curve Analysis in AC Plasma Display Panel

  • Cho, Byung-Gwon;Tae, Heung-Sik;Ito, Kazuhiro;Song, Jun-Weon;Lee, Myoung-Kyu;Kim, Sang-Chul;Jung, Nam-Sung;Lee, Kwang-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.251-254
    • /
    • 2005
  • A new driving waveform was proposed to reduce the cost in PDP-TV based on Vt close curve by eliminating the common (X) board under the conventional 42-inch panel structure. Due to the serious misfiring problem during a sustain-period when applying the new driving waveform, the wall voltage was measured and analyzed after the reset-period using Vt close curve. As a result of adopting the proposed driving waveform designed using Vt close curve analysis, the cost of PDP module could reduce compared with the conventional PDP module without any misfiring discharge.

  • PDF

Sinusoidal Back-EMF of Vernier Permanent Magnet Machines

  • Li, Dawei;Qu, Ronghai
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.1
    • /
    • pp.40-47
    • /
    • 2014
  • Sinusoidal back-EMF waveform of vernier Permanent Magnet (PM) machines is analyzed in this paper. An analytical expression of Electromotive Force (EMF) of electric machines including vernier machines is developed to analyze EMF harmonics, and the effect of vernier PM machine pole ratio, the ratio of number of rotor poles to stator poles, on the EMF waveform. Moreover, this paper represents several Finite Element Analysis (FEA) models to verify the analysis based on the proposed expression, and the effect of tooth width ratio, which is the ratio of tooth width to tooth pitch, on back-EMF of vernier PM machines, and optimal tooth width ratio is obtained and verified by FEA. Finally, this paper makes comparisons between EMF waveform of vernier PM machines and that of traditional PM machines from the point of view of analytical EMF expression.