• Title/Summary/Keyword: waveform

Search Result 2,463, Processing Time 0.034 seconds

Nondestructive Evaluation and Microfailure Mechanisms of Single Fibers/Brittle Cement Matrix Composites using Electro-Micromechanical Technique and Acoustic Emission (Electro-Micromechanical 시험법과 Acoustic Emission을 이용한 단섬유/시멘트 복합재료의 미세파괴 메커니즘과 비파괴적 평가)

  • 박종만;이상일;김진원;윤동진
    • Composites Research
    • /
    • v.14 no.3
    • /
    • pp.18-31
    • /
    • 2001
  • Interfacial and microfailure properties of the modified steel, carbon and glass fibers/cement composites were investigated using electro-pullout test under tensile and compressive tests with acoustic emission (AE). The hand-sanded steel composite exhibited higher interfacial shear strength (IFSS) than the untreated and even neoalkoxy zirconate (Zr) treated steel fiber composites. This might be due to the enhanced mechanical interlocking, compared to possible hydrogen or covalent bonds. During curing process, the contact resistivity decreased rapidly at the initial stage and then showed a level-off. Comparing to the untreated case, the contact resistivity of either Zr-treated or hand-sanded steel fiber composites increased to the infinity at latter stage. The number of AE signals of hand-sanded steel fiber composite was much more than those of the untreated and Zr-treated cases due to many interlayer failure signals. AE waveforms for pullout and frictional signals of the hand-sanded composite are larger than those of the untreated case. For dual matrix composite (DMC), AE energy and waveform under compressive loading were much higher and larger than those under tensile loading, due to brittle but well-enduring ceramic nature against compressive stress. Vertical multicrack exhibits fur glass fiber composite under tensile test, whereas buckling failure appeared under compressive loading. Electro-micromechanical technique with AE can be used as an efficient nondestructive (NDT) method to evaluate the interfacial and microfailure mechanisms for conductive fibers/brittle and nontransparent cement composites.

  • PDF

Comparative Study on Acoustic Characteristics of Vocal Fold Paralysis and Benign Mucosal Disorders of Vocal Fold (성대마비와 양성 성대점막질환의 음향학적 특성비교)

  • Kong, Il-Seung;Cho, Young-Ju;Lee, Myung-Hee;Kim, Jong-Seung;Yang, Yun-Su;Hong, Ki-Hwan
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.18 no.2
    • /
    • pp.122-128
    • /
    • 2007
  • This study aims to analyze the voices of the patients with voice disorders including vocal fold paralysis, vocal fold cyst and vocal nodule/polyp in the aspect of acoustic phonetics. This study intends to collect subsidiary acoustic data in order to make a speech treatment and an standardization of vocal disorders. Subjects and Methods: The subjects of this study were 64 adult patients who underwent indirect laryngoscopy and laryngostroboscopy, and were diagnosed as vocal fold paralysis, vocal fold cyst or vocal nodule/polyp. Experimental group consisted of 20 patients who were diagnosed as vocal fold paralysis, 21 patients who were diagnosed as vocal fold cyst and had the average age of 42.0 $({\pm}10.03)$ ; and 23 patients who were diagnosed as vocal nodule/polyp and had the average age of 40.9 $({\pm}13.75)$. For the methodology of this study, the patients listed above were asked to sit in a comfortable position at intervals of 10cm apart from the patient's mouth and a microphone, and subsequently to phonate a vowel sound /e/ for the maximum phonation time with natural tone and vocal volume then the sound was directly inputted on a computer. During recording, sampling rate was set to 44,100Hz and the 1-second area corresponding to stable zone except the first and the last stage of waveform of the vowel sound /e/ vocalized by the individual patients was analyzed. Results: First, there was no statistically significant difference in jitter and shimmer between vocal fold paralysis and vocal fold cyst, while there was highly statistically significant difference in them between vocal fold paralysis and vocal nodule/polyp. Second, looking into the mean values obtained from NNE, HNR and SNR results associated with noise ratio, the disease showing the most abnormal characteristics was vocal fold paralysis, followed by cyst and nodule/polyp in order. For NNE, there was statistically significant difference between vocal nodule/polyp, and cyst or paralysis. In other words, it was found that the NNE of vocal nodule/polyp was weaker than that of cyst or paralysis. Similarly, HNR and SNR also showed the same characteristics; there was statistically significant difference between vocal fold paralysis and vocal fold cyst or nodule/polyp, and HNR and SNR values of vocal fold paralysis were lower than those of vocal fold cyst or nodule/polyp. Conclusion: For vocal fold paralysis, the abnormal values of acoustic parameters associated with frequency, amplitude and noise ratio were statistically significantly higher than those of vocal fold cyst and nodule/polyp. This finding suggests that the voices of the patients with vocal fold paralysis are the most severely injured due to less stability of vocal fold movement, asymmetry and incomplete glottic closure. In addition, there was no statistically significant difference in the acoustic parameters of tremor among vocal fold paralysis, vocal fold cyst and vocal nodule/polyp. Further studies need to ascertain reasonable acoustic parameters with various vocal disorders as well as to clarify the correlation between acoustics-based objective tools and subjective evaluations.

  • PDF

Evaluation and interpretation of the effects of heterogeneous layers in an OBS/air-gun crustal structure study (OBS/에어건을 이용한 지각구조 연구에서 불균질층의 영향에 대한 평가와 해석)

  • Tsuruga, Kayoko;Kasahara, Junzo;Kubota, Ryuji;Nishiyama, Eiichiro;Kamimura, Aya;Naito, Yoshihiro;Honda, Fuminori;Oikawa, Nobutaka;Tamura, Yasuo;Nishizawa, Azusa;Kaneda, Kentaro
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.1
    • /
    • pp.1-14
    • /
    • 2008
  • We present a method for interpreting seismic records with arrivals and waveforms having characteristics which could be generated by extremely inhomogeneous velocity structures, such as non-typical oceanic crust, decollement at subduction zones, and seamounts in oceanic regions, by comparing them with synthetic waveforms. Recent extensive refraction and wide-angle reflection surveys in oceanic regions have provided us with a huge number of high-resolution and high-quality seismic records containing characteristic arrivals and waveforms, besides first arrivals and major reflected phases such as PmP. Some characteristic waveforms, with significant later reflected phases or anomalous amplitude decay with offset distance, are difficult to interpret using only a conventional interpretation method such as the traveltime tomographic inversion method. We find the best process for investigating such characteristic phases is to use an interactive interpretation method to compare observed data with synthetic waveforms, and calculate raypaths and traveltimes. This approach enables us to construct a reasonable structural model that includes all of the major characteristics of the observed waveforms. We present results here with some actual observed examples that might be of great help in the interpretation of such problematic phases. Our approach to the analysis of waveform characteristics is endorsed as an innovative method for constructing high-resolution and high-quality crustal structure models, not only in oceanic regions, but also in the continental regions.

Reproducibility of Regional Pulse Wave Velocity in Healthy Subjects

  • Im Jae-Joong;Lee, Nak-Bum;Rhee Moo-Yong;Na Sang-Hun;Kim, Young-Kwon;Lee, Myoung-Mook;Cockcroft John R.
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.4 no.2
    • /
    • pp.19-24
    • /
    • 2006
  • Background: Pulse wave velocity (PWV), which is inversely related to the distensibility of an arterial wall, offers a simple and potentially useful approach for an evaluation of cardiovascular diseases. In spite of the clinical importance and widespread use of PWV, there exist no standard either for pulse sensors or for system requirements for accurate pulse wave measurement. Objective of this study was to assess the reproducibility of PWV values using a newly developed PWV measurement system in healthy subjects prior to a large-scale clinical study. Methods: System used for the study was the PP-1000 (Hanbyul Meditech Co., Korea), which provides regional PWV values based on the measurements of electrocardiography (ECG), phonocardiography (PCG), and pulse waves from four different sites of arteries (carotid, femoral, radial, and dorsalis pedis) simultaneously. Seventeen healthy male subjects with a mean age of 33 years (ranges 22 to 52 years) without any cardiovascular disease were participated for the experiment. Two observers (observer A and B) performed two consecutive measurements from the same subject in a random order. For an evaluation of system reproducibility, two analyses (within-observer and between-observer) were performed, and expressed in terms of mean difference ${\pm}2SD$, as described by Bland and Altman plots. Results: Mean and SD of PWVs for aorta, arm, and leg were $7.07{\pm}1.48m/sec,\;8.43{\pm}1.14m/sec,\;and\;8.09{\pm}0.98m/sec$ measured from observer A and $6.76{\pm}1.00m/sec,\;7.97{\pm}0.80m/sec,\;and\;\7.97{\pm}0.72m/sec$ from observer B, respectively. Between-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.14{\pm\}0.62m/sec,\;0.18{\pm\}0.84m/sec,\;and\;0.07{\pm}0.86m/sec$, and the correlation coefficients were high especially 0.93 for aortic PWV. Within-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.01{\pm}0.26m/sec,\;0.02{\pm}0.26m/sec,\;and\;0.08{\pm}0.32m/sec$ from observer A and $0.01{\pm}0.24m/sec,\;0.04{\pm}0.28m/sec,\;and\;0.01{\pm}0.20m/sec$ from observer B, respectively. All the measurements showed significantly high correlation coefficients ranges from 0.94 to 0.99. Conclusion: PWV measurement system used for the study offers comfortable and simple operation and provides accurate analysis results with high reproducibility. Since the reproducibility of the measurement is critical for the diagnosis in clinical use, it is necessary to provide an accurate algorithm for the detection of additional features such as flow wave, reflection wave, and dicrotic notch from a pulse waveform. This study will be extended for the comparison of PWV values from patients with various vascular risks for clinical application. Data acquired from the study could be used for the determination of the appropriate sample size for further studies relating various types of arteriosclerosis-related vascular disease.

  • PDF

The Effects on Dose Distribution Characteristics by Changing Beam Tuning Parameters of Digital Linear Accelerator in Medicine (의료용 디지털 선형가속기의 빔조정 인자변화가 선량분포특성에 미치는 영향)

  • 박현주;이동훈;이동한;권수일;류성렬;지영훈
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.17-22
    • /
    • 1999
  • INJ-I, INJ-E, PFN, BMI, and PRF were selected among the various factors which constitute a digital linear accelerator to find effects on the dose distribution by changing current and voltage within the permitted scale which Mevatron automatically maintained. We measured the absorbed dose using an ion chamber, analyzed the waveform of beam output using an oscilloscope, and measured symmetry and flatness using a dosimetry system. An RFA plus (Scanditronix, Sweden) device was used as a dosimetry system. Then an 0.6cc ion chamber (PR06C, USA), an electrometer (Capintec192, USA), and an oscilloscope (Tektronix, USA) were employed to measure the changes on the dose distribution characteristics by changing the beam-tuning parameters. When the currents and the voltages of INJ-I, INJ-E, PFN, BMI, and PRF were modified, we were able to see the notable change on the dose rate by examining the change of the output pulse using the oscilloscope and by measuring them using the ion chamber. However, the results of energy and flatness graph from RF A plus were almost identical. The factors had fine differences: INJ-I, INJ-E, PFN, BMI, and PRF had 0.01∼0.02% differences in D10/D20, 0.1∼0.2 % differences in symmetry, and 0.1∼0.4% differences in flatness. Since Mevatron controlled itself automatically to keep the reference value of the factor, it was not able to see large differences in the dose distribution. There were fine differences on the dose rate distribution when the voltage and the currents of the digitized factors were modified Nonetheless, a basic operational management information was achieved.

  • PDF

Age-related Changes of the Finger Photoplethysmogram in Frequency Domain Analysis (연령증가에 따른 지첨용적맥파의 주파수 영역에서의 변화)

  • Nam, Tong-Hyun;Park, Young-Bae;Park, Young-Jae;Shin, Sang-Hoon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.1
    • /
    • pp.42-62
    • /
    • 2008
  • Objectives: It is well known that some parameters of the photoplethysmogram (PPG) acquired by time domain contour analysis can be used as markers of vascular aging. But the previous studies that have been performed for frequency domain analysis of the PPG to date have provided only restrictive and fragmentary information. The aim of the present investigation was to determine whether the harmonics extracted from the PPG using a fast Fourier transformation could be used as an index of vascular aging. Methods: The PPG was measured in 600 recruited subjects for 30 second durations, To grasp the gross age-related change of the PPG waveform, we grouped subjects according to gender and age and averaged the PPG signal of one pulse cycle. To calculate the conventional indices of vascular aging, we selected the 5-6 cycles of pulse that the baseline was relatively stable and then acquired the coordinates of the inflection points. For the frequency domain analysis we performed a power spectral analysis on the PPG signals for 30 seconds using a fast Fourier transformation and dissociated the harmonic components from the PPG signals. Results: A final number of 390 subjects (174 males and 216 females) were included in the statistical analysis. The normalized power of the harmonics decreased with age and on a logarithmic scale reduction of the normalized power in the third (r=-0.492, P<0.0001), fourth (r=-0.621, P<0.0001) and fifth harmonic (r=-0.487, P<0.0001) was prominent. From a multiple linear regression analysis, Stiffness index, reflection index and corrected up-stroke time influenced the normalized power of the harmonics on a logarithmic scale. Conclusions: The normalized harmonic power decreased with age in healthy subjects and may be less error prone due to the essential attributes of frequency domain analysis. Therefore, we expect that the normalized harmonic power density can be useful as a vascular aging marker.

  • PDF

Synthetic Application of Seismic Piezo-cone Penetration Test for Evaluating Shear Wave Velocity in Korean Soil Deposits (국내 퇴적 지반의 전단파 속도 평가를 위한 탄성파 피에조콘 관입 시험의 종합적 활용)

  • Sun, Chang-Guk;Kim, Hong-Jong;Jung, Jong-Hong;Jung, Gyung-Ja
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.3
    • /
    • pp.207-224
    • /
    • 2006
  • It has been widely known that the seismic piezo-cone penetration test (SCPTu) is one of the most useful techniques for investigating the geotechnical characteristics such as static and dynamic soil properties. As practical applications in Korea, SCPTu was carried out at two sites in Busan and four sites in Incheon, which are mainly composed of alluvial or marine soil deposits. From the SCPTu waveform data obtained from the testing sites, the first arrival times of shear waves and the corresponding time differences with depth were determined using the cross-over method, and the shear wave velocity $(V_S)$ profiles with depth were derived based on the refracted ray path method based on Snell's law. Comparing the determined $V_S$ profile with the cone tip resistance $(q_t)$ profile, both trends of profiles with depth were similar. For the application of the conventional CPTu to earthquake engineering practices, the correlations between $V_S$ and CPTu data were deduced based on the SCPTu results. For the empirical evaluation of $V_S$ for all soils together with clays and sands which are classified unambiguously in this study by the soil behavior type classification index $(I_C)$, the authors suggested the $V_S-CPTu$ data correlations expressed as a function of four parameters, $q_t,\;f_s,\;\sigma'_{v0}$ and $B_q$, determined by multiple statistical regression modeling. Despite the incompatible strain levels of the downhole seismic test during SCPTu and the conventional CPTu, it is shown that the $V_S-CPTu$ data correlations for all soils, clays and sands suggested in this study is applicable to the preliminary estimation of $V_S$ for the soil deposits at a part in Korea and is more reliable than the previous correlations proposed by other researchers.

Cerebellar Activation Related to Various Tasks Using fMRI (다양한 임무 부여시 기능적 자기공명영상에서 관찰된 소뇌의 활성화)

  • Hwang, Seung-Bae;Kwak, Hyo-Sung;Lee, Sang-Yong;Jin, Gong-Yong;Han, Young-Min;Kim, Young-Kon;Chung, Gyung-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.47-53
    • /
    • 2009
  • Purpose : Although it's been known for half a century that unique structures have evolved in the cerebellum and they then became greatly enlarged in the human brain, the function of these structures still remains unknown. The purpose of this study was to assess cerebellar activation during motor, sensory, word generation, listening comprehension, and working memory tasks with using functional magnetic resonance imaging (fMRI). Materials and Methods : Eleven healthy right-handed subjects (Male: female, 6:5, mean age: 27.4years) were imaged on a Siemens 1.5T scanner. Whole brain functional maps were acquired using BOLD EPI sequences in the axial plane. Each paradigm consisted of five epochs of activation vs. the control condition. The activation tasks consisted of left finger complex movement, sensory stimulation of the left hand, word generation, listening comprehension, and working memory tasks. The reference function was a boxcar waveform. The activation maps were thresholded at p = 0.001. SPM 5 evaluated the activated areas and responses within the cerebellum. Results : Cerebellar activation was observed on motor task, word generation task, and working memory task. There were 949 activated areas and the mean fitted and adjusted response was 0.68 during the motor task. There were 319 activated areas and the mean fitted and adjusted response was 0.15 during the word generation task. There were 330 activated areas and the mean fitted and adjusted response was 0.26 during the working memory task. Conclusion : Our results suggest that the cerebellum is involved in a variety of functional tasks, including motor, word generation, and working memory tasks. However, during the motor task, the cerebellum showed a large activated area and a high response. Cerebellar function can be evaluated by fMRI.

  • PDF

A Study on Real-Time Defect Detection Using Ultrasound Excited Thermography (초음파 서모그라피를 이용한 실시간 결함 검출에 대한 연구)

  • Cho, Jai-Wan;Seo, Yong-Chil;Jung, Seung-Ho;Jung, Hyun-Kyu;Kim, Seung-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.4
    • /
    • pp.211-219
    • /
    • 2006
  • The UET(ultrasound excited thermography) for the ,eat-time diagnostics of the object employs an infrared camera to image defects of the surface and subsurface which are locally heated using high-frequency putted ultrasonic excitation. The dissipation of high-power ultrasonic energy around the feces of the defects causes an increase In temperature. The defect's image appears as a hot spot (bright IR source) within a dark background field. The UET for nondestructive diagnostic and evaluation is based on the image analysis of the hot spot as a local response to ultrasonic excited heat deposition. In this paper the applicability of VET for fast imaging of defect is described. The ultrasonic energy is injected into the sample through a transducer in the vertical and horizontal directions respectively. The voltage applied to the transducer is measured by digital oscilloscope, and the waveform are compared. Measurements were performed on four kinds of materials: SUS fatigue crack specimen(thickness 14mm), PCB plate(1.8 mm), CFRP plate(3 mm) and Inconel 600 plate (1 mm). A high power ultrasonic energy with pulse durations of 250ms Is injected into the samples in the horizontal and vertical directions respectively The obtained experimental result reveals that the dissipation loss of the ultrasonic energy In the vertical injection is less than that in the horizontal direction. In the cafe or PCB, CFRP, the size of hot spot in the vortical injection if larger than that in horizontal direction. Duration time of the hot spot in the vertical direction is three times as long as that in the horizontal direction. In the case of Inconel 600 plate and SUS sample, the hot spot in the horizontal injection was detected faster than that in the vertical direction

Effect of the Configuration of Contact Type Textile Electrode on the Performance of Heart Activity Signal Acquisition for Smart Healthcare (스마트 헬스케어를 위한 심장활동 신호 검출용 접촉식 직물전극의 구조가 센싱 성능에 미치는 영향)

  • Cho, Hyun-Seung;Koo, Hye-Ran;Yang, Jin-Hee;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Jeong-Hwan;Kwak, Hwy-Kuen;Ko, Yun-Su;Oh, Yun-Jung;Park, Su-Youn;Kim, Sin-Hye;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.63-76
    • /
    • 2018
  • The purpose of this study was to investigate the effect of contact type textile electrode structure on heart activity signal acquisition for smart healthcare. In this study, we devised six contact type textile electrodes whose electrode size and configuration were manipulated for measuring heart activity signals using computerized embroidery. We detected heart activity signals using a modified lead II and by attaching each textile electrode to the chest band in four healthy male subjects in a standing static posture. We measured the signals four times repeatedly for all types of electrodes. The heart activity signals were sampled at 1 kHz using a BIOPAC ECG100, and the detected original signals were filtered through a band-pass filter. To compare the performance of heart activity signal acquisition among the different structures of the textile electrodes, we conducted a qualitative analysis using signal waveform and size as parameters. In addition, we performed a quantitative analysis by calculating signal power ratio (SPR) of the heart activity signals obtained through each electrode. We analyzed differences in the performance of heart activity signal acquisition of the six electrodes by performing difference and post-hoc tests using nonparametric statistic methods on the calculated SPR. The results showed a significant difference both in terms of qualitative and quantitative aspects of heart activity signals among the tested contact type textile electrodes. Regarding the configurations of the contact type textile electrodes, the three-dimensionally inflated electrode (3DIE) was found to obtain better quality signals than the flat electrode. However, regarding the electrode size, no significant difference was found in performance of heart signal acquisition for the three electrode sizes. These results suggest that the configuration method (flat/3DIE), which is one of the two requirements of a contact type textile electrode structure for heart activity signal acquisition, has a critical effect on the performance of heart activity signal acquisition for wearable healthcare. Based on the results of this study, we plan to develop a smart clothing technology that can monitor high-quality heart activity without time and space constraints by implementing a clothing platform integrated with the textile electrode and developing a performance improvement plan.