• Title/Summary/Keyword: wave treatment

Search Result 566, Processing Time 0.028 seconds

Effect of Pain and Shoulder Joint Function on Extracorporeal Shock Wave Therapy of Patients with Frozen Shoulder (체외충격파 치료가 동결견 환자의 통증과 견관절 기능에 미치는 영향)

  • Cho, Nam-Jung;Park, Ji-Whan
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.13 no.2
    • /
    • pp.69-78
    • /
    • 2007
  • Purpose: The purpose of this study was to assess the effectiveness of Extracorporea Shock - Wave Therapy (ESWT) on the pain and improvement of shoulder joint function which is one of the available medical treatment in patients with frozen shoulder. Object and Methods: 26 patients with frozen shoulder, with 26 patients assigned to two groups; a control treatment group (n=12) and a ESWT application group (n=14). In the ESWT application group, the patients received general physical therapy, and then they received ESWT. In the control treatment group, the patients received only general physical therapy. These medical treatments was conducted total 6 time for 3 weeks. To investigate the effectiveness of the treatment after the each group's treatment. Pain was measured by Visual Analogue Scale (VAS) which is divided into 10 ranks and shoulder joint function was measured by CSA(Constant Shoulder Assessment scale). Results: 1. There was a statistical significance of measured by shoulder pain degree in both group but, the result of a ESWT application group shows more significance than that of a control treatment group. 2. There was a statistical significance of measured by CSA in both group but, the result of a ESWT application group shows more significance than that of a control treatment group. Conclusion: We think that treatment with General physical therapy and ESWT together for the patients with frozen shoulder is more effective and more safe method to shoulder joint function improvement and decrease of pain.

  • PDF

A Study on Cost-effective Treatment of Wastewater and Odor Reduction for Southeast Asian Market Entry

  • Jung, Min-Jae;Kim, Yong-Do;Kwon, Lee-Seung;Lee, Woo-Sic;Kwon, Woo-Taeg
    • The Journal of Industrial Distribution & Business
    • /
    • v.9 no.12
    • /
    • pp.23-29
    • /
    • 2018
  • Purpose - The purpose of this study is to apply a cost effective ultrasonic odor reduction method that generated micro-bubbles using ejector to the Southeast Asian wastewater market. Research design, data, and methodology - A leather maker located in Ansan-city, Gyunggi-do, South Korea was sampled from the collection tank to select experimental materials. Experimental setup consisted of circulating water tank-air ejector-ultrasonic device, and circulating wastewater. Sample analysis was performed by CODcr, T-N, T-P, and turbidity by the National Environmental Science Institute. Results - Experimental results show that it is most effective in removing odors when the frequency range of ultrasonic wave is 60~80 Khz and the output is 200 W. It showed that the concentration of complex odor dropped from a maximum of 14,422 times to a minimum of 120 times. Also, analysis of ammonia and hydrogen sulfide in specific odor substances has shown that they were reduced from 1.5 ppm to 0.4 ppm and from 0.6 ppm to 0.1 ppm, respectively. Conclusions - It is possible to shorten more than 12 hours in the treatment of micro-organisms. It can be seen that the processing time of odor after ultrasonic treatment in the pre-treatment facility is reduced by 25% when compared to the resultant micro-organisms after the chemical treatment, that is, the time of the bio-treatment of micro-organisms. Based on the results, it was confirmed that the pre-treatment method using the ultrasonic and the air ejector device of the experiment shows the effect of reducing the water pollutants and odor more effectively in a relatively short time than the conventional advanced oxidation method.

Loss of Facilitation in H-reflex: Implication as an Initial Abnormality and an Evidence of Central Nervous Involvement in Guillian-Bare Syndrome (H-반사 촉진의 소실: 길랑-바레 증후군의 초기 이상과 중추신경 침범의 증거로써의 의미)

  • Sung, Jung-Joon;Lee, Yoon-Jeong;Hong, Yoon-Ho;Chung, Young-Min;Lee, Kwang-Woo
    • Annals of Clinical Neurophysiology
    • /
    • v.4 no.2
    • /
    • pp.119-124
    • /
    • 2002
  • Background : Guillain-$Barr{\acute{e}}$ syndrome(GBS) is a neurologically emergent condition, leading to respiratory insufficiency without an early and appropriate treatment. Thus, the treatment of GBS requires early diagnosis but it is difficult due to the low sensitivity of laboratory tools in the initial stage. Hoffman reflex (H-reflex) and its facilitation by Jendrassik maneuver (JM) are sensitive tools evaluating the central circuit of motor system on the spinal cord level. The aim of this study is to test whether the change of H-reflex and F-wave under the JM is able to detect the early stage of GBS and whether GBS involves the central nervous system (CNS). Material and Methods : All 7 GBS patients who showed normal or nearly normal nerve conduction study were included. The facilitation of H-reflex and changes of F-wave were calculated by measuring the percent difference of H-reflex or F-wave amplitude under JM compared to basal H-reflex of F-wave amplitude. The changes of F-wave and H-reflex in the GBS patients were compared with them of 8 healthy controls. Results : The F-wave amplitudes of both healthy controls and GBS patients did not changed under the influence of JM ($102.4{\pm}24.9%$, $108.7{\pm}29.0%$ respectively). However, the facilitation of H-wave by JM in the GBS patients was absent ($98.8{\pm}5.8%$), even though the H-reflex amplitude I the healthy controls increased under the influence of JM ($124.8{\pm}12.1%$). Conclusions : The loss of H-reflex facilitation in GBS implies that this phenomenon might be the most early change detected in the electrophysiological study and support the early diagnosis, and that GBS might include lesion in the spinal motor CNS.

  • PDF

Experimental and numerical investigations on axial crushing of square cross-sections tube with vertical wave

  • Eyvazian, Arameh;Eltai, Elsadig;Musharavati, Farayi;Taghipoor, Hossein;Sebaey, T.A.;Talebizadehsardari, Pouyan
    • Steel and Composite Structures
    • /
    • v.36 no.2
    • /
    • pp.119-141
    • /
    • 2020
  • In this paper, wavy square absorbers were experimentally and numerically investigated. Numerical simulations were performed with LS-Dyna software on 36 wavy absorbers and their crushing properties were extracted and compared with the simple one. The effect of different parameters, including wave height, wave depth, and wave type; either internal or external on the crushing characteristics were also investigated. To experimentally create corrugation to validate the numerical results, a set of steel mandrel and matrix along with press machines were used. Since the initial specimens were brittle, they were subjected to heat treatment and annealing to gain the required ductility for forming with mandrel and matrix. The annealing of aluminum shells resulted in a 76%increase in ultimate strain and a 60% and 56% decrease in yield and ultimate stresses, respectively. The results showed that with increasing half-wave height in wavy square absorbers, the maximum force was first reduced and then increased. It was also found that in the specimen with constant diameter and half-wave depth, an increment in the half-wave height led to an initial increase in efficiency, followed by a decline. According to the conducted investigations, the lowe maximum force can be observed in the specimen with zero half-wave depth as compared to those having a depth of 1 cm.

Effects of bee venom acupuncture on heart rate variability, pulse wave, and cerebral blood flow for types of Sasang Constitution (봉약침 자극이 사상체질별 건강인의 심박변이도, 맥파, 뇌혈류에 미치는 영향)

  • Lee, Sang-Min;Kim, Koo;Oh, Seung-Yun;Kwon, Young-Mi;Joo, Jong-Cheon
    • Journal of Pharmacopuncture
    • /
    • v.12 no.1
    • /
    • pp.35-42
    • /
    • 2009
  • 1. Objectives To evaluate effects of bee venom acupuncture on cardiovascular system and differences according to each constitution. 2. Methods Heart rate variability, pulse wave and the velocity of cerebral blood flow were measured before bee venom acupuncture(BVA), right after and after 30 minuets, had been applied to 20 subjects. 3. Results 1. BVA did not have effects on measurement variables of heart rate variability. 2. BVA had effects on pulse wave, showing total time, radial augmentation index up and height of percussion wave, time to percussion wave, sum of pulse pressure down. 3. BVA did not have effects on the cerebral blood flow velocity when considering not Sasang Constitution. 4. Considering Sasang Constitution, BVA demonstrates different responses in time to preincisura wave, mean blood flow velocity, peak systolic velocity and end diastolic velocity. 4.Conclusion From those results, the following conclusions are obtained. Cause BVA alters pulse wave and makes differences in the cerebral blood flow velocity according to Sasang Constitution. Various methods of BVA treatment are needed considering Sasang Constitution.

Ultrasound-guided Exact Focusing of Extracorporeal Shock Wave Therapy for the Calcific Tendinitis of Gluteus Medius - A Case Report - (중둔건 석회화 건염의 초음파 유도하 정확한 조준에 의한 체외충격파치료 -증례 보고-)

  • Moon, Sang Ho;Lee, Song;Kim, Kwang Hai;Jeong, Jongpil;Hong, Seong Won
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.2
    • /
    • pp.94-98
    • /
    • 2012
  • Calcific tendinitis is characterized by inflammation around calcium hydroxyapatite crystal deposits. Minimally invasive extracorporeal shock wave therapy (ESWT) has been postulated to be an effective treatment option for treating calcific tendinitis. In clinical practice, shock waves usually are aimed at the painful area after palpation and not focused. It has been known that exact fluoroscopic focusing of ESWT at the calcific deposit for treatment of calcifying tendinopathy is highly effective. Ultrasound is a simple, inexpensive and radiation-free diagnostic tool that has been used to demonstrate tendinopathy including calcific tendinitis. However, focusing of shock wave under ultrasound is less well established. We present a patient in whom large calcific tendinitis of gluteus medius was completely resolved by exact focusing of ESWT by ultrasound with literature review.

  • PDF

Use of Guided Waves for Monitoring Material Conditions in Fossil-Fuel Power Plants (판파를 이용한 화력 발전 설비의 물성 평가)

  • Cho, Youn-Ho;Jung, Kyung-Sik;Lee, Jae-Sun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.6
    • /
    • pp.695-700
    • /
    • 2010
  • Material properties of the lock plate, which covers the gas-turbine blade, are studied using ultrasonic guided waves. The lock plate is a crucial part of a gas-turbine power plant. The wave velocity and attenuation coefficient are measured to investigate the changes in the material properties under three heat-treatment conditions. Compared to the destructive mechanical tests, the material characterization of Inconel X-750 can be performed more efficiently and nondestructively by using ultrasonic guided waves; this characterization helps identify the changes occurring in its elastic moduli and Poisson's ratio under different heat-treatment conditions. The wave velocity and hardness of Inconel X-750 are proportional to each other. This nondestructive technique for the measurement of material properties can be widely used in various industries to avoid catastrophic failure. It is also expected that the guided-wave technique can be applied as a new cost- and time-saving inspection tool for longer and wider inspection ranges.

Q-Switched Nd YAG's SHG conversion techniques for a skin diseased treatment (피부질환 치료를 위한 Q-Switched Nd:YAG의 SHG 변환기술)

  • Kim, Whi-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.6
    • /
    • pp.1141-1149
    • /
    • 2009
  • Pulse style Nd: YAG Laser is suitable in skin remaking treatment, in compliance with the ramp continuous oscillation until of course normal takeoff, the Q-switch and mode motive takeoff the takeoff form which is various is possible and it is coming to be widely used in microsurgery and skin remaking promotion. According to therapeutic objective very it is important to control a energy density. Control of energy density the method which controls the pulse repetition rate of Laser output is mainly used. From the research which it sees pulse style Nd: It will be able to control the pulse repetition rate of YAG, the 2nd harmonic occurrence Laser (second harmonic generation: SHG) with the energy part of the light-wave which is a footnote wave number will hold and nonlinear decision it propagates and is converted by energy of the light-wave which is a footnote wave number the actual condition which and it applies the second harmonic occurrence in compliance with a secondary nonlinearity it leads and until skin deep part therapeutic possibility is the thing it will be able to observe simply.

Effects of Isoflurane Anesthesia on Post-Anesthetic Sleep-Wake Architectures in Rats

  • Jang, Hwan-Soo;Jung, Ji-Young;Jang, Kwang-Ho;Lee, Maan-Gee
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.14 no.5
    • /
    • pp.291-297
    • /
    • 2010
  • The sleep homeostatic response significantly affects the state of anesthesia. In addition, sleep recovery may occur during anesthesia, either via a natural sleep-like process to occur or via a direct restorative effect. Little is known about the effects of isoflurane anesthesia on sleep homeostasis. We investigated whether 1) isoflurane anesthesia could provide a sleep-like process, and 2) the depth of anesthesia could differently affect the post-anesthesia sleep response. Nine rats were treated for 2 hours with $ad$ $libitum$ sleep (Control), sleep deprivation (SD), and isoflurane anesthesia with delta-wave- predominant state (ISO-1) or burst suppression pattern-predominant state (ISO-2) with at least a 1-week interval. Electroencephalogram and electromyogram were recorded and sleep-wake architecture was evaluated for 4 hours after each treatment. In the post-treatment period, the duration of transition to slow-wave-sleep decreased but slow wave sleep (SWS) increased in the SD group, but no sleep stages were significantly changed in ISO-1 and ISO-2 groups compared to Control. Different levels of anesthesia did not significantly affect the post-anesthesia sleep responses, but the deep level of anesthesia significantly delayed the latency to sleep compared to Control. The present results indicate that a natural sleep-like process likely occurs during isoflurane anesthesia and that the post-anesthesia sleep response occurs irrespective to the level of anesthesia.

Effects of Motor Learning Guided Laryngeal Motor Control Therapy for Muscle Misuse Dysphonia (운동학습이론에 기초한 발성운동조절법이 근오용성 발성장애의 음성에 미치는 효과)

  • Seo, In-Hyo;Lee, Ok-Bun;Lee, Sang-Joon;Chung, Phil-Sang
    • Phonetics and Speech Sciences
    • /
    • v.3 no.3
    • /
    • pp.133-140
    • /
    • 2011
  • Muscle misuse dysphonia (MMD) is defined as a behavioral voice disorder resulting from inappropriate contractions of intrinsic and/or extrinsic laryngeal muscles. The purpose of this study was to investigate the effect of motor learning guided laryngeal motor control therapy (MLG-LMCT) which is designed to improve an existing LMT and further the effective voice treatment on people with muscle misuse dysphonia. Forty-six people with MMD (M:F=16:30) participated in this study. The voice samples of the participants were recorded to investigate the effect of MLG-LMCT before and after the voice therapy. Voice samples were analyzed via electro-glotto-graph (EGG). Contact quotient (CQ), speed quotient (SQ), and waveform were reported. In addition, perceptual and acoustical evaluation were conducted to determine the change of voice improvement after treatment. The experimenter massaged the tensioned muscles around the neck. In order to find more proper phonation the experimenter showed the subjects their EGG wave forms as to whether or not they are moving the vocal folds to the appropriate position. Therefore, the EGG wave forms were used as a type of visual feedback. With the wave form, the experimenter helped subjects move the vocal folds and laryngeal muscles to find more proper voice production. The sensory stimuli from the experimenter gradually faded out. A paired dependent t- test revealed that there was significant differences in CQ between pre- and post-therapy. Perceptually, overall, rough, breathy, strain, and transition were significantly reduced. Acoustically, there were significant differences in Fo, jitter, shimmer, and NHR. After using MLG-LMCT, most of the subjects showed improvements in voice quality. The results from this study led us to the following conclusions: Motor learning guided laryngeal motor control therapy (MLG-LMCT) has reduces muscle misuse dysphonia. These results may occur because a visual feedback from EGG wave form can maintain the effect of the muscle tension reduction from laryngeal manual therapy. In case of people with MMD who reduced muscle tension from the therapy (LMT) but, not appropriately manipulating the location of larynx or adducting the vocal folds, MLG-LMCT might be an alternative therapy approach.

  • PDF