• 제목/요약/키워드: wave groups

검색결과 478건 처리시간 0.029초

Ellipsometry를 이용한 저 유전상수를 갖는 SiOCH박막의 광학특성 연구 (A Study of Optical Characteristics Correlated with Low Dielectric Constant of SiOCH Thin Films Through Ellipsometry)

  • 박용헌
    • 한국전기전자재료학회논문지
    • /
    • 제23권3호
    • /
    • pp.228-233
    • /
    • 2010
  • We studied the optical characteristics correlated with low dielectric constants of low-k SiOCH thin films through ellipsometry. The low-k SiOCH thin films were prepared by CCP-PECVD method using BTMSM(Bis-trimethylsilylmethane) precursors deposited on p-Si wafer. The Si-O-CHx, Si-O-Si, Si-CHx, CHx and Si-H bonding groups were specified by FTIR spectroscopic spectra, and the groups coupled with the nano-porous structural organic/inorganic hybrid-type of SiOCH thin films which has extremely low dielectric constant close to 2.0. The structural groups includes highly dense pore as well as ions in SiOCH thin films affecting to complex refraction characteristics of single layer on the p-Si wafer. The structural complexity originate the complex refractive constants of the films, and resulted the elliptical polarization of the incident linearly polarized light source of Xe-light source in the range from 190 nm to 2100 nm. Phase difference and amplitude ratio between s wave and p wave propagating through SiOCH thin film was studied. After annealing, the amplitude of p wave was reduced more than s wave, and phase difference between p and s wave was also reduced.

양백(GB14) 전침자극이 뇌파 변화에 미치는 영향 (Effect of Electroacupuncture at GB14 on Brain Activity)

  • 강태리
    • Korean Journal of Acupuncture
    • /
    • 제36권4호
    • /
    • pp.241-251
    • /
    • 2019
  • Objectives : The purpose of this study was to examine the effects of electroacupuncture at GB14, on brain activity assessed on an electroencephalogram(EEG). Methods : (1) Thirty-four healthy participants were randomly divided into two groups, receiving either real acupuncture or non-penetrating sham acupuncture at GB14. (2) EEG measurements were conducted simultaneously before and after a 5-minute electroacupuncture stimulation, and the differences in the resulting EEG parameters were compared between the test and control groups. Results : (1) Absolute power increased significantly in the theta-wave channel of the occipital region and in the entire alpha-wave channel. (2) Relative power decreased significantly in the theta-wave channels of the frontal and occipital regions. (3) Coherence decreased significantly in the theta- and beta-wave channels of the parietal and occipital regions, and increased significantly in the alpha-wave channels of most areas. Conclusions : This study shows that electroacupuncture stimulation at GB14 activates the alpha frequency band in particular.

Reciprocating 파일 시스템에서 Glide Path가 근관만곡도 유지에 미치는 영향 (The Effect of Glide Path on Canal Centering Ability in Reciprocating File System)

  • 장기철;김진우;조경모;박세희
    • 구강회복응용과학지
    • /
    • 제28권3호
    • /
    • pp.245-252
    • /
    • 2012
  • 본 실험은 왕복 회전 운동을 하는 단일 파일 시스템으로서 Reciproc과 WaveOne을 이용하였으며 glide path를 형성했을 때와 안 했을 때의 근관의 중심 변위율과 만곡도의 감소를 비교하여 새로운 단일 파일 시스템에서 glide path가 근관 성형 후 근관의 형태에 미치는 영향을 연구하였다. 총 40개의 모형 근관에 메틸렌블루 용액을 주입한 후 근관성형 전 이미지를 스캔 하였다. 네 개의 그룹으로 나누어졌으며 그룹 1은 PathFile (Dentsply Maillefer) #1, 2, 3 사용 후 R25 크기의 Reciproc 파일(VDW)을 사용하여 근관 성형하였다. 그룹 2는 PathFile 사용 없이 R25 크기의 Reciproc 파일을 사용하여 근관 성형하였다. 그룹 3은 PathFile #1, 2, 3 사용 후 Primary 크기의 WaveOne 파일 (Dentsply Maillerfer)을 이용하여 근관 성형하였다. 그룹 4는 PathFile 사용 없이 WaveOne 파일을 이용하여 근관 성형하였다. 파일은 모두 21 mm 길이를 사용했다. 각각의 파일을 위한 전기 모터로 Reciproc 파일은 VDW.SILVER motor (VDW), WaveOne 파일은 Waveone endo motor (Dentsply Maillefer)와 PathFile은 X-SMART (Dentsply Maillefer)를 사용하였다. 근관 성형을 마친 모형 근관을 다시 이미지 스캔 하였다. 성형 전, 후의 이미지를 Adobe Photoshop CS 3 (Adobe Systems Incorporated)을 이용하여 중첩하여 평가하였다. 중심 변위율은 Calhoun과 Montgomery에 의해 제안된 다음 공식을 사용하여 계산되었다:CR=|X1-X2|/Y. 실험 결과 근관의 만곡도가 감소하는 치근단 1, 2 mm level에서는 glide path의 형성에 따른 근관의 중심 변화율의 통계학적 유의성이 보이지 않았다. 근관 만곡 부위인 치근단 3, 4, 5 mm level에서는 glide path를 부여한 것이 통계학적으로 유의성 있게 낮은 중심 변위율을 보였다. 치근단 1 mm level에서는 Reciproc 파일이 유의성 있게 낮은 중심 변위율을 보였고, 치근단 1, 6 mm level을 제외한 모든 level에서 WaveOne 파일이 유의성 있게 낮은 중심 변위율을 보였다. 치근단 6 mm level에서는 Reciproc과 WaveOne의 차이는 관찰할 수 없었고 glide path를 형성한 그룹이 형성하지 않은 그룹에 비해 유의성 있게 낮은 중심 변위율을 보였다. 본 실험을 통해 만곡된 근관에서 근관 성형 전 glide path의 형성은 근관의 원래 형태를 유지하는데 필수적이며, 만곡된 근관에서는 WaveOne 파일 시스템의 선택이 근관의 원래 형태를 유지하는데 더 적절할 것으로 생각된다.

플러거 삽입깊이가 근관실러의 치근단 정출에 미치는 영향 (Influence of plugger penetration depth on the apical extrusion of root canal sealer in Continuous Wave of Condensation Technique)

  • 소호영;이영미;김광근;김기옥;김영경;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제29권5호
    • /
    • pp.439-445
    • /
    • 2004
  • Continuous Wave 가압법으로 근관충전시 플러거 삽입 깊이에 따른 근관실러의 치근단 정출을 평가하고자 직선형의 단근관 및 15번 크기의 치근단공을 가지는 발거된 40개의 치아에서 0.06 경사도 40번 크기가 되게 니켈-티타늄 전동화일인 $ProFile^{\circledR}$로 근관을 형성하고 플러거 삽입깊이를 근단 3, 5 또는 7 mm로 하여 System $B^{TM}$를 이용한 Continuous Wave 가압법 및 측방가압법으로 근관을 충전하였다. 치근단으로 정출된 근관실러의 무게를 측정하여 일원변량분석법과 Duncan's Multiple Range Test로 통계분석하였다. 플러거 삽입깊이 3 mm 또는 5 mm의 Continuous Wave 가압 충전군은 삽입깊이 7 mm 가압충전 군 및 측방가압 충전군에 비해 유의하게 많은 근관실러의 치근단 정출을 나타내었다 (p < 0.05). 그러나 플러거 삽입깊이 3 mm군과 5 mm군 사이 및 플러거 삽입깊이 7 mm Continuous Wave 가압군과 측방가압 군 사이에는 유의한 차이가 나타나지 않았다 (p > 0.05). 본 연구의 결과로 보아 Continuous Wave 가압법으로 근관충전시에는 플러거 삽입깊이가 깊을수록 근관실러의 치근단 정출이 많음을 알 수 있다.

계단지형을 지나는 파군에 의한 장파의 생성: 지배방정식 (Long Waves Generated by Short Wave Groups over a Step: Governing Equations)

  • 조용식
    • 한국수자원학회논문집
    • /
    • 제34권6호
    • /
    • pp.651-657
    • /
    • 2001
  • 본 논문에서는 단파의 파군이 계단형 지형을 통과할 때 발생하는 2차 장파를 이론적으로 연구하였다. 먼저, 수심 변화에 의한 단파의 회절을 해석하였으며, 다변수 섭동법을 이용하여 2차 장파의 지배방정식을 유도하였다. 2차 장파 방정식을 해석하여 서로 다른 속도로 진행하는 자유장파와 구속장파가 발생함을 보였다.

  • PDF

초음파가 혈류량 및 피부온도에 미치는 영향 (The Effects of Blood Circulation and Skin Temperature by Ultrasound)

  • 오민영;장철;김현정
    • The Journal of Korean Physical Therapy
    • /
    • 제16권4호
    • /
    • pp.179-201
    • /
    • 2004
  • The purpose of this study was to determine the effect of application methods in ultrasound on skin temperature and muscle blood flow. Thirty healthy volunteers without known vascular problems participated and randomly divided into three groups such as continuous wave group (CWG) which received a ultrasound treatment of continuous-wave, intermittent wave group (IWG) which received a ultrasound treatment of intermittent-wave at a dosage of $1.5\;W/cm^2$ for a duration of 5 minutes, and placebo group (PG) which received a ultrasound treatment of no-wave and no-dosage ultrasound to the anterior forearm. Blood flow and skin temperature was measured using MP 150 before and after ultrasound administration. The results were as follows : 1. Administration of ultrasound in all groups had increased effect on skeletal muscle blood flow immediately after treatment and for up to 10 minutes posttreatment. 2. CWG and IWG showed increased skin temperature immediately after a ultrasound administration and maintained to 10 minutes posttreatment. PG showed increased skin temperature immediately after a ultrasound administration but returned to initial state to 10 minutes posttreatment. 3. The great change on skeletal muscle blood flow among three groups showed in CWG ($6.27{\pm}1.72$) and then displayed in PG ($5.12{\pm}1.66$) and IWG ($4.61{\pm}2.19$) in order. 4. The vast change on skin temperature among three groups showed in CWG and then IWG and PG in order.

  • PDF

Clinical Relevance of Mobile Phone Interference with Electroretinography in Healthy Dogs: Experimental Study

  • Jung, Sunjun;Lee, Dongbin;Kim, Jury;Kim, Minsu;Heo, Suyoung;Kim, Namsoo
    • 한국임상수의학회지
    • /
    • 제37권3호
    • /
    • pp.130-134
    • /
    • 2020
  • This study aimed to confirm the effects that the mobile phone has on Electroretinogram (ERG). The ERG responses of three groups of healthy dogs, five in each group, were studied. ERG test was performed consecutively before and after the mobile phone was carried out. For group A, music was played with the sound on; for group B, music was played but the sound off; and for group C, the phone was set on the airplane mode. In the presence of a mobile phone, the amplitudes of a- and b-wave were increased in all groups. The a- and b-wave amplitudes at the flash intensity of 3,000 mcd·s/㎡ were significantly increased in all groups (p < 0.05). Based on the results, it is recommended to conduct ERG test in the absence of a mobile phone for the accurate evaluation of the retinal function.

20대 중국 여성들의 패션 라이프스타일에 따른 의복 구매행동과 한류 및 한국 패션에 대한 태도 (Clothing Purchasing Behavior and Attitude toward the Korean Wave and Korean Fashion according to the Fashion Lifestyle of Chinese Women in their 20s)

  • 박혜선;해비
    • 한국의류학회지
    • /
    • 제36권7호
    • /
    • pp.690-702
    • /
    • 2012
  • This study examined the fashion lifestyle of Chinese women in their 20s and analyzed the purchasing behavior of clothing and attitudes toward the Korean image, Korean Wave, Korean fashion, and preference for Korean fashion brands according to a fashion lifestyle. The major results were as follows: 1) Fashion lifestyle was comprised of factors for the pursuit of personality, pursuit of aesthetic, pursuit of brand, and pursuit of economy. The cluster analysis classified them into groups of: Economy/Personality Oriented, Aesthetic/Brand Oriented, and Fashion-Indifferent. 2) Information source and store patronage were different among the three consumer groups. 3) Attitude toward the Korean image, Korean Wave, Korean fashion, and preference for Korean fashion brands were different among the three consumer groups. These results can be used as the basic data or information for fashion companies that are developing marketing strategies for Chinese women in their 20s.

신경 손상 후 환측의 동작분석을 통한 충격파가 신경재생에 미치는 영향 (Impact of Shock Wave on Nerve Regeneration in Motion Analysis of Affected Side after Nerve Injury)

  • 이중호;최영덕;성연범
    • 예술인문사회 융합 멀티미디어 논문지
    • /
    • 제9권3호
    • /
    • pp.533-540
    • /
    • 2019
  • 본 연구는 체외 충격파 치료를 이용하여 신경 손상 흰쥐의 신경재생에 미치는 영향을 알아보았다. 본 연구에서는 체중이 230~280g고 생후 6주의 Sprague-Dawley계 수컷 흰쥐 30마리를 사용하였다. 무작위 추출방법을 이용하여 좌골신경 손상 후 체외 충격파 치료를 받는 실험군(n=15)과 좌골신경 손상 후 체외 충격파 치료를 받지 않는 대조군(n=15)으로 나누어 실험을 실시하였다. 본 연구에서 체외충격파 치료를 적용하기 위해서 체외 충격파 치료기(OPTIMUS, SALUS TALENT 3, Korea)를 이용하였으며 낮은 출력(low intensity)을 이용하여 오른쪽 후지의 좌골신경 압좌 부위에 적용하였다. 본 연구에서는 다트피쉬 소프트웨어를 이용하여 환측 후지의 입각기 시간과 보폭거리를 측정하였다. 환측 후지의 입각기 시간과 보폭거리의 그룹 간 변화량 비교에서 체외 충격파 치료를 적용한 실험군과 체외 충격파 치료를 적용하지 않은 대조군 사이에는 통계학적으로 유의한 차이가 있었다. 결론적으로 체외 충격파 치료는 신경재생에 긍정적인 영향을 미친다.

Half sine-wave pulsed electromagnetic fields 내에서 교정력에 의한 치아 이동에 대한 연구 (A STUDY ON THE ORTHODONTIC TOOTH MOVEMENT UNDER HALF SINE-WAVE PULSED ELECTROMAGNETIC FIELDS)

  • 김영준;유영규
    • 대한치과교정학회지
    • /
    • 제24권4호
    • /
    • pp.897-916
    • /
    • 1994
  • The biologic potential, which is different from the piezoelectric signals, relates tooth movement at least in part to changes in bone metaboliosm in bioelectric theory. The purpose of this experiment was to determine wheather the application of half sine-wave pulsed electromagnetic fields (HSPEMF) could increase both the rate and amount of orthodontic tooth movement. Forty-three male Hartley guinea pigs, weighting approximately 255g, were utilized in this study. The animals were 35 days old at the start of the study. Laterally directed orthodontic force was applied to the maxillary central incisors of 40 Hartley guinea pigs (20 experimental, 20 control). According to the amount of orthodontic force (6g, 12g), they were divided into two sub-groups (10 experimental I, 10 experimental II, 10 control I, 10 control II). During the experimental period, experimental animals were placed in plastic animal holders with their heads positioned in an area of uniform electromagnetic field. Control animals were placed in similar plastic holders that did not carry the electric apparatus. The results were as follows : 1. The application of a HSPEMF to the experimental groups significantly increase the final amount of orthodontic tooth movement observed over a 10-day experimental period. 2. The application of a HSPEMF to the experimental groups significantly increase the velocity of orthodontic tooth movement observed over a 10-day experimental period. 3. There was no significant difference in the final amount of orthodontic tooth movement at the fourth day to the eighth day, but there was significant difference in the final amount of orthodontic tooth movement at the nineth, tenth day during a 10-day experimental period. 4. After 10 days of HSPEMF exposure & orthodontic force, the experimental groups demonstrated more osteodasts in the pressure side than control groups.

  • PDF