• 제목/요약/키워드: wave block

Search Result 233, Processing Time 0.022 seconds

An Expremental Study on Connections Friction Test of Improvement for Coastal Environment Block (Coastal Environments 블록의 개발을 위한 연결부 마찰 실험)

  • Kim, Chun-Ho;Kim, Sang-Hoonq
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.49-52
    • /
    • 2008
  • The plain and simple shape water front structure were designed and installed for wave protection and wave resistance. But the installation of these plain and simple structure cause deficiency of environmental affinity. Also the resonance phenomena from the reflective wave and shipwave of the harbor incident wave caused high tide and wave, consequently maintaining the tranquility of inside harbor, give difficulty for mooring the ship and loading-unloading, increase the possibility of ship collision at the quray wall and landing place To solve these problems, we develop the environmentally friendly wave dissipation block. And installation efficiency, stability of the blocks through experiment of C.E Block Joint.

  • PDF

Investigation of Statbility of Truncated Tetrahedron Type Amore Block (깍은 사면체형 소파블록의 안정성 평가)

  • Cho, Hong-Dong;Bae, Woo-Seok;Kim, Myeong-Kyun;Lee, Ho-Jin
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.5
    • /
    • pp.43-47
    • /
    • 2009
  • Armor block is used to reduce wave energy. To do this, the stability of coastal structure is enhanced. It is very expensive to develop a new type armor block. So, the research of new type armor block is very short. We develope truncated tetrahedron type armor block(new type block) which have a hole in center part. In this study, the stability of new type armor block is investigated by hydraulic model test. In the result, the stability coefficient($K_D$) of new type armor block is 11.8. this value is more superior than value of tetrapod.

Static Performance Test for New Wave Dissipating Block Reinforced with FRP (FRP로 보강된 신형 소파블록의 정적 성능 실험)

  • Paik, In-Yeol;Oh, Young-Min
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.23 no.4
    • /
    • pp.285-291
    • /
    • 2011
  • In this study the mechanical performance of the new wave dissipating block is evaluated through experiment and numerical analysis. Also, by selecting adequate reinforcement, the improvement of the structural performance is examined. The reinforcement is designed by predicting the amount of tensile force and the location where the tensile stress develops in the new wave dissipating block through numerical analysis. The new wave dissipating block is reinforced with the ordinary steel bars and the fiber reinforced plastic(FRP) bars which have advantages in ocean environment in terms of corrosion and fatigue. The test result shows that the fracture resistance of the un-reinforced concrete block is 350 kN which is about 6.2 times that of the weight of the block. All the test blocks which are reinforced by either steel of FRP bars show strength capacity of over 900 kN which is the maximum load of the test equipment. Although the single reinforcement with larger-diameter bars has advantage in terms of construction convenience, it is recommended to use multiple number of smaller-diameter bars in order to reduce the crack width.

Eaperimental Study on the Control of Harbor Oscillation due to Water Wave (파랑에 의한 항내진동의 제어에 관한 실험적 연구)

  • Choi, han kuy;Lee, Seon Yong
    • Journal of Industrial Technology
    • /
    • v.14
    • /
    • pp.101-107
    • /
    • 1994
  • This study is to investigate harbor oscillation phenomenon according to combination of the wall structures by model experiment in a three dimensional wave basin. Six different types of wall combination were chosen through combination of erect wall, erect dissipation block, and sand beach, wave height at selected points in the harbor were measured by electronic wave gage. Test results show that the wall structure composed solely of erect walls showed generally highest harbor oscillation. Since natural beach shows lower reflection than erect dissipation block do, we thought it would be more efficient to use natural beach for improved harbor oscillation. The result showed, however, that the erect dissipation block are more efficient than natural beach to attain less harbor oscillation. The reason seens that the erect dissipation blocks have better capability to control breaking wave on the surface of the structure.

  • PDF

Hydraulic Model Experimental Study on the Rope Kink Phenomena and Mooring Block Behavior under Wave Conditions at a Seaweed Farm (연승 수하식 양식시설의 파랑 중 해조류 꼬임 현상 및 계류용 블록 이동에 관한 수리모형 실험적 연구)

  • Kim, Heon-Tae;Choi, Jin-Hyu;Yoon, Han-Sam
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.1
    • /
    • pp.11-17
    • /
    • 2014
  • In this study, a hydraulic model experiment under wave conditions was carried out to investigate the gap/distance between two near-unit farm lines that affects the rope kink and shape variation of a seaweed farm during mooring block movement. As a result, rope kink occurred during the low wave height condition as the gap/distance between the two near-unit farm lines decreased. The seaweed farm maintained a stable shape in the higher wave height conditions as the gap/distance between the two near-unit farm lines increased. This result indicates that rope kink is sensitively affected by the gap/distance between the two near-unit farm lines. A tendency to increase the critical wave height was observed when mooring block movement occurred, and as the mooring block weight and wave period increased. From the experimental results in which incident wave conditions and the mooring block weight changed, as the front side mooring block weight increased from 3.0 to 8.0 tons, the seaweed farm was stable, and rear side mooring block movement hardly occurred. The observed tension of the seaside mooring line was a maximum at about 3.0 ton/m.

The Impact of Armor Block Failure on Wave Pressure Acting on a Vertical Wall at the Front of a Caisson (피복 케이슨의 소파블록 이탈이 직립벽에 작용하는 파압에 미치는 영향)

  • Taegun Park;Yeon-Myeong Jung;Jeongheum Lee;Jaeheon Jeong;Dong-Soo Hur
    • Journal of Navigation and Port Research
    • /
    • v.48 no.4
    • /
    • pp.303-309
    • /
    • 2024
  • This study examines the effects of wave pressure on a vertical wall due to armor block failure at the front of a caisson, using a 2-D hydraulic model to simulate three types of armor block cross-sections. Additionally, the hydraulic characteristics of two cross-sections that replicated the armor blocks' failure, based on complete cross-sections, were compared. Moreover, quantitative analysis indicated that in the cross-section where the displacement of the armor block was recreated, wave run-up( ) increased by an average of 73%, the sum of dimensionless wave pressures increased by 28%, and converted wave force rose by 33%. These findings underscore the need for countermeasures in the event of armor block failure.

Hydrodynamic forces on blocks and vertical wall on a step bottom

  • Mondal, Ramnarayan;Alam, Md. Mahbub
    • Wind and Structures
    • /
    • v.30 no.5
    • /
    • pp.485-497
    • /
    • 2020
  • A study, using potential water wave theory, is conducted on the oblique water wave motion over two fixed submerged rectangular blocks (breakwaters) placed over a finite step bottom. We have considered infinite and semi-infinite fluid domains. In both domains, the Fourier expansion method is employed to obtain the velocity potentials explicitly in terms of the infinite Fourier series. The unknown coefficients appearing in the velocity potentials are determined by the eigenfunction expansion matching method at the interfaces. The derived velocity potentials are used to compute the hydrodynamic horizontal and vertical forces acting on the submerged blocks for different values of block thickness, gap spacing between the two blocks, and submergence depth of the upper block from the mean free surface. In addition, the wave load on the vertical wall is computed in the case of the semi-infinite fluid domain for different values of blocks width and the incident wave angle. It is observed that the amplitudes of hydrodynamic forces are negligible for larger values of the wavenumber. Furthermore, the upper block experiences a higher hydrodynamic force than the lower block, regardless of the gap spacing, submergence depth, and block thickness.

Reflection Characteristics of Eco Block on Seabed

  • Kim, Jeong-Seok;Lee, Joong-Woo;Kang, Seok-Jin;Lee, Yong-Hun
    • Journal of Navigation and Port Research
    • /
    • v.38 no.4
    • /
    • pp.421-427
    • /
    • 2014
  • In order to protect coastal facilities mainly from wave and current actions, the self-locking eco blocks constituting elements of protecting shore structures against scouring were designed. These blocks are adapted to the sloping bottom, coastal dunes, and submerged coastal pipelines, counteracting the destructive and erosive impulse action. A series of laboratory experiments has been conducted to investigate the reflection of water waves over and against a train of protruded or submerged shore structures and compare the reflecting capabilities of incident waves including wave forces. In this study the hydraulic model experiment was conducted to identify the performance of newly designed water affinity eco blocks to keep the coast slope and bottom mound from scouring by reduction of the wave reflection and to convince stability of the block placement. Revised design of each block element was also tested for field conditions. From the result of experiments, the field applicability of the developed blocks and placement was discussed afterward.

Comparative Analysis on Ground Impedance for a Carbon Block and a Copper Rod (탄소블록과 동봉의 접지임피던스 비교 분석)

  • Seo, Jae-Suk;Park, Hee-Chul;Kil, Gyung-Suk;Oh, Jae-Geun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.6
    • /
    • pp.472-477
    • /
    • 2013
  • This paper carried out the comparative analysis on ground impedance of a carbon block and a copper rod. Two types of grounding electrode were compared ; a carbon block (L : 1 m, ${\Phi}$ : 245 mm) buried at a depth of 0.8 m and a three-linked copper rod (L : 1 m, ${\Phi}$ : 10 mm) of equilateral triangles with 1 m spacing. Ground impedance depending on applied current source was evaluated by the application of a sine wave current with 60 Hz ~ 3.5 MHz, a fast-rise pulse with rising time of 200 ns, a standard lightning impulse of $8/20{\mu}s$ and a 600 Hz square wave. Ground impedance for both electrodes were almost the same value below 100 kHz, and increased rapidly afterwards. The maximum ground impedance appeared $400{\Omega}$ at around 1.5 MHz. Ground impedance of the carbon block was lower at the square wave and was higher at fast-rise pulse than that of the copper rod. Also, ground impedance as ages showed no difference for the last 8 months. From the results, it is likely that ground performance for both electrodes shows no difference against commercial frequency and lightning impulse current, while the copper rod shows better performance against a fast-rise pulse with rise-time of a few hundred ns.

Evaluation of Lateral Resistance for Tie-cell Wave-dissipating Block by Model Experiments (모형실험을 통한 타이셀소파블록 구조체의 수평저항력 평가)

  • Kim, Tae-Hyung;Kim, Jiseong;Choi, Ju-Sung;Kang, Gichun
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.12
    • /
    • pp.87-97
    • /
    • 2020
  • Recently, interest in Tie-cell wave-dissipating blocks that can compensate for the disadvantages of block-type breakwaters and provide economically effective design is increasing. Tie-cell wave-dissipating block has high activity resistance due to its structure in which each block is held together by a pile. In this study, through the laboratory model experiments, it was possible to confirm the increase in lateral resistance of the Tie-cell wave-dissipating blocks due to the penetration of the piles. The lateral resistance of the piles appeared almost constant regardless of the overburden load of the blocks. The lateral resistance shared by the piles changed depending on the increase or decrease in the lateral resistance of the friction between blocks. In the experiment in which two piles were penetrated, the overall lateral resistance was larger than the case a single pile was used, but the resistance behavior of the piles was different.