• Title/Summary/Keyword: waterproof method

Search Result 172, Processing Time 0.022 seconds

Development of Waterproofing Method to Improve the Leakage Resistance and Maintenance of Underground Structures (구조물 누수 저항 및 유지관리 향상을 위한 방수공법 개발)

  • Kim, Eun-seok;Park, Hyun-Jung;Lee, Dong-Oun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.50-51
    • /
    • 2020
  • Recently, various maintenance materials and construction methods have been developed to secure the sustainable performance of structures. However, waterproofing of underground structures where groundwater infiltration is present is very difficult. In particular, the location of underground structures such as subways is very deep, and it is difficult to apply waterproof materials and construction methods in the case of structures accompanied by vibration. Therefore, we intend to study materials and methods for waterproofing leakage resistance in special environments such as underground structures.

  • PDF

Bond Strength Measurement according to the Cement Liquid Waterproofing Method (시멘트 액체방수 시공방법에 따른 부착강도 특성)

  • Lee, Ji-Hwan;;Kim, Jin-Sik;Kim, Hye-Won;Cho, Seong-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.241-242
    • /
    • 2023
  • In this study, the bond strength characteristics of cement liquid waterproofing are confirmed. Investigation was made on the properties of adhesion strength due to cement liquid waterproof construction methods and changes in curing temperature. It is intended to reduce the possibility of tiles falling off by ensuring the adhesion strength of the cement liquid waterproofing.

  • PDF

An Experimental Study on the Cement-Polymer Coatings Waterproofing Method Composed with Waste Tire Chip and Waste Glass powder (폐타이어와 폐유리 미분말을 소재로 한 무기질 탄성도막 방수공법에 관한 실험적 연구)

  • 김영삼;양승도;이성일;김윤욱;오상근
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.11a
    • /
    • pp.17-22
    • /
    • 2002
  • This Waterproofing Material which mainly consisted of 2 components of waste tire chip powder and waste glass powder. This Study is abut development of waterproofing Material, There is not tried in domestic. The most Motive of this Study wishes to recycle resources and get the economic performance for waterproofing Material The result of this Study is as followings. (1) Dense waterproofing floor is formed between waste tire chip by Coupling Agent(the most effective method to encourage adhesive strength and raise cohesion of material by combination.) (2) Expected to bring effect to shorten construction period at spot application potentially space-time in moisture aspect. Also, shortening effect of construction period and spot work are considered to be gone efficiently selecting pre-mix construction method. (3) This development Waterproofing material has elasticity that nature side compatibility of cement ingredient and plastic Emulsion have when utilize and constructs waite resources (being waste tire chip and waste glass powdered).

  • PDF

A Study on the Repair Method and the Damage Status of Wooden Architectural Heritages - Focused on the wooden architectural heritages in Jecheon - (목조 건축문화재의 훼손현황과 보수방안 연구 - 제천시 목조 건축문화재를 중심으로 -)

  • Lee, Wan-Geon
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.3
    • /
    • pp.82-89
    • /
    • 2016
  • This study investigated the preservation status of wooden architectural heritages, designated as Chungcheongbuk-do designated heritage in Jecheon. The purpose of this paper is to find the damage cause and the preservation method of wooden architectural heritages. It was conducted using the research methods of the existing literature and field survey to compare a current status of wooden architectural heritages. The result are as followings. Firstly, it was found the problems of a break, a damage, etc. in the platform and the problems of a cracking, an exfoliation, a corrosion, a warp, etc. in the wall. And, it was found a cracking of the beam(梁) and a roof tile(瓦), a falling of Angto(仰土), a sagging roof, etc. in the roof. Secondly, the damage causes of wooden architectural heritages were mostly caused by the physical limitations of the materials. And, it was caused by a rainwater, a subsidence of ground settlement, a destruction of waterproof membrane, etc. Lastly, the repair methods are making a quicklime layer in the soil mound on a cracking and an exfoliation part, a resin treatment or strut operation on a corrosion part of column, etc.

Studies on the Control of AtoN Charge and Discharge Controller (항로표지 충·방전조절기의 제어에 관한 연구)

  • Ye, Seong-hyeon;Han, Soonhee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.654-657
    • /
    • 2014
  • In this paper, we proposed a short distance control method of AtoN charge and discharge regulator. The proposed control measures, was constructed by applying the communication standards NEMA018 of AtoN and control function analysis of the charge and discharge regulator that has been operating in the country. By using the control method is proposed, while maintaining the waterproof without product degradation, there is an advantage that can communicate control wired or wireless. Also, it is possible to ensure the accessibility of the charge and discharge regulator in operation, it is effective for maintenance. In this paper, installed the application to control the charge and discharge regulator to the smart-phone. by using a PC and Blue-tooth communication, to examine the effectiveness of the control information. Future, control method of power controller, can provide a national standard.

  • PDF

Analysis of North Korea's Residential Environment Satisfaction According to Construction Method (건축공법에 따른 북한의 주거환경 만족도 분석 연구)

  • Kim, Eun-Young;Baek, Cheong-Hoon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.222-223
    • /
    • 2020
  • Recently, as the era of economic cooperation on the Korean Peninsula approaches, the role of the building sector, such as humanitarian reorganization of North Korean housing, is increasing. The purpose of this study is to find out the current location of North Korean housing standards through the North Korean Housing Survey. For the survey, a survey was conducted through 79 North Korean defectors. The main construction methods of North Korean housing are reinforced concrete, steel framed, wooden framed, masonry, and reinforced concrete walled and prefabricated. The residential environment satisfaction items consist of durability, waterproof, heating, ventilation, heat insulation, air tightness, mining, soundproofing, disaster safety, fire safety, and crime prevention. The result is as follows. The housing construction method in North Korea, which lived at that time, consisted of 21 people (30.88%) of reinforced concrete frames, 18 people (26.47%) of wooden frames, 17 people (25%) of masonry walls, 5 people of prefabricated structures (7.35%), and reinforced concrete. Two people (2.94%) were walled. Among these, the wooden frame type had the lowest satisfaction level for each item, and the reinforced concrete had a high level of dissatisfaction in the items of heating, confidentiality, and disaster safety, and the other item had a high level of satisfaction. The masonry wall type has a relatively high satisfaction level in terms of insulation, confidentiality, mining, and disaster safety.

  • PDF

SPF Measurement and Cytotoxicity of Sunscreen Agents in Cosmetic (화장품에서 UV 차단제의 피부 자극성과 SPF 측정)

  • Kim, In-Young;Kang, Sam-Woo
    • Analytical Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.79-87
    • /
    • 1998
  • Consumers have recently preferred to purchase extensive UV intercepting products, which are waterproof and free from side effects on skin. During the testing of cytotoxicity (in-vitro) in neutral red (NR) method, cell survival ratio of UV-B interceptors decreased to just above 0.08 w/v%, and it was observed that the UV-A interceptors the ratio also decreased to just above 0.06 w/v%. In addition patch-tests of inorganic UV interceptors resulted in no skin irritation even below 10.0 and 11.25. In absorption curves, UV-B was most suitable for octyl methoxycinnamate (OMC) and UV-A for butyl methoxy dibenzoylmethane (BMDM). For this reason, $Nylonpoly^{TM}$ UVA/UVB the material of OMC and BMDM coated with Nylon & polyethylene, was used as the organic UV interceptor. Zinc oxide (ZnO) and titanium dioxide ($TiO_2$) was used as inorganic UV interceptors. The appropriate mixture ratio of ZnO and $TiO_2$ was 6 to 4:6% of ZnO, 4% of $TiO_2$ and 5% of $Nylonpoly^{TM}$ UVA/UVB were all combined and added to our sunscreen cream. The SPF value of in-vitro was 38.9. In practical application, each sun protection factor (SPF) duration of oil-in-water (O/W) emulsion and water-in-silicone (W/S) emulsion containing sunscreen cream of the same content showed that W/S type of sunscreen cream was 5 times as durable as the other. Therefore, this product is fit for use in swimming, climbing or skiing. This research is to minimize skin trouble caused by UV interceptors and to make one with proper softness, skin safety and UV intercepting efficiency.

  • PDF

Consumer Awareness Analysis of Residential Building Underground Structure Leakage Prevention Measurements (공동주택 지하공간 누수 예방 기술 정책 수립을 위한 소비자 인식 분석 연구)

  • Han, Yoon-Jung;Oh, Kyu-Hwan;Kim, Su-Ryon;Kim, Byoung-Il;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.379-387
    • /
    • 2016
  • In this study, a survey was conducted on the required measurement and waterproofing performance for residential building underground structure leakage prevention system. According to the results of the survey, it has been determined that leakage problem is considered to be quite severe, and many respondents have agreed. The legal guidelines and regulation systems do not reflect properly on the environmental requirements or conditions, resulting in continued leakage problem. In regards to this, a standardized waterproofing technique that can be used in underground areas of residential structures is required as an obligation and the development of high performance waterproofing method that allows for wet concrete surface adhesion and a guideline, design and maintenance method that allows the control of overall situational control of leakage is required.

A Study on Improvement of Modular Specifications - Focused on technical specifying method in waterproof and mechanical works - (모듈러 공사시방서 개선방안에 관한 연구 - 방수 및 기계설비공사의 기술방안 개선을 중심으로 -)

  • Yoon, Jongsik;Shin, Dongwoo;Cha, Heesung;Kim, Kyungrai
    • Korean Journal of Construction Engineering and Management
    • /
    • v.18 no.3
    • /
    • pp.33-41
    • /
    • 2017
  • A modular specification is a contract document that specifies the requirements of production, transformation and installation in a modular construction. A problem of the currently used specification is that it does not guarantee the level of performance required by the modular construction and fails to accommodate unique characteristics of each construction because it widely uses the standard specification as it is. This study proposes a specification that reflects the unique feature of modular construction in order to improve the quality of modular construction. Research focuses on the leakage in waterproof and mechanical equipment because it is the area with the highest rate of defects. This study suggests ways to improve the modular specification as follows: 1)Descriptive specifying (following MasterFormat) 2)Propose leakage verification method and test clause 3) Reflect characteristic of modular construction. Proposed modifications to modular specification are reviewed by experts for validation and their opinion verifies suggested improvements as a way to secure the quality of modular construction and to promise characteristics of the modular specification. This improvement will be used for reference when writing construction project specification, which can be an important contract document, so that it could lower occurrence rate of the modular defects.

A Study on the Waterproofing Performance of Waterproofing Methods for PHC-W Earth Retaining Wall Based on Pressure Chamber Test (PHC-W 흙막이 공법의 차수방안에 관한 차수성능확인을 위한 모형 압력 수조 실험 연구)

  • Choi, Yongkyu;Johannes, Jeanette Odelia;Yun, Daehee;Kim, Chae min;Jeon, Byeong Han
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.12
    • /
    • pp.115-125
    • /
    • 2017
  • PHC-W earth retaining wall could be constructed continuously. Various retaining wall methods such as C.I.P. etc. method require separate waterproof method. However, the PHC-W retaining wall method prevents leakage of groundwater by inserting a waterproofing material at connection part between 2 PHC piles. In this study, the experimental study on 3 waterproofing method for PHC-W retaining wall was conducted at the model pressure chamber. In the method using textile with 1-liquid type and 2-liquid type urethane, rapid leak occurred at the pressure of 120 kPa and 140 kPa or more. In the method of textile with grouting, rapid leak occurred at the pressure of 120 kPa or more, however, in this method, the rapid leakage happened at the top part and the bottom part reinforced with urethane.