• Title/Summary/Keyword: waterproof design

Search Result 88, Processing Time 0.024 seconds

Development of a Bath Assistive System with Water Temperature Monitoring to Prevent Heart Attack (수온 모니터링 기능을 탑재한 심장마비 방지용 목욕 보조 시스템)

  • Kang, So Myoung;Wei, Qun
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.2
    • /
    • pp.242-249
    • /
    • 2019
  • Old people and patients with cardiovascular disease could die of a heart attack in the bath with heated water for a long time. Various researches have been studied to prevent these accidents from happening such as measuring the ECG signal when taking bath. However, these devices are hard to use and the higher price is not easily accepted by the public. In this paper, a low-cost and use-friendly, real time high precision water temperature monitoring device to prevent heart attack in the bath was developed. The device with waterproof design that lets the device can float on the surface of the water, and an accurate way to make water temperature measurement method was proposed by this paper that is immerging the sensor into water with 4cm depth to measure the temperature of underwater. The manufactured device was conducted to two experiments; one was to verify the basic functions of the device, and another one was for compare the proposed device with commercial products for monitoring the water temperature in the bathtub. As the experimental results shown, the proposed device has stable performance for the water temperature measurement and communicating with laptop in wireless.

Effect of Silane Coupling Treatment on the Joining and Sealing Performance between Polymer and Anodized Aluminum Alloy

  • Lee, Sung-Hyung;Yashiro, Hitoshi;Kure-Chu, Song-Zhu
    • Korean Journal of Materials Research
    • /
    • v.31 no.3
    • /
    • pp.122-131
    • /
    • 2021
  • In the fabrication of joined materials between anodized aluminum alloy and polymer, the performance of the metal-polymer joining is greatly influenced by the chemical properties of the oxide film. In a previous study, the dependence of physical joining strength on the thickness, structure, pore formation, and surface roughness of films formed on aluminum alloys is investigated. In this study, we investigated the effect of silane coupling treatment on the joining strength and sealing performance between aluminum alloy and polymer. After a two-step anodization process with additional treatment by silane, the oxide film with chemically modified nanostructure is strongly bonded to the polymer through physical and chemical reactions. More specifically, after the two-step anodization with silane treatment, the oxide film has a three-dimensional (3D) nanostructure and the silane components are present in combination with hydroxyl groups up to a depth of 150 nm. Accordingly, the joining strength between the polymer and aluminum alloy increases from 29 to 35 MPa, and the helium leak performance increases from 10-2-10-4 to 10-8-10-9 Pa ㎥ s-1.

A modified shell-joint model for segmental tunnel dislocations under differential settlement

  • Jianguo Liu;Xiaohui Zhang;Yuyin Jin;Wenyuan Wang
    • Geomechanics and Engineering
    • /
    • v.35 no.4
    • /
    • pp.411-424
    • /
    • 2023
  • Reasonable estimates of tunnel lining dislocations in the operation stage, especially under longitudinal differential settlement, are important for the design of waterproof gaskets. In this paper, a modified shell-joint model is proposed to calculate shield tunnel dislocations under longitudinal differential settlement, with the ability to consider the nonlinear shear stiffness of the joint. In the case of shell elements in the model, an elastoplastic damage constitutive model was adopted to describe the nonlinear stress-strain relationship of concrete. After verifying its applicability and correctness against a full-scale tunnel test and a joint shear test, the proposed model was used to analyze the dislocation behaviors of a shield tunnel in Shanghai Metro Line 2 under longitudinal differential settlement. Based on the results, when the tunnel structure is solely subjected to water-earth load, circumferential and longitudinal joint dislocations are all less than 0.1 mm. When the tunnel suffers longitudinal differential settlement and the curvature radius of the differential settlement is less than 300 m, although maximum longitudinal joint dislocation is still less than 0.1 mm, the maximum circumferential joint dislocation is approximately 10.3 mm, which leads to leakage and damage of the tunnel structure. However, with concavo-convex tenons applied to circumferential joints, the maximum dislocation value reduces to 4.5 mm.

Consumer Awareness Analysis of Residential Building Underground Structure Leakage Prevention Measurements (공동주택 지하공간 누수 예방 기술 정책 수립을 위한 소비자 인식 분석 연구)

  • Han, Yoon-Jung;Oh, Kyu-Hwan;Kim, Su-Ryon;Kim, Byoung-Il;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.379-387
    • /
    • 2016
  • In this study, a survey was conducted on the required measurement and waterproofing performance for residential building underground structure leakage prevention system. According to the results of the survey, it has been determined that leakage problem is considered to be quite severe, and many respondents have agreed. The legal guidelines and regulation systems do not reflect properly on the environmental requirements or conditions, resulting in continued leakage problem. In regards to this, a standardized waterproofing technique that can be used in underground areas of residential structures is required as an obligation and the development of high performance waterproofing method that allows for wet concrete surface adhesion and a guideline, design and maintenance method that allows the control of overall situational control of leakage is required.

Development of Embedded Board for Integrated Radiation Exposure Protection Fireman's Life-saving Alarm (일체형 방사선 피폭 방호 소방관 인명구조 경보기의 임베디드 보드 개발)

  • Lee, Young-Ji;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1461-1464
    • /
    • 2019
  • In this paper, we propose the development of embedded board for integrated radiation exposure protection fireman's life-saving alarm capable of location tracking and radiation measurement. The proposed techniques consist of signal processing unit, communication unit, power unit, main control unit. Signal processing units apply shielding design, noise reduction technology and electromagnetic wave subtraction technology. The communication unit is designed to communicate using the wifi method. In the main control unit, power consumption is reduced to a minimum, and a high performance system is formed through small, high density and low heat generation. The proposed techniques are equipment operated by exposure to poor conditions, such as disaster and fire sites, so they are designed and manufactured for external appearance considering waterproof and thermal endurance. The proposed techniques were tested by an authorized testing agency to determine the effectiveness of embedded board. The waterproof grade has achieved the IP67 rating, which can maintain stable performance even when flooded with water at the disaster site due to the nature of the fireman's equipment. The operating temperature was measured in the range of -10℃ to 50℃ to cope with a wide range of environmental changes at the disaster site. The battery life was measured to be available 144 hours after a single charge to cope with emergency disasters such as a collapse accident. The maximum communication distance, including the PCB, was measured to operate at 54.2 meters, a range wider than the existing 50 meters, at a straight line with the command-and-control vehicle in the event of a disaster. Therefore, the effectiveness of embedded board for embedded board for integrated radiation exposure protection fireman's life-saving alarm has been demonstrated.

The Compressive Strength and Durability Properties of Polypropylene Fiber Reinforced EVA Concrete (폴리프로필렌 섬유 보강 EVA 콘크리트의 압축강도 및 내구성)

  • Nam, Ki Sung;Sung, Chan Yong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.4
    • /
    • pp.11-19
    • /
    • 2015
  • The important properties of EVA (ethylene vinyl acetate) redispersible polymer was waterproof, densification of internal pore space of concrete and ball bearing and micro filler. Also, the significant role of polypropylene(PP) fiber was crack control and blockade of movement for deterioration factors. The most studies for EVA were limited in the field of mortar and PP fiber reinforced concrete had been studied in the state of being restricted unit water content, rich mix and mixing much of the fiber without considering construction site. Therefore, the control mix design were applied in ready mixed concrete using 10 % fly ash of total cement weight used in batch plant. On the basis of control mix design, EVA contents ranging from 0 % to 10 % of total cement weight and PP fiber contents ranging from 0 % to 0.5 % of EVA concrete volume were used in the mix designs. The results showed the maximum compressive strength value was measured at EVA 5.0 % and PP fiber 0.1 %, the minimum water absorption ratio was at EVA 10 % and PP fiber 0 %, the durability factor for freezing and thawing resistance was at EVA 5.0 % and PP fiber 0.3 % and the minimum weight reduction ratio of resistance to sulfuric acid attack was at EVA 10 % and PP fiber 0.5 % after curing age 42days. Meanwhile, From these results, PP fiber reinforced EVA concrete would be very benefit, if each optimal mix types were used in hydraulic structures, underground utilities and agricultural structures.

Characteristics of Housing Condition for Physically Challenged Persons in Rural Area from the Viewpoint of Planning Customized Housing for the Disabled (장애인 맞춤형 주택 계획 관점에서 본 농촌지역 지체장애인 주거특성 연구)

  • Lee, Yeun-Sook;Park, Ji-Young;Lee, Dong-Joo
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.6
    • /
    • pp.154-162
    • /
    • 2015
  • As there is no case study with current status, measurements or description on the state of actual site of rural area only, the delivery of actual conditions about such an area is significantly limited. The purpose of this study is to pinpoint issues with housing conditions of low-income family with disabled members in the rural area. For such a purpose, 25 households of disabled people have been visited for interview, on-site research and survey, of which results are summed up in this paper as following: First, average monthly income of such family turned out to be KRW 480,000, most of which is from the government subsidy. High ratio of such families has resided in a house with average size of approximately 56m2 for about 24 years. Secondly the most needed maintenance work with top priority was for the toilet, and many of the interviewees expressed their discomfort about small size of their bathrooms and inconvenient facilities therein. Thirdly, most of such houses had too high thresholds that posed danger and inconvenience. Such thresholds had average height of 13cm, which can be considered as completely inconsiderate of disabled users. Fourth issue was that these people needed safety handle that will enable them to stand up or to be in the standing posture in the living room and bedroom where they spend most of their time. Fifthly, they wanted finishing materials with waterproof functionality as well as replacement of finishing materials and wallpaper which were too old and caused hygiene issues. As these issues represent, current housing for disabled people in the rural area turned out to be poor and risky space rather than the place where difficulty of individual situation can be resolved or their disability can be complemented. Thus it can be determined that now is the time to arrange the solutions for such housing difficulties and to establish customized housing plan to ensure safety and convenience.

A Study on the Seismic Performance Design of Waterproofing Materials Applied Single-side Walls on Underground Structures (지하 구조물 외벽에 적용되는 방수재료의 구조체 거동 및 진동 대응 성능 설계 제안 연구)

  • Kim, Soo-Yeon;Kim, Meong-Ji;Oh, Sang-Keun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.1
    • /
    • pp.43-50
    • /
    • 2020
  • In this study, the possibility of seismic performance design was proposed and the quality verification test method was reviewed as part of the design of waterproof performance in underground walls under accelerated environment conditions for waterproofing materials, which are barrier and finishing material that can prevent ingress or overflowing water from inside and outside of a building by attaching all of the construction materials used in construction structures. Considering the current state of earthquake-resistant design of construction materials in Korea and abroad, seismic product groups are rare and mostly dependent on construction methods because there are no regulations on materials, although there are still regulations on earthquake-resistant design in the building process under the current law. Overseas, it was possible to confirm that various building materials that gave seismic performance to non-structural materials, such as Japan, Canada, and Germany, are being developed. If it is possible to have a complementary response to earthquakes in the advanced external waterproofing materials, it can be expected to be applicable as leak prevention and prevention technology along with the seismic designed structure.

Study on Design Method of Tunnel-type Ammunition Storage Chamber (터널형 탄약고의 격실 설계 방법에 대한 연구)

  • Park, Sangwoo;Baek, Jangwoon;Park, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.3
    • /
    • pp.279-287
    • /
    • 2020
  • Recently, the demand for underground-type ammunition storage facilities has increased. Comparing with a ground-type ammunition storage facility, the underground-type ammunition storage facility can decrease the standard of safety distance because fragment and blast wave can be locked in the rock formation. However, the absence of a design method on the underground-type ammunition storage chamber became a major setback for the construction promotion. In this study, the process for designing an overall configuration of the underground-type ammunition storage facility was provided. First, the determination method for configuration and number of the chamber was developed by performing the ammunition storage simulation. Then, a tunnel (i.e., transfer channel for vehicles) and designed chambers can be arranged on the basis of safety distance standard. The safety distance standard also should be considered for determining the location and the size of entrances because of the blast wave and fragment effect at the entrances when an explosion is generated inside a chamber. In addition, considerations on the design for the waterproof and the drainage of subsurface water were analyzed through construction cases. Finally, an example of designing underground-type ammunition storage chambers was provided in order to verify the developed design process.

An Empirical Study on the Standard Re-establishment of Water Discharge Performance for the Fire Engine Pump (소방차 펌프의 방수성능 기준 재정립을 위한 실증적 연구)

  • Min, Se-Hong;Kwon, Yong-Joon
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.85-91
    • /
    • 2012
  • This paper analyzed firefighting officers' use situations such as the use time, maximum working pressure, hose diameter, etc. of fire pumps at fire sites and carried out various performance tests by pressures, hose diameters and quantities of fire pumps based on its results because the waterproof performance criterion for a fire pump installed in a fire engine is different from the operation situations at the site and is not clearly prescribed. As a result of site survey, the site uses a higher pressure than the standard water discharge pressure (0.85 MPa) or the high-pressure water discharge pressure (1.4 MPa) prescribed by the approval Standard of the fire pump performance on fire truck. In addition, as a result of pump performance test, the discharged water flow rate, water discharge pressure, etc. was measured to be very different from the currently prescribed the approval standard depending on the hose diameter and firefighting nozzle, so the result of this study proposes a new standard.