• Title/Summary/Keyword: water-treatment sludge

Search Result 635, Processing Time 0.032 seconds

A Feasibility Study for Renewable Energy from Sewage Sludge Biogas (하수슬러지 Biogas의 신재생에너지화 타당성 연구)

  • Kang, Ho;Lee, Hye Mi;Cho, Sang Sun;Park, Sun Uk;Jeong, Ji Hyun
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.754-760
    • /
    • 2010
  • This study was carried out not only to evaluate optimal operating condition to increase biogas production, but also to estimate feasibility of renewable energy from anaerobic digester of sewage sludge. Semi- continuous Fed and Mixed Reactors (SCFMRs) were operated in various condition to quantify the reactor variables. The result of SCFMR operation showed that the biogas productivity and total volatile solids (TVS) removal of total solids (TS) 4% reactor at hydraulic retention time (HRT) 20 days with Organic Loading Rate (OLR) of $1.45kg/m^3-d$ were $0.39m^3/m^3-d$ and 26.7%, respectively which was two times higher than that of TS 2.5% reactor. Consequently the daily biogas production of $20,000m^3$ would be possible from the total volume of $52,000m^3$ of anaerobic digesters of the municipal wastewater treatment plant in D city. In feasibility study for the Biogas utilization, combined heat and power system (CHP) and CNG gasification were examined. In case of CHP, the withdrawal period of capital cost for gas-engine (GE) and micro gas-turbine (MGT) were 7.7 years and 9.1 years respectively. biogas utilization as Clean Natural Gas (CNG) shows lower capital cost and higher profit than that of CHP system. CNG gasificaion after biogas purification is likely the best alternative for Biogas utilization which have more economic potential than CHP system. The withdrawal period of capital cost appeared to be 2.3 years.

The Effect of Unleached Agents on the Stabilization/Solidification of Hazardous Sludge Containing Heavy Metals (有害슬러지 固形化에 따른 重金屬 溶出防止剖의 影饗)

  • 이성호
    • Journal of Environmental Health Sciences
    • /
    • v.19 no.2
    • /
    • pp.46-54
    • /
    • 1993
  • This study was carried out on the stabilized/solidified treatment for the reducing leachability of hazardous heavy metals copper, lead, chromium and cadmium in the hazardous sludge which treated to be unleached heavy metals by sodium diethyl dithiocarbamate. Cement matrix was analyzed for the leachability of 24 hrs and dynamic leaching test, structure and the optimum condition for the stabilization and solidification of the hazardous sludge. In 28 days of curing time the unconfined compressive strength was 21.5 kg/cm$^2$ at the ratio of portland cement (0.5)+fly ash (0.25) and 23.5 kg/cmz at the ratio of portland cement (0.5)+fly ash (0.25) + cake (0.25). High concentration of Pb, Cr and Cd in the sea water and Cu in the distilled water were leached at the dynamic leaching test. The concentration of leaching heavy metals for specimens which were tested 24 hrs were found low leachability with decreasing pH of leachant. According to dynamic leaching test, the low level of copper, lead, cadmium and chromium were leached in the cement matrix with sodium diethyl dithiocarbamate. But the effective diffusion coefficient of unleached cement matrix which was treated sodium diethyl dithiocarbamate was decreased above 2 times than that of cement matrix. The relation of leachant renewal period (Y) and cumulative fraction ion leached (X) was the following regression equations. Solidification with unleached agent. Y$_{Cu}$ = 1413752X + 247, Y$_{Pb}$ = 223501IX + 214, Y$_{Cr}$ = 8310601X - 472, Y$_{Cd}$ = 168787X + 1061 The structure of' solidified matrix with X-ray diffraction analysis was composed more Ca(OH)$_2$, Si, Mg(OH)$_2$ and Al in the unleached cement matrix than those in cement matrix.

  • PDF

A Study on the Treatment of Swine Wastewater by Using Intermittently Aerated Activated Sludge Process (간헐폭기법에 의한 돈사 폐수 처리에 관한 연구)

  • Yang, Tae-Du;Lee, Mi-Kyung;Chung, Yoon-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.4
    • /
    • pp.86-96
    • /
    • 1998
  • In this study, an intermittently aerated activated sludge process, modified process from conventional activated sludge process, was developed to treat high strength swine wastewater, which has been blamed as major pollutant for stream pollution. Therefore, the optimum cycle for oxic and anoxic period, SRT, and OLR were studied as design parameters. The effects of different time interval for oxic and anoxic period on nitrification and denitrification were examined by operating two reactors with 60/60min and 60/90min as oxic/anoxic period. Although the reactor with 60/60min showed complete denitrification of $NO_x-N$ generated during oxic period, the reactor with 60/90min showed incomplete nitrification due to the inactivity of nitrifier by accumulated $NH_3-N$ toxicity during anoxic period. Therefore, it is recommended to operate same interval for oxic and anoxic period. In order to determine the optimum cycle for oxic/anoxic period, four different reactors with 30/30, 60/60, 90/90 and 120/120min were examined. The reactor operation with 90/90min was optimum to get the most stable results in this study. However, the optimum cycle for oxic and anoxic period should be changed with characteristics of influent wastewater and operating conditions. According to lie operation results of three reactors with SRT of 15, 20 and 30days. The reactor with 2Odays SRT showed best removal efficiency of T-N. The optimum OLR would be $2.5Kg\;COD/m^3/day$ which showed the most stable nitrification and denitrification. Since characteristics of influent wastewater in the real system has a severe fluctuation, so it is very difficult to determine each interval for oxic and anoxic period. Therefore, ORP curves, describing the change of oxidation/reduction potential in reactor, can be used as a control parameter for automatic control of oxic and anoxic period. In other words, bending point (Nitrate Knee) of ORP curve during anoxic period could be used as a starting point of oxic period.

  • PDF

The Condition of Optimum Coagulation for Recycling Water from CMP Slurry

  • Seongho Hong;Oh, Suck-Hwan
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.415-420
    • /
    • 2001
  • Water usage in the semiconductor industries is dramatically increased by not only using bigger wafer from 8 inches to 12 inches but also by adapting new process such as Chemical Mechanical Planarization (CMP) process invented by IBM in late '80. However, The document published by International Semiconductor Association suggests the decreasing ultra pure water (UPW) use from 22 gallon/in$^2$in 1997 to 5 gallon/in$^2$ in 2012. The criteria will possibly used as exporting obstacle in the future. Generally, Solid content of CMP slurry is about 15wt%. The slurry is diluted with UPW before fed to a CMP process. When the slurry is discharged from the process as waste, it contains 0.1~0.6wt% of solid content and 9~10 at pH. The CMP waste slurry is discharged to stream with minimum treatment. In this study, to find optimum condition of coagulation for water recovery from the waste CMP slurry various condition of coagulation were examined. After coagulation far 0.1 wt% solid content of waste CMP slurry, the sludge volume was 10~15% after 30 min of sedimentation time. For the 0.5 wt%, sludge volume was 50~55% after one hour of sedimentation time. For more than 80% of water recycling, the solid content should be in the range of 0.1 to 0.2wr%. Based on the result of the turbidity removal, the Zeta Potential and the analysis of heavy metals, the optimum condition for 0.1 wr% of waste CMP slurry was with 20 mg/L of PACI at 4 to 5 of pH. The result showed that the optimum conditions fer the 0.1 wt% waste CMP slurry were 100mg/L of Alum at 4~5 of pH, 100 mg/L of MgCI$_2$at pH 10 to 11 and 100 mg/L of Ca(OH)$_2$at pH 9 to 11, respectively.

  • PDF

Relationship between Energy Consumption and Operational Variables at Wastewater Treatment Plant (상관분석 및 의사결정나무분석을 통한 하수처리시설의 에너지 소비량과 운영인자의 관계 분석)

  • Jung, Yong-Jun;Kim, Ye-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.3
    • /
    • pp.253-260
    • /
    • 2016
  • To reduce energy consumption in wastewater treatment plants (WWTPs), renewable energy applications such as small hydropower, solar energy, and wind energy are popular. However, it should be noticed that energy originated from operation of wastewater treatment process can be reduced through optimized operation based on analysis of factors affecting energy. In this research, the relationship to the various operational variables and influent factors was explored using correlation analysis and decision tree algorithm. Due to the non-linear characteristics of the process, it was difficult to find clear linear patterns through correlation analysis. However, decision tree algorithm showed its usefulness in uncovering hidden patterns that consume energy. As operational factors, influent flowrate, the amount of aeration, nitrate recycling pumping rate, and sludge wasting pumping rate were selected as important factors. For environmental factors associated with influent compositions and removal rate, BOD and T-N removal rate were selected as significant factors.

A Study on Current Energy Consumption and Recycling at Public Wastewater Treatment Plants in Korea (국내 공공하수도 시설의 에너지 사용 및 자원화실태 조사연구)

  • Park, Seungho;Kim, Byongjoo;Bae, Jae-Ho;Lee, Cheol Mo;Kim, Eung-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.539-549
    • /
    • 2007
  • To establish effective and prompt measures for energy conservation in public wastewater treatment plants in Korea, energy consumption rates in 233 utilities in 9 provinces and 7 metropolitan cities are investigated and compared to the rest of the world. Mean load factor for wastewater treatment utilities is 74.9% and those for influent pumps and aeration blowers are 56.2% and 61.0%, respectively. Mean electrical energy usages as the key performance indicators are $0.243kWh/m^3$ for overall sewage treatments and 2.07 kWh per unit kg BOD removal. Digester gas as one of major byproducts in the process amounts to $382,000m^3/day$ nationwide. While major part of the digester gas is used for sludge heating, only 7.3% of the gas is utilized for electricity generation. Both efficiencies for BOD removal and digestion gas generation are considerably lower than those in USA and EU utilities due to low concentration of organic material in influent wastewater. Such low energy regeneration, in turn, results in significantly higher energy consumption in Korean plants, compared to that in USA and EU ones.

Eveluation of Comparable Removal Efficiency of Organics and Color for the Dyeing Wastewater by Fenton Oxidation and Ozonation (펜톤산화와 오존산화 조합에 따른 염색폐수의 유기물질 및 색도 처리효율 비교 평가에 관한 연구)

  • Kim, Sun Hee;Lee, Sang Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.6
    • /
    • pp.778-784
    • /
    • 2004
  • Dyeing wastewater contains recalcitrant organics which can not be easily treated by conventional biological treatment. Therefore it has to be treated by other advanced oxidation process in order to remove COD and Color more efficiently. Fenton oxidation process is one of the most commonly applied processes in removal of COD and color for the dyeing wastewater. However it increase the treatment cost and the production of sludge by the use of the excessive chemical reagent. Ozonation is not suitable in Single treatment process because it is not effective in organics removal compared with Color removal. The purpose of this research in order to evaluate the comparable removal efficiency of COD and color by the combination of advanced oxidation processes for the dyeing wastewater. The sequential treatment processes of Fenton process and ozonation was more effective to remove organics and color than ozonation and Fenton process. The result of Fenton process for the pretreatment presented as the 81% removal of organics whereas ozonation process for the pretreatent presented as the 22.1% removal of organics. The removal of colour was higher as 81.3% for the ozonation as the pretreatment than 77.7% for the Fenton process as the pretreatment.

A Study on Energy Usage Monitoring and Saving Method in the Sewage Treatment Plant (공공하수처리시설에서 에너지 사용현황 및 절감방안 연구)

  • Kim, Jongrack;Rhee, Gahee;You, Kwangtae;Kim, Dongyoun;Lee, Hosik
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.6
    • /
    • pp.535-545
    • /
    • 2020
  • This study aims to conserve and monitor energy use in public sewage treatment plants by utilizing data from the SCADA system and by controlling the aeration rate required for maintaining effluent water quality. Power consumption in the sewage treatment process was predicted using the equipment's uptime, efficiency, and inherent power consumption. The predicted energy consumption was calibrated by measured data. Additionally, energy efficiency indicators were proposed based on statistical data for energy use, capacity, and effluent quality. In one case study, a sewage treatment plant operated via the SBR process used ~30% of energy consumed in maintaining the bioreactors and treated water tanks (included decanting pump and cleaning systems). Energy consumption analysis with the K-ECO Tool-kit was conducted for unit processing. The results showed that about 58.7% of total energy consumed was used in the preliminary and biological treatment rotating equipment such as the blower and pump. In addition, the energy consumption rate was higher to the order of 19.2% in the phosphorus removal process, 16.0% during sludge treatment, and 6.1% during disinfection and discharge. In terms of equipment energy usage, feeding and decanting pumps accounted for 40% of total energy consumed following 27% for blowers. By controlling the aeration rate based on the proposed feedback control system, the DO concentration was reduced by 56% compared pre-controls and the aeration amount decreased by 28%. The overall power consumption of the plant was reduced by 6% via aeration control.

Development and Field Application of the Advanced Wastewater Treatment process (KSMBR) by Hollow Fiber Submerged Membrane (침지식 중공사막을 결합한 Dynamic state 하수고도처리공정(KSMBR process)의 개발 및 현장적용평가)

  • Kim, Ji-yeon;Seo, In-seok;Kim, Hong-suck;Kim, Youn-kwon;Kim, Byung-goon;Choi, Chang-gyu;Ahn, Hyo-won;Seo, Wan-seok;Jang, Moon-seog
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.358-363
    • /
    • 2006
  • KSMBR process is dynamic state advanced wastewater treatment applied with Trisectional Aeration (TSA) mode combined with membrane. TSA was remodeled conventional intermittent aeration which was operated nonaeration-aeration. TSA operates nonaeration ($N_1$) - aeration (A) - nonaeration ($N_2$) in Trisectional Aeration Reactor (TAR). Organics of influent could be nearly consumed to denitrification without influence by remained DO in TAR and it could be operated about sludge return ratio of 1Q (influent base). The purpose of this study was to apply KSMBR to the full-scale plant and to evaluate efficiency of nitrogen and phosphorus removal and TSA operation. The result of this study, average CODcr/T-N and CODcr/T-P ratio were 7.8 and 59.6, respectively. BOD, TCODcr, SS, T-N, T-P, E-coli removal efficiency were 98.4, 95.2, 73.0, 69.6, 99.95 %, respectively. KSMBR obtained high removal efficiencies of C, N and P when it applied full-scale plant.

Recycling of Wastepaper(XV) -Contamination of Process Water by System Closure- (고지재생연구(제15보) -제지 공정수 폐쇄화에 따른 오염 및 변화에 관한 연구-)

  • 조미선;윤혜정;류정용;신종호;송봉근
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.33 no.2
    • /
    • pp.32-40
    • /
    • 2001
  • It is desirable to reduce the amounts of fresh water and reuse the recycled water in papermaking process. In an attempt to improve the efficiency of recycling water refining treatment and to enhance the productivity of OCC recycling mill, up flow anaerobic sludge blanket(UASB) reactor was developed and introduced to Korea recently. In order to maximize the operating efficiency and minimize the adverse side effects it is imperative to estimate and evaluate the total effects of new system, UASB on the whole OCC recycling process. This study was carried out with a view to investigate the effects of the high temperature and alkalinity of process water on the quality ad productivity of testliner of OCC recycling mill which is equipped with UASB reactor and almost closed. Another object of this study was searching for the best available use of UASB treated process water. The results were as follows; Reuse of UASB treated water characterized with high temp and alkalinity was useful to improve the strength and drainage properties of recycled OCC owing to its good points of promoting OCC disintegration and reducing the calcium hardness of process water. However, it might not be avoidable to induce the increase of dissolved solids in process water in accordance with direct introducing of UASB treated water into the former stage of OCC stock preparation. So it would be advisable to adopt the UASB treated water in the stage of clean, screened OCC stock.

  • PDF