• 제목/요약/키워드: water-treatment

검색결과 12,111건 처리시간 0.04초

Profiling Total Viable Bacteria in a Hemodialysis Water Treatment System

  • Chen, Lihua;Zhu, Xuan;Zhang, Menglu;Wang, Yuxin;Lv, Tianyu;Zhang, Shenghua;Yu, Xin
    • Journal of Microbiology and Biotechnology
    • /
    • 제27권5호
    • /
    • pp.995-1004
    • /
    • 2017
  • Culture-dependent methods, such as heterotrophic plate counting (HPC), are usually applied to evaluate the bacteriological quality of hemodialysis water. However, these methods cannot detect the uncultured or viable but non-culturable (VBNC) bacteria, both of which may be quantitatively predominant throughout the hemodialysis water treatment system. Therefore, propidium monoazide (PMA)-qPCR associated with HPC was used together to profile the distribution of the total viable bacteria in such a system. Moreover, high-throughput sequencing of 16S rRNA gene amplicons was utilized to analyze the microbial community structure and diversity. The HPC results indicated that the total bacterial counts conformed to the standards, yet the bacteria amounts were abruptly enhanced after carbon filter treatment. Nevertheless, the bacterial counts detected by PMA-qPCR, with the highest levels of $2.14{\times}10^7copies/100ml$ in softener water, were much higher than the corresponding HPC results, which demonstrated the occurrence of numerous uncultured or VBNC bacteria among the entire system before reverse osmosis (RO). In addition, the microbial community structure was very different and the diversity was enhanced after the carbon filter. Although the diversity was minimized after RO treatment, pathogens such as Escherichia could still be detected in the RO effluent. In general, both the amounts of bacteria and the complexity of microbial community in the hemodialysis water treatment system revealed by molecular approaches were much higher than by traditional method. These results suggested the higher health risk potential for hemodialysis patients from the up-to-standard water. The treatment process could also be optimized, based on the results of this study.

Emergy를 이용한 오염물질 저감시설의 환경 비용/편익 분석 (Environmental Cost and Benefit Analysis Pollutant Reduction Facilities of the using the Emergy)

  • 김진이;황하선;김상수;이재관
    • 한국물환경학회지
    • /
    • 제29권5호
    • /
    • pp.591-597
    • /
    • 2013
  • The input emergy of an advanced treatment plant for reducing the 1 kg of TN and TP was estimated 4.14E+14 sej/kg, 5.02E+15 sej/kg, respectively. In addition, the input emergy of constructed wetland for reduction of the 1 kg of TN and TP reduction was estimated to be 2.48E+14 sej/kg, 3.38E+15 sej/kg, respectively. The cost reducing 1 kg of TN and TP for an advanced treatment plant was estimated 197,466 won and 2,388,739 won respectively and constructed wetland was estimated 117,976 won and 1,609,213 won respectively. As a result, All of the emergy source of constructed wetland for reducing non-point source is renewable resource. If we use the constructed wetland, it results in enhancing economic value by reducing of non-point pollution, controlling a flood and providing the habitat of animals or plants. Improving water quality program in the Nakdong River Basin should be changed into an ecological treatment facilities from expansion of the sewage treatment facilities and advanced treatment plant using high cost and non-renewable energies.

4불화탄소 플라즈마처리에 의한 폴리에스테르 직물의 발수가공 (Water Repellent Finish of Polyester Fabric Using Carbontetrafluoride Plasma Treatment)

  • 모상영;이용운;김태년;천태일
    • 한국염색가공학회지
    • /
    • 제6권3호
    • /
    • pp.27-36
    • /
    • 1994
  • In order to produce a water repellent surface on polyester fabric, samples were treated in the atmosphere of $CF_4$ glow discharge plasma. The samples used in the study were ployester fabric and poyester film. The purpose of film treatment is for the comparison of hydrophobicity with fabric sample at same treatment condition. Radio frequency(13.56MHz) generator was used as electric source and its in put power is 100 Watt. Water repellency was evaluated by contact angle measurement. Result obtained are as follows. 1) Fiber interstice of original fabric was ana lysed as 0.43$\mu$m, and this value was sufficiently ideal for making water repellent fabric. 2) The most favorable setting position of substrate was the center area between two electrodes. 3) Fabric contact angle was higher than film contact angle at same treatment condition, and its difference was more than 50${\circ}$. And it was incapalbe of fabric contact angle measurement when the film contact angle was less than 90${\circ}$. because the fabric is susceptible to absorption of water by the capillary effect. 4) Fabric contact angle can not revealed the precise defferences of surface hydrophobicity, however, the film contact angle showed the real hydrophobic nature. 5) It was not sufficient method to evaluate the hydrophobicity of fabric surface by merely measure of the water contact angle. 6) It showed high water repellent nature at 0.06 torr of $CF_4$ plasma gas pressure and duration of 45 seconds treatment, and it can not be anticipated more improved nature if the pressure and duration of treatment time were increased.

  • PDF

Evaluating Commercial Spray Applications of Lactic Acid, Hot Water, and Acidified Sodium Chlorite for the Reduction of Escherichia coli on Beef Carcasses

  • Kang, Dong-Hyun;Lee, Sun-Young
    • Food Quality and Culture
    • /
    • 제2권1호
    • /
    • pp.55-60
    • /
    • 2008
  • This study examined the effects of lactic acid spray, hot water spray, or their combined treatment, as well as the effects of acidified sodium chlorite (ASC), for the decontamination of Escherichia coli on beef carcass surfaces using a commercial intervention system. With this system, the effects of 2 or 4% lactic acid (v/v), hot water ($89{\pm}1^{\circ}C$), or their combined treatment, were examined in terms of reducing inoculated E. coli. ASC (266 ppm), which was adjusted to pH 2.5 using acetic acid or citric acid, was applied using a hand-held spray system. When the beef carcasses were treated with 2 or 4% lactic acid for 10.4 s, less than 1 log reductions of inoculated E. coli were observed. A hot water spray treatment for 9.8 s resulted in a 2.1 log reduction of inoculated E. coli. However, when the hot water was followed with either 2 or 4% lactic acid, no difference in E. coli reduction was found between the hot water alone or the combined treatment with lactic acid. When ASC was adjusted to pH 2.5 with acetic acid and citric acid, 3.8 and 4.1 log reductions of E. coli were observed, respectively. Overall, the lactic acid spray treatment was least effective, and the ASC treatment was most effective, for the E. coli decontamination of beef carcasses. Therefore, these data suggest that ASC would be a more effective intervention against E. coli than most of the methods currently being used. However, more research is required to evaluate the effects of ASC on other organisms, as well as to identify application methods that will not affect meat quality.

  • PDF

Pre-Sowing Seed Treatment: Effect of Deep Sea Water Priming on Germination of Wild Vegetables; Gondalbi (Cirsium setidens), Jandae (Adenophora triphylla var. Joponica Hara) and Deoduck (Codonopsis lanceolata Trautv.)

  • Yoon Byeong-Sung;Shrestha Surendra Lal;Kang Won-Hee
    • 한국자원식물학회지
    • /
    • 제19권6호
    • /
    • pp.680-686
    • /
    • 2006
  • This experiment was conducted on wild vegetables; Gondalbi (Cirsium setidens), Deoduck (Codonopsis lanceolata Trautv.), and Jandae (Adenophora triphylla var. Joponica Hara) seed to study whether priming with deep sea water results in enhancement of seed germination and identify the optimum concentration of the priming solution, and duration of priming. Seeds were primed with 5 various concentrations (5%, 10%, 15%, 20% and 30%) of deep sea water (DSW) in 12 hours, 24 hours, and 48 hours at $24^{\circ}C$. Since Jandae had seed dormancy, it was kept for four weeks in refrigerator at $2^{\circ}C$ after priming treatment. In Deoduck, 5 percentage DSW priming significantly improved the early germination percentage, radicle length, and plumule emergence percentage. Among the priming period of treatments, 24 hours priming showed better performance in this treatment whereas, in Jandae, 12 hours priming with 10 percentages DSW significantly improved the germination percentage and germination rate. This treatment had increased the final germination percentage by 54%, 15% and 40% compared with control, plain water and $KNO_3$ priming respectively. But in Gondalbi, priming did not improve the germination of seed. However, among the priming treatments, 12 hours priming with 3% $KNO_3$ and 20% DSW gave better performance. In both the wild vegetables; Deoduck and Jandae, priming in deep sea water had improved the germination percentage and germination rate as compare to plain water, $KNO_3$, and without priming treatment. Hence the best seed priming treatment on Deoduck and Jandae are 24 hours with 5% DSW and 12 hours with 10% DSW respectively.

물안전계획(Water Safety Plan)의 국내 도입방안 (Introduction of Water Safety Plan in Korea)

  • 김진근
    • 상하수도학회지
    • /
    • 제26권4호
    • /
    • pp.535-545
    • /
    • 2012
  • Recently, drinking water quality has significantly improved with the progress of water treatment technologies, however, customer's trust on tap water is still relatively low. Low trust on water quality is mainly due to vague anxiety. Therefore, to improve customer's trust on drinking water quality new strategy such as water safety plan(WSP) which recommended by WHO and IWA should be introduced. WSP can be defined as an approach which uses comprehensive risk assessment and risk management approach that encompasses all steps in water supply from catchment to consumer to ensure the safety of a drinking water supply. In this study, cases on WSP introduction in other countries as well as strategy for the introduction of WSP in Korea were investigated. In addition, recommendations on the improvement of the current water contamination response manual was suggested based on the analysis of the existing manual at a full scale water treatment plant.

상수도 배관망에서의 수질변화에 관한 연구 (수질악화의 영향인자 분석과 잔류염소 모델링) (A study on Water Quality Changes in Distribution System (Factor analysis of deterioration of water quality & Modelling of free chlorine))

  • 이현동;정원식;문숙미
    • 상하수도학회지
    • /
    • 제11권3호
    • /
    • pp.59-66
    • /
    • 1997
  • Although it produces well-treated water in water treatment plant, water quality at the tap can be changed depending on the state of pipes. It is because water quality deteriorates as plant water passes through pipeline networks. Therefore, the improvement of not only water treatment technology but also O & M of water pipelines is required to supply good water to consumers. The purpose of the study was to obtain the basic data of control technology for water quality in pipes through investigating water quality in distribution system. We selected 11 sampling sites and investigated water quality from plant to endpoint of distribution system. we also simulated decreasing tendency of free chlorine through pipeline network. As the result of water quality test, all parameters were below allowable levels, but some parameters had the possibility of being over levels. So there must be more work to set up proper countermeasure for violable parameters.

  • PDF

탈수(脫水) 및 건조기법(乾燥技法)을 이용한 정수장(淨水場) 슬러지 감량화(減量化) (Sludge Minimization by Using Dewater and Thermal Treatment in the Water Treatment Plant)

  • 전항배;김영한;김량
    • 유기물자원화
    • /
    • 제2권1호
    • /
    • pp.87-98
    • /
    • 1994
  • 슬러지 발생량은 정수처리공정에서 부터 슬러지 농축 및 탈수에 이르는 과정을 최적화하므로써 감량화할 수 있다. 본 논문에서는 탈수 및 건조기법에 의하여 정수처리공정에서 발생하는 슬러지의 함수율을 낮추어 슬러지 발생량을 줄이는 방법에 대하여 연구하였다. 탈수효율향상을 위한 polymer 투입량 및 교반조건등을 최적화하고, 온도에 따른 슬러지의 중량변화에 대하여 관찰하였다. 탈수효율은 polymer의 종류보다 교반강도에 의한 영향이 크고, pH의 영향도 큰 것으로 나타났다. 최적 polymer 주입농도는 1.5mg-polymer/g-TSS이었고, pH가 약산성이나 약알카리성 조건에서 탈수효율이 양호한 것으로 나타났다. 교반강도는 낮을수록(10,000ses-1이하) 효율이 향상되었고, 속도구배(G)보다 GT값이 중요한 영향인자인 것으로 나타났다. 자유수의 건조는 $100^{\circ}C$ 전후, 화학적 결함수는 $300^{\circ}C$ 근방에서 증발하며, 유기물질은 약 $300-600^{\circ}C$ 구간에서 산화되어 증발하는 것으로 나타났다. 취수원 수질에 따라 강열감량은 약 15-40%로 나타났으며, 화학적 결합수에 의한 감량이 약 10-20%, 유기물질에 의한 감량이 약 4-20%인 것으로 나타났다.

  • PDF

미생물에 의한 발효처리 (Wastewater Treatment by Microorganism)

  • 신석봉
    • 한국미생물·생명공학회지
    • /
    • 제8권2호
    • /
    • pp.135-142
    • /
    • 1980
  • The process of biological treatment of organic wastewater is principally associated with those of self-purification in the natural water environment. The treatment system has e intensive function of stabilizing wastewater more effectively than in natural water, which is like natural water concentrated in a small space. Biological treatment of wastewater involves activated sludge and various modified process, trickling filter, rotating disk, oxidation ditch, etc. for aerobic decomposition and anaerobic processes such as anaerobic decomposition and methane fermentation. The basic characteristic of these processes is the use of mixed culture for the conversion of pollutants. This review forcuses on the various kinds of microorganisms related to each treatment processes. Kinetic analysis of the activated sludge process is discussed in order to understand the basis of control and maintenance of the biological treatment process.

  • PDF

홍미삼과 홍삼정박의 건열처리가 Fusarium owsporum의 균사 생장과 승홍에 대한 내성에 미치는 영향 (Effect of Dry Heat Treatment of Red Ginseng and Red Ginseng Residue on Mycelial Growth and on Induced Tolerance of Fusarium oxysporum to Mercury Chloride)

  • 김영호;박명한;이종원
    • Journal of Ginseng Research
    • /
    • 제16권2호
    • /
    • pp.99-104
    • /
    • 1992
  • Korean red ginseng and water extract residue of red ginseng roots were treated with dry heat and incorporated in PDA medium to examine the effect of the materials on induced tolerance against mercury chloride and mycelial growth of Fusarium oxysporum. Ginseng residue was not effective in the inducement of tolerance to mercury chloride regardless of dry heat treatment. However, the heat treatment of ginseng and ginseng residues stimulated the mycelial growth of the fungus. The materials responsible for the detoxification appeared to be water-soluble. The stimulation of the fungal mycelial growth on the media by the heat treatment was highest in the water extract of ginseng. Due to the heat treatment, the mycelial growth was also slightly increased in n-hexane and methanol extracts of ginseng, compared with the ginseng fractions without dry heat treatment.

  • PDF