• Title/Summary/Keyword: water-treatment

Search Result 12,111, Processing Time 0.04 seconds

Effect of Sub- and Super-critical Water Treatment on Physicochemical Properties of Porcine Skin

  • Jo, Yeon-Ji;Kim, Jae-Hyeong;Jung, Kyung-Hun;Min, Sang-Gi;Chun, Ji-Yeon
    • Food Science of Animal Resources
    • /
    • v.35 no.1
    • /
    • pp.35-40
    • /
    • 2015
  • Super- and sub-critical water treatments have been of interest as novel methods for protein hydrolysis. In the present study, we studied the effect of sub-critical water (Sub-$H_2O$, $300^{\circ}C$, 80 bar) treatment as well as super-critical water (Super-$H_2O$, $400^{\circ}C$, 280 bar) treatment on the physicochemical properties of porcine skin (PS), which has abundant collagen. Porcine skin was subjected to pre-thermal treatment by immersion in water at $70^{\circ}C$, and then treated with sub- or super-critical water. Physicochemical properties of the hydrolysates, such as molecular weight distribution, free amino acid content, amino acid profile, pH, color, and water content were determined. For the molecular weight distribution analysis, 1 kDa hydrolyzed porcine skin (H-PS) was produced by Super-$H_2O$ or Sub-$H_2O$ treatment. The free amino acid content was 57.18 mM and 30.13 mM after Sub-$H_2O$ and Super-$H_2O$ treatment, respectively. Determination of amino acid profile revealed that the content of Glu (22.5%) and Pro (30%) was higher after Super-$H_2O$ treatment than after Sub-$H_2O$ treatment, whereas the content of Gly (28%) and Ala (13.1%) was higher after Sub-$H_2O$ treatment. Super-$H_2O$ or Sub-$H_2O$ treatment affected the pH of PS, which changed from 7.29 (Raw) to 9.22 (after Sub-$H_2O$ treatment) and 9.49 (after Super-$H_2O$ treatment). Taken together, these results showed that Sub-$H_2O$ treatment was slightly more effective for hydrolysis than Super-$H_2O$ was. However, both Sub-$H_2O$ and Super-$H_2O$ treatments were effective processing methods for hydrolysis of PS collagen in a short time and can be regarded as a green chemistry technology.

Behavior of perfluorinated compounds in advanced water treatment plant (고도 정수처리장에서의 과불화합물 거동)

  • Lim, Chaeseung;Kim, Hyungjoon;Han, Gaehee;Kim, Ho;Hwang, Yunbin;Kim, Keugtae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.5
    • /
    • pp.323-334
    • /
    • 2020
  • Adsorption by granule activated carbon(GAC) is recognized as an efficient method for the removal of perfluorinated compounds(PFCs) in water, while the poor regeneration and exchange cycles of granule active carbon make it difficult to sustain adsorption capacity for PFCs. In this study, the behavior of PFCs in the effluent of wastewater treatment plant (S), the raw water and the effluents of drinking water treatment plants (M1 and M2) located in Nakdong river waegwan watershed was monitored. Optimal regeneration and exchange cycles was also investigated in drinking water treatment plants and lab-scale adsorption tower for stable PFCs removal. The mean effluent concentration of PFCs was 0.044 0.04 PFHxS g/L, 0.000 0.00 PFOS g/L, 0.037 0.011 PFOA g/L, for S wastewater treatment plant, 0.023 0.073 PFHxS g/L, 0.000 0.00 PFOS g/L, 0.013 0.008 PFOA g/L for M1 drinking water treatment plant and 0.023 0.073 PFHxS g/L, 0.000 0.01 PFOS g/L, 0.011 0.009 PFOA g/L for M2 drinking water treatment plant. The adsorption breakthrough behaviors of PFCs in GAC of drinking water treatment plant and lab-scale adsorption tower indicated that reactivating carbon 3 times per year suggested to achieve and maintain good removal of PFASs. Considering the results of mass balance, the adsorption amount of PFCs was improved by using GAC with high-specific surface area (2,500㎡/g), so that the regeneration cycle might be increased from 4 months to 10 months even if powdered activated carbon(PAC) could be alternatives. This study provides useful insights into the removal of PFCs in drinking water treatment plant.

A Survey of THMs Formation in J Water Purification Plant and Its Reduction by PAC Treatment during Summer (J 정수장의 하절기 THMs 생성현황과 분말활성탄 처리에 의한 저감효과)

  • Hwang, Gap-Soo;Lee, Jang-Hoon
    • Journal of Environmental Health Sciences
    • /
    • v.25 no.3
    • /
    • pp.1-6
    • /
    • 1999
  • This study was conducted to survey trihalomethane(THMs) levels in finished water of J water treatment plant and examine its reduction by powder activated carbon(PAC) treatment. Samples were collected weekly based and head-space technique was employed to determine THMs levels by G.C-ECD. THMs levels in finished waters were highest in August and showed close relationship with water temperature. All the samples satisfied the drinking water limit(100 ${\mu}$g/l) for THMs. The individual formation rates of THMs were 64.8% for CHCl$_3$, 28.4% for CHCl$_2$BR, 6.5% for CHClBr$_2$ and 0.3% for CHBr$_3$, respectively and showed little monthly difference. The reduction efficiency of THMs formation by PAC treatment was 67% during July and August. Bromine substituents were more efficiently reduced than CHCl$_3$ by PAC.

  • PDF

Degradation of THM precursor using $TiO_2$ photocatalytic oxidation in the water treatment processes (정수처리공정에서 $TiO_2$광촉매를 이용한 THM전구물질 제거에 관한 연구)

  • Cho Deok-Hee;Seo Su-Man
    • Journal of environmental and Sanitary engineering
    • /
    • v.19 no.2
    • /
    • pp.1-6
    • /
    • 2004
  • In Bok-Jeong water treatment plant, chlorination is the only technique used for disinfection of drinking water. This disinfecting treatment leads to the formation of trihalomethanes (THMs). This study was carried out to investigate the possibility of improving removal efficiency of THM precursor in the conventional water treatment processes by $TiO_2$ photocatalytic oxidation. Removal efficiencies of DOC, $UV_{254}$, THMFP were low in the conventional water treatment processes. With application of $TiO_2$ photocatalyst, DOC, $UV_{254}$, THMFP were reduced more effectively. As the $TiO_2$ photocatalytic reaction time increased, the removal efficiencies of DOC, $UV_{254}$, THMFP were increased. The $TiO_2$ photocatalytic removal efficiencies of DOC, $UV_{254}$, THMFP were increased with increasing $TiO_2$ dosage. However, over 0.6g/l of $TiO_2$ dosage, the efficiency reached a plateau.

Water Quality Improvement Evaluation of Community Sewerage by using Advanced Sewage Treatment (고도하수처리공법을 적용한 마을 하수도의 수질개선 평가)

  • Choi, Han-Kuy;Ko, Jeong-Sup;Park, Soo-Jin
    • Journal of Industrial Technology
    • /
    • v.32 no.A
    • /
    • pp.57-64
    • /
    • 2012
  • In order to examine the tailorability of advanced sewage treatment of a separated sewer pipe, we observed the quality of leaked water in a reactor. A2C affiliation and MBR affiliation decreased by over 78% in cases of BOD, COD, and SS. SBR affiliation decreased by 79.1% in a case of T-N. Overall, the efficiency of T-N on the above affiliations was low. SS had the high efficiency in MBR affiliation. In the end, examination of water quality improvement showed that the quality was improved from 20% to 90%; hence, it is expected that this treatment can protect the water resources of the Hongcheon River and makes it easier to use the water of the river.

  • PDF

Development of Benchmark Index of LoS for Asset Management of Water Treatment Facilities (정수시설 자산관리 LoS분석 벤치마크지수 개발)

  • Nam, Youngwook;Hyun, Inhwan;Lee, Chulsung;Chun, Mingyu;Kim, Mincheol;Kim, Dooil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.6
    • /
    • pp.667-683
    • /
    • 2015
  • Since aged water treatment facilities could threaten the sustainable water supply, asset management system has been adopted for their systematic management. Level of Service(LoS) is one of critical components of asset management and could be quantified through benchmark index(BMI). Water supplier could estimate consumer's satisfaction and their performance through BMI to improve the LoS. We developed BMI for water treatment facilities from customer's satisfaction survey. BMI, represented with the Total Service Score(TSS), was assessed with water quality, water pressure, taste and odor, water rate, and service quality with weighing factors. BMI could, further, be used to assist the analysis of the life cycle cost to increase the unit of LoS.

VOCs Removal in Drinking Water Treatment Process by Ozonation (오존산화에 의한 수처리공정에서 VOCs의 제거 특성)

  • Han, Myung-Ho;Choi, Joon-Ho;Lim, Hak-Sang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.2
    • /
    • pp.65-75
    • /
    • 1997
  • Removal characteristics of volatile organic carbons(VOCs) by ozone oxidation and other processes in the raw water of the 1st Nakdong water treatment plant were investigated. Dichrolomethane, toluene and other 7 compounds were detected in the raw water. With regard to detected 4 compounds in finally treated water, it was found that VOCs could not be removed effectively by traditional water treatment process. Benzene, 1,2-dichlorobenzne were not detected in the raw water but they were detected in the process of treatment. The compound of highest detection frequency was dichloromethane. When the raw water was controlled at pH 7, temperature $20^{\circ}C$, 5 minutes as contact time, 10 minutes as reaction time, the removal rate of THMFP, $KMnO_4$ demand, TOC, $UV_{254nm}$ and $NH_3-N$ were 46.4%, 22%, 19.6%, 31% and 8%, respectively. From estimating the finally treated water qualities in 7 kinds of treatment processes, P-6 process(raw water-chlorination-coagulation-ozonation) was most effective for organics removal and THMs control. Removal efficiencies for $KMnO_4$ demand and TOC by the process which combined preozonation with coagulation was twice better than only preozonation. $NH_3-N$ removal rate was shown as 10% by P-3 process(raw water-coagulation-ozonation), but 83% of $NH_3-N$ was removed by P-4 process(raw water-coagulation-chlorination). It was found that the chlorination is more effective than the ozonation for the NH3-N removal as commonly known.

  • PDF

Development of the Sludge Treatment System in Water Bath of Painting Booth (도장부스 수조 내 슬러지 처리 시스템의 개발)

  • Lee, Chan;Cha, Sang-Won;Yoo, Young-Don
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.1 s.28
    • /
    • pp.30-36
    • /
    • 2005
  • A sludge treatment system for introducing the waste water mixture with paint sludge from the water bath of paint booth and for recycling cleaned water to paint booth after sludge separation is developed. Floated sludge is introduced from the water surface in the bath by using floating-skimmer, and is conveyed by pump to the centrifugal separator where sludge and cleaned water are separated. From the operation results of the present sludge treatment systems applied in actual paint booths, paint sludge can be separated automatically and effectively from water bath with its water content of $60-70\%$, and sludge-free clean water is returned to paint booth.

Development of the Sludge Treatment System in Water Bath of Painting Booth (도장부스 수조 내 슬러지 처리 시스템의 개발)

  • Lee, Chan;Cha, Sang Won;Yoo, Young Don
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.259-266
    • /
    • 2004
  • Developed is a sludge treatment system for introducing the waste water mixture with paint sludge from the water bath of paint booth and for recycling cleaned water to paint booth after sludge separation. Floated sludge is introduced from the water surface in the bath by using floating skimmer, and is conveyed by pump to the centrifugal separator where sludge and cleaned water are separated. From the operation results of the present sludge treatment systems applied in actual paint booths, paint sludge can be separated automatically and effectively from water bath with its water content of $60-70\%$, and sludge-free clean water is returned to paint booth.

  • PDF

A Treatment Efficiency of Wastewater by using Sym-Bio Process and Dissolved Ozone flotation Process for Water Reuse (하수처리수 재이용을 위하여 Sym-bio공정과 용존 오존 부상공정을 이용한 하수처리의 효율 분석)

  • Park, Changyu;Park, Jaehan;Lee, Kyunghee;Ahn, Yoonhee;Ko, Kwangbaik;Jung, Hyuncheol
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.1
    • /
    • pp.86-90
    • /
    • 2008
  • Water reuse of effluent is limited, due to bacteria and chromaticity or turbidity which may result in low perception of water quality. Consequently, this study showed a method in the reuse of treated wastewater by a diversified treatment method, with separation of centralized reformation of aeration tank into pre-treatment with minimum installation of facilities, and post-treatment, applying advanced oxidation treatment. A pilot plant experiment was performed using Sym-Bio process adopting an NADH Sensor without modification of the exiting aeration tank. The Dissolved Ozone Flotation process, which is an advanced oxidation process, to treat the remaining organics, nutrients, chromaticity, turbidity and bacteria. As a result in the Sym-Bio process, the biological treatment, even on the condition of single stage reaction tank, the treatment efficiencies of BOD, $COD_{Mn}$, $COD_{Cr}$, SS and T-N were 96.6%, 84.6%, 88.25%, 95.1% and 71.0%, respectively, while that for T-P was 25.0%, which required further treatment. In the Dissolved Ozone Flotation process, the advanced oxidation treatment, the treatment efficiencies of BOD, $COD_{Mn}$, $COD_{Cr}$, SS, T-N, T-P, chromaticity, turbidity, bacteria, coliforms were 78.9%, 34.6%, 28.7%, 48.0%, 70.4%, 82.4%, 84.0%, 74.5%, 99.8% and 99.4%, respectively.