• Title/Summary/Keyword: water-purifying

Search Result 84, Processing Time 0.019 seconds

소규모 고도 수처리 기술 -가정용 정수시스템 중심으로-

  • Sung, Kyung-Hak;Cho, Bong-Yeon;Park, Ho-Wan
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.06a
    • /
    • pp.207-231
    • /
    • 1997
  • The use household water purifier is continuously increasing due to the distrust of the piped, rap water, which may be caused by the deterioration of water quality and water supply facilities in Korea. The water purifier distributing in the domestic market is the membrane type that composes of membrane as a basic filter, sediment filter as a prefilter and activated carbon filter instead of one purifying water system. The membrane type using as a water cleaning system is mainly the method of micro filtration(NIF) as well as ultra filtration(UF) and reverse osmosis(RO). The types of MF and UF are using to remove suspended solids and virus, and RO is using to remove ionic compound in chemical organic compounds. At the beginning the household water purifier was imported as end-product or assembled by only importing module from small businesses in Korea. Therefore, people was hard to confide in the product quality because the sales policy and management of water purifier by small business were not effectively organized. However, the defects of water purifier having up to now ate improving by the efforts of special branches of water purifier and large enterprises, and new great products are developing and producing. To develop the best quality product of water purifier in Korea, it should be considered seasonal water characteristrics rather than any other condition. For example, the water purifier can be affected by the water temperature change, increase of suspended solids in the rainy season and inflow of raw water having concentration in a dry season. The subject we have to investigate in the future is to develop the water purifying system adaptable in Korea which can treat the water quality using close analyses of local and seasonal water characteristics.

  • PDF

A Study on Operating Method to Save Energy from the Adsorption Dryer in the Process of Purifying Compressed Air (고순도 압축공기 제조시스템의 흡착식 Dryer에서 에너지절감을 위한 운전방법에 관한 연구)

  • Kang, Seok-Wan;Chang, Sung-Ho;Kim, Hyeon-Joon;Kim, Sung-Soo;Lee, Yeong-Wook
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.3
    • /
    • pp.180-191
    • /
    • 2016
  • Optimizing energy usage for maximum efficiency is an essential goal for manufacturing plants in every industrial manufacturing sector. The generation and distribution of purifying compressed air is a large expense incurred in practically all manufacturing processes. Not only is the generation and treatment expensive equipment of compressed air, but frequent maintenance and effective operation is also required. As a plant's compressed air system is often an integral part of the production process, it needs to be reliable, efficient, and easy to be maintain. In this paper, we study to find operating method to save energy from the adsorption dryer in the process of purifying compressed air, which is required for a clean room production site in "A" company. The compressed air passes through a pressure vessel with two "towers" filled with a material such as activated alumina, silica gel, molecular sieve or other desiccant material. This desiccant material attracts the water from the compressed air via adsorption. As the water clings to the desiccant, the desiccant particle becomes saturated. Therefore, Adsorption dryer is an extremely significant facility which removes the moisture in the air $70^{\circ}C$ below the dew point temperature while using a lot of energy. Also, the energy consumption of the adsorption dryer can be varied by various operating conditions (time, pressure, temperature, etc). Therefore, based on existing operating experiments, we have searched operating condition to maximize energy saving by changing operating conditions of the facility. However, due to a short experiment period (from September to October), further research will be focused on considering seasonality.

Optimization of coagulant dosing process in water purification system using neural network (신경회로망을 이용한 상수처리시스템의 응집제 주입공정 최적화)

  • Nam, Ui-Seok;Park, Jong-Jin;Jang, Seok-Ho;Cha, Sang-Yeop;U, Gwang-Bang;Lee, Bong-Guk;Han, Tae-Hwan;Go, Taek-Beom
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.6
    • /
    • pp.644-651
    • /
    • 1997
  • In the water purification plant, chemicals are injected for quick purification of raw water. It is clear that the amount of chemicals intrinsically depends on water quality such as turbidity, temperature, pH and alkalinity. However, the process of chemical reaction to improve water quality (e.g., turbidity) by chemicals is not yet fully clarified nor quantified. The feedback signal in the process of coagulant dosage, which should be measured (through the sensor of the plant) to compute the appropriate amount of chemicals, is also not available. Most traditional methods focus on judging the conditions of purifying reaction and determine the amounts of chemicals through manual operation of field experts using Jar-test data. In this paper, a systematic control strategy is proposed to derive the optimum dosage of coagulant, PAC(Polymerized Aluminium Chloride), using Jar-test results. A neural network model is developed for coagulant dosing and purifying process by means of six input variables (turbidity, temperature, pH, alkalinity of raw water, PAC feed rate, turbidity in flocculation) and one output variable, while considering the relationships to the reaction of coagulation and flocculation. The model is utilized to derive the optimum coagulant dosage (in the sense of minimizing turbidity of water in flocculator). The ability of the proposed control scheme validated through the field test has proved to be of considerable practical value.

  • PDF

Studies of Purifying Waste Cotton for Esterification & Molecular Weight Distribution Curve of Cellulose Acetate (落綿의 精製 및 이를 原料로 하는 醋酸纖維素의 分子量 分配曲線에 關한 硏究)

  • Kim, Dong-Il;Noh, Ick-Sam
    • Journal of the Korean Chemical Society
    • /
    • v.4 no.1
    • /
    • pp.38-43
    • /
    • 1957
  • Purified cellulosic materials suitable for the production of cellulose esters can be prepared from waste cotton (carding waste from textile mill). The most desirable conditions in purifying waste cotton were obtained. Waxy materials were removed by boiling in 2-3% soda ash solution for more than 30 minutes in open vessel at atmospheric pressure. As for bleaching, it is desirable to use the bleaching powder solution containing 1%, available chlorine for 60 minutes at 35 deg. C. Purified cellulosic material was acetylated to fibrous cellulose triacetate, which was fractionated in the solution of 70% monochloroacetic acid using water as a precipitant, and the degree of polymerizaion and molecular weight of each fraction were measured viscometrically, thereon, molecular weight distribution curve was drawn. Analyzing the shape of this curve, most of the polymers were concentrated on the part of higher degree of polymerization. Purified waste cotton was also analysed, the result was that this cellulosic material can be used as a raw material for cellulose esters and ethers.

  • PDF

Adsorption Characteristics of Granular Activated Carbon Filter Used for Drinking Water Purifier (정수기용 입상활성탄소 필터의 흡착특성에 관한 고찰)

  • Baek, Young-Man;Park, Je-Chul;Kim, Hyung-Jin
    • Journal of Environmental Science International
    • /
    • v.17 no.8
    • /
    • pp.899-905
    • /
    • 2008
  • Quality test for activated carbon(AC) filter used for drinking water purifier is now an obligatory test and the standard material for valid purifying amount in water purifier performance test has been changed from residual chlorine to chloroform according to the notice of Ministry of Environment in 2006. Therefore, this study aimed to compare the ingredients of AC filters by confirming chloroform removal rate of AC filter and conducting 4 adsorption tests (Iodine, methylene blue decolorization, phenol value, ADS value) for AC filters provided by manufacturers. With water pressure of $1kgf/cm^2$, 1,500 liters of prepared inflow went through to check chloroform removal rate. As a result, product with removal rate of below 60% from all products. On the other hand, 4 adsorption tests were conducted for filters in the market and filters from manufacturers. None of the products satisfied all 4 tests. In particular, they showed great shortage to the standard in phenol value and ADS value test. However, manufacturers' filter showed much better performance than filters in the market. Also, the result of valid purifying amount test for each of five products of appropriate product and inappropriate product based on filter quality test showed average 4,440 liters for appropriate product and average 2,620 liters for inappropriate product. According to the result, it is shown that the filter with good adsorption also had good chloroform removal efficiency and adsorption efficiency. Therefore, it is expected that customers can screen good quality product through obligatory conduct of filter quality test. However, it is considered that complementation in system is required for future inspection.

A Study on Water Supply Plans for Horticulture and Livestock Complexes within the Saemangeum Area (새만금 원예·축산단지 용수공급 방안 연구)

  • Choi, Kyung-Sook;Kim, Hae-Do
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.3
    • /
    • pp.125-132
    • /
    • 2012
  • Saemangeum development project is the world's largest tidal flat reclamation project. It is currently under construction, and proceeding with phased developments. The construction of agricultural areas within the Saemangeum reclamed lands is also a part of this project. These areas will have multi-functional complexes aiming to produce mainly eco-friendly horticultural crops and livestock products for the purpose of export. The major concern is to obtain sufficient water with appropriate quality to supply to those areas. The objective of this study is therefore to provide available water supply plans for agricultural purpose, especially for horticulture and livestock complexes. Alternative methods for water supply are purifying water from the Saemangenm lake or using water supply services providing by K-water or local governments. This study investigates to find an economical water supply plan through comparisons of these methods. As a result, the water purification method with Saemangeum lake water could be advantageous for given water supply conditions to horticulture and livestock complexes.

The Infiltration Velocity of a Sewage Disposal System with Water Plant and Gravel Bed (수초·골재 하수처리장의 투수속도)

  • Chung, Dong Yang
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.3
    • /
    • pp.29-34
    • /
    • 2003
  • This paper describes the effects of sewage amount, temperature, and years in operation on the infiltration rate of a sewage disposal system. The self-purifying sewage disposal system, which is typically used in rural areas, consists of reeds and fine gravel. Water plants are planted on the gravel bed which provides the habitat for microbes. The basic process is that the gravel bed filters incoming sewage. Thus this system requires the smooth flow of sewage through the gravel. However, the efficiency of the disposal system will be lowered if the gravel bed is clogged with sewage sludge. A three year study shows that infiltration rate slows down significantly until the 7th day, depending on the sewage amount and the temperature. After the 7th day, the infiltration rate remains almost constant. In addition, the infiltration rate decreases as the temperature falls. It also decreases as the number of years in operation increase. But there is no significant change in the infiltration rate after the 7th day, independent of the temperature, the sewage amount, and years in operation. In order to take advantage of high infiltration rate, which improves the efficiency of the disposal system in its early stages, having two gravel beds and using them alternatively will be efficient. This operation method is called intermittent load and makes the disposal system last longer. The water plant roots above the gravel bed make the effective filtration possible because they delay accumulation of the sewage sludge and stabilize the filtration ability.

A Study on the Dosage ate Control of the Pre-Chorine in Water Purification using Fuzzy Inference Technique (퍼지 론기법 정수공정의 전염소주입율 제어에 관한 연구)

  • 이상석;소명옥;이준탁
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.2 no.1
    • /
    • pp.89-95
    • /
    • 1996
  • This paper describes a fuzzy controlled pre-chlorination technique for purifying the pulluted raw water in water purification lants. For the purpose of obtaining the high quality water, the appropriate pre-chlorine dosage rate has to be continuously adjusted according to a change in quality of a intake raw water, weather, solar nergy mount, temperature and etc. Therefore, the method of expressing an expert's empirical knowledge cumulated from his past carrier by fuzzy reasoning and the fuzzy controller design technique is necessary.In this paper fuzzy membership functions and rules accordingto emprircal knowledge and experimental field data were obtained, And also fuzzy cintriller design using four feedforward components for the determination of pre-chlorine dosage rate and four feedback ones for the compensation of its dosage rate with residual chlorine and its change rate, was executed.

  • PDF

Comparison of Electrocoagulation and Chemical Coagulation in Removal on Water Treatment (정수처리에서 전기응집과 화학응집의 처리효율 비교)

  • Han, Moo-Young;Song, Jae-Min;Park, Sang-Cheol
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.689-695
    • /
    • 2004
  • Electrocoagulation has been suggested as a promising alternative to conventional coagulation. The process is characterized by reduced sludge production, no requirement for chemical use, and ease of operation. However, this coagulation has scarcely been studied in water purifying process. This study was performed several batch experiments to compare turbidity removal between electrocoagulation and chemical coagulation. In addition, characteristics of floe were evaluated with zeta potential and particle size distributions. Electrocoagulation showed a relatively higher removal of turbidity (approximately 5%) with the same aluminum amount than conventional chemical coagulation. In addition, turbidity removal by electrocoagulation was less sensitive to pH and was greater for more extensive pH range than chemical coagulation. The results of zeta potential and floc size distributions illustrated that electrocoagulation provided the preferable conditions for coagulation such as zeta potential close to zero millivolt and increased portions of particles in the range of 40 and $100{\mu}m$.

The model on Formation of Trihalomethane in Purifying Process of Drinking Water (정수처리긍정에서 소독부산물인 트리할로메탄의 생성모델)

  • 이성식;성낙창;이종팔;박현석;정미은;이상준;윤태경
    • Journal of Environmental Science International
    • /
    • v.13 no.3
    • /
    • pp.297-300
    • /
    • 2004
  • We have been proposed model equation which is able to predict the trihalomethane producing concentration formation, that is one of byproduct, in the water treatment processes. In proposed model, the effects of trihalomethane factors like chlorine contact time, pH, temperature, TOC and UV-254 are considered. The concentration of the trihalomethane produced is proportion to the contact with chlorine, pH of water, temperature of water TOC and UV-254, respectively. This proposed model could be predicted the formed concentration of trihalomethanes by trihalomethane factors.