• Title/Summary/Keyword: water vapour transfer

Search Result 15, Processing Time 0.024 seconds

The Water Vapour Transfer on Outdoor Activities Clothing (야외 운동복에서의 수분전달)

  • Oh, Ae-Gyeong
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2001.10a
    • /
    • pp.115-118
    • /
    • 2001
  • The water vapour permeability of clothing materials is a critical property for clothing systems that must maintain thermal equilibrium for the wearer. The evaporation of perspiration provides the means of cooling the human body. The perspiration should evaporate from the surface of the skin and pass as water vapour through the clothing, which must be permeable for comfort. The primary objectives in this study of the transfer through fabrics of water vapour are to measure this property in a quantitative manner appropriate to clothing systems and to provide an increased understanding of various types of fabric in water vapour transfer. (omitted)

  • PDF

Water Vapour Transfer through Fabrics for Outdoor Activities (야외 운동복용 직물에서의 수분전달)

  • O, Ae Gyeong;Park, Jeong Wan
    • Textile Coloration and Finishing
    • /
    • v.15 no.3
    • /
    • pp.66-66
    • /
    • 2003
  • 야외 운동(outdoor activities)복에 사용되는 소재들은 외부로부터 신체를 안전하게 보호해 주어야 될 뿐 아니라 쾌적하게 유지시켜 주어야 한다. 의복착용시 쾌적감에 결정적인 영향을 미치는 인자는 몸의 열적 평형상태를 유지하기 위한 수단인 수분전달 특성이다. 본 연구는 여러 종류의 야외 운동복용 직물에서의 수분전달 현상을 조사하여 규명하므로써 이 직물들이 실제 의복생활에 응용될 의복계 (clothing system)를 형성하였을 때의 수분전달 현상을 설명하고자 하는 기초연구이다. 연구의 결과는 base layer용, mid layer용 직물들이 shell layer로 쓰이는 waterproof breathable 직물보다 수분 전달률이 높았으며, waterproof breathable 직물의 수분 전달률은 microfibre 직물, PTFE-laminated 직물 그리고 polyurethane coated 직물 순 이었다. 또한 polyurethane 직물에서는 back coated 직물이 face-coated 직물보다 수분 전달률이 높았다.

Water Vapour Transfer through Fabrics for Outdoor Activities (야외 운동복용 직물에서의 수분전달)

  • Oh, Ae-gyeong;Park, Jung-whan
    • Textile Coloration and Finishing
    • /
    • v.15 no.3
    • /
    • pp.192-196
    • /
    • 2003
  • 야외 운동(outdoor activities)복에 사용되는 소재들은 외부로부터 신체를 안전하게 보호해 주어야 될 뿐 아니라 쾌적하게 유지시켜 주어야 한다. 의복착용시 쾌적감에 결정적인 영향을 미치는 인자는 몸의 열적 평형상태를 유지하기 위한 수단인 수분전달 특성이다. 본 연구는 여러 종류의 야외 운동복용 직물에서의 수분전달 현상을 조사하여 규명하므로써 이 직물들이 실제 의복생활에 응용될 의복계(clothing system)를 형성하였을 때의 수분전달 현상을 설명하고자 하는 기초연구이다. 연구의 결과는 base layer용, mid layer용 직물들이 shell layer로 쓰이는 waterproof breathable 직물보다 수분 전달률이 높았으며, waterproof breathable 직물의 수분 전달률은 microfibre 직물, PTFE-laminated 직물 그리고 polyurethane coated 직물 순 이었다. 또한 polyurethane 직물에서는 back coated 직물이 face-coated 직물보다 수분 전달률이 높았다.

Study Characteristics in Packed Tower of Liquid Desiccant Solar Cooling System Using Counter Flow Configuration

  • Rahmanto, R. Hengki;Choi, K.H.;Agung, B.;Sukmaji, I.C.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.168-174
    • /
    • 2009
  • High water vapour content in air can cause a number of problems as for human or surrounding materials. For human a high water vapour can create physiological stress, discomfort, and also can encourage ill health. While, the cause for the environment is can accelerate the corrosion of metals, accelerate the growth of spores and mould, can reduce the electrical resistance of insulators and etc. Desiccant systems have been proposed as energy saving alternatives to vapor compression air conditioning for handling especially the latent load and also sensible load. Use of liquid desiccants offers several design and performance advantages over solid desiccants, especially when solar energy is used for regeneration. The liquid desiccants contact the gas inside the packed tower of liquid desiccant solar cooling system and the heat transfer and mass transfer will occur. This thesis is trying to study the characteristics inside the packed tower of dehumidifier systems. This characteristics consist of mass transfer rate, heat transfers rate, human comfort and energy that consume by the system. Those characteristics were affected by air flow rates, air temperature and humidity, and desiccant temperature and all that variation will influence the performance of the systems. The results of this thesis later on can be used to determine the best performance of the systems.

  • PDF

Effects of the Moisture on the Overall Heat Transfer Through Heat Insulators Opaque Envelopes (불투명 외피의 열관류에서 단열재의 습도영향)

  • Lee, S.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.63-69
    • /
    • 1998
  • The heat conduction and the water vapour diffusion flow through heat insulators between hygroscopical moist building materials were measured by means of the plate method. It was found that the heat transport increases with a moisture motion occuring in the temperature drop. On his basis of simplified assumptions, the increase in the thermal conductivity was calculated from the rate of diffusion flow per unit area, which generally resulted in values inferior to the measured values. The Increase in the heat transport due to water vapour diffusion measured at a large-scale wall specimen was inferior to the one measured by means of the plate method by using a comparable arrangement of layers. The overall heat transfer caused by moisture motion is not a characteristic value of the material, but a property of the whole wall structure

  • PDF

A Six-Layer SVAT Model for Energy and Mass Transfer and Its Application to a Spruce(Picea abies [L].Karst) Forest in Central Germany (독일가문비나무(Picea abies [L].Karst)림(林)에서의 Energy와 물질순환(物質循環)에 대(對)한 SLODSVAT(Six-Layer One-Dimensional Soil-Vegetation-Atmosphere-Transfer) 모델과 그 적용(適用))

  • Oltchev, A.;Constantin, J.;Gravenhorst, G.;Ibrom, A.;Joo, Yeong-Teuk;Kim, Young-Chai
    • Journal of Korean Society of Forest Science
    • /
    • v.85 no.2
    • /
    • pp.210-224
    • /
    • 1996
  • The SLODSVAT consists of interrelated submodels that simulate : the transfer of radiation, water vapour, sensible heat, carbon dioxide and momentum in two canopy layers determined by environmental conditions and ecophysiological properties of the vegetation ; uptake and storage of water in the "root-stem-leaf" system of plants ; interception of rainfall by the canopy layers and infiltration and storage of rain water in the four soil layers. A comparison of the results of modeling experiments and field micro-climatic observations in a spruce forest(Picea abies [L].Karst) in the Soiling hills(Germany) shows, that the SLODSVAT can describe and simulate the short-term(diurnal) as well as the long-term(seasonal) variability of water vapour and sensible heat fluxes adequately to natural processes under different environmental conditions. It proves that it is possible to estimate and predict the transpiration and evapotranspiration rates for spruce forest ecosystems on the patch and landscape scales for one vegetation period, if certain meteorological, botanical and hydrological information for the structure of the atmospheric boundary layer, the canopy and the soil are available.

  • PDF

A Study on the Heat Transfer Characteristics of Rotating Heat Pipe with the Water-Ethanol Mixture as Working Fluid (물-에탄올 혼합물을 작동유체로 한 회전형 히트파이프의 전열 특성에 관한 연구)

  • Park, Choon-Kun;Jun, Chul-Ho;Seo, Hae-Sung
    • Solar Energy
    • /
    • v.11 no.1
    • /
    • pp.78-86
    • /
    • 1991
  • Heat transfer characteristics of a rotating heat pipe have been studied numerically and experimentally with using water-ethanol mixture as working fluid. And triangular fins are attached inside the rotating heat pipe. Experimental results generally agreed with numerical results. According to increasing rpm and vapour pressure of the rotating heat pipe, the heat transfer rate increased. And also according to decreasing the concentration of ethanol, the heat transfer rate increased. In the case of using the pure ethanol as working fluid, the heat transfer rate was about 80% of using distilled water. The heat transfer rate and operating temperature difference of the rotating heat pipe was much influenced by ethanol concentration, and the optimum ethanol concentration was 0.2.

  • PDF

Numerical investigation of two-phase natural convection and temperature stratification phenomena in a rectangular enclosure with conjugate heat transfer

  • Grazevicius, Audrius;Kaliatka, Algirdas;Uspuras, Eugenijus
    • Nuclear Engineering and Technology
    • /
    • v.52 no.1
    • /
    • pp.27-36
    • /
    • 2020
  • Natural convection and thermal stratification phenomena are found in large water pools that are being used as heat sinks for decay heat removal from the reactor core using passive heat removal systems. In this study, the two-phase (water and air) natural convection and thermal stratification phenomena with conjugate heat transfer in the rectangular enclosure were investigated numerically using ANSYS Fluent 17.2 code. The transient numerical simulations of these phenomena in the full-scale computational domain of the experimental facility were performed. Generation of water vapour bubbles around the heater rod and evaporation phenomena were included in this numerical investigation. The results of numerical simulations are in good agreement with experimental measurements. This shows that the natural convection is formed in region above the heater rod and the water is thermally stratified in the region below the heater rod. The heat from higher region and from the heater rod is transferred to the lower region via conduction. The thermal stratification disappears and the water becomes well mixed, only after the water temperature reaches the saturation temperature and boiling starts. The developed modelling approach and obtained results provide guidelines for numerical investigations of thermal-hydraulic processes in the water pools for passive residual heat removal systems or spent nuclear fuel pools considering the concreate walls of the pool and main room above the pool.

An experimental study on heat transfer characteristics of variable conductance heat pipe (가변전열 히이트 파이프의 특성에 관한 연구)

  • 김주년;이영호;김용모
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.4-16
    • /
    • 1984
  • The heat-pipe is characterised by the highly effective thermal conductance. In order to change the thermal conductance, the heat-pipe is connected to a reservior having a space which is filled with non-condensable gas. In normal operation, the vapour of working fluid will tend to pump the non- condensable gas into the reservoir and the gas-vapour interface situates at some point along the condenser section. The thermal conductance is affected by non- condensable gas. It is concluded that the suitable position of interface can be used to control the temperature of condenser section. In this experiment, the evaporating part is connected to the lowest position of heat-pipe. The copper heat-pipe which is filled with Freon-113 or distilled water as working fluid utilized. As results of experimental study, thermal conductance can be increased by the operating pressure which is infulenced by non-condensable gas. A correlative equation between the thermal conductance and the mass of non- condensable gas is also obtained.

  • PDF

Absolute Atmospheric Correction Procedure for the EO-1 Hyperion Data Using MODTRAN Code

  • Kim, Sun-Hwa;Kang, Sung-Jin;Chi, Jun-Hwa;Lee, Kyu-Sung
    • Korean Journal of Remote Sensing
    • /
    • v.23 no.1
    • /
    • pp.7-14
    • /
    • 2007
  • Atmospheric correction is one of critical procedures to extract quantitative information related to biophysical variables from hyperspectral imagery. Most atmospheric correction algorithms developed for hyperspectral data have been based upon atmospheric radiative transfer (RT) codes, such as MODTRAN. Because of the difficulty in acquisition of atmospheric data at the time of image capture, the complexity of RT model, and large volume of hyperspectral data, atmospheric correction can be very difficult and time-consuming processing. In this study, we attempted to develop an efficient method for the atmospheric correction of EO-1 Hyperion data. This method uses the pre-calculated look-up-table (LUT) for fast and simple processing. The pre-calculated LUT was generated by successive running of MODTRAN model with several input parameters related to solar and sensor geometry, radiometric specification of sensor, and atmospheric condition. Atmospheric water vapour contents image was generated directly from a few absorption bands of Hyperion data themselves and used one of input parameters. This new atmospheric correction method was tested on the Hyperion data acquired on June 3, 2001 over Seoul area. Reflectance spectra of several known targets corresponded with the typical pattern of spectral reflectance on the atmospherically corrected Hyperion image, although further improvement to reduce sensor noise is necessary.