• Title/Summary/Keyword: water vapor flux

Search Result 122, Processing Time 0.027 seconds

A Numerical Study for the Maximizing Water Vapor Flux and Thermal Efficiency in Direct Contact Membrane Distillation (DCMD) Process (직접 접촉식 막증류 공정에서 담수 투과량 및 열효율 극대화를 위한 수치적 연구)

  • Kim, Sang-Hun;Lee, Jung-Gil;Kim, Woo-Seung
    • Membrane Journal
    • /
    • v.22 no.5
    • /
    • pp.369-380
    • /
    • 2012
  • A one-dimensional numerical model based on the energy and mass equations have been developed to predict the trans membrane water vapor flux and thermal efficiency under various operating conditions in Direct Contact Membrane Distillation (DCMD) process. The model validation have been carried out by experimental data from literature and showed good agreement. The effect of operating parameters such as brine inlet temperature and velocity, and distillate inlet temperature and velocity to increase water vapor flux and thermal efficiency were predicted by the steady-state model. The results showed that the inlet temperature and velocity in brine side are dominant factors to control the water vapor flux and thermal efficiency because the effect of inlet temperature and velocity in brine side showed the higher water vapor flux and thermal efficiency than that of inlet temperature and velocity in distillate side. The water vapor flux was increased 3.4 times in the range of 21.22 $kg/m^2h$ to 71.26 $kg/m^2h$ and the thermal efficiency was increased 37.5% in that of 0.556 to 0.765 with increasing brine inlet temperature from $60^{\circ}C$ to $95^{\circ}C$. Meanwhile, the water vapor flux was increased 30% in that of 27.91 $kg/m^2h$ to 36.33 $kg/m^2h$ and thermal efficiency increased 7.5% in that of 0.6 to 0.646 as the brine inlet velocity was increased from 60 m/h to 300 m/h.

On the Effect of Tube Attenuation on Measuring Water Vapor Flux Using a Closed-path Hygrometer (폐회로 습도계를 이용한 수증기 플럭스 관측시관의 감쇠 효과에 관하여)

  • Hong Jinkyu;Kim Joon;Choi Taejin;Yun Jin-il;Tanner Bert
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.2 no.3
    • /
    • pp.80-86
    • /
    • 2000
  • Eddy covariance method is widely used in measuring vertical fluxes of mass and energy between the atmosphere and the biosphere. In this method, scalar concentration is measured with either open-path or closed-path sensors. For the latter, fluctuations of scalar concentration are attenuated as the sample travels through a long tube, resulting in flux loss. To quantify this tube attenuation, water vapor concentrations measured with both closed-path and open-path sensors were analyzed. Our statistical analysis showed that the power spectral density obtained from the closed-path sensor was different from that from the open-path sensor in the frequency range of > 0.5 Hz. The loss of water vapor flux due to tube attenuation was < 5% during midday. At nighttime, however, the flux loss increased significantly because of the low wind speeds and the weak turbulence sources. Theoretical calculation for the tube attenuation showed a small bias in high frequency range probably because of the interaction of sticky water vapor with a tube wall.

  • PDF

The Characteristics of Diurnal Changes in the Tissue-Water Relations of Pueraria thunbergiana (칡(Pueraria thunbergiana) 조직수분관계의 일변화 특성)

  • 박용목;최창렬
    • The Korean Journal of Ecology
    • /
    • v.21 no.1
    • /
    • pp.89-96
    • /
    • 1998
  • The diurnal changes of the stomatal conductance, transpiration and leaf water potential were measured in order to assess the water relations characteristics of Pueraria thunbergiana in August of 1995 and 1996. The results showed two different responses depending on the duration of rainless days. The microclimatic conditions were highly stressful on 2 August. Daily maximum temperature reached to $39.0{\circ}C$ and vapor pressure deficit was 3.55 KPa. During this time the leaf water potential decreased to -1.02 MPa and a marked reduction of stomatal conductance was shown. However, on 15 August the stomatal conductance increased with increment of photon flux density, and transpiration was highly maintained during the day time. Minimum leaf water potential was only -0.47 MPa in spite of high transpiration rate. Furthermore, on 15 August reduced leaf water potential during the day time was recovered rapidly with decrease of photon flux density, whereas recovery of leaf water potential on 2 August was delayed. However, reduced leaf water potential on 2 August was recovered untile the next dawn. Osmotic potential at turgor loss point of Pueraria thunbergiana on 2, 3 and 15 August was -1.79, -1.70 and -1.60 MPa, respectively. The vapor pressure deficit is more contributive to the regulation of stomatal conductance than leaf water potential.

  • PDF

Evaporation Pressure Drop Characteristics with R-22 in the Plate and Shell Heat Exchangers

  • Park, Jae-Hong;Seo, Moo-Gyo;Lee, Ki-Baik;Kim, Young-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.3
    • /
    • pp.129-137
    • /
    • 2002
  • In this study, evaporation pressure drop experiments were conducted with two types of plate and shell heat exchangers (P&SHE) using R-22. An experimental refrigerant loop has been established to measure the evaporation pressure drop of R-22 in a vertical P&SHE. The flow channels were formed by stacking three plates having a corrugated channel of a chevron angle of 45 dog. The R-22 flows down in one channel exchanging heat with the hot water flowing up in the other channel. The effect of the refrigerant mass flux, average heat flux, system pressure and vapor quality were explored in detail. During the experiment, the quality change between the inlet and outlet of the refrigerant channel ranges from 0.03 to 0.15. The present data showed that two types of P&SHE have similar trends. The pressure drop in-creases with the vapor quality for both types of P&SHE. At a higher mass flux, the Pressure drop is higher for the entire range of the vapor quality. Also, the increase in the average heat flux increases the pressure drop. Finally, at a higher system pressure, the pressure drop is found to be slightly lower compared to the lower system pressure.

An Experimental Study on Pressure drop Characteristics in Plate and Shell Heat Exchanger (Plate and Shell 열교환기내의 R-22 응축압력강하 특성에 관한 실험적 연구)

  • 이기백;서무교;박재홍;김영수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.6
    • /
    • pp.1220-1227
    • /
    • 2001
  • The condensation pressure drop fur refrigerant R-22 flowing in the plate and shell heat exchanger were investigated experimentally in this study. Two vertical counterflow channels were formed in the exchanger by three plates of commercial geometry with a corrugated trapezoid shape of a chevron angel of $45^{\circ}$. The condensing R-22 flowing down in one channel exchanges heat with the cold water flowing up in the other channel. The effects of the mean vapor quality, mass flux, average imposed heat flux and system pressure of R-22 on the pressure drop were explored in detail. The quality change of R-22 between the inlet and outlet of the refrigerant channel ranges from 0.03 to 0.05. The present data showed that pressure drop increases with the vapor quality. At a higher mass flux, pressure drop is higher for the entire range of the vapor quality. Also, a rise in the average imposed heat flux causes an slight increase in the Pressure drop. Finally, at a higher system pressure the pressure drop is found to be slightly lower. Correlation is also provided for the measured pressure drops in terms of the friction factor.

  • PDF

판각형 열교환기 내의 R-22 증발 압력강하 특성에 관한 실험적 연구

  • 서무교;박재홍;김영수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.930-938
    • /
    • 2001
  • In this study, evaporation pressure drop experiments were conducted with two types of plate and shell heat exchangers (P&SHE) using R-22. An experimental refrigerant loop has been established to measure the evaporation pressure drop of R-22 in a vertical P&SHE. The flow channels were formed by adding three plates having a corrugated channel of a chevron angle of $45^{\circ}$. The R-22 flows down in one channel exchanging heat with the hot water flowing up in the other channel. The effect of the refrigerant mass flux, average heat flux, system pressure and vapor quality were explored in detail. During the experiment, the quality change between the inlet and outlet of the refrigerant channel ranges from 0.03 to 0.15. The present data showed that two types of P&SHE have similar trends. The pressure drop increases with the vapor quality for both types of P&SHE. At a higher mass flux, the pressure drop is higher for the entire range of the vapor quality. Also, the increase in the average heat flux increases the pressure drop. Finally, at a higher system pressure, the pressure drop is found to be slightly lower.

  • PDF

A Theoretical Model of Critical Heat Flux in Flow Boiling at Low Qualities

  • Kim, Ho-Young;Kwon, Hyuk-Sung;Hwang, Dae-Hyun;Kim, Yongchan
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.7
    • /
    • pp.921-930
    • /
    • 2001
  • A new theoretical critical heat flux (CHF) model was developed for the forced convective flow boiling at high pressure, high mass velocity, and low quality. The present model for an intermittent vapor blanket was basically derived from the sublayer dryout theory without including any empirical constant. The vapor blanket velocity was estimated by an axial force balance, and the thickness of vapor blanket was determined by a radial force balance for the Marangoni force and lift force. Based on the comparison of the predicted CHF with the experimental data taken from previous studies, the present CHF model showed satisfactory results with reasonable accuracy.

  • PDF

Improvement of the subcooled boiling model using a new net vapor generation correlation inferred from artificial neural networks to predict the void fraction profiles in the vertical channel

  • Tae Beom Lee ;Yong Hoon Jeong
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4776-4797
    • /
    • 2022
  • In the one-dimensional thermal-hydraulic (TH) codes, a subcooled boiling model to predict the void fraction profiles in a vertical channel consists of wall heat flux partitioning, the vapor condensation rate, the bubbly-to-slug flow transition criterion, and drift-flux models. Model performance has been investigated in detail, and necessary refinements have been incorporated into the Safety and Performance Analysis Code (SPACE) developed by the Korean nuclear industry for the safety analysis of pressurized water reactors (PWRs). The necessary refinements to models related to pumping factor, net vapor generation (NVG), vapor condensation, and drift-flux velocity were investigated in this study. In particular, a new NVG empirical correlation was also developed using artificial neural network (ANN) techniques. Simulations of a series of subcooled flow boiling experiments at pressures ranging from 1 to 149.9 bar were performed with the refined SPACE code, and reasonable agreement with the experimental data for the void fraction in the vertical channel was obtained. From the root-mean-square (RMS) error analysis for the predicted void fraction in the subcooled boiling region, the results with the refined SPACE code produce the best predictions for the entire pressure range compared to those using the original SPACE and RELAP5 codes.

Separation of Alcohol/water Mixtures with Surface-modified Alumina Membrane in Vapor Permeation (표면개질 알루미나막의 증기투과에 의한 알코올의 분리)

  • 이상인;오한기;이광래
    • Membrane Journal
    • /
    • v.10 no.3
    • /
    • pp.121-129
    • /
    • 2000
  • The membrane requires both high in selectivity and flux. However, the permselective membrane has low flux. In this study, the porous alumina membrane was coated with silane coupling agent in order to enhance the flux with proper selectivity. The contact angle of water to the surface-modified alumina membrane was greater than 90$^{\circ}$, which indicated the high hydrophobicity. The modified membrane was tested in vapor permeation for the concentration of aqueous ethanol, isopropanol, and n-butanol. With the increase of ethanol, isopropanol, butanol concentration in the feed, permeation flux increased due to the greater affinity of ethanol, isopropanol, butanol with surface-modified alumina membrane than that of water. The experimental results showed that the permeation tate of surface-modified alumina membrane was 20~1000 times greater than that of a polymer membranes.

  • PDF

Water Vapor Transmission for T800/AD6005 Based Composite Motor Case (T800/AD6005계 복합재 연소관의 습기 투과에 관한 연구)

  • 박명규;류백능;최영보;도영대
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.2 no.1
    • /
    • pp.50-58
    • /
    • 1998
  • Water vapor transmission was tested in water bath controlled by $20^{\cire}C$, 90%RH for T800/AD6005 based composite motor case which made by filament winding method. We detected internal relative humidity of composite motor case by inserting the humidity detector through the head of motor case for the study of humidity transmission through the wall of composite motor case. We found out that this composite material appears the water vapor flux of 2.88${\times}$$10^{-9}$g/$\textrm{m}^2$sec and diffusivity of 7.98${\times}$$10^{-7}$$\textrm{mm}^2$/sec at $20^{\cire}C$, 90%RH water vapor condition.

  • PDF