• Title/Summary/Keyword: water treatment plant sludge

Search Result 225, Processing Time 0.02 seconds

Optimum Pre-treatment Method in Constructed Wetlands by Natural Purification Method for Treating Livestock Wastewater (자연정화공법에 의한 인공습지에서 효과적인 축산폐수처리를 위한 최적 전처리방법 구명)

  • Park, Jong-Hwan;Seo, Dong-Cheol;Kim, Ah-Reum;Kim, Sung-Hun;Lee, Seong-Tea;Jeong, Tae-Uk;Choi, Jeong-Ho;Lee, Sang-Won;Cho, Ju-Sik;Kim, Hyun-Ook;Heo, Jong-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.3
    • /
    • pp.425-433
    • /
    • 2011
  • In order to obtain optimum pre-treatment methods and improve T-N and T-P removal efficiencies, removal rates of pollutants in small-scale livestock wastewater treatment apparatus with water plant filtration bed or activated sludge tank were investigated. Based on the results from the optimum pre-treatment in small-scale livestock wastewater treatment apparatus, removal efficiencies of pollutants in livestock wastewater treatment plant with water plant filtration and activated sludge beds. The removal rates of COD, SS, T-N, and T-P in effluent were 83, 89, 63 and 87% in small-scale livestock wastewater treatment apparatus with water plant filtration bed, respectively. The removal rates of COD, SS, T-N, and T-P in effluent were 96, 95, 86 and 92% in small-scale livestock wastewater treatment apparatus with activated sludge tank, respectively. For increasing the COD, SS, T-N, and T-P removals in small-scale livestock wastewater treatment apparatus, the water plant filtration and activated sludge beds are recommended. In livestock wastewater treatment plant with water plant filtration ($1^{st}$ treatment) and activated sludge ($2^{nd}$ treatment) beds, the concentrations of COD, SS, T-N, and T-P in effluent were 39, 15, 42 and $1mg\;L^{-1}$, respectively. It was shown that the concentrations of COD, SS, T-N, and T-P met acceptable effluent quality standard for livestock wastewater. Based on the above results, the removal rates of COD, SS, T-N, and T-P in effluent were over 99.8, 99.9, 99.2, and 99.9% in livestock wastewater treatment plant, respectively.

Effect of sludge concentration on sludge dewaterability and cake clogging analysis (슬러지의 탈수성(脫水性)에 대한 농도(濃度)의 영향(影響)과 케이크 폐색현상(閉塞現象)의 해석(解析))

  • Kwon, Jae Hyun;Park, Chung Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.1
    • /
    • pp.85-95
    • /
    • 1996
  • Although the specific resistance to filtration is the most frequently employed means for characterizing dewaterability of a sludge, it presently is not possible to design nor to prediet performance of dewatering facilities using traditional linearized parabolic filtration equation, that is, the specific resistance model because of theoretical and practical inadequacies of the concept. Limitations of the specific resistance model reflect the need to examine fundamental sludge properties and filtration behaviors affecting dewaterability. From this study, two major limitations of the specific resistance model were noted. First, specific resistance values are very dependent on the sludge concentration because of the variations of particle size distribution and cake clogging to occur when surface area mean diameter is less than $25{\mu}m$ for activated sludge, $18{\mu}m$ for water treatment plant sludge. Second, nonparabolic filtration behavior can result from cake clogging, caused by the migration of fine particles into the cake pores, accelated by skin effect with highly compressible sludges.

  • PDF

Characteristics of Sludge Bulking Caused by Low Dissolved Oxygen in Aeration Tank for Paper Mill Wastewater Treatment (포기조의 낮은 용존산소로 인한 제지폐수의 슬러지 팽화특성)

  • Kwak, Dong-Heui;Yoo, Seung-Joon;Park, Jong-Chun
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.4
    • /
    • pp.458-464
    • /
    • 2008
  • Bulking phenomena and scum formation are common problem in suspended growth system like the activated sludge plants for wastewater treatment. Apart from wastewater composition, operating conditions, such as mechanical stress by insufficient oxygen supply, are often decisive for the occurrence of a bulking or scumming problem. There were the comparative aeration tanks in terms of sludge bulking caused by the difference of mechanical aeration facilities in the wastewater treatment plant of N paper mill company. In this study the cause of bulking was investigated through not only the biological isolation and identification but also a series of operational data consideration. On the basis of the investigation results for bulking cause, the operational criteria on dissolved oxygen concentration was derived to decrease the bulking problem.

A Study on the Standardization of Activated Sludge Use to Biodegraded Linear Alkylbenzene Sulfonate (Linear Alkylbenzene Sulfonate의 생분해에 이용되는 활성오니의 표준화에 관한 연구)

  • Sun, Yle-Shik;Jung, Il-Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.31-40
    • /
    • 1992
  • This study is on the biodegradability of the activated sludge, which used to biodegrade Linear Alkylbenzene Sulfonate(LAS), synthetic detergents and sufactants. The activated sludge in waste water treatment plant is used to the test of biodegradation of anionic surfactants and nonionic surfactants, but it have the periodic change of the biological propety to the lapse of the time. For the puropse of controlling and adjusting of the activated sludge in biodegradation test, we collected microorganisms from the sewage plant and the soil, and then, made the activated sludge in semicontinuous aeration chamber. From determined biodegradation data, and the degree of biodegradability to the LAS, we confirmd the standardized synthetic activated sludge which have more stable biodegradability than the sewage activated sludge. In continuous biodegradation test, LAS(dodecene-1) was biodegraded more than 99%, In 7days by the standardized activated sludge.

A Study on the Municipal Wastewater Treatment Using Biofilm Process (생물막공법을 이용한 도시하수처리에 관한 연구)

  • Kwak, Byung Chan;Tak, Seong Jae;Kim, Nam Cheon;HWang, Yong Woo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.1
    • /
    • pp.62-75
    • /
    • 2000
  • Most of biological treatment to remove contaminants in municipal wastewater have been conducted by activated sludge process. But, the process have several probIems such as enormous site needed for construction of treatment facilities, unstable treatment due to limited ability to control load fluctuation, frequent sludge bulking and appearance of lots of surplus sludge. In this study, the experiments were performed through submerging biofilm of PEPP media in existing aeration tank with raw water from municipal wastewater treatment plant and then submerging PVDC and PEPP media, different from shape and chemical peculiarity in anoxic reactor. Throughout the experience, nutrient removal efficiency according to HRT, nitrogen phosphorous removal efficiency, behavior of nitrogen and dewatering efficiency have been compared and analysed with those of activated sludge process. As the results, BOD removal efficiency according to BOD volumetric load and F/M ratio was not found any differency in two processes, but was decreased below 90% as going along the condition of high load in activated sludge process. Kinetic coefficient was $K_{max}=1.162day^{-1}$, $K_s=53.77mg/L$, $Y=0.166mgVSS/mgBOD_{rem}$. and $K_d=0.019day^{-1}$. It was found that the removal efficiency, even though in aerobic condition, in biofilm process equipped anoxic reactor was higher than the one in activated sludge process within the range of 70~80%, and became better as HRT increased. Phosphorous removal efficiency was not found any differency in two processes. In biofilm process, treament efficiency even in conditions of high load was not decreased, because the biomass concentration could be maintained in high condition compared with activated sludge process. As HRT increased, suspended and attached biomass was increased and the other hand, F/M ratio was decreased as biomass' increasing. Biomass thickness was increased. from $10.43{\mu}m$ to $10.55{\mu}m$ as HRT increased and density of biomass within $40.79{\sim}41.16mg/cm^2$. The results also present that the dewatering efficiency of sludge generated in biofilm process was higher than in activated sludge process, and became better as HRT increased.

  • PDF

Development of Ultrasonic Multi-Beam Sludge Meter For Effluent Facilities Automation (정수장에서 배출수 공정 자동화를 위한 초음파 다중빔 슬러지 농도계 개발)

  • Jang, Sang-Bok;Hong, Sung-Taek;Chun, Myung-Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.9
    • /
    • pp.2313-2321
    • /
    • 2014
  • A concentration meter is widely used at purification plants, sewage treatment plants and waste water treatment plants to sort and transfer high concentration sludge and to control the amount of chemical input. This study has been prepared for improving efficiency of operation on sludge processes and to establish a basic for factory automation by accuracy improvement and problem solution of sludge concentration meter. The concentration meter's accuracy and stability is improved by applying multi-beam sensors and minimum deviation linear average filtering. Furthermore maintenance without cut-off of water in sludge operation is possible by detachable sensors. The performance of multi-beam concentration meter has been variously verified by the pilot plant experiment.

Piggery Waste Treatment using Improved MLE Process in Full-Scale (수정된 MLE 공정을 이용한 Full-Scale에서의 돈사분뇨처리)

  • Hwang, In-Su;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.895-904
    • /
    • 2006
  • The improved MLE (modified Ludzack-Ettinger) process was operated for piggery waste treatment in full-scale public livestock waste treatment plant. The treated waste from bioreactor was suitable for the strict effluent standard of 200 mgCOD/L and 60 mgTN/L as it was dewatered chemically without settling tank and passed through filtration process. Though this treatment method produced a great deal of sludge ($6.4m^3\;per\;m^3$ dewatered piggery waste) it was able to accomplish predominant effluent quality by removing non-biodegradable COD and color without advanced oxidation process as ozone, fenton and etc.. The nitrogen removal efficiency of bioreactor was rapidly declined from March to May (from 0.016 to 0.005 kgN/kgVSS-day) when disinfection is in earnest as well as from warm season when reactor temperature rises higher than $35^{\circ}C$(from 0.016 to 0.008 kgN/kgVSS-day). This study proves that counterplanes for infection residuals, bioreactor temperature and dewatering sludge reduction are necessary for piggery waste treatment.

The Effect of HRT and SRT on Treatment Efficiency of Activated Sludge Process for Low Concentration Municipal Sewage (저농도 도시하수 처리를 위한 활성슬러지공정에서 HRT 및 SRT가 처리효율에 미치는 영향)

  • Whang, Gye Dae;Kim, Min Ho;Ko, Sae Bom
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.1
    • /
    • pp.64-73
    • /
    • 1997
  • Most of the municipal wastewater treatment plants operated in Korea are designed for high concentrations municipal sewage. However, activated sludge process employed by municipal wastewater treatment plant is operated at low organic loading. The objective of this study was to determine optimum operating condition of activated sludge process for treatment of low concentration municipal sewage. Three bench scale activated sludge reactors were operated to investigate the effect of HRT and SRT on the COD and TSS removal efficiency. The average concentration of TSS, SCOD, SBOD and TKN in influent were 118mg/l, 61mg/l, 21mg/l, and 12mg/l, respectively. The activated sludge reactors operated with various HRT and SRT showed about 89-93% TSS removal efficiency. HRT and SRT does not affect the TSS removal efficiency of actvatied sludge process significantly. However, HRT affected the SCOD removal efficiency slightly. As the HRT decreases from 13hours to 3hours, the SCOD removal efficiency decreases from 67% to 56%. The average effluent TCOD concentration of the reactor operated with 3hours of HRT was approximatly 40-45mg/l. Kinetic coefficient yield (Yt) and decay coefficients(Kd) were 0.594-0.954 mgMLVSS/mgCOD and $0.0197-0.0317day^{-1}$, respectively. Low concentration municipal sewage can be treated with 3 hours of HRT without effluent quality deterioration and SRT does not affect the substrate removal efficiency at this operation condition.

  • PDF

The Recovery of Alumina from Water Treatment Plant Sludge by Chlorination (정수장 슬러지로부터 염소화 반응에 의한 알루미나 회수)

  • Yeon, Ik-Jun;Lee, Sang-Woo;Kim, Kwang-Yul
    • Journal of the Korean Applied Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.211-216
    • /
    • 1999
  • This study was conducted to recover the aluminum from water treatment plant sludge containing alumina. The optimum reaction conditions about chlorination of sludge with $NH_4Cl$ are as follows: the weight ratio of sludge to $NH_4Cl$ is 4, the reaction time is 60min, and the temperature is $300^{\circ}C$. And the result of leaching time test showed that the highest yield of alumina at $160^{\circ}C$ was 96% but the result of leaching test at $160^{\circ}C$ was little better than that of leaching test at $100^{\circ}C$ while the leaching concentration of HCl was 4N. The optimum reaction conditions of chlorinated sludge with $NH_4Cl$, gave the highest yield of 95.41% based on aluminum.

Wastewater Treatment Plant Control Strategies

  • Ballhysa, Nobel;Kim, Soyeon;Byeon, Seongjoon
    • International journal of advanced smart convergence
    • /
    • v.9 no.4
    • /
    • pp.16-25
    • /
    • 2020
  • The operation of a wastewater treatment plant (WWTP) is a complex task which requires to consider several aspects: adapting to always changing influent composition and volume, ensuring treated effluents quality complies with local regulations, ensuring dissolved oxygen levels in biological reaction tanks are sufficient to avoid anoxic conditions etc. all of it while minimizing usage of chemicals and power consumption. The traditional way of managing WWTPs consists in having employees on the field measure various parameters and make decisions based on their judgment and experience which holds various concerns such as the low frequency of data, errors in measurement and difficulty to analyze historical data to propose optimal solutions. In the case of activated sludge WWTPs, parts of the treatment process can be automated and controlled in order to satisfy various control objectives. The models developed by the International Water Association (IWA) have been extensively used worldwide in order to design and assess the performance of various control strategies. In this work, we propose to review most recent WWTP automation initiatives around the world and identify most currently used control parameters and control architectures. We then suggest a framework to select WWTP model, control parameters and control scheme in order to develop and benchmark control strategies for WWTP automation.