• Title/Summary/Keyword: water treatment plant sludge

Search Result 227, Processing Time 0.031 seconds

Development of Degradation Agent for Oil Contaminated Soil using Modified Peat Moss and Organic Sludge (개량된 이탄과 유기성 슬러지를 이용한 유류오염토양 분해제 개발)

  • Kim, Soo-Hong;Lee, Chang-Han;Suh, Jung-Ho
    • KSBB Journal
    • /
    • v.25 no.1
    • /
    • pp.103-107
    • /
    • 2010
  • Oil degradation agent was developed with organic sludge and modified peat moss (MPM) to recover oil contaminated soil. Waste sludge discharged from wastewater treatment plant of chemical plant in Ulsan National Industrial Park was used as organic sludge, and MPM was purchased. Organic sludge was adequate to use as growth medium for microorganism, the surface of MPM had porous structure which could enhance the cultivation condition of oil degradation microorganisms. Water contents and TPH variation with time were observed to investigate the degradation capacity of developed degradation agent. Water contents were rapidly decreased with higher contents of MPM, however, in case of TPH, high MPM content decreased the degradation capacity. Therefore, it was recommended that the content of MPM was controlled to below 10% in degradation agent as mixing organic sludge with MPM.

A Study on Alum recovery and reuse from the sludge in water treatment plant. (상수도 정수장 오이중 Alum회수 및 재활용에 관한 연구)

  • 김관천;노기환;강영식;이치영;류일광
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.1
    • /
    • pp.86-96
    • /
    • 1995
  • Alum recovery has recently gained more attention because many water utilities need to improve their sludge handling and disposal practices. As part of an overall sludge management program recovery can reduce the amount of solids and allow for reuse of the recovered Alum as a coagulant. This study was examined the effectiveness of Alum recovery from the Sludge at the D water treatment plant in Kwangju city. The results were summarized as follows 1. Alum recovery was obtained sufficiently acidification(An optimum condition was pH2-3) With $H_{2}SO_{4}$ to settled sludge. In this case recovered liquid Alum from sludge of 2.1% solids concentration at pH 2.1 was contains Aluminum $1,602mg/{\ell}$(as $Al_{2}O_{3}$ 0.3% ) and other metal of low level. 2. It was an optimum condition to all reuse of recovered Alum as a coagulant that rate of Commercial Alum:Recovered Alum=$14{\mu}{\ell}/{\ell}{\;}:{\;}200{\mu}{\ell}/{\ell}$ In a result of Jar Tests. 3. It was a result of Alum recovery from sludge, the reduction effect of amount of solids was about 57.4%. 4. If all recovered Alum were reused the reduction effect of solid wastes disposal cost and chemical drug's cost was about 22%.

  • PDF

Convergence Study on Organic Sludge Treatment System (유기성 슬러지 처리 시스템에 관한 융합연구)

  • Han, Doo-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.10
    • /
    • pp.213-217
    • /
    • 2020
  • An eco-friendly water purifier was developed using natural minerals, plants, and sludge from water purification plants. A wastewater complex treatment system using this water purification agent was developed. The wastewater complex treatment system goes through the process of inflow of contaminated water, input of water purification agent, operation of a pressurized flotation device, sludge flotation, sludge collection and treatment water discharge. This device was applied to the removal of green algae in livestock desorption liquid, broiler washing water, factory wastewater, sewage treatment plant and pond to obtain excellent removal rate. The use of natural water purification agents for organic waste purification has not been investigated.

The Aeration to Improve Manganese and Chloroform of Effluent at Sludge Thickener of the Conventional Water Treatment Plant (정수장 슬러지 폭기가 방류수 망간 및 클로로포름에 미치는 영향)

  • Choi, Ilgyung;Beak, Inho;Jeong, Chanwoo;Lee, Sungjin;Park, Jungwook
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.2
    • /
    • pp.113-118
    • /
    • 2014
  • So many nationwide drinking water treatment plants are under much difficulties by new reinforced discharged effluent standards. Generally, the sludge at thickener should be retended for a long time during usual days. Sometime, the soluble manganese and chloroform may be formed under the anaerobic condition in the sludge thickener when the sludge retention time is longer with low turbidity. This phenomenon results in difficulties to keep regulatory level of the discharged effluent. It was necessary to improve the operation conditions and process itself in order to meet water quality standard recently reinforced. For an effort to overcome the problems, a sludge aeration was successfully implemented into the thickening process. Sludge aeration prevent particle oxidated Manganese eluting soluble de-oxidated Manganese, excrete formated Chloroform from effluent to air, and improve sludge settling through homogenized sludge particle. We aerated sludge at the conventional water treatment plant, measured Manganese and Chloroform of clarified water at upper sludge, and solid-fluid interface height of sludge in mass cylinder. As a result, contaminant's concentrations of the final effluent was much decreased : 41% of manganese, approximately 62% of chloroform and 35% of sludge volume, compared with non-aeration sludge.

Chemical Treatment of Municipal Wastewater Using Alum Sludge

  • Shin, Dae-Yewn;Moon, Ok-Ran;Yoon, Mi-Ran;Ro, Chang-Wha;Kang, Gong-Unn;Moon, Deok-Hyn;Dermatas, Dimitris
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.12a
    • /
    • pp.51-53
    • /
    • 2005
  • Disposal of waterwork sludge is important problem in WTP(water treatment plant). Purpose of this study is treated municipal waste water chemically using sludge that is produced in waterwork plant by link to reutilize waterwork sludge. Municipal waste water that use in an experiment used is produced at C university, and is SS 220 mg/L, BOD 145 mg/L, COD 160 mg/L, T-N 52 mg/L and T-P 2.6 mg/L. Used Alum, polymer coagulant and coagulant aid (diatomite, powered activated carbon) as CaO, coagulant as alkaline aid by chemical treatment medicine. In case of does slow speed agitation and stations after pours waterwork sludge in sewage and alkaline aid and coagulant at rapidly mixing the colloidal creation speed is fast and fine colloids concentration was high but settling time is shortened a little and removal rate of pollutant improved by $60{\sim}99%$.

  • PDF

A Study on Recycling Plan for the Dehydrated Sludge of Water Treatment Plant (탈수 처리된 정수장 슬러지의 재활용 방안 연구)

  • Chung Youn-In;Chang Yong-Chai;Choi Byoung-Il
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.2 s.25
    • /
    • pp.107-113
    • /
    • 2006
  • Water treatment plant sludge occurred in sedimentation and inverse wash process is generally disposed by ocean dumping or reclamation after dehydration processing using mechanical or natural dry method. Recently, ocean dumping of sludge is limited actually by London Convention. Physical, chemical, and geotechnical characteristics of water treatment plant sludge were analyzed by experiments. The possibilities for recycling of the dehydration sludges as materials for covering sanitary landfill were examined. Experiments performed with sludges mixed with general soil to improved the sludge properties are the hydrometer analysis, the liquid and plastic limit test, the specific gravity test, the compaction test, and the unconfined compression test. The value of ${\gamma}_{dmax}$ is increased and OMC(Optimum Moisture Content) is lessened with mixed sludge. The value of maximum compressive strength and friction angle are increased and the cohesion is decreased with mixed sludge. The ratio between sludge and soil in mixed sludge was 3:7 and the strength of mixed sludge showed $3.6kg/cm^2$. These results satisfy the regulation of U.S. E.P.A regarding materials for covering sanitary landfill.

  • PDF

Preparation of Composite Adsorbents by Activation of Water Plant Sludge and Phenolic Resin Mixtures

  • Myung, Heung-Sik;Kim, Dong-Pyo
    • Carbon letters
    • /
    • v.1 no.3_4
    • /
    • pp.154-157
    • /
    • 2001
  • Composite adsorbents were prepared by mixing water plant sludge with phenolic resin having the ratio of 1 : 1, 1 : 2, and 1 : 3 respectively, curing from $100^{\circ}C$ to $170^{\circ}C$ under $N_2$ atmosphere, and then activating with $N_2$ at $700^{\circ}C$. Thermal property, specific surface area and morphology of the composite adsorbents as well as their precursors were measured by TGA, BET and SEM respectively. Removal efficiency of the composite adsorbents to ${NH_4}^+$ and TOC was compared with those of commercial zeolite and activated carbon. The adsorbents presented very promising TOC removal efficiency of 98%, which was identical level to that of commercial activated carbon while they displayed removal efficiency, only 32%, of ${NH_4}^+$. Therefore, this composite adsorbent considered as the alternative material of commercial activated carbon, used as an expensive removal agent of organic substances and THM in water treatment plant and it also suggested a possibility of practical application in other processes.

  • PDF

Advanced Wastewater Treatment Process Using Aerobic Granular Sludge (AGS-SBR) (호기성 그래뉼 슬러지를 이용한 하수고도처리기술(AGS-SBR))

  • Choi, Han Na;Mo, Woo Jong
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.1
    • /
    • pp.47-54
    • /
    • 2021
  • Aerobic granular sludge (AGS) can be classified as a type of self-immobilized microbial aggregates measuring more than 0.2 mm. It offers the option to simultaneously remove COD, N, and P that occur in different zones inside a granule. Also, AGS is characterized by high precipitability, treatability with high organic loading, and high tolerance to low temperature. In this study, a sequencing batch reactor inoculated with AGS (AGS-SBR) is a new advanced wastewater treatment process that was proven to grow AGS with integrated nutrient removal and low C/N ratio. A pilot plant, AGS-SBR with a capacity of 225 ㎥/d was installed at an S sewage treatment plant in Gyeonggi-do. The results of the operation showed that the water quality of the effluent indicated that the value of BOD5 was 1.5 mg/L, CODMn was 11.4 mg/L, SS was 6.2 mg/L, T-N was 13.2 mg/L, and T-P was 0.197 mg/L, and all of these values reliably satisfied an effluent standard (I Area). In winter, the T-N treatment efficiency at a lower temperature of less than 11℃ also showed reliability to meet the effluent standard of the I Area (20 mg/L or less). Analysis of microbial community in AGS showed a higher preponderance of beneficial microorganisms involved in denitrification and phosphorus accumulation compared with activated sludge. The power consumption and sludge disposal cost were reduced by 34.7% and 54.9%, respectively, compared to the domestic SBR type sewage treatment plant with a processing capacity of 1,000 ㎥/d or less.

Removal of Toxicity from Kraft Pulp Mill Effluents by Activated Sludge Process (활성슬러지 공정에 의한 Kraft 펄프 폐수의 독성 제거)

  • Kim, Yeong-Kwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.8 no.3
    • /
    • pp.9-18
    • /
    • 1994
  • Activated sludge pilot plant testing was conducted to determine the ability of a well-designed activated sludge treatment system to remove chromic toxicity from the bleached kraft pulp mill effluent. Removals of conventional(BOD and SS) and nonconventional(resin and fatty acids, color, AOX) pollutants were estimated. The pilot plant was operated at steady state for about 10 weeks at an F/M of 0.28 and a sludge age of 8.4 days. The average MLSS concentration was 4,309mg/l, of which volatile fraction was 57%. During the operation period, the BOD removal reaction rate(k) was determined to be 8.2/day at $30^{\circ}C$. The BOD removal was 84 percent, which was 3 to 6 percent lower than expected for full-scale treatment. The chronic toxicity of the activated sludge effluent was tested by employing both Dinnel and the BML protocols. It was found that the pilot plant could achieve in excess of 90 percent reduction in chronic echinoderm toxicity. The data show slight reduction of color and AOX across the activated sludge system. The pilot system, however, demonstrated on excellent removal of resin and fatty acids.

  • PDF

Incorporation of water sludge, silica fume, and rice husk ash in brick making

  • Hegazy, Badr El-Din Ezzat;Fouad, Hanan Ahmed;Hassanain, Ahmed Mohammed
    • Advances in environmental research
    • /
    • v.1 no.1
    • /
    • pp.83-96
    • /
    • 2012
  • The water sludge is generated from the treatment of water with alum. Disposing of sludge again to the streams raises the concentrations of aluminum oxides in water, which has been linked to Alzheimer's disease. The use of water treatment plant (WTP) sludge in manufacturing of constructional elements achieves both the economical and environmental benefits. Due to the similar mineralogical composition of clay and WTP sludge, this study investigated the complete substitution of brick clay by sludge incorporated with some of the agricultural and industrial wastes, such as rice husk ash (RHA) and silica fume (SF). Three different series of sludge to SF to RHA proportions by weight were tried, which were (25: 50: 25%), (50: 25: 25%), and (25: 25: 50%), respectively. Each brick series was fired at 900, 1000, 1100, and $1200^{\circ}C$. The physical and mechanical properties of the produced bricks were then determined and evaluated according to Egyptian Standard Specifications (E.S.S.) and compared to control clay-brick. From the obtained results, it was concluded that by operating at the temperature commonly practiced in the brick kiln, a mixture consists of 50% of sludge, 25% of SF, and 25% of RHA was the optimum materials proportions to produce brick from water sludge incorporated with SF and RHA. The produced bricks properties were obviously superior to the 100% clay control-brick and to those available in the Egyptian market.