• Title/Summary/Keyword: water treatment chemicals

Search Result 282, Processing Time 0.025 seconds

A study of struvite control using CO2 in sewage treatment process (하수처리공정에서 이산화탄소를 이용한 스트러바이트 제어에 관한 연구)

  • Han, Keumseok;Hong, Seongho;Choi, Youngjune
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.3
    • /
    • pp.261-268
    • /
    • 2018
  • Sludge transporting pipes in wastewater treatment plant are easy to be clogged with struvite when the digested sludge and dehydrated filtrate are transported through the pipes, which lowers the efficiency of sludge treatment system in a WWTP. pH is one of the most important factors in struvite formation, and carbon dioxide separated from biogas can be used to control pH and struvite formation. By controlling pH, the amount of dehydrating agent can be reduced by about 10%, which saves the budget for facility maintenance. As $CO_2$ is reused and dehydrating chemicals are saved, the approach can contribute to global warming gas reduction.

Effects of Several Chemicals Treatment for Cocoon Sericin (견층(繭層) Sericin에 대(對)한 몇 가지 화학약제(化學藥劑) 처리(處理)의 효과(效果))

  • Rhee, In Jeon;Lee, Dong Soo;Cheon, Seung Rok
    • Current Research on Agriculture and Life Sciences
    • /
    • v.3
    • /
    • pp.70-78
    • /
    • 1985
  • The purpose of this study was to find out effects of several chemicals treatment for cocoon sericin. and there was several results of use to control the solubility of cocoon sericin in water. The results obtained was summarized as follows ; The chemicals which showed the strongest accelerating power on the solubility of cocoon sericin in water was sodium peroxide ($Na_2O_2$), the second was sodium carbonate ($Na_2CO_3$), the third was sodium sulfite ($Na_2SO_3$), the weakest was ammonia water ($NH_4OH$) in order among noticed silk-reeling accelerators. The chemicals which showed the inhibiting power on the solubility of cocoon sericin in water was tannic acid ($C_{14}H_{10}O_9$), the second was stannic acid ($Sn(OH)_4$), the third was formic acid (HCOOH) and the weakest was methyl alcohol ($CH_3OH$) in order among noticed silk-reeling inhibitors. Particulary stannic acid and formic acid showed accelerating power on the solubility of cocoon sericin at high temperature over 100 degrees of celsius thermometer in water Methyl alcohol did not show the inhibiting power on the solubility of cocoon sericin in low concentration. (at 1,500-2,000 times)

  • PDF

The Analysis of Harmonics at a Inverter System of Low Voltage and the Methods for the Reduction (저압 인버터 시스템의 고조파 분석 및 저감 방안 연구)

  • Shin, Gang-Wook;Hong, Sung-Taek;Lee, Dong-Keun;Lee, Eun-Chun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.64-66
    • /
    • 2005
  • Recently, Many water treatment facilities are operated by automatic control or by remote control. These high technology control systems require more stable power supply than before. Badly most automatic control systems adopted in water treatment facilities are non-linear load which generates electrical harmonics inevitably. This study is intended to measure and analyze the electrical harmonics occurred at the chemicals control device which is inverter application circuit, and to show the Method for reduction.

  • PDF

Deterioration Mechanism of Paper according to Sizing and Beating(I)-Influences of Sizing- (사이징과 고해에 따른 종이의 열화기구(제1보)- 사이징의 영향 -)

  • 김봉용
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.30 no.2
    • /
    • pp.24-29
    • /
    • 1998
  • This study was carried out in order to elucidate the deterioration mechanism of paper according to various sizing chemicals. No additive paper and four kinds of papers containing rosin-alum, alum only, alkylketene dimer(AKD)-cation polymer and cation polymer only were treated by UV light to study changes of water-resistant, optical and mechanical properties from the view points of natural deterioration of paper. Since rosin chemicals have UV absorption at the relatively long wavelength region, rosins are degraded to form hydrophilic groups such as carboxylic acid from their double bonds by UV treatments. These phenomena caused the decreasing of sizing degree and wetting time in case of rosin-sized paper, while the UV treatments brought about the slight increase of wetting time in rosin-free papers such as no additive, alum and kymene only paper owing to the auto-sizing effect. Optical properties were primarily influenced by sizing chemicals. Rosin-sized paper showed lower brightness after UV and near UV treatment because of its UV instability.

  • PDF

Removal of a synthetic broad-spectrum antimicrobial agent, triclosan, in wastewater treatment systems: A short review

  • Lee, Do Gyun
    • Environmental Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.111-120
    • /
    • 2015
  • Contaminants of emerging concern (CECs) including endocrine disrupting compounds (EDCs) and pharmaceuticals and personal care product chemicals (PPCPs) have recently received more attention because of their occurrence in water bodies and harmful impacts on human health and aquatic organisms. Triclosan is widely used as a synthetic broad-spectrum antimicrobial agent due to its antimicrobial efficacy. However, triclosan detected in aquatic environment has been recently considered as one of CECs, because of the potential for endocrine disruption, the formation of toxic by-products and the development of cross-resistance to antibiotics in aquatic environment. This comprehensive review focuses on the regulations, toxicology, fate and transport, occurrence and removal efficiency of triclosan. Overall, this review aims to provide better understanding of triclosan and insight into application of biological treatment process as an efficient method for triclosan removal.

Simultaneous Determination and Occurrences of Pharmaceuticals by Solid-Phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) in Environmental Aqueous Samples

  • Koo, So-Hyun;Jo, Cheon-Ho;Shin, Sun-Kyoung;Myung, Seung-Woon
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1192-1198
    • /
    • 2010
  • Pharmaceuticals and personal care products (PPCPs) are emerging contaminants in the aquatic environment. Many pharmaceuticals are not completely removed during wastewater treatment, leading to their presence in wastewater treatment effluents, rivers, lakes, and ground water. Here, we developed analytical methods for monitoring ten pharmaceuticals from surface water by LC/ESI-MS/MS. For sample clean-up and extraction, MCX (mixed cation exchange) and HLB (hydrophilic-lipophilic balance) solid-phase extraction (SPE) cartridges were used. The limits of detection (LOD) in distilled water and the blank surface water were in the range of 0.006 - 0.65 and 1.66 - 45.05 pg/mL, respectively. The limits of quantitation (LOQ) for the distilled water and the blank surface water were in the range of 0.02 - 2.17 and 5.52 - 150.15 pg/mL, respectively. The absolute recoveries for fortified water samples were between 62.1% and 125.4%. Intra-day precision and accuracy for the blank surface water were 2.9% - 24.1% (R.S.D.) and -16.3% - 16.3% (bias), respectively. In surface wastewater near rivers, chlortetracycline and acetylsalicylic acid were detected frequently in the range of 0.017 - 5.404 and 0.029 - 0.269 ng/mL, respectively. Surface water near rivers had higher levels than surface water of domestic treatment plants.

Acute Toxicity Test for Wastewater from Several Drainage Canals and Discharges Using Daphnia Magna (생태독성도를 이용한 공단배수 및 공장배출수의 독성도 조사)

  • Park, Dong-Gyu;Bae, Hun-Kyun
    • Journal of Environmental Science International
    • /
    • v.20 no.7
    • /
    • pp.811-818
    • /
    • 2011
  • Daphnia Magna Stratus has been widely accepted as useful species for estimating the toxicity of chemicals to aquatic invertebrate and recommended as species for the testing chemicals from the international guideline as well as Korean guideline. The study was performed for the acute toxicity test by using water flea(D. Magna) for effluents from several wastewater treatment plants and drainage canals in GyeongBuk area. Five heavy metals, 1,4-Dioxane and Perchlorate were tested. Most Toxicity Units(TU) of Industrial wastewater effluents were less than 1 which means effluent was not toxic to D. Magna. However, effluents containing 1,4-Dioxane and Perchlorate were significantly toxic to D. Magna. Therefore, facilities should reduce the 1,4-dioxane since new regulations will force them after the year of 2011.

Fundamental Study on Developing the Technology for the Removal of Fluorescent Whitening Agents from the Process Water (공정수에 존재하는 형광증백제의 제거 기술에 대한 기초연구)

  • Lee, Ji-Young;Youn, Hye-Jung;Lee, Hak-Lae
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.41 no.1
    • /
    • pp.24-29
    • /
    • 2009
  • The use of fluorescent whitening agents (FWAs) increases as the demand for the whiter and brighter printing papers increases. FWAs are used as internal and surface treatment chemicals. FWAs that are not used properly in the papermaking process, however, remain in the process water and may demage the paper quality and processes. In this study, a new idea to eliminate FWAs from the process water, consisted of the floc formation of FWAs with cationic chemicals, such as cationic polyelectrolytes and alum, and the removal of the floc by screening or sedimentation, was proposed. Flocculation of FWAs, that is the first step to remove FWAs from the process water, was investigated using turbidity and particle size measurement. Relationship between turbidity and particle size showed that the turbidity could reflect the particle size change of FWA flocs and was proper for the evaluation of flocculation phenomena. Poly-DADMAC was more efficient than PEI to induce the flocculation of FWAs. Alum was effective chemical for the flocculation and sedimentation of FWAs.

Variation of hazardous substances in sewage ecotoxicological assessment (하수 원수내 유해물질 변화에 따른 생태독성평가)

  • Seo, Byong-Won;Lee, Ju-Hwa;Lee, Yong-Hoon;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.603-610
    • /
    • 2013
  • According to industrialization, increased toxic chemicals discharge has been causing water pollution. Especially domestic sewage is a major source of water pollution. Sixty percent of the total wastewater discharged is domestic sewage. Self-purification capacity of rivers and streams is drastically reduced by the emission of domestic sewage, industrial wastewater and livestock wastewater. Although domestic sewage is managed by implementing standards and regulations, toxicity effect of domestic sewage to humans and the environment is not yet clearly understood. In this study, by using daphnia magna, the ecotoxicity of domestic swage was assessed. Cl, Cu, Pb, COD, T-N, DO, pH and residual chlorine were investigated as background concentrations. The experiments were conducted with water samples obtained from three local sewage treatment plants. The experiment results indicated that higher level of toxicity corresponds to the higher pollution concentrations. The higher level of combinations of background concentrations such as heavy metals leads to the worse ecotoxicity. Especially, the Cu concentration affects the TU value.

A Study on Waterproofing and Anticorosive Performance Evaluation of Surface treatment material used wi th Glass Fiber, Inorganic and Organic Material for Water Tank (수조구조물의 방수.방식 공사용 유기.무기 소재 및 섬유보강형 바탕처리재의 성능평가에 관한 연구)

  • 오상근;박봉규;주웅일;박성진
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2001.11a
    • /
    • pp.70-75
    • /
    • 2001
  • There is a problem to be solved for improvement of durability and safety for concrete When the waterproofing and anticorrosive work of main concrete are design, the material a of construction need to be correctly applied to appropriate circumstance conditions. Epoxy mostly been used for concrete water tank structure. Lately, lots of subjects on adaption res in mortar for waterproofing and anticorrosive are under discussion. Then, we attempt to approach by evaluating and comparing every capabilities with waterproofing materials in this experiment. Capability evaluation items include the bond age and curing conditions, the bond strength after accelerated weathering test and fret impact resistance, a mount of water, seepage quan Through the experiment analysis, we found that waterproofingtity, drinking water chemicals resistance. and anticorrosive resin mortar used with glass fiber cloth, inorgar material is dominantly superior to other waterproofing materials. According to this paper, we suggest the resin mortar as a new surface treatment material water tank structure.

  • PDF