Pharmaceuticals and personal care products (PPCPs) are emerging contaminants in the aquatic environment. Many pharmaceuticals are not completely removed during wastewater treatment, leading to their presence in wastewater treatment effluents, rivers, lakes, and ground water. Here, we developed analytical methods for monitoring ten pharmaceuticals from surface water by LC/ESI-MS/MS. For sample clean-up and extraction, MCX (mixed cation exchange) and HLB (hydrophilic-lipophilic balance) solid-phase extraction (SPE) cartridges were used. The limits of detection (LOD) in distilled water and the blank surface water were in the range of 0.006 - 0.65 and 1.66 - 45.05 pg/mL, respectively. The limits of quantitation (LOQ) for the distilled water and the blank surface water were in the range of 0.02 - 2.17 and 5.52 - 150.15 pg/mL, respectively. The absolute recoveries for fortified water samples were between 62.1% and 125.4%. Intra-day precision and accuracy for the blank surface water were 2.9% - 24.1% (R.S.D.) and -16.3% - 16.3% (bias), respectively. In surface wastewater near rivers, chlortetracycline and acetylsalicylic acid were detected frequently in the range of 0.017 - 5.404 and 0.029 - 0.269 ng/mL, respectively. Surface water near rivers had higher levels than surface water of domestic treatment plants.
Keywords
Pharmaceuticals and personal care products; LC/MS/MS; Surface water;
Citations & Related Records

Times Cited By Web Of Science : 2  (Related Records In Web of Science)
Times Cited By SCOPUS : 1
연도 인용수 순위
1 Kolpin, D.W. ; Furlong, E. T.; Meyer, M. T.; Thurman, E. M.; Zaugg, S. D.; Barber, L. B.; Buxton, H. T. Environ. Sci. Technol. 2002, 36, 1201.
2 Cahill, J. D.; Furlong, E. T.; Burkhardt, M. R.; Kolpin, D.; Anderson, L. G. J. Chromatogr. A 2004, 1041, 171.   DOI   ScienceOn
3 Miao, X. S.; Bishay, F.; Chen, M.; Metcalfe, C. D. Environ. Sci. Technol. 2004, 38, 3533.   DOI   ScienceOn
4 Renew, J. E.; Huang, C. H. J. Chromatogr. A 2004, 1042, 113.   DOI   ScienceOn
5 Daughton, C. G.; Ternes, T. A. Environ. Health Perspect. 1999, 107, 907.   DOI
6 Richardson, S. D. Anal. Chem. 2006, 78, 4021.   DOI   ScienceOn
7 Hernandez, F.; Sancho, J. V.; Ibanez, M.; Guerrero, C. Trends Anal. Chem. 2007, 26, 466.   DOI   ScienceOn
8 Ternes, T. A.; Hirsch, R.; Mueller, J.; Haberer, K.; Feresenius, J. Anal. Chem. 1998, 363, 329.
9 Cunningham, V. L.; Buzby, M.; Hutchinson, T.; Mastrocco, F.; Parke, N.; Roden, N. Env. Sci. Technol. 2006, 40, 3457.
10 Fent, K.; Weston, A. A.; Caminada, D. Aquatic. Toxicol. 2006, 76, 122.   DOI   ScienceOn
11 Crane, M.; Watts, C.; Boucard, T. Sci. Tot. Environ. 2006, 367, 23.   DOI   ScienceOn
12 Buchberger, W. W. Anal. Chim. Acta 2007, 593, 129.   DOI   ScienceOn
13 Gomez, M. J.; Petrovic, M.; Fernandez-Alba, A. R.; Barcelo, D. J. Chromatogr. A 2006, 1114, 224   DOI   ScienceOn
14 Abuin, S.; Codony, R.; Compano, R.; Granados, M.; Prat, M. D. J. Chromatogr. A 2006, 1114, 73.   DOI   ScienceOn
15 Karthikeyan, K. G.; Meyer, M. T. Sci. Total Environ. 2006, 361, 196.   DOI   ScienceOn
16 Development of Analytical Method and Study of Exposure of Pharmaceuticals and Personal Care Products in Enviroment; National Institute of Environmental Research, 2006.
17 Cherlet, M.; De Baere, S.; Croubels, S.; De Backer, P. Anal. Chim. Acta 2002, 473, 167.   DOI   ScienceOn
18 Cha, J. M.; Yang, S.; Carlson, K. H. J. Chromatogr. A 2006, 1115, 46.   DOI   ScienceOn