Seepage in to a Dike due to Tidal Fluctuation (조위변동(潮位變動)으로 인한 호안제내(護岸堤內)의 침투(浸透))

  • Kim, Sang Kyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.5 no.3
    • /
    • pp.71-84
    • /
    • 1985
  • Using a saturated-unsaturated transient flow equation the change of hydraulic heads within a dike due to tidal fluctuation is investigated in this study. The calculation is done by the use of a software computer program called FLUMP, which is based on a FEM technique and useful to the analyses of unsaturated flow problems. Some of the program has been supplemented in this study for the application to the rise of a tide. It is assumed that a dike is composed of two materials, that the tide rises and falls with a constant amplitude of 10 meters, and that water tables are located at 0m, 5m, and lam from the minimum tidal level. For these conditions the hydraulic heads are calculated for 8 cycles(96 hours) of tidal changes. It is known from the analysis that the hydraulic heads change with tidal level in some extent and that the amplitudes of the head varies depending on the location within the dike: the maximum amplitude shows near the toe of the dike, the amplitude decreases with increasing distance from the upstream face, and beyond a certain location the heads are unaffected by the tidal differences. Assuming that the dike has been completed in a moment the hydraulic heads are nearly stabilized in 96 hours towards some constant values corresponding to a specified water table.

  • PDF

Estimation of Groundwater Recharge by Considering Runoff Process and Groundwater Level Variation in Watershed (유역 유출과정과 지하수위 변동을 고려한 분포형 지하수 함양량 산정방안)

  • Chung, Il-Moon;Kim, Nam-Won;Lee, Jeong-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.5
    • /
    • pp.19-32
    • /
    • 2007
  • In Korea, there have been various methods of estimating groundwater recharge which generally can be subdivided into three types: baseflow separation method by means of groundwater recession curve, water budget analysis based on lumped conceptual model in watershed, and water table fluctuation method (WTF) by using the data from groundwater monitoring wells. However, groundwater recharge rate shows the spatial-temporal variability due to climatic condition, land use and hydrogeological heterogeneity, so these methods have various limits to deal with these characteristics. To overcome these limitations, we present a new method of estimating recharge based on water balance components from the SWAT-MODFLOW which is an integrated surface-ground water model. Groundwater levels in the interest area close to the stream have dynamics similar to stream flow, whereas levels further upslope respond to precipitation with a delay. As these behaviours are related to the physical process of recharge, it is needed to account for the time delay in aquifer recharge once the water exits the soil profile to represent these features. In SWAT, a single linear reservoir storage module with an exponential decay weighting function is used to compute the recharge from soil to aquifer on a given day. However, this module has some limitations expressing recharge variation when the delay time is too long and transient recharge trend does not match to the groundwater table time series, the multi-reservoir storage routing module which represents more realistic time delay through vadose zone is newly suggested in this study. In this module, the parameter related to the delay time should be optimized by checking the correlation between simulated recharge and observed groundwater levels. The final step of this procedure is to compare simulated groundwater table with observed one as well as to compare simulated watershed runoff with observed one. This method is applied to Mihocheon watershed in Korea for the purpose of testing the procedure of proper estimation of spatio-temporal groundwater recharge distribution. As the newly suggested method of estimating recharge has the advantages of effectiveness of watershed model as well as the accuracy of WTF method, the estimated daily recharge rate would be an advanced quantity reflecting the heterogeneity of hydrogeology, climatic condition, land use as well as physical behaviour of water in soil layers and aquifers.

Distribution and Change of Radon Concentration of Groundwater in the Area of Yeonpung-myeon, Goesan-gun, Korea (괴산군 연풍면 일대 지하수 중 라돈 함량 분포와 변동)

  • Byong-Wook Cho;Soo-Young Cho;Jong-Hyun Oh;Byeong-Dae Lee
    • The Journal of Engineering Geology
    • /
    • v.33 no.4
    • /
    • pp.587-598
    • /
    • 2023
  • To assess the distribution and temporal changes in radon concentration within a region in Yeonpung-myeon, Goesan-gun, known for elevated groundwater radon levels, we conducted a series of analyses, measuring radon concentration and DTW (Depth to water table) at 2-month intervals over 12 cycles. The investigation covered 10 groundwater wells and one stream within the designated area. The groundwater in the central part of the region exhibited high radon concentrations, ranging from 37.0 to 2,675.2 Bq/L. Conversely, the peripheral zones displayed comparatively lower radon concentrations, ranging from 10.6 to 37.9 Bq/L. This variation is attributed to the presence of granite porphyry that intruded into the Okcheon Formation, forming a fracture zone and contributing to elevated radon levels in the central part. In contrast, the peripheral locations, located within the Okcheon Formation and away from the granite porphyry intrusion, demonstrated lower radon concentrations. The observed significant fluctuation in radon concentration in the central area is associated with its low-lying topography. The pronounced seasonal changes in groundwater levels contribute to the migration of shallow, low-radon groundwater into areas with higher radon concentrations, explaining the observed variations in radon levels within the central part of the studied area.

The Estimation of Groundwater Recharge with Spatial-Temporal Variability at the Musimcheon Catchment (시공간적 변동성을 고려한 무심천 유역의 지하수 함양량 추정)

  • Kim Nam-Won;Chung Il-Moon;Won Yoo-Seung;Lee Jeong-Woo;Lee Byung-Ju
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.5
    • /
    • pp.9-19
    • /
    • 2006
  • The accurate estimation of groundwater recharge is important for the proper management of groundwater systems. The widely used techniques of groundwater recharge estimation include water table fluctuation method, baseflow separation method, and annual water balance method. However, these methods can not represent the temporal-spatial variability of recharge resulting from climatic condition, land use, soil storage and hydrogeological heterogeneity because the methods are all based on the lumped concept and local scale problems. Therefore, the objective of this paper is to present an effective method for estimating groundwater recharge with spatial-temporal variability using the SWAT model which can represent the heterogeneity of the watershed. The SWAT model can simulate daily surface runoff, evapotranspiration, soil storage, recharge, and groundwater flow within the watershed. The model was applied to the Musimcheon watershed located in the upstream of Mihocheon watershed. Hydrological components were determined during the period from 2001 to 2004, and the validity of the results was tested by comparing the estimated runoff with the observed runoff at the outlet of the catchment. The results of temporal and spatial variations of groundwater recharge were presented here. This study suggests that variations in recharge can be significantly affected by subbasin slope as well as land use.

A Study of Hydrogeological Properties Concerning to Groundwater Interference between Wells in the Yeongdo Island, Pusan, Korea (부산직할시 영도지역의 정호간 지하수 간섭에 관한 수리지질 특성 연구)

  • 김항묵
    • Journal of the Korean Professional Engineers Association
    • /
    • v.27 no.6
    • /
    • pp.72-84
    • /
    • 1994
  • This is about an environmental study of groundwater interference by hydrodynamic dispersion between the well A and well C in Dongsam-dong, the Yeongdo Island, Pusan, Korea. The groundwater in the study wells come from the fracture zones deeply seated in welded lapilli rhyodacitic tuff of the Late Cretaceous Yucheon Group. The boring depth at the well A is 190 meters, and the optimal pumping rate of the well A is about 100 cubic meters per day therein. The fractured aquifers in impermeable welded tuff show the conjugate fracturing type and are of anisotropic. The aquifers along two fracture zones in the well A are 80 and 100 meters in depth, respectively. It is not suggested that those fractured aquifers are simply connected between the well A and C. The sea level fluctuation by ebb and high tides in a day is not effective to the groundwater table in the well A. The pumping for 15 days at the well A doesn't give rise to any changes of the groundwater levels in the neighbor well C. The radius of influence of the well A is measured as less than 200 meters. The measuring electric conductivity for the test of salt tracer doesn't testify any relationship between the well A and the well C. There is the main difference between the well A and the well C on the basis of the water analysis of those wells. the well A is located in the high content zone of salt much over the standard value for drinking, whereas the other wells B. C. D are in the low content area of salt below the standard value. It is elucidated for the high content zone of salt in Yeongdo around the well A to have been uplifted over 20 meters.

  • PDF

An Analysis of the Relationships between Quantity and Drawdown at the Onyang Hot Spring Area (온양온천지구에서의 양수량-수위강하 관계 해석)

  • Jeong, Ji-Gon;Lee, Chol-Woo
    • The Journal of Engineering Geology
    • /
    • v.17 no.2 s.52
    • /
    • pp.177-185
    • /
    • 2007
  • Most of hot springs don't spring out naturally but are pumped by submersible pumps in Korea. When pumped piezometric head in a well is dropped with proportion to quantity. This research investigates relationships between quantity and drawdown at the Onyang hot spring area. There are 38 wells at this area and the depths of wells range from 124 m to 303 m. Piezometric heads of 4 wells were observed for about 10 months. Fluctuation patterns of piezometric heads seem to be a sine curve with a you period by a high demand and a slack season. Drawdowns of fluctuations were about 98-139 m depth to water table when wells were pumped at $2,300-4,800m^3/day$. A equation was made through analyzing quantity and drawdown.

A Review on Past Cases of Self-potential Surveys for Dikes and Embankments Considering Streaming Potential (흐름 전위 특성을 고려한 수리시설물에서의 자연 전위 탐사 사례 고찰)

  • Song, Seo Young;Cho, AHyun;Kang, Peter K.;Nam, Myung Jin
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.6
    • /
    • pp.1-17
    • /
    • 2021
  • Self-potential (SP) surveys measure naturally occurring differences in electrical potential in the absence of artificial sources and have been applied to various fields since the first application in mineral explorations. Among various causes of SP occurrences, streaming potential is generated by the flow of groundwater, and makes SP surveys suitable for the exploration of groundwater table fluctuation, fractures, sinkholes and landslide occurrences. Recently, there has been many studies that applied SP surveys to monitor water leakage through dikes and embankments. In this review paper, we first review the characteristics and theoretical backgrounds of streaming potential in saturated or unsaturated porous media to introduce it in the embankment among various application field. After the review of the background theory, we review the past cases of field SP surveys on dikes and embankments and also the characteristics of field streaming potential data in the surveys. Further, by analyzing past studies of qualitative as well as quantitative interpretation of SP survey data, we show the possibility of quantitative interpretation of streaming potential data obtained on dikes and embankments. Consequently, it is hope that this review paper helps researches on SP surveys on dikes and embankments, and provides basis for interpretation methods of the SP data to identify leaked area and further leakage rate (or permeability).

Analysis of Geological Factors for Risk Assessment in Deep Rock Excavation in South Korea (한국의 대심도 암반 굴착 위험도 산정을 위한 인자 분석)

  • Ihm, Myeong Hyeok;Lee, Hana
    • Tunnel and Underground Space
    • /
    • v.31 no.4
    • /
    • pp.211-220
    • /
    • 2021
  • Tunnel collapse often occurs during deep underground tunneling (> 40 m depth) in South Korea. Natural cavities as well as water supply pipes, sewer pipes, electric power cables, artificial cavities created by subway construction are complexly distributed in the artificial ground in the shallow depths of the urban area. For deep tunnel excavation, it is necessary to understand the properties of the ground which is characterized by porous elements and various geological structures, and their influence on the stability of the ground. This study analyzed geological factors for risk assessment in deep excavation in South Korea based on domestic and overseas case study. As a result, a total of 7 categories and 38 factors were derived. Factors with high weights were fault and fault clay, differential stress, rock type, groundwater and mud inrush, uniaxial compressive strength, cross-sectional area of tunnel, overburden thickness, karst and valley terrain, fold, limestone alternation, fluctuation of groundwater table, tunnel depth, dyke, RQD, joint characteristics, anisotropy, rockburst and so forth.

Collection of Adult and Larval Mosquitoes in U.S. Army Compounds in the Republic of Korea During 1979~1983 (한국에 주둔한 미군지역내에서의 모기 성충과 유충 채집(1979~1983))

  • ;R.K
    • Parasites, Hosts and Diseases
    • /
    • v.22 no.1
    • /
    • pp.102-108
    • /
    • 1984
  • This paper is the result of adult female mosquito and larval collection in U.S. Army Installations in Korea from 1979 to 1983. New Jersey light traps were operated for adult collection from May to October. The primary concern of this surveillance is to determine when to recommend insecticide spraying for mosquito control in the Army areas. The 5th Preventive Medicine Unit have developed an "index" level of female mosquitoes in a light trap similar to other U.S. Army Agencies in other parts of the world. When 10 female mosquitoes are reached on two consecutive trap-night, or 5 known vector females are collected, fogging is recommended in the trap areas. 1. Mosquito collections were conducted in 12 U.S. Army areas by operating 39 New Jersey light traps. Mosquitoes collected from the areas were identified to be 17 species comprising 3 genera. Anopheles sinensis (40%), Culex tritaeniorhynchus (31%), Aedes vexans nipponii (19 %) and Culex pipiens pallens (10%) appeared to be the most common species in the areas. 2. The species, population density and monthly appearance of adult mosquitoes were found to be almost the same in the all provinces involved. And Japanese Encephalitis vector mosquitoes, Culex tritaeniorhynchus, showed their seasonal fluctuation from July to September with a peak in August each year. 3. Larval habitats confirmed in the Army areas were categorized into 16 types as shown in Table 3. The mosquito larvae collected in those habitats were identified to be 15 species representing 4 genera. Most breeding sites in the Army areas were those which are activated during the wet season. 4. More mosquitoes were collected from the Kyungki Province than from the other Provinces. The reason for more collection of mosquitoes from military installations in the Kyungki Province appears to be the geographic characteristics surrounded by rice fields, marshes and other stagnant water areas.

  • PDF