• Title/Summary/Keyword: water surface discharge

Search Result 635, Processing Time 0.027 seconds

Hourly SWAT Watershed Modeling for Analyzing Reduction Effect of Nonpoint Source Pollution Discharge Loads (비점원오염 저감효과 분석을 위한 시단위 SWAT 유역 모델링)

  • Jang, Sun Sook;Ahn, So Ra;Choi, Joong Dae;Kim, Seong Joon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.1
    • /
    • pp.89-97
    • /
    • 2015
  • This study is to assess the effect of non-point source pollution discharge loads between tillage and no-tillage applications for upland crop areas using SWAT (Soil and Water Assessment Tool) watershed modeling. For Byulmi-cheon small rural catchment ($1.17km^2$) located in upstream of Gyeongan-cheon watershed, the rainfall, discharge and stream water quality have been monitored in the catchment outlet since 2011. The SWAT model was calibrated and validated in hourly basis using 19 rainfall events during 2011-2013. The average Nash-Sutcliffe model efficiency and $R^2$ (determination coefficient) for streamflow were 0.67 and 0.79 respectively. Using the 10 % surface runoff reduction from experiment results for no-tillage condition in field plots of 3 % and 8 % slopes under sesami cultivation, the soil saturated hydraulic conductivity for upland crop areas was adjusted from 0.001 mm/hr to 0.0025 mm/hr in average. Under the condition, the catchment sediment, T-N (total nitrogen, TN), and T-P (total phosphorus, TP) discharge loads were reduced by 6.9 %, 7.4 %, and 7.7 % respectively.

Analysis of Pollutant Loads and Physical Oceanographic Status at the Developing Region of Deep Sea Water in East Sea, Korea (동해 심층수 개발해역의 오염부하량 해석과 해황변동)

  • Lee, In-Cheol;Kim, Kyung-Hoi;Yoon, Han-Sam
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.340-345
    • /
    • 2003
  • This study, as a basic study for establishing a influence forecasting/estimating model when drain the deep sea water to the ocean after using it, carried out studies as follows; 1) estimating the amount of river discharge and pollutant loads inflowing into the developing region of deep sea water in East Sea, Korea 2) a field observation of tidal current, vertical distribution of water temperature and salinity, and 3-D numerical experiment of tidal current to analysis physical oceanographic status. The amount of river discharge flowing into the study area was estimated about $462.6{times}10^{3}m^{3}/day$ of daily mean in 2002 year. annual mean pollutant load of COD, TN and TP were estimated 7.02 ton-COD/day, 4.06 ton-TN/day and 0.39 ton/day, respectively. Field observation of tidal current results usually show about $20{\sim}40cm/sec$ of current velocity at the surface layer, it indicated a tendency that the current velocity decreases under 20cm/sec as the water depth increases. We could find a stratification within approximately the depth of 30m in field observation area, and the depth increases. We could find a stratification within approximately the depth of 30m in field observation area, and the differences of water temperature and salinity between the surface layer and bottom layer were about $18^{\circ}C$ and 0.8 psu, respectively. On the other hand, we found that there was a definite as the water mass of deep sea water about 34 psu of salinity.

  • PDF

Analysis of Pollutant Loads and Physical Oceanographic Status at the Developing Region of Deep Sea Water in the East Sea (동해 심층수 개발해역의 오염부하량 해석과 해동변동)

  • LEE IN-CHEOL;YOON BAN-SAM
    • Journal of Ocean Engineering and Technology
    • /
    • v.19 no.1 s.62
    • /
    • pp.14-19
    • /
    • 2005
  • As a basic study for establishing the input conditions of a forecasting/estimating model, used for deep-sea water drainage to the ocean, this study was carried out as follows: 1) estimating the amount of river discharge and pollutant loads into the developing region of deep sea water in the East Sea, Korea, 2) a field observation of tidal current, vertical water temperature, and salinity distribution, 3) 3-D numerical experiment of tidal current to analyze the physical oceanographic status. The amount of river discharge flowing into this study area was estimated at about $462.7{\times}103 m\^3/day$ of daily mean in 2002. Annual mean pollutant load of COD, TN, and TP were estimated at 7.02 ton-COD/day, 4.06 ton-TN/day, and 0.39 ton/day, respectively. Field observation of tidal current normally shows 20-40cm/sec of current velocity at the surface layer, and it decreases under 20cm/sec as the water depth increases. We also found a stratification condition at around 30m water depth in the observation area. The differences in water temperature and salinity, between the surface layer and the bottom layer, were about 18 C and 0.8 psu, respectively. On the other hand, we found a definite trend of 34 psu salinity water mass in the deep sea region.

Measurement of Discharge Using the Entropy Concept (엔트로피 개념에 의한 유량측정 기법)

  • Choo, Tai-Ho;Lee, Seung-Kwan
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2006.05a
    • /
    • pp.342-346
    • /
    • 2006
  • The method presented is also efficient and applicable in estimating the discharge in high flows that are very difficult or impossible to measure before, due to technical or theoretical reasons. The method can drastically reduce the time and cost of measurement, regardless of the irregularity in the geometrical shape. With Microwave Water Surface Velocity Meter, An entropy based method for determining the discharge in the rivers can be used to develop real-time discharge measurement system (RDMS) which can carry out the real-time inflow hydrograph.

  • PDF

SATELLITE-MEASURED TEMPORAL AND SPATIAL VARIABILITY OF TOKACHI RIVER PLUME

  • Lihan, Tukimat;Saitoh, Sei-Ichi;Iida, Takahiro;Matsuoka, Atsushi;Hirawake, Toru;Iida, Kohji
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.118-121
    • /
    • 2006
  • Variations in the extent and dispersal of river plume are important in the study of coastal environment. The objectives of this study are to examine relationship between satellite detected plume area and river discharge and to clarify the temporal and spatial dynamic of plume from Tokachi River, Hokaido, Japan. We used 1.1 km spatial resolution of SeaWiFS normalized water-leaving radiance (nLw) images from 1998 to 2002. Supervised maximum likelihood classification was implemented to define classes of surface water optical properties. Satellite observed plume area was correlated to the amount of river discharge from April to October. First mode (44% of variance) of EOF analysis shows the turbid plume distribution resulting from re-suspension by strong wind mixing along the coast during winter. This mode also shows plume distribution along-shelf direction in spring and late summer. Second mode (17% of variance) shows spring pattern across-shelf direction due to strong discharge of snow melting water.

  • PDF

Exploration and Verification of Submarine Groundwater Discharge on Jeju Island by Remotely Sensed Based Water Quality Analysis (시계열 수질 분석에 의한 제주도의 해저용출수 탐사 및 검증)

  • Baek Seung-Gyun;Park Maeng-Eon
    • Economic and Environmental Geology
    • /
    • v.38 no.4 s.173
    • /
    • pp.395-409
    • /
    • 2005
  • To explore submarine groundwater discharge (SGD) into the coastal zone of Jeju Island, the water quality analysis with seasonal remotely sensed data was carried out. If the groundwater is directly discharged into the ocean, the water quality of coastal zone is influenced. Therefore sea surface temperature (SST), the transparency, and Chlorophyll-a's concentration were analyzed for extracting the anomaly zone related with SGD using Landsat Thematic Mapper (TM) data acquired on April, August, and December. Then the spatial characteristics of springs, which located along the coastal area, were analyzed by CIS data integration based on Fuzzy logic. The integration results were compared with the anomaly zone extracted from Landsat TM data, and it is considered that springs has close relationship with SGD.

A Study of Hydraulic Turbine Design for The Discharge Water Energy Harvesting (방출 수 에너지 하베스팅을 위한 수차 설계에 관한 연구)

  • Cheong, Han Seok;Kim, Chung Hyeok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.1
    • /
    • pp.78-83
    • /
    • 2021
  • We modeled the helical turbine and three modified helical turbines for the structure of the hydraulic turbine for discharge water energy harvesting. A structure that can reduce the load applied to the blade by placing a center plate is our basic concept. The shape was reduced to 1/5, fixed to a size of 240 mm in height and 247 mm in diameter, and modeled by changing the width and the angle of the hydraulic turbine blade. The pipe inner diameter of the simulation pipeline equipment is 309.5 mm, and the simulation section was 4 m in the entire section. The flow velocity was measured for two cases, 1.82 m/s and 2.51 m/s, with the parameters being the amount of power generation, hydraulic turbine's torque, and hydraulic turbine's rotation speed. The measurement results confirmed that the flow velocity at the center, which has no pipe surface resistance, has a great influence on the amount of power generation; therefore, the friction area of the turbine blade should be increased in the center area. In addition, if the center plate is placed on the helical turbine, durability can be improved as it reduces the stress on the blade.

Deposition of Super Hydrophobic a-C:F Films by Dielectric Barrier Discharge at Atmospheric Pressure

  • Kim, Duk-Jae;Kim, Yoon-Kee;Han, Jeon-Geon
    • Journal of the Korean institute of surface engineering
    • /
    • v.44 no.2
    • /
    • pp.50-54
    • /
    • 2011
  • Hydrophobic a-C:F film was coated on polycarbonate film with $CF_4$, $C_2F_6$ and HFC ($C_2F_4H_2$) gas in helium discharge generated by 5~100 kHz AC power supply at atmospheric pressure and room temperature. The highest water contact angle of the a-C:F film formed with $He/C_2F_6$ mixed gas is $155^{\circ}$. X-ray photoelectron spectrum showed that there was 40% of C-$CF_3$ bond at the surface of the super hydrophobic film. The contact angle and deposition rate were decreased with increasing substrate temperature. The contact angle was generally increased with the surface roughness of the film. The contact angle was high when the surface microstructure of the film was fine and sharp at the similar roughness and chemical composition of the surface.

Analysis of Hydrological Factor for Permeable Pavement by using Soil Tank Experiment (토조실험에 의한 투수성 포장재의 수문학적 요소 분석)

  • Jun, Sang-Mi;Lee, Jung-Min;Park, Jae-Hyeoun;Lee, Sang-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.2
    • /
    • pp.181-192
    • /
    • 2009
  • In this study, the hydrological properties of permeable pavement were analyzed by the experiment and the numerical simulation. The numerical model used was a modified SWMM especially for considering the hydrological response of permeable pavement. The parameters of modified SWMM were revised by the experimental results, and then the practicability was evaluated through the comparison of the experimental and numerical simulation results. In the experiments, three different rainfall intensities such as 65 mm/hr, 90 mm/hr, 95 mm/hr were supplied for 4 hrs, and the hydraulic properties including surface outflow, subsurface outflow, ground water level, soil water contents were measured for 10 hrs. The results showed rainfall intensity effected directly on surface outflow volume and subsurface outflow volume was more effected by ground water level than rainfall intensity. The ground water level and the soil water contents were under estimated as compared with the experimental data except the portion of occurring direct runoff. The surface and subsurface outflow discharge were simulated very well in comparison with the experimental data. Consequently, the modified SWMM could be used very effectively to evaluate the hydrological property of permeable pavement.

A Study on the Accumulation Phenomena of Oxidized Starch in White Water of closed Fine Papermaking Process (Part 2) -Effect of broke use ratio and surface sizing pick up- (백상지 공정 폐쇄화에 따른 백수 내 산화전분의 축적 현상에 관한 연구 (제2보) -파지혼합비율 및 표면사이징 픽업량 변화의 영향-)

  • Ahn, Hyun-Kyun;Lee, Hak-Lae
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.36 no.3
    • /
    • pp.35-43
    • /
    • 2004
  • Reduction of fresh water consumption and effluent discharge provide diverse advantages in raw materials and energy savings. Papermaking system closure, however, reduces the efficiency of additives, decreases retention and dewatering, and causes many other Problems in papermaking. Accumulation of inorganic and organic substances in the process white water is the prime cause of these problems. Understanding of the accumulation phenomena of the detrimental substances in the papermaking process is of great importance for papermaking system closure. In this study a process simulation method was employed to analyze the accumulation phenomena of anionic starch in the process white water as the reuse rate of dry broke and pick up of surface sizing agent is increased. Steady state simulation studies were carried out based on the model developed in previous study. The variation of dissolved starch concentration in each process unit was monitored as a function of reuse rate of dry broke and surface sizing agent pick up rate. The result showed that dissolved starch concentration Increased as reuse rate of dry broke and surface sizing agent pick up rate was increased.