• 제목/요약/키워드: water removal

검색결과 4,225건 처리시간 0.033초

구형 지르코니아를 갖는 수방전관의 수질성분변환 및 세균제거특성 (Removal characteristic of Escherichiacoli and water property conversion for Discharge tube with globular $ZrO_2$)

  • 이동훈;박홍재;박재윤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.550-553
    • /
    • 2003
  • This paper was shown water properly conversion and removal characteristic of escherichia coli for discharge tube with $ZrO_2$ beads. At the result of the removal characteristic experiments of escherichia coli using the discharge tube with $ZrO_2$ beads, because the electric field is also increased when input voltage is increased, the removal characteristic of escherichia coli was appeared relation connection to input voltage. And if a passing number of test water in discharge tube with $ZrO_2$ beads is increased, the removal ratio of escherichia coli is to be increased because passing number of electric field section is increased. And if diameter of $ZrO_2$ beads is increased, the removal time of escherichia coli is to be decreased because dielectric polalization of $ZrO_2$ beads. Also, the removal ratio of escherichia coli of the discharge tube with $ZrO_2$ beads. is appeared higher than the removal ratio of the discharge tube without $ZrO_2$ beads. And a salutation point of ozone and $H_2O_2$ generation density inner water was appeared near 60[min].

  • PDF

산화망간피복여재를 이용한 용존망간 제거 (Soluble Manganese Removal Using Manganese Oxide Coated Media (MOCM))

  • 김진근;정세채;고수현
    • 상하수도학회지
    • /
    • 제20권6호
    • /
    • pp.813-822
    • /
    • 2006
  • Soluble manganese removal was analyzed as a function of filter media, filter depth, presence or absence of chlorination, and surface manganese oxide concentration in water treatment processes. Sand, manganese oxide coated sand (MOCS), sand+MOCS, and granular activated carbon(GAC) were used as filter media. Manganese removal, surface manganese oxide concentration, turbidity removal, and regeneration of MOCS in various filter media were investigated. Results indicated that soluble manganese removal in MOCS was rapid and efficient, and most of the removal happened at the top of the filter. When filter influent (residual chlorine 1.0mg/L) with an average manganese concentration of 0.204mg/L was fed through a filter column, the sand+MOCS and MOCS columns can remove 98.9% and 99.2% of manganese respectively on an annual basis. On the other hand, manganese removal in sand and the GAC column was minimal during the initial stage of filtration, but after 8 months of filter run they removed 99% and 35% of manganese, respectively. Sand turned into MOCS after a certain period of filtration, while GAC did not. In MOCS, the manganese adsorption rate on the filter media was inversely proportional to the filter depth, while the density of media was proportional to the filter depth.

국내 복류수 및 강변여과수 취수시설의 오염물질 제거특성에 관한 연구 (A study on pollutants removal characteristics of domestic riverbed filtration and riverbank filtration intake facilities)

  • 정찬우;이선익;신성우;송창현;조부근;최재원
    • 상하수도학회지
    • /
    • 제37권5호
    • /
    • pp.281-288
    • /
    • 2023
  • This study was performed to evaluate the pollutants removal characteristics of two types of RBFs(Riverbank filtration, Riverbed filtration) intake facilities installed in Nakdong River and in Hwang River respectively. The capacity of each RBF is 45,000 m3/d for riverbank filtration intake facility and 3,500 m3/d for riverbed filtration intake facility. According to data collected in the riverbank filtration site, removal rate of each pollutant was about BOD(Biochemical Oxygen Demand) 52%, TOC(Total Organic Carbon) 57%, SS(Suspended Solids) 44%, Total coliforms 99% correspondingly. Furthermore, Microcystins(-LR,-YR,-RR) were not found in riverbank filtered water compared to surface water in Nakdong River. DOC(Dissolved Organic Carbon) and Humics which are precursors of disinfection byproduct were also reported to be removed about 59% for DOC, 65% for Humics. Based on data analysis in riverbed filtration site in Hwang River, removal rate of each contaminant reaches to BOD 33.3%, TOC 38.5%, SS 38.9%, DOC 22.2%, UV254 21.2%, Total coliforms 73.8% respectively. Additionally, microplastics were also inspected that there was no obvious removal rate in riverbed filtered water compared to surface water in Hwang River.

ENHANCED COAGULATION: DETERMINATION OF CONTROLLING CRITERIA AND AN EFFECT ON TURBIDITY REMOVAL

  • Kim, Seung-Hyun
    • Environmental Engineering Research
    • /
    • 제10권3호
    • /
    • pp.105-111
    • /
    • 2005
  • The applicability of the USEPA's (United States Environmental Protection Agency) three criteria of enhanced coagulation (criterion 1-TOC level less than 2 mg/l. before chlorination; criterion II-% requirement of TOC removal; criterion III-point of diminishing return) for Korean waters was evaluated in this study. This study also investigated an effect of enhanced coagulation on turbidity removal, and attempted to identify the best coagulant for enhanced coagulation. Three different waters were used in this study: one river water and two lake waters. five different coagulants were used: alum, liquid alum, PACl, ferric chloride with and without water. Results of this study showed that all three criteria were achievable for the tested waters. For these waters, controlling criterion was found to be different depending upon raw water characteristics. When initial Toe level was low(< 4 mg/L), criterion I (< 2 mg/L) could be the controlling criterion. As TOC level increased, criterion II (% TOC removal) became the controlling criteria. It was possible to achieve different goals of turbidity and TOC removals. Although the optimum region of TOC removal was more acidic than that of turbidity removal, there was no conflict between these two removals. The best coagulant was found to be different depending upon the evaluation tool: maximum and optimum removal. ferric chloride was more effective than alum in terms of the maximum TOC removal, while Al-based coagulant such as alum or PACl was the best coagulant in terms of the optimum TOC removal.

인공습지의 수질개선 효과 분석모델 개발 (Development of Pollutant Removal Model in the Artificial Wetland)

  • 최지용
    • 한국습지학회지
    • /
    • 제4권1호
    • /
    • pp.51-61
    • /
    • 2002
  • The wetland is a biologically integrated system consisting of water, soil, bacteria, plants, and animals. The wetland helps sustain the ecosystem, control the micro-climate and flood, maintain the ground water level, and provide fishing grounds. From the environmental standpoint, the wetland plays a vital role in reducing water pollution by filtering out sand and other polluted matters, producing oxygen, absorbing chemicals and nutrients. For these reasons, interest in restoring the wetlands has been steadily increasing. Artificial wetland, which is also referred to as created wetland or constructed wetland, is an alternative to natural wetland. Like natural wetland, artificial wetland is environmentally friendly and can effectively lower pollutant levels. The Korea government is actively reviewing the construction of artificial wetlands in mining and water supply areas to decrease nonpoint pollutant sources. This paper attempts to develop a pollutant removal model for the water quality improvement function of artificial wetlands. Artificial wetland can improve the quality of the water; however, depending on the type of water inflow, vegetation and hydrology, its effect can be different.

  • PDF

Electrochemical Removal Efficiency of Pollutants on ACF Electrodes

  • Oh, Won-Chun;Park, Joung-Sung;Lee, Ho-Jin;Yum, Min-Hyung
    • Carbon letters
    • /
    • 제5권4호
    • /
    • pp.191-196
    • /
    • 2004
  • The electrochemical removal (ECR) of water pollutants by activated carbon fiber (ACF) electrodes from wastewater was investigated over wide range of electrochemical reaction time. The ECR capacities of ACF electrodes were associated with their internal porosity and were related to physical properties and to reaction time. And, surface morphologies and elemental analysis for the ACFs after electrochemical reaction are investigated by SEM and EDX to explain the changes in adsorption properties. The FT-IR spectra of ACFs for the investigation of functional groups show that the electrochemical treatment is consequently associated with the homogeneous removal of pollutants with the increasing surface reactivity of the activated carbon fiber surfaces. The ACFs were electrochemically reacted to waste water to investigate the removal efficiency for the COD, T-N and T-P. From these removal results of pollutants using ACFs substrate, satisfactory removal performance was obtained. The outstanding removal effects of the ACFs substrate were determined by the properties of the material for adsorption and trapping of organics, and catalytic effects.

  • PDF

정수처리에서 미량유해물질 제거를 위한 Peroxone 공정의 적용성 및 경제성 평가 (Evaluation of Applicability and Economical Efficiency of Peroxone Process for Removal of Micropollutants in Drinking Water Treatment)

  • 손희종;김상구;염훈식;최진택
    • 한국환경과학회지
    • /
    • 제22권7호
    • /
    • pp.905-913
    • /
    • 2013
  • We compared the applicability and economical efficiency of peroxone process with those of ozone process in the existing water treatment plant on downstream of Nakdong River. After comparing the peroxone process for removing geosmin with the ozone process in lab scale test, peroxone process showed much higher removal efficiency than the ozone process at the same ozone dosage. Proper range of $H_2O_2/O_3$ ratio were 0.5~1.0 and the half-life of geosmin was about 5.5~6.8 min when the $H_2O_2/O_3$ ratio was set to 0.5 during 1~2 mg/L of ozone dosage. Peroxone process could reduce the ozone dosage about 50 to maximum 30% for the same geosmin removal efficiency compared to the ozone process in the pilot scale test. In case of 1,4-dioxane treatment, peroxone process could have 3~4 times higher efficiency than ozone process at the same ozone dosage. The results of estimating the economical efficiency of ozone and peroxone process for treating geosmin and 1,4-dioxane by using pilot scale test, in case of the removal target was set to 85% for these two materials, the cost of peroxane process could be reduced about 1.5 times compared to ozone process, and in the same production cost peroxone process could have 2~3 times higher removal efficiency than ozone process. The removal efficiency by peroxone process showed a large difference depending on the physicochemical characteristics of target materials and raw water, therefore detailed examination should be carried out before appling peroxone process.

Pilot 규모 연속배열형 인공습지의 영양염류 제거효능 규명 및 평가모델 연구 (A Pilot-Scale Study of Multiple Stage of Constructed Wetland Treatment System and Modeling for Nutrient Removal)

  • 최승일;;이재성
    • 한국물환경학회지
    • /
    • 제26권5호
    • /
    • pp.781-788
    • /
    • 2010
  • A pilot study was performed to examine the feasibility of multiple stage of constructed wetland (CW) for nutrient removal. The system is composed of six wetland cells connected with water-ways. The hydraulic of wetland cells is designed as free water surface flow. The treatment capacity was $25m^3d^{-1}$ at HRT of about one day for each cell. The magnitude of nutrient removal was related with the length of wetlands and plant density. Total N and P removal rates were 1353 and $246mg\;m^{-2}d^{-1}$ respectively. The pilot-scale reactor was model as continuous flow system containing contribution of CSTR and PFR typed-reactors. The $k-C^*$ model equation was applied to predict N and P reduction. The result indicated the equation was well guided to estimate reduction of $NO_3-N$ and $PO_4-P$.

물을 흡수매체로 이용한 트리메틸아민과 환원황화합물의 제거효율 비교 연구 (Removal Efficiency of Some Odorants against Water as Sorptive Media: A Case Study on Trimethylamine and Reduced Sulfur Compounds)

  • 안지원;김기현;옥준석;김용현
    • 한국대기환경학회지
    • /
    • 제25권6호
    • /
    • pp.512-522
    • /
    • 2009
  • In this study, the removal efficiency of trimethylamine (TMA) and four reduced sulfur compounds (RSC) of $H_2S$, $CH_3SH$, DMS, and DMDS was investigated using deionized water as absorbent. To this end, two types of experiments were conducted which include: (1) by passing both RSC and TMA standard gases through water contained in an impinger system and (2) by passing TMA gases through a water spray system. In the former method, TMA standard gases were effectively removed (below detection limit) in all experiments. Likewise, minor fractions of some RSC ($CH_3SH$, DMS, and DMDS) were removed by water in line with theoretical expectations. In addition, the first type of our experiment was extended further to test some commercially available odor treatment products. The results of this test showed that removal efficiencies of RSC $(8.2\pm13.7\sim43.7\pm2.48%)$ were different significantly among 4 kinds of absorbent, while the removal of TMA was consistently good as water. In the second phase of experiment, removal efficiency of TMA was tested by passing its standard gas through a water spray system. The overall results of our study showed that the actual removal efficiency of odorants by water (as sorptive media) approached the values that can be predicted theoretically (by Henry's law).

수중의 인 제어기술 개발 (Development of Control Technology of Phosphorus in Water)

  • 김경태;강선홍
    • 상하수도학회지
    • /
    • 제13권3호
    • /
    • pp.56-60
    • /
    • 1999
  • In this study the feasibility of usage of raw sludge (sludge from water treatment plant) and chalk from schools and institutes was investigated to remove the phosphorus in water and wastewater. In this study phosphorus removal efficiencies of sludge and chalk were investigated by changing various factors. The time to reach the equilibrium using chalk and raw sludge under different pHs was obtained. Based on this result, Freudlich adsorption isotherm was applied. Results showed that a portion of phosphorus was removed by adsorption to chalk and raw sludge. The phosphorus removal efficiency using calcinated chalk was about three times higher than that of chalk. It means that some portion of $CaCO_3$ contained in chalk was converted to CaO by calcination and this was proved by X-ray diffraction experiment. About 90% phosphorus removal was observed using sludge and calcinated chalk respectively while about 20% phosphorus removal efficiency was achieved using chalk from the water sample in Lake Sihwa.

  • PDF